Search NASA⌕ Search

SEARCH · Search NASA

Results for “cavity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Method for compression molding of thermosetting plastics utilizing a temperature gradient across the plastic to cure the article

A method is described for compression molding of thermosetting plastics composition. Heat is applied to the compressed load in a mold cavity and adjusted to hold molding temperature at the interface of the cavity surface and the compressed compound to produce a thermal front. This thermal front advances into the evacuated compound at mean right angles to the compression load and toward a thermal fence formed at the opposite surface of the compressed compound.

Heier, W. C.↗

Detector absorptivity measuring method and apparatus

A method and apparatus for measuring the absorptivity of a radiation detector by making the detector an integral part of a cavity radiometer are described. By substituting the detector for the surface of the cavity upon which the radiation first impinges a comparison is made between the quantity of radiation incident upon the detector and the quantity reflected from the detector. The difference between the two is a measurement of the amount of radiation absorbed by the detector.

Sheets, R. E.↗

[Activities of the Department of Electrical Engineering, Howard University]

Theoretical derivations, computer analysis and test data are provided to demonstrate that the cavity model is a feasible one to analyze thin-substrate, rectangular-patch microstrip antennas. Seven separate antennas were tested. Most of the antennas were designed to resonate at L-band frequencies (1-2 GHz). One antenna was designed to resonate at an S-band (2-4 GHz) frequency of 2.025 GHz. All dielectric substrates were made of Duroid, and were of varying thicknesses and relative dielectric constant values. Theoretical derivations to calculate radiated free space electromagnetic fields and antenna input impedance were performed. MATHEMATICA 2.2 software was used to generate Smith Chart input impedance plots, normalized relative power radiation plots and to perform other numerical manipulations. Network Analyzer tests were used to verify the data from the computer programming (such as input impedance and VSWR). Finally, tests were performed in an anechoic chamber to measure receive-mode polar power patterns in the E and H planes. Agreement between computer analysis and test data is presented. The antenna with the thickest substrate (e(sub r) = 2.33,62 mils thick) showed the worst match to theoretical impedance data. This is anticipated due to the fact that the cavity model generally loses accuracy when the dielectric substrate thickness exceeds 5% of the antenna's free space wavelength. A method of reducing computer execution time for impedance calculations is also presented.

Yalamanchili, Raj C.↗

Experimental Impedance of Single Liner Elements with Bias Flow

An experimental investigation was conducted to generate a high quality database, from which the effects of a mean bias flow on the acoustic impedance of lumped-element single-degree-of-freedom liners was determined. Acoustic impedance measurements were made using the standard two-microphone method in the NASA Langley Normal Incidence Tube. Each liner consisted of a perforated sheet with a constant-area cavity. Liner resistance was shown to increase and to become less frequency and sound pressure level dependent as the bias flow was increased. The resistance was also consistently lower for a negative bias flow (suction) than for a positive bias flow (blowing) of equal magnitude. The slope of the liner reactance decreased with increased flow.

Follet, J. I.↗

Systems and Methods for Fabricating Structures Including Metallic Glass-Based Materials Using Low Pressure Casting

Systems and methods to fabricate objects including metallic glass-based materials using low-pressure casting techniques are described. In one embodiment, a method of fabricating an object that includes a metallic glass-based material includes: introducing molten alloy into a mold cavity defined by a mold using a low enough pressure such that the molten alloy does not conform to features of the mold cavity that are smaller than 100 microns; and cooling the molten alloy such that it solidifies, the solid including a metallic glass-based material.

Hofmann, Douglas C.↗

Method for forming cooperative binary ionic solids

A nanostructured molecular unit and method for forming is described where a cationic porphyrin having an ethanolic substituent species and a metal in the porphyrin cavity is combined with an anionic porphyrin having a sulfonate substituent species and a metal in the porphyrin cavity to form by self-assembly a nanostructured molecular unit with a morphology comprising four dendritic elements connected at a central node.

