Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Fast electron transport dynamics and energy deposition in magnetized, imploded cylindrical plasma

Inertial confinement fusion approaches involve the creation of high-energy-density states through compression. High gain scenarios may be enabled by the beneficial heating from fast electrons produced with an intense laser and by energy containment with a high-strength magnetic field. Here, we report experimental measurements from a configuration integrating a magnetized, imploded cylindrical plasma and intense laser-driven electrons as well as multi-stage simulations that show fast electrons transport pathways at different times during the implosion and quantify their energy deposition contribution. The experiment consisted of a CH foam cylinder, inside an external coaxial magnetic field of 5 T, that was imploded using 36 OMEGA laser beams. Two-dimensional (2D) hydrodynamic modelling predicts the CH density reaches 9.0 g cm − 3 , the temperature reaches 920 eV and the external B-field is amplified at maximum compression to 580 T. At pre-determined times during the compression, the intense OMEGA EP laser irradiated one end of the cylinder to accelerate relativistic electrons into the dense imploded plasma providing additional heating. The relativistic electron beam generation was simulated using a 2D particle-in-cell (PIC) code. Finally, three-dimensional hybrid-PIC simulations calculated the electron propagation and energy deposition inside the target and revealed the roles the compressed and self-generated B-fields play in transport. During a time window before the maximum compression time, the self-generated B-field on the compression front confines the injected electrons inside the target, increasing the temperature through Joule heating. For a stronger B-field seed of 20 T, the electrons are predicted to be guided into the compressed target and provide additional collisional heating. This article is part of a discussion meeting issue ‘Prospects for high gain inertial fusion energy (part 2)’.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical simulation of the plasma generated by the interaction high-current electron beam with Al target

The results of one dimensional particle-in-cell simulations of the dynamics of plasma generated during the interaction of a high-energy ({<=}200 keV) and high-current ({<=}15 A/cm{sup 2}) electron beam with an aluminum target are presented. The generated target plasma is low-ionized and characterized by non-Maxwellian electron energy distribution. The density and electron temperature of the plasma, which expands toward the anode at a typical velocity of {approx}10{sup 5} cm/s, does not exceed 4 Multiplication-Sign 10{sup 14} cm{sup -3} and 1 eV, respectively, which is in satisfactory agreement with the experimental results presented in W. An et al., J. Appl. Phys. 110, 093304 (2011). The results of the simulations showed also acceleration of the ions from the target plasma toward the anode by the potential of the non-compensated space charge of the electron beam. The typical velocity of these energetic ions is {approx}10{sup 8} cm/s and depends on the electron current density and energy. These ions partially compensate the space charge of the electron beam, which leads to a decrease in the depth of the potential well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

When and how to treat an IMRT patient on a second accelerator without replanning?

When a linear accelerator is unavailable for treatment, a clinical decision is imminent regarding whether a patient should be treated on a linear accelerator other than the machine the patient was scheduled on, or whether treatment should be postponed until the original Linac becomes available. This work investigates the feasibility of switching patients to different accelerators for intensity-modulated radiation therapy (IMRT). We have performed Monte Carlo simulations of photon beams from different Linac models and vendors. Prostate and head and neck (H&N) treatment plans for Siemens Primus, Primart, and Varian 21EX accelerators are studied in this work. Dose distributions for given plans are recalculated using different beam data with the same nominal energy from different Linacs. We have compared dose-volume histograms (DVHs) and the maximum, the minimum, and the mean doses to the target and critical structures because of switching accelerators. In the process of switching a treatment plan to a different accelerator, issues exist, including optimum penumbra compensation, dose distribution at the boundary of target and critical structures, and multileaf collimator (MLC) leaf-width effects, which need to be considered and verified with measurements. Our Monte Carlo simulation results confirm that, for the cases we tested, the dose received by 95% of the planning target volume differs by 0.2% to 1.5% between Siemens Primus and Varian 21EX Linacs. The discrepancy is within our clinical acceptance criteria of 3% for IMRT treatments. In making the final decision on whether to switch machines or not, the tumor control probabilities (TCPs) based on a linear-quadratic model are compared. Based on the analyses performed in this work, it is therapeutically more beneficial to switch a patient to a different machine than to postpone a treatment until the original machine is available, especially for fast-growing tumors such as H&N cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic aperture calculation for 100 GeV Au-Au and 250 GeV pp lattices with near third order resonance working point

In the preparation for the 2011 RHIC 250 GeV polarized proton (pp) run, both experiment and simulation were carried out to investigate the possibility to accelerate the proton beam with a vertical tune near 2/3. It had been found experimentally in Run-9 that accelerating the proton beam with a vertical tune close to 2/3 will greatly benefit the transmission of the proton polarization. In this note, we report the calculated dynamic apertures with the 100 GeV Au run and 250 GeV proton run lattices with vertical tunes close to the third order resonance. We will compare the third order resonance band width between the beam experiment and the simulation with the 100 GeV Au lattices. And we also will compare the calculated resonance band width between the 100 GeV Au and 250 GeV proton run lattices.

