Search NASA⌕ Search

SEARCH · Search NASA

Results for “camera system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Technology Requirements for a Square Meter, Arcsecond Resolution Telescope for X-Rays: The SMART-X Mission

Addressing the astrophysical problems of the 2020's requires sub-arcsecond x-ray imaging with square meter effective area. Such requirements can be derived, for example, by considering deep x-ray surveys to find the young black holes in the early universe (large redshifts) which will grow into the first super-massive black holes. We have envisioned a mission, the Square Meter Arcsecond Resolution Telescope for X-rays (SMART-X), based on adjustable x-ray optics technology, incorporating mirrors with the required small ratio of mass to collecting area. We are pursuing technology which achieves sub-arcsecond resolution by on-orbit adjustment via thin film piezoelectric "cells" deposited directly on the non-reflecting sides of thin, slumped glass. While SMART-X will also incorporate state-of-the-art x-ray cameras, the remaining spacecraft systems have no requirements more stringent than those which are well understood and proven on the current Chandra X-ray Observatory.

Schwartz, Daniel A.↗

Crew-Aided Autonomous Navigation Project

Manual capability to perform star/planet-limb sightings provides a cheap, simple, and robust backup navigation source for exploration missions independent from the ground. Sextant sightings from spacecraft were first exercised in Gemini and flew as the loss-of-communications backup for all Apollo missions. This study seeks to procure and characterize error sources of navigation-grade sextants for feasibility of taking star and planetary limb sightings from inside a spacecraft. A series of similar studies was performed in the early/mid-1960s in preparation for Apollo missions, and one goal of this study is to modernize and update those findings. This technique has the potential to deliver significant risk mitigation, validation, and backup to more complex low-TRL automated systems under development involving cameras.

Holt, Greg↗

Comparison of Stereo-PIV and Plenoptic-PIV Measurements on the Wake of a Cylinder in NASA Ground Test Facilities.

A series of comparison experiments have been performed using a single-camera plenoptic PIV measurement system to ascertain the systems performance capabilities in terms of suitability for use in NASA ground test facilities. A proof-of-concept demonstration was performed in the Langley Advanced Measurements and Data Systems Branch 13-inch (33- cm) Subsonic Tunnel to examine the wake of a series of cylinders at a Reynolds number of 2500. Accompanying the plenoptic-PIV measurements were an ensemble of complementary stereo-PIV measurements. The stereo-PIV measurements were used as a truth measurement to assess the ability of the plenoptic-PIV system to capture relevant 3D/3C flow field features in the cylinder wake. Six individual tests were conducted as part of the test campaign using three different cylinder diameters mounted in two orientations in the tunnel test section. This work presents a comparison of measurements with the cylinders mounted horizontally (generating a 2D flow field in the x-y plane). Results show that in general the plenoptic-PIV measurements match those produced by the stereo-PIV system. However, discrepancies were observed in extracted pro les of the fuctuating velocity components. It is speculated that spatial smoothing of the vector fields in the stereo-PIV system could account for the observed differences. Nevertheless, the plenoptic-PIV system performed extremely well at capturing the flow field features of interest and can be considered a viable alternative to traditional PIV systems in smaller NASA ground test facilities with limited optical access.

Fahringer, Timothy W.↗

Enceladus Vent Explorer Concept

Our concept, Enceladus Vent Explorer (EVE), is a robotic pathfinder mission to enter these doors. EVE's goals are to descend into erupting conduits up to ~2 km deep, characterize the unknown interior structure of the vent-conduit system, assess the accessibility to the subsurface ocean through the vent-conduit system, potentially reach the liquid interface, and perform astrobiology and volcanology observations in the vent-conduit system. EVE sends two types of modules: Surface Module (SM) and Descent Module (DM). SM is a lander that stays on the surface, while tens of small (~3 kg, 10 cm in width and 30 cm in length) DMs separate from SM, move to a vent, and descend into it. DMs rely on a power and communication link provided by SM through a cable. As the payload volume of DM is extremely limited, each DM can carry only a single miniaturized instrument. This limitation is complemented by heterogeneity. There are several types of DMs, all of which share the common mobility system but carry different instruments. For example, a "scout DM" creates a 3-D map of the geyser system with its stereo cameras and structured light. A "sample return DM" collects particles and ice cores in the vent and deliver them to the mass spectrometer in the SM. An "in-situ science DM" carries science instruments, such as a microscopic imager and a microfluidics chip for biosignature detection. DMs are sent either sequentially or in parallel.

Enceladus↗

System design, modelling, and tracking filter for bearings only analog camera

In this paper, each subsystem of the Celestial Sensor is discussed with emphasis given to the filtering algorithms. The celestial sensor software processes sequential frame based bearing measurements on a peripheral CPY specifically designed for this application. A frame preprocessor is used to normalize each bearing measurement and apply a number of accept/reject rules. The accepted set of measurements is then passed to an Extended Kalman Filter (EKP) that is tuned to track the motion of the robot within the room.