36 MATERIALS SCIENCE↗

Method for forming cooperative binary ionic solids

A nanostructured molecular unit and method for forming is described where a cationic porphyrin having an ethanolic substituent species and a metal in the porphyrin cavity is combined with an anionic porphyrin having a sulfonate substituent species and a metal in the porphyrin cavity to form by self-assembly a nanostructured molecular unit with a morphology comprising four dendritic elements connected at a central node.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A proof-of-principle experiment of the ferroelectric tuner for the 1.3 GHz gun cavity

A novel ferroelectric frequency tuner was developed by the Ornega-P company and was tested at the Brookhaven National Laboratory on a 1.3 GHz RF cavity at room temperature. The tuner is based on the ferroelectric property of having a permittivity variable with an applied electric field. The achievable frequency tuning range can be estimated from the reactive impedance change due to an applied voltage via a S{sub 11} measurement at the tuner port. The frequency shift can be measured directly with a S{sub 21} measurement across the gun cavity with the tuner connected and activated. The frequency change due to an applied 5 kV obtained from the two methods is in reasonable agreement. The reactive impedance measurement yields a value in the range between 3.2 kHz and 14 kHz, while 9 kHz is the result from the direct measurement. The detail description of the experiment and the analysis will be discussed in the paper.

43 PARTICLE ACCELERATORS↗

Aperture and detector cavity considerations for wide and medium field-of-view radiometers

Design constraints regarding the ERBSS nonscanning radiometers are related to the necessity to exclude, as much as possible, unwanted radiation from the detectors. The usual approach to accomplish this is to provide an aperture which is both blackened and serrated on its interior surfaces. However, such an approach is not entirely satisfactory for a number of reasons. A somewhat different method to aperture design is, therefore, considered. This method minimizes the three sources of unwanted radiation and alleviates also the problem of aperture temperature variations. To achieve the potential accuracy of the considered type of radiometer, it is essential to design the cavity in such a way that any entering photon will experience at least five reflections before it is allowed to exit the radiometer. A number of feasible cavity configurations are considered.

Babcock, R. A.↗

Ground-state properties of microcavity polariton condensates at arbitrary excitation density

The ground state of microcavity polariton Bose-Einstein condensates (BEC's) is determined as a function of experimentally tunable parameters (the excitation density and the detuning of cavity photons), and also a material parameter (the ultraviolet cutoff). To obtain the ground state at an arbitrary excitation density, an interpolation method for the BEC-BCS crossover of excitonic insulators is extended to microcavity polariton systems in two or three dimensions. The ground state of the condensate changes from excitonic to photonic with an increase in the excitation density. This change is accompanied by several interesting features: (i) A laserlike input (excitation density) and output (photon density) relation with a sharp onset for largely detuned systems, which changes to that with a smooth onset for slightly detuned systems. (ii) The origin of the binding force of electron-hole pairs changes from Coulomb attraction to photon-mediated interactions, resulting in the formation of strongly bound pairs with a small radius, such as Frenkel excitons, in the photonic regime. The change in the ground state can be a crossover or a first-order transition, depending on the above-mentioned parameters, and is studied by plotting phase diagrams.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Repetition rate multiplication of frequency comb using all-pass fiber resonator

We propose a stable method for repetition rate multiplication of a 250-MHz Er-fiber frequency comb by a phase-locked all-pass fiber ring resonator, whose phase-locking configuration is simple. The optical path length of the fiber ring resonator is automatically controlled to be accurately an odd multiple of half of the original cavity length using an electronical phase-locking unit with an optical delay line. As for shorter cavity length of the comb, high-order odd multiple is preferable. Because the power loss depends only on the net-attenuation of the fiber ring resonator, the energetic efficiency of the proposed method is high. The input and output optical spectrums show that the spectral width of the frequency comb is clearly preserved. Besides, experimental results show less pulse intensity fluctuation and 35 dB suppression ratio of side-modes while providing a good long-term and short-term frequency stability. Higher-order repetition rate multiplication to several GHz can be obtained by using several fiber ring resonators in cascade configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reducing experimental uncertainty in the calculation of cavity swelling in a transmission electron microscope through crystallographically aided void volume tracking