43 PARTICLE ACCELERATORS↗

Application of Geant4 Monte Carlo simulation in dose calculations for small radiosurgical fields

The Geant4 toolkit was used to develop a Monte Carlo (MC)-based engine for accurate dose calculations in small radiation field sizes. The Geant4 toolkit (version 10.1.p02) was used to simulate 6-MV photon beam of a Varian2100C linear accelerator that is being used for stereotactic radiosurgery (SRS) treatment with small radiation fields. Geometric models of 3 in-house designed radiosurgical divergent cones, with the diameters of their projections at the isocenter being 10, 20, and 30 mm, were simulated. The accuracy of the MC simulation technique was examined by reproducing several different simulated dosimetric parameters of the primary beams with the experimental data. The dose distributions are first checked for single beams for each cone, then standard multiple field (SMF) techniques are applied. A sample set of DICOM files from computed tomography (CT) scan imaging of a patient's head was converted to the Geant4 geometry format to implement MC-based engine for a clinical test. To validate the accuracy of the MC-based calculations for SMF arrangements, the isodose lines from MC simulation in water phantom were compared with the measured isodose lines using EBT3 Gafchromic film in Solid Water phantoms. Agreements between measured and simulated depth dose values and beam profiles for SRS cones were generally within 2%/2 mm. For output factors, the largest discrepancy was observed for 10 mm SRS cone, which was 1.7%. For SMF techniques, in SRS cones, the MC simulation and EBT3 Gafchromic film dosimetry were in acceptable agreement (5%/5 mm). Excellent agreement between the results of the MC-based and measured dose values for both single and SMF techniques in SRS cones indicates the ability of the Geant4 toolkit to be applied as the platform for treatment planning of advanced radiotherapy techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comprehensive MRI simulation methodology using a dedicated MRI scanner in radiation oncology for external beam radiation treatment planning

Purpose: The use of magnetic resonance imaging (MRI) in radiation oncology is expanding rapidly, and more clinics are integrating MRI into their radiation therapy workflows. However, radiation therapy presents a new set of challenges and places additional constraints on MRI compared to diagnostic radiology that, if not properly addressed, can undermine the advantages MRI offers for radiation treatment planning (RTP). The authors introduce here strategies to manage several challenges of using MRI for virtual simulation in external beam RTP. Methods: A total of 810 clinical MRI simulation exams were performed using a dedicated MRI scanner for external beam RTP of brain, breast, cervix, head and neck, liver, pancreas, prostate, and sarcoma cancers. Patients were imaged in treatment position using MRI-optimal immobilization devices. Radiofrequency (RF) coil configurations and scan protocols were optimized based on RTP constraints. Off-resonance and gradient nonlinearity-induced geometric distortions were minimized or corrected prior to using images for RTP. A multidisciplinary MRI simulation guide, along with window width and level presets, was created to standardize use of MR images during RTP. A quality assurance program was implemented to maintain accuracy and repeatability of MRI simulation exams. Results: The combination of a large bore scanner, high field strength, and circumferentially wrapped, flexible phased array RF receive coils permitted acquisition of thin slice images with high contrast-to-noise ratio (CNR) and image intensity uniformity, while simultaneously accommodating patient setup and immobilization devices. Postprocessing corrections and alternative acquisition methods were required to reduce or correct off-resonance and gradient nonlinearity induced geometric distortions. Conclusions: The methodology described herein contains practical strategies the authors have implemented through lessons learned performing clinical MRI simulation exams. In their experience, these strategies provide robust, high fidelity, high contrast MR images suitable for external beam RTP.