Ahmed, Asif↗

Optical-Based Kinematic Positioning for Deep-Space Navigation

NASA’s Deep Space 1 mission demonstrated that a spacecraft can be navigated autonomously during deep-space cruise operations using only images of distant asteroids as measurements. This paper derives an approximation of the position estimate accuracy that can be achieved with this technique based on the assumption of multiple, simultaneous line-of-sight measurements. This achievable accuracy is computed for locations across the solar system, which can be used to estimate cruise navigation performance as a function of spacecraft trajectory. It is shown that a on-board optical navigation system can achieve kinematic position estimate accuracies of better than 100 km throughout the inner solar system with a highperformance camera and from many hundred to several thousand kilometers with a low-end camera. Beyond the main-asteroid belt, the feasibilty of this approach suffers due to lack of targets. A case-study implementation of this approach for the upcoming InSight mission to Mars is also presented.

Bhaskaran, Shyam↗

Thermal Vacuum Testing of a Modified COTS Camera for Lunar Environments

The primary objective of this study was to simulate lunar thermal environments to qualify a modified Commercial-Off-The-Shelf (COTS) camera for potential flight applications. A comprehensive testing regimen was developed, including both vacuum and thermal vacuum testing. The tests subjected the camera to temperatures corresponding to expected extrema, and thermal performance was recorded throughout the process. The testing demonstrated that both the camera and its thermal protection systems were able to maintain operational functionality under most of the simulated conditions. The results of the testing indicate that the implemented thermal protection system is effective for the expected lunar environments. Despite the decrease in operational time in comparison with terrestrial usage, the camera's overall performance supports its suitability for use in both flight and lunar missions.

Thermal↗

HyperMic

HyperMic is the control software for the Hyperspectral Confocal Microscope, and is required for the use of the microscope. It interfaces with, and controls the main subsystems of the microscope including the EMCCD detector, the video camera, the XYZ stage system, the optical shutters, the filter wheels, and the illumination sources. It allows the user to select regions to image, and acquire and save hyperspectral images. HyperMic is capable of acquiring single (2-dimensional) image frames or full 3-dimensional image stacks.

Sinclair, Michael 8↗

System and method for x-ray compatible 2D streak camera for a snapshot multiframe imager

The present disclosure is directed to a snapshot multiframe imager having an aperture element having at least one aperture, an adjacently positioned random mask, an imaging element and a computer. The random mask has a plurality of micron scale apertures and receives light passing through the aperture element, which represents the spatial information from the scene being imaged, and generates a plurality of image frames encoded in a spatial domain. The imaging element may operate in a drift-scan mode receives the encoded image frames and generates a streaked pattern of electrons representing a plurality of images of the scene at a plurality of different times. The computer analyzes the streaked pattern of electrons and mathematically reconstructs the plurality of images.

Dayton, Matthew S.↗

How Useful Are Imaging and Remote Sensing Technologies in Decontamination and Decommissioning? - 17363

The examples of application of imaging and remote sensing technologies during decontamination and decommissioning works in nuclear environment at Kurchatov Institute site are presented. The systems which realized these technologies are: radiometric system installed on mechanical arm of Brokk remote controlled vehicle, collimated scanning spectrometric system and portable gamma cameras of different types. Objects of application: facilities of research reactors at characterization and under dismantling, temporal radwaste storages during discharge and remediation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Acoustic levitator for containerless measurements on low temperature liquids

A single-axis acoustic levitator was constructed and used to levitate liquid and solid drops at temperatures from -40 to +40 C. The levitator consisted of: (i) two acoustic transducers mounted on a rigid vertical support that was bolted to an optical breadboard, (ii) a acoustic power supply that controlled acoustic intensity, relative phase of the drive to the transducers, and could modulate the acoustic forces at frequencies up to 1kHz, (iii) a video camera, and (iv) a system for providing a stream of controlled temperature gas flow over the sample. The acoustic transducers were operated at their resonant frequency of ~ 22 kHz and could produce sound pressure levels up to 160 dB. The force applied by the acoustic field could be modulated using a frequency generator to excite oscillations in the sample. Sample temperature was controlled using a modified Cryostream Plus and measured using thermocouples and an infrared thermal imager. The levitator was installed at x-ray beamline 11 ID-C at the Advanced Photon Source and used to investigate the structure of supercooled liquids.