Accurate measurement of cavity swelling in a transmission electron microscope is essential to define material performance under irradiation, and the conventionally applied spherical assumption for the calculation of cavity volumes in irradiated materials can result in errors ranging between a 25% underestimation and 72% overestimation of volume purely based on the assumption of shape. This assumption is undeniably expedient for calculation but does not sufficiently account for the 3D nature of polyhedral cavities and their shape projection in the transmission electron microscope, and therefore presents too large of an associated uncertainty in swelling determination for faceted cavities. This uncertainty has been defined for many common cavity shapes in FCC and BCC crystal systems, and has been tabulated across the cubic fundamental region. A revised methodology for crystallographically aided void volume tracking, or CAVV-T, is presented and demonstrated on a specimen of neutron irradiated Ni. In-depth discussion on the application of this technique is provided along with resources to allow for conversion between the spherical assumption and this revised method. This work seeks to increase experimental confidence in the characterization and quantification of critical aspects of irradiation damage in materials by applying a crystallographically-resolved approach for cavity swelling calculation.

Haag IV, James V. [Pacific Northwest National Labo↗

Electrical connectors including glass seals and methods of fabrication

An electrical connector comprises an outer shell, at least one pin, and an insulating seal. The outer shell includes at least one side wall defining a cavity and having an inner surface. The outer shell is formed from electrically conductive material. The pin is positioned within the cavity and is also formed from electrically conductive material. The insulating seal is configured to provide electrical isolation of the pin and fills the cavity between the inner surface of the side wall and the pin. The insulating seal is formed from glass doped with a transition metal oxide.

Eichorst, Dennis J.↗

Direct Numerical Simulation of Turbulent Flow Inside a Differentially Heated Composite Cavity

In this work, turbulent flow inside a modified differentially heated cavity at high Rayleigh number (Ra ~ 10 9 ) has been studied through fully resolved direct numerical simulation (DNS) using the high-order spectral element method code Nek5000. The flow configuration includes two separate physical phenomena: the natural recirculation itself, and the flow inside a curved channel. Simulations have been carried out using both the Boussinesq approximation and the low-Mach compressible formulation. Significant discrepancies between the two methods inform of the extreme caution that should be exercised when using the Boussinesq approximation in the limits of its applicability. The DNS solutions are analyzed in terms of polynomial-order convergence and Reynolds stress budgets, and the turbulence quantities and velocity profiles are presented as a reference for the validation of turbulence models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of External-Cavity Quantum Cascade Infrared Lasers to Nanosecond Time-Resolved Infrared Spectroscopy of Condensed-Phase Samples Following Pulse Radiolysis

Pulse radiolysis, utilizing short pulses of high-energy electrons from accelerators, is a powerful method for rapidly generating reduced or oxidized species and other free radicals in solution. Combined with fast time-resolved spectroscopic detection (typically in the ultraviolet/visible/near-infrared), it is invaluable for monitoring the reactivity of species subjected to radiolysis on timescales ranging from picoseconds to seconds. However, it is often difficult to identify the transient intermediates definitively due to a lack of structural information in the spectral bands. Time-resolved vibrational spectroscopy offers the structural specificity necessary for mechanistic investigations but has received only limited application in pulse radiolysis experiments. For example, time-resolved infrared (TRIR) spectroscopy has only been applied to a handful of gas-phase studies, limited mainly by several technical challenges. We have exploited recent developments in commercial external-cavity quantum cascade laser (EC-QCL) technology to construct a nanosecond TRIR apparatus that has allowed, for the first time, TRIR spectra to be recorded following pulse radiolysis of condensed-phase samples. Near single-shot sensitivity of DeltaOD <1 x 10(-3) has been achieved, with a response time of <20 ns. Using two continuous-wave EC-QCLs, the current apparatus covers a probe region from 1890-2084 cm(-1), and TRIR spectra are acquired on a point-by-point basis by recording transient absorption decay traces at specific IR wavelengths and combining these to generate spectral time slices. The utility of the apparatus has been demonstrated by monitoring the formation and decay of the one-electron reduced form of the CO(2) reduction catalyst, [Re(I)(bpy)(CO)(3)(CH(3)CN)](+), in acetonitrile with nanosecond time resolution following pulse radiolysis. Characteristic red-shifting of the nu(CO) IR bands confirmed that one-electron reduction of the complex took place. The availability of TRIR detection with high sensitivity opens up a wide range of mechanistic pulse radiolysis investigations that were previously difficult or impossible to perform with transient UV/visible detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurements and simulations of the optical gain and anti-reflection coating modal reflectivity in quantum cascade lasers with multiple active region stacks