60 APPLIED LIFE SCIENCES↗

SU-C-209-02: 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Clinical Patient Images

Purpose: We develop a method to generate time varying volumetric images (3D fluoroscopic images) using patient-specific motion models derived from four-dimensional cone-beam CT (4DCBCT). Methods: Motion models are derived by selecting one 4DCBCT phase as a reference image, and registering the remaining images to it. Principal component analysis (PCA) is performed on the resultant displacement vector fields (DVFs) to create a reduced set of PCA eigenvectors that capture the majority of respiratory motion. 3D fluoroscopic images are generated by optimizing the weights of the PCA eigenvectors iteratively through comparison of measured cone-beam projections and simulated projections generated from the motion model. This method was applied to images from five lung-cancer patients. The spatial accuracy of this method is evaluated by comparing landmark positions in the 3D fluoroscopic images to manually defined ground truth positions in the patient cone-beam projections. Results: 4DCBCT motion models were shown to accurately generate 3D fluoroscopic images when the patient cone-beam projections contained clearly visible structures moving with respiration (e.g., the diaphragm). When no moving anatomical structure was clearly visible in the projections, the 3D fluoroscopic images generated did not capture breathing deformations, and reverted to the reference image. For the subset of 3D fluoroscopic images generated from projections with visibly moving anatomy, the average tumor localization error and the 95th percentile were 1.6 mm and 3.1 mm respectively. Conclusion: This study showed that 4DCBCT-based 3D fluoroscopic images can accurately capture respiratory deformations in a patient dataset, so long as the cone-beam projections used contain visible structures that move with respiration. For clinical implementation of 3D fluoroscopic imaging for treatment verification, an imaging field of view (FOV) that contains visible structures moving with respiration should be selected. If no other appropriate structures are visible, the images should include the diaphragm. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

Production of Actinium-225 via High Energy Proton Induced Spallation of Thorium-232

The science of cancer research is currently expanding its use of alpha particle emitting radioisotopes. Coupled with the discovery and proliferation of molecular species that seek out and attach to tumors, new therapy and diagnostics are being developed to enhance the treatment of cancer and other diseases. This latest technology is commonly referred to as Alpha Immunotherapy (AIT). Actinium-225/Bismuth-213 is a parent/daughter alpha-emitting radioisotope pair that is highly sought after because of the potential for treating numerous diseases and its ability to be chemically compatible with many known and widely used carrier molecules (such as monoclonal antibodies and proteins/peptides). Unfortunately, the worldwide supply of actinium-225 is limited to about 1,000mCi annually and most of that is currently spoken for, thus limiting the ability of this radioisotope pair to enter into research and subsequently clinical trials. The route proposed herein utilizes high energy protons to produce actinium-225 via spallation of a thorium-232 target. As part of previous R and D efforts carried out at Argonne National Laboratory recently in support of the proposed US FRIB facility, it was shown that a very effective production mechanism for actinium-225 is spallation of thorium-232 by high energy proton beams. The base-line simulation for the production rate of actinium-225 by this reaction mechanism is 8E12 atoms per second at 200 MeV proton beam energy with 50 g/cm2 thorium target and 100 kW beam power. An irradiation of one actinium-225 half-life (10 days) produces {approx}100 Ci of actinium-225. For a given beam current the reaction cross section increases slightly with energy to about 400 MeV and then decreases slightly for beam energies in the several GeV regime. The object of this effort is to refine the simulations at proton beam energies of 400 MeV and above up to about 8 GeV. Once completed, the simulations will be experimentally verified using 400 MeV and 8 GeV protons available at Fermi National Accelerator Laboratory. Targets will be processed at Argonne National Laboratory to separate and purify the actinium-225 that will subsequently be transferred to NorthStar laboratory facilities for product quality testing and comparison to the product quality of ORNL produced actinium-225, which is currently the industry standard. The test irradiations at FNAL will produce 1-20 mCi per day which is more than sufficient for quantitative evaluation of the proposed production process. The beneficial outcome of this effort will be a new production route for actinium-225 that does not use or require any uranium-233 materials owned by DOE or use any radium-226 as an irradiation target but can supply the medical community's needs for actinium-225 now and in the future.

07 ISOTOPE AND RADIATION SOURCES↗

Calculation of the parameters of the X-ray diffraction station with adaptive segmented optics on the side beam from the wiggler of the Sibir'-2 storage ring