Acoustic levitation↗

An automatic and accurate x-ray tube focal spot/grid alignment system for mobile radiography: System description and alignment accuracy

Purpose: A mobile radiography automatic grid alignment system (AGAS) has been developed by modifying a commercially available mobile unit. The objectives of this article are to describe the modifications and operation and to report on the accuracy with which the focal spot is aligned to the grid and the time required to achieve the alignment. Methods: The modifications include an optical target arm attached to the grid tunnel, a video camera attached to the collimator, a motion control system with six degrees of freedom to position the collimator and x-ray tube, and a computer to control the system. The video camera and computer determine the grid position, and then the motion control system drives the x-ray focal spot to the center of the grid focal axis. The accuracy of the alignment of the focal spot with the grid and the time required to achieve alignment were measured both in laboratory tests and in clinical use. Results: For a typical exam, the modified unit automatically aligns the focal spot with the grid in less than 10 s, with an accuracy of better than 4 mm. The results of the speed and accuracy tests in clinical use were similar to the results in laboratory tests. Comparison patient chest images are presented--one obtained with a standard mobile radiographic unit without a grid and the other obtained with the modified unit and a 15:1 grid. The 15:1 grid images demonstrate a marked improvement in image quality compared to the nongrid images with no increase in patient dose. Conclusions: The mobile radiography AGAS produces images of significantly improved quality compared to nongrid images with alignment times of less than 10 s and no increase in patient dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

Super-resolution with the Help of Active Camera

In a digital optical imaging system, image resolution is constrained by several factors, including focus plane array pitch and optics. Super-resolution approaches aim at overcoming some of these limits by incorporating additional information of the object and/or combining several pictures of the same object, taken with sub-pixel displacements between each other. As shown by some authors, the obtainable zoom factor using the second approach has an upper limit, determined by the signal-to-noise ratio of the image taken. Moreover, as discussed later in this paper, lines at some pitch are indistinguishable, further lowering this limit. Here, an approach to overcome this using active camera and employing images of different relative scales is introduced. The choice of these scales is commented. The results from two experiments, using simulated and real set-up are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Video Altimeter and Obstruction Detector for an Aircraft

Video-based altimetric and obstruction detection systems for aircraft have been partially developed. The hardware of a system of this type includes a downward-looking video camera, a video digitizer, a Global Positioning System receiver or other means of measuring the aircraft velocity relative to the ground, a gyroscope based or other attitude-determination subsystem, and a computer running altimetric and/or obstruction-detection software. From the digitized video data, the altimetric software computes the pixel velocity in an appropriate part of the video image and the corresponding angular relative motion of the ground within the field of view of the camera. Then by use of trigonometric relationships among the aircraft velocity, the attitude of the camera, the angular relative motion, and the altitude, the software computes the altitude. The obstruction-detection software performs somewhat similar calculations as part of a larger task in which it uses the pixel velocity data from the entire video image to compute a depth map, which can be correlated with a terrain map, showing locations of potential obstructions. The depth map can be used as real-time hazard display and/or to update an obstruction database.

Delgado, Frank J.↗

Radiological Survey of Contaminated Installations of Research Reactor before Dismantling in High Dose Conditions with Complex for Remote Measurements of Radioactivity - 12069

Decontamination and decommissioning of the research reactors MR (Testing Reactor) and RFT (Reactor of Physics and Technology) has recently been initiated in the National Research Center (NRC) 'Kurchatov institute', Moscow. These research reactors have a long history and many installations - nine loop facilities for experiments with different kinds of fuel. When decommissioning nuclear facilities it is necessary to measure the distribution of radioactive contamination in the rooms and at the equipment at high levels of background radiation. At 'Kurchatov Institute' some special remote control measuring systems were developed and they are applied during dismantling of the reactors MR and RFT. For a survey of high-level objects a radiometric system mounted on the robotic Brokk vehicle is used. This system has two (4π and collimated) dose meters and a high resolution video camera. Maximum measured dose rate for this system is ∼8.5 Sv/h. To determine the composition of contaminants, a portable spectrometric system is used. It is a remotely controlled, collimated detector for scanning the distribution of radioactive contamination. To obtain a detailed distribution of contamination a remote-controlled gamma camera is applied. For work at highly contaminated premises with non-uniform background radiation, another camera is equipped with rotating coded mask (coded aperture imaging). As a result, a new system of instruments for remote radioactivity measurements with wide range of sensitivity and angular resolution was developed. The experience and results of measurements in different areas of the reactor and at its loop installations, with emphasis on the radioactive survey of highly-contaminated samples, are presented. These activities are conducted under the Federal Program for Nuclear and Radiation Safety of Russia. Adaptation of complex remote measurements of radioactivity and survey of contaminated installations of research reactor before dismantling in high dose conditions has proven successful. The radioactivity measuring devices for operation at high, non-uniform dose background were tested in the field and a new data of measurement of contamination distribution in the premises and installations were obtained. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Large scale telescopes for high resolution X-ray and gamma-ray astronomy

This paper shows that angular-resolution, energy-range, and structural constraints on image-modulated X-ray telescopes are not fundamental and that the limits on angular resolution can be overcome by constructing such telescopes on a very large spatial scale. It is proposed that widely separated satellites be used for the modulating mask and detector array. Implementation of this concept is discussed in terms of a simple system consisting of a pinhole camera (i.e., a hole in an opaque mask on one subsatellite and a detector array on another). Advantages and problems of such systems are briefly discussed, and a solar X-ray telescope intended for deployment from a Shuttle orbiter is described. It is noted that such large-scale telescopes can be constructed to image gamma rays and even energetic neutrons as well.

Hudson, H. S.↗