Search NASA⌕ Search

SEARCH · Search NASA

Results for “continuous control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

FPGA-Based Spill Regulation System for the Muon Delivery Ring at Fermilab

The Muon to Electron Experiment (\acrshort{Mu2e}) requires a uniform beam profile from the Muon Delivery Ring to meet their experimental needs. A specialized Spill Regulation System (\acrshort{SRS}) has been developed to help achieve consistent spill uniformity. The system is based on a custom-designed carrier board featuring an Arria 10 SoC, capable of executing real-time feedback control. The FPGA processes beam pulses of approximately 200 ns every 1.695 microseconds, allowing for continuous monitoring of the extracted spill intensity through fast bunch integration. The system directly controls three quadrupole magnets, which work in conjunction with sextupole magnets to achieve third-order resonant extraction. Furthermore, the board interfaces with Fermilab s Accelerator Control Network (ACNET), enabling operators to modify spill regulation settings in real-time via the control network while providing diagnostic waveforms. These waveforms help operators monitor the process and fine-tune the feedback mechanisms. This paper presents an overview of the board's architecture and its initial progress toward regulating beam extraction. This initial version of the regulation system aims to evaluate baseline performance to inform future system improvements.

Berlioz, Jose Rene [Fermilab]↗

An application of adaptive learning to malfunction recovery

A self-organizing controller is developed for a simplified two-dimensional aircraft model. The Controller learns how to pilot the aircraft through a navigational mission without exceeding pre-established position and velocity limits. The controller pilots the aircraft by activating one of eight directional actuators at all times. By continually monitoring the aircraft's position and velocity with respect to the mission, the controller progressively modifies its decision rules to improve the aircraft's performance. When the controller has learned how to pilot the aircraft, two actuators fail permanently. Despite this malfunction, the controller regains proficiency at its original task. The experimental results reported show the controller's capabilities for self-organizing control, learning, and malfunction recovery.

Cruz, R. E.↗

Modeling a Large Submillimeter-Wave Observatory

The 25 meter aperture Cornell Caltech Atacama Telescope (CCAT) will provide an enormous increase in sensitivity in the submillimeter bands compared to existing observatories, provided it can establish and maintain excellent image quality. To accomplish this at a very low cost, it is necessary to conduct accurate engineering trades, including the most effective segment and wavefront sensing and control approach, to determine the best method for continuously maintaining wavefront quality in the operational environment. We describe an integrated structural/optical/controls model that provides accurate performance prediction. We also detail the analysis methods used to quantify critical design trades.

Segment Sensing↗

Fuel Property Effects of a Broad Range of Potential Biofuels on Mixing Control Compression Ignition Engine Performance and Emissions

Conventional diesel engines will continue to hold a vital role in the heavy- and medium-duty markets for the transportation of goods along with many other uses. The ability to offset traditional diesel fuels with low-net-carbon biofuels could have a significant impact on reducing the carbon footprint of these vehicles. A prior study screened several hundred candidate biofuel blendstocks based on required diesel blendstock properties and identified 12 as the most promising. Eight representative biofuel blendstocks were blended at a 30% volumetric concentration with EPA certification ultra-low-sulfur diesel (ULSD) and were investigated for emissions and fuel efficiency performance. This study used a single cylinder engine (based on the Ford 6.7L engine) using Conventional Diesel Combustion (CDC), also known as Mixing Control Compression Ignition (MCCI). The density, cetane number, distillation curve and sooting tendency (using the yield sooting index method) of the fuels were measured. Start of injection (SOI) timing and exhaust gas recirculation (EGR) sweeps were conducted at three separate speed-load operating points to examine fuel effects on the NOX/soot and NOX/efficiency trade-offs as well as to evaluate EGR tolerance. The results show that the biofuel blends all reduced NOX and soot emissions without penalty to engine efficiency, even improving efficiency for some of the blends at certain points, with one particular blend of polyoxymethylene ethers (POMEs) improving efficiency at all points while drastically reducing soot by 79%.