The mounting of an X-ray diffraction station on the side beam of a 19-pole superconducting wiggler makes it possible not only to use the central synchrotron radiation beam with a wavelength of 0.5 Angstrom-Sign , but also to solve problems requiring softer X rays at a synchrotron radiation (SR) intensity exceeding that for the beams from the bending magnet. A numerical simulation of the formation of photon beams from a source and their transmission through the elements of the station (and through the station as a whole) allows one to calculate the parameters of the station, compare it with the existing analogs, determine its potential and actual efficiency of its elements, and estimate the adjustment quality. A numerical simulation of the SR source on the side beam from the wiggler and the focusing channel (segmented condenser mirror, monochromator with sagittal focusing by the segmented second crystal, and segmented focusing mirror) has been performed. The sizes of the focus and the divergence of rays in it are determined with allowance for the finite sizes of segments. The intensity of radiation with a wavelength {lambda} = 1.0 Angstrom-Sign in the focus is determined taking into account the loss in the SR extraction channel and in the focusing channel. The values of the critical wavelength for the side beam from the wiggler and the wavelength resolution are calculated. The intensities in the X-ray diffraction pattern and its angular resolution are found.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Oscillatory instability development in extraction system of a negative ion source

Conditions of oscillatory instability development in the extraction system of a negative hydrogen ion source based on a volume-produced plasma are studied. Such an ion source is characterized by the presence of the parent gas in the extraction system due to the leakage from the gas-discharge chamber. The secondary electrons in the area of the ion-optical system become the reason of oscillation appearance and possible beam current modulation. Analytically the range of the stable beam propagation is found. The instability increment is shown to be rather small. Maximum increment of the oscillations corresponds to the beam velocity equal to the thermal velocity of plasma electrons. The group velocity of the oscillations is close to the beam velocity so the oscillations are convective. Simulation of the low energy beam propagation is performed in COMSOL Multiphysics, the beam current modulation being observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-Driven Coherent Betatron Oscillation in a Laser-Wakefield Cavity

The origin of beam disparity in emittance and betatron oscillation orbits, in and out of the polarization plane of the drive laser of laser-plasma accelerators, is explained in terms of betatron oscillations driven by the laser field. As trapped electrons accelerate, they move forward and interact with the laser pulse. For the bubble regime, a simple model is presented to describe this interaction in terms of a harmonic oscillator with a driving force from the laser and a restoring force from the plasma wake field. The resulting beam oscillations in the polarization plane, with period approximately the wavelength of the driving laser, increase emittance in that plane and cause microbunching of the beam. These effects are observed directly in 3D particle-in-cell simulations.

43 PARTICLE ACCELERATORS↗

Physics validation studies for muon collider detector background simulations

Within the broad discipline of physics, the study of the fundamental forces of nature and the most basic constituents of the universe belongs to the field of particle physics. While frequently referred to as 'high-energy physics,' or by the acronym 'HEP,' particle physics is not driven just by the quest for ever-greater energies in particle accelerators. Rather, particle physics is seen as having three distinct areas of focus: the cosmic, intensity, and energy frontiers. These three frontiers all provide different, but complementary, views of the basic building blocks of the universe. Currently, the energy frontier is the realm of hadron colliders like the Tevatron at Fermi National Accelerator Laboratory (Fermilab) or the Large Hadron Collider (LHC) at CERN. While the LHC is expected to be adequate for explorations up to 14 TeV for the next decade, the long development lead time for modern colliders necessitates research and development efforts in the present for the next generation of colliders. This paper focuses on one such next-generation machine: a muon collider. Specifically, this paper focuses on Monte Carlo simulations of beam-induced backgrounds vis-a-vis detector region contamination. Initial validation studies of a few muon collider physics background processes using G4beamline have been undertaken and results presented. While these investigations have revealed a number of hurdles to getting G4beamline up to the level of more established simulation suites, such as MARS, the close communication between us, as users, and the G4beamline developer, Tom Roberts, has allowed for rapid implementation of user-desired features. The main example of user-desired feature implementation, as it applies to this project, is Bethe-Heitler muon production. Regarding the neutron interaction issues, we continue to study the specifics of how GEANT4 implements nuclear interactions. The GEANT4 collaboration has been contacted regarding the minor discrepancies in the neutron interaction cross sections for boron. While corrections to the data files themselves are simple to implement and distribute, it is quite possible, however, that coding changes may be required in G4beamline or even in GEANT4 to fully correct nuclear interactions. Regardless, these studies are ongoing and future results will be reflected in updated releases of G4beamline.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Numerical Studies of Hall Thruster Acceleration Region Electron Transport