We report spectrally resolved gain measurements and simulations for quantum cascade lasers (QCLs) composed of multiple heterogeneous stacks designed for broadband emission in the mid-infrared. The measurement method is first demonstrated on a reference single active region QCL based on a double-phonon resonance design emitting at 7.8 μm. It is then extended to a three-stack active region based on bound-to-continuum designs with a broadband emission range from 7.5 to 10.5 μm. A tight agreement is found with simulations based on a density matrix model. The latter implements exhaustive microscopic scattering and dephasing sources with virtually no fitting parameters. The quantitative agreement is furthermore assessed by measuring gain coefficients obtained by studying the threshold current dependence with the cavity length. These results are particularly relevant to understand fundamental gain mechanisms in complex semiconductor heterostructure QCLs and to move towards efficient gain engineering. Finally, the method is extended to the measurement of the modal reflectivity of an anti-reflection coating deposited on the front facet of the broadband QCL.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Kinetics of α-MnOOH Nanoparticle Formation through Enzymatically Catalyzed Biomineralization inside Apoferritin

While biomineralization in apoferritin has effectively synthesized highly monodispersed nanoparticles of various metal oxides and hydroxides, the detailed kinetics and mechanisms of Mn(III) (hydr)oxide formation inside apoferritin cavities have not been reported. To address this knowledge gap, we first identified the phase of solid Mn(III) formed inside apoferritin cavities as α-MnOOH. To analyze the oxidation and nucleation mechanism of α-MnOOH inside apoferritin by quantifying oxidized Mn, we used a colorimetric method with leucoberbelin blue (LBB) solution. In this method, LBB disassembled apoferritin by inducing an acidic pH environment, and reduced α-MnOOH nanoparticles. The LBB-enabled kinetic analyses of α-MnOOH nanoparticle formation suggested that the orders of reaction with respect to Mn2+ and OH– are 2 and 4, respectively, and α-MnOOH formation follows two-step pathways: First, soluble Mn2+ undergoes apoferritin-catalyzed oxidation at the ferroxidase dinuclear center, forming a Mn(III)-protein complex, P-[Mn2O2(OH)2]. Second, the oxidized Mn(III) dissociates from the protein binding sites and is subsequently nucleated to form α-MnOOH nanoparticles in the apoferritin cavities. This study reveals key kinetics and mechanistic information on the Mn-apoferritin systems, and the results facilitate applications of apoferritin as a means of nanomaterial synthesis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Dynamic Tumor Bed: Volumetric Changes in the Lumpectomy Cavity During Breast-Conserving Therapy

Purpose: To characterize the magnitude of volume change in the postoperative tumor bed before and during radiotherapy, and to identify any factors associated with large volumetric change. Methods and Materials: Thirty-six consecutive patients with early-stage or preinvasive breast cancer underwent breast-conserving therapy at our institution between June 2006 and October 2007. Computed tomography (CT) scans of the breast were obtained shortly after surgery, before the start of radiotherapy (RT) for treatment planning, and, if applicable, before the tumor bed boost. Postoperative changes, seroma, and surgical clips were used to define the tumor bed through consensus agreement of 3 observers (B.P., D.I., and J.L.). Multiple variables were examined for correlation with volumetric change. Results: Between the first and last scan obtained (median time, 7.2 weeks), the tumor bed volume decreased at least 20% in 86% of patients (n = 31) and at least 50% in 64% of patients (n = 23). From the postoperative scan to the planning scan (median time, 3 weeks), the tumor bed volume decreased by an average of 49.9%, or approximately 2.1% per postoperative day. From planning scan to boost scan (median interval, 7 weeks), the median tumor bed volume decreased by 44.6%, at an average rate of 0.95% per postoperative day. No single factor was significantly associated with a change in tumor bed volume greater than 20%. Conclusions: The average postlumpectomy cavity undergoes dramatic volumetric change after surgery and continues this change during RT. The rate of change is inversely proportional to the duration from surgery. In this study no factors studied predicted large volumetric change.

62 RADIOLOGY AND NUCLEAR MEDICINE↗