47 OTHER INSTRUMENTATION↗

Structural switching dynamically controls the doubly pseudoknotted Rous sarcoma virus–programmed ribosomal frameshifting element

A hallmark of retrovirus replication is the translation of two different polyproteins from one RNA through programmed –1 frameshifting. This is a mechanism in which the actively translating ribosome is induced to slip in the 5′ direction at a defined codon and then continues translating in the new reading frame. Programmed frameshifting controls the stoichiometry of viral proteins and is therefore under stringent evolutionary selection. Forty years ago, the first frameshifting stimulatory element was discovered in the Rous sarcoma virus. The ~120 nt RNA segment was predicted to contain a pseudoknot, but its 3D structure has remained elusive. Now, we have determined cryoEM and X-ray crystallographic structures of this classic retroviral element, finding that it adopts a butterfly-like double-pseudoknot fold. One “wing” contains a dynamic pyrimidine-rich helix, observed crystallographically in two conformations and in a third conformation via cryoEM. The other wing encompasses the predicted pseudoknot, which interacts with a second unexpected pseudoknot through a toggle residue, A2546. This key purine switches conformations between structural states and tunes the stability of interacting residues in the two wings. We find that its mutation can modulate frameshifting by as much as 50-fold, likely by altering the relative abundance of different structural states in the conformational ensemble of the RNA. Taken together, our structure–function analyses reveal how a dynamic double pseudoknot junction stimulates frameshifting by taking advantage of conformational heterogeneity, supporting a multistate model in which high Shannon entropy enhances frameshifting efficiency.

Science & Technology - Other Topics↗

Practical factors of envelope model setup and their effects on the performance of model predictive control for building heating, ventilating, and air conditioning systems

Model predictive control (MPC) for buildings is attracting significant attention in research and industry due to its potential to address a number of challenges facing the building industry, including energy cost reduction, grid integration, and occupant connectivity. However, the strategy has not yet been implemented at any scale, largely due to the significant effort required to configure and calibrate the model used in the MPC controller. While many studies have focused on methods to expedite model configuration and improve model accuracy, few have studied the impact a wide range of factors have on the accuracy of the resulting model. In addition, few have continued on to analyze these factors’ impact on MPC controller performance in terms of final operating costs. Therefore, this study first identifies the practical factors affecting model setup, specifically focusing on the thermal envelope. The seven that are identified are building design, model structure, model order, data set, data quality, identification algorithm and initial guesses, and software tool-chain. Then, through a large number of trials, it analyzes each factor's influence on model accuracy, focusing on grey-box models for a single zone building envelope. Finally, this study implements a subset of the models identified with these factor variations in heating, ventilating, and air conditioning MPC controllers, and tests them in simulation of a representative case that aims to optimally cool a single-zone building with time-varying electricity prices. It is found that a difference of up to 20%25 in cooling cost for the cases studied can occur between the best performing model and the worst performing model. The primary factors attributing to this were model structure and initial parameter guesses during parameter estimation of the model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-Term Stewardship at a Former Uranium Mill Tailings Site in Riverton, Wyoming WM2017-17090