Azimuthal direction 1-D and azimuthal and axial direction 2-D Particle in Cell (PIC) simulations of the Hall thruster acceleration and near-plume regions are presented. The axial extent of the 2-D computational domain is based on the ExB drift parameter, 𝑫𝑬𝒙𝑩, the number of times around the channel an electron ExB drifts before being scattered. With only high energy main beam ions, the simulations produced a broad potential profile in the acceleration region. The addition of a small amount of ionization in the acceleration domain at a rate consistent with Hall thruster parameters causes the potential profile to develop two distinct regions. In the upstream portion of the computational domain, the potential profile is very steep, typical of Hall thruster acceleration regions. In the downstream portion, the potential profile is almost flat, like potentials in Hall thruster near plume regions. This bifurcation happens naturally; there is no other change in code parameters between the two results. Without the addition of a small amount of ionization in the acceleration region, the axial electron transport is very low. With ionization, the calculated ratio of electron current to ion current is the same order of those measured in Hall thrusters. This suggests that in regions with lower energy electrons and ions, plasma waves are effective in allowing crossfield transport, and axial electric fields are small. In the acceleration region, the plasma waves are less effective at scattering the energetic electrons, and high axial electric fields are needed to produce the observed cross-field electron transport.

Ortega, Alejandro Lopez↗

Whistler wave excitation and effects of self-focusing on ion beam propagation through a background plasma along a solenoidal magnetic field

This paper extends studies of ion beam transport through a background plasma along a solenoidal magnetic field by Kaganovich et al. [Phys. Plasmas 15, 103108 (2008)] to the important regime of moderate magnetic field strength satisfying omega{sub ce}>2beta{sub b}omega{sub pe}. Here, omega{sub ce} and omega{sub pe} are the electron cyclotron frequency and electron plasma frequency, respectively, and beta{sub b}=v{sub b}/c is the directed ion beam velocity normalized to the speed of light. The electromagnetic field perturbations excited by the ion beam pulse in this regime are calculated analytically and verified by comparison with the numerical simulations. The degrees of beam charge neutralization and current neutralization are estimated, and the transverse component of the Lorentz force associated with the excited electromagnetic field is calculated. It is found that the plasma response to the ion beam pulse is significantly different depending on whether the value of the solenoidal magnetic field is below or above the threshold value specified by omega{sub ce}{sup cr}=2beta{sub b}omega{sub pe}, and corresponding to the resonant excitation of large-amplitude whistler waves. The use of intense whistler wave excitations for diagnostic purposes is also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental exploration of compressed beam dynamics in an energy recovery linac with comparison to simulations

The compact energy recovery linac (cERL) has been developed for industrial applications since 2017. Applications such as free electron laser require a compressed beam with a small energy spread and transverse emittance. The typical operation energy of cERL is an intermediate energy region close to 17.5 MeV; therefore, the electron bunch is easily affected by the longitudinal space-charge effects and the coherent synchrotron radiation wakefield effects. Bunch compression is demonstrated by optimizing a combination of a longitudinally chirped electron bunch and the arcs with nonzero R 56 parameters. When the bunch compression procedure is applied for a bunch charge of 60 pC, an increase in energy spread is observed at the short bunch length. We systematically explored the chirp phase to determine the best condition. The measurement results of the energy spread, bunch length, and transverse emittance were compared with the tracking simulation results to understand the compressed beam dynamics.

47 OTHER INSTRUMENTATION↗

Cross-beam energy transfer in direct-drive ICF. II. Theory and simulation of mitigation through increased laser bandwidth

The response of the cross-beam energy transfer instability (CBET) to laser bandwidth is investigated through a combination of theory and simulation. Existing linear theory is generalized to treat broadband lasers, demonstrating that CBET is most effectively suppressed when the bandwidth exceeds the ion-acoustic wave (IAW) frequency. It is shown that for such bandwidths, reverse (seed to pump) transfer becomes possible, which reduces the net energy transfer rapidly as bandwidth is increased. The CBET gain exponent in this regime scales with bandwidth (Δω) as Δω−3 for Gaussian or Lorentzian laser spectra with different scalings possible for other spectra. Comparison of our theory with linearized fluid and particle-in-cell simulations, performed with the laser-plasma simulation environment (LPSE) and vector particle in cell (VPIC) codes, respectively, finds that the model is accurate in the absence of nonlinear processes. However, linear analysis also finds that the IAW energy density scales as Δω−1, implying that nonlinear effects may be more difficult to control than the CBET scaling would suggest. Indeed, nonlinear effects are found to be present in VPIC simulations with high-intensity lasers, despite minimal apparent CBET. Nonlinear processes in the VPIC cases include particle trapping, the two-ion wave decay, and ion wave self-focusing. In some high intensity VPIC cases, these effects lead to net energy transfer from seed to pump and increases to backscatter stimulated Brillouin scattering reflectivities. Finally, for a given bandwidth, we show that improved control of nonlinear processes can be achieved via smoothing by spectral dispersion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