The US Department of Energy Office of Legacy Management (LM) is responsible for maintaining protective public health and environmental conditions at former uranium mill tailings sites nationwide via long-term stewardship. One of these sites, a former uranium mill near Riverton, Wyoming, is within the boundary of the Wind River Indian Reservation and operated from 1958 to 1963. Tailings and contaminated material associated with mill operations were removed and transported to an offsite disposal cell in 1989. The remedial action was completed under Title I of the Uranium Mill Tailings Radiation Control Act of 1978. Milling operations, which included an unlined tailings impoundment and an unlined evaporation pond, contaminated the shallow groundwater, resulting in a downgradient groundwater plume that discharges to the Little Wind River. A natural flushing compliance strategy was implemented in 1998. This strategy allows contaminants of concern to naturally flush from the groundwater, provided that contaminants flush below US Environmental Protection Agency maximum concentration limits within 100 years. As part of the compliance strategy, LM has implemented a groundwater monitoring program along with institutional controls that include the installation of an alternate water supply, continued sampling of private wells, and restrictions on well drilling and gravel pit construction. LM works closely with local stakeholders and community members to ensure that these institutional controls are in place and maintained. The Riverton site provides an interesting case study where contaminant remobilization due to river flooding prompted a reevaluation of the conceptual site model to verify if the current compliance strategy would remain protective of human health and the environment. Concentrations of groundwater contaminants, which include sulfate, molybdenum, and uranium, were transiently elevated following flooding of the Little Wind River in 2010 and 2016. These flood events provided the impetus to investigate other aspects of the hydrologic system, including the unsaturated zone, naturally reduced (sulfidic) zones, and evaporite deposits. New site conceptual models, field and laboratory studies, and numerical models are being developed to explain how biogeochemical sediment–water interactions contribute to plume persistence and flood-related increases in groundwater concentrations. Updated human health and ecological risk assessments are progressing to evaluate the risk to human health and the environment based on current site conditions. Groundwater concentrations may remain above US Environmental Protection Agency maximum concentration limits beyond the 100-year natural flushing regulatory time frame. LM in its capacity as a long-term steward continues to monitor the site to ensure protectiveness is maintained and to determine the feasibility of alternative compliance and remediation strategies.

54 ENVIRONMENTAL SCIENCES↗

Long-Term Stewardship at a Former Uranium Mill Tailings Site in Riverton, Wyoming - 17090

The US Department of Energy Office of Legacy Management (LM) is responsible for maintaining protective public health and environmental conditions at former uranium mill tailings sites nationwide via long-term stewardship. One of these sites, a former uranium mill near Riverton, Wyoming, is within the boundary of the Wind River Indian Reservation and operated from 1958 to 1963. Tailings and contaminated material associated with mill operations were removed and transported to an offsite disposal cell in 1989. The remedial action was completed under Title I of the Uranium Mill Tailings Radiation Control Act of 1978. Milling operations, which included an unlined tailings impoundment and an unlined evaporation pond, contaminated the shallow groundwater, resulting in a down-gradient groundwater plume that discharges to the Little Wind River. A natural flushing compliance strategy was implemented in 1998. This strategy allows contaminants of concern to naturally flush from the groundwater, provided that contaminants flush below US Environmental Protection Agency maximum concentration limits within 100 years. As part of the compliance strategy, LM has implemented a groundwater monitoring program along with institutional controls that include the installation of an alternate water supply, continued sampling of private wells, and restrictions on well drilling and gravel pit construction. LM works closely with local stakeholders and community members to ensure that these institutional controls are in place and maintained. The Riverton site provides an interesting case study where contaminant remobilization due to river flooding prompted a reevaluation of the conceptual site model to verify if the current compliance strategy would remain protective of human health and the environment. Concentrations of groundwater contaminants, which include sulfate, molybdenum, and uranium, were transiently elevated following flooding of the Little Wind River in 2010 and 2016. These flood events provided the impetus to investigate other aspects of the hydrologic system, including the unsaturated zone, naturally reduced (sulfidic) zones, and evaporite deposits. New site conceptual models, field and laboratory studies, and numerical models are being developed to explain how biogeochemical sediment-water interactions contribute to plume persistence and flood-related increases in groundwater concentrations. Updated human health and ecological risk assessments are progressing to evaluate the risk to human health and the environment based on current site conditions. Groundwater concentrations may remain above US Environmental Protection Agency maximum concentration limits beyond the 100-year natural flushing regulatory time frame. LM in its capacity as a long-term steward continues to monitor the site to ensure protectiveness is maintained and to determine the feasibility of alternative compliance and remediation strategies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SHARP pre-release v1.0 - Current Status and Documentation

The NEAMS Reactor Product Line effort aims to develop an integrated multiphysics simulation capability for the design and analysis of future generations of nuclear power plants. The Reactor Product Line code suite’s multi-resolution hierarchy is being designed to ultimately span the full range of length and time scales present in relevant reactor design and safety analyses, as well as scale from desktop to petaflop computing platforms. In this report, building on a several previous report issued in September 2014, we describe our continued efforts to integrate thermal/hydraulics, neutronics, and structural mechanics modeling codes to perform coupled analysis of a representative fast sodium-cooled reactor core in preparation for a unified release of the toolkit. The work reported in the current document covers the software engineering aspects of managing the entire stack of components in the SHARP toolkit and the continuous integration efforts ongoing to prepare a release candidate for interested reactor analysis users. Here we report on the continued integration effort of PROTEUS/Nek5000 and Diablo into the NEAMS framework and the software processes that enable users to utilize the capabilities without losing scientific productivity. Due to the complexity of the individual modules and their necessary/optional dependency library chain, we focus on the configuration and build aspects for the SHARP toolkit, which includes capability to autodownload dependencies and configure/install with optimal flags in an architecture-aware fashion. Such complexity is untenable without strong software engineering processes such as source management, source control, change reviews, unit tests, integration tests and continuous test suites. Details on these processes are provided in the report as a building step for a SHARP user guide that will accompany the first release, expected by Mar 2016.

Mahadevan, Vijay S.↗

Slat Noise Control Using a Slat Gap Filler

The leading edge slat of a high-lift system is one of the main noise contributors on many commercial aircraft during approach. This paper continues our previous studies on the gap filler for passive noise control on the 30P30N high-lift airfoil. An improved implementation of the gap filler was applied to minimize the effects of flow leakage encountered in the previous work, which resulted in spurious noise content in the far-field acoustic spectra. To evaluate the effect of passive flow control on the acoustics generated by the unsteady flow field, anechoic wind tunnel experiments are conducted on the two-dimensional, three-element high-lift airfoil with a gap filler mounted to the slat. The slat geometry modification associated with the gap filler alters the flow field in the cove region that dominates the generation of the acoustic field. A single angle of attack (훼푘=8◦) and three flow speeds corresponding to Reynolds numbersof푅푒푐=1.2푒6,1.5푒6, and1.71푒6are selected as the test conditions. Steady surface pressure measurements are conducted to assess the effect of the treatments on the overall lift. Acoustic array measurements are used to evaluate the influence of the gap filler on the radiated noise. Delay and Sum beamforming is applied to locate the noise sources on the model and to provide the integrated spectra. The gap filler is found to eliminate the narrowband peaks in the acoustic spectra and, also, to yield a 10 dB reduction in the broadband noise in comparison with the baseline case. Time-resolved Particle Image Velocimetry results show that the flow features are significantly altered with the presence of the gap filler, which leads to a more stable slat cove shear layer and, thus, to weaker pressure and velocity fluctuations.

Yang Zhang↗

Liquid Motion Experiment Flown on STS-84

During some part or all of each mission, about half of all scientific and commercial spacecraft will spin. For example, commercial spacecraft are made to spin during the transfer maneuver from low Earth orbit to the mission orbit to obtain gyroscopic stiffness. Many spacecraft spin continuously in orbit for the same reason. Other reasons for spinning include controlling the location of liquid propellants within their tanks and distributing solar heat loads. Although spinning has many benefits, it also creates problems because of the unavoidable wobble motion that accompanies spinning. Wobbling makes the spacecraft's flexible components oscillate. The energy dissipated by the internal friction of these components causes the wobbling amplitude to increase continually until, at some point, the attitude control thrusters must be fired to bring the spacecraft's amplitude back to an acceptable level.

Dalton, Penni J.↗

Vasopressin release induced by water deprivation - Effects of centrally administered saralasin

Uncertainty exists as to whether endogenous angiotensin activates brain mechanisms controlling vasopressin (AVP) secretion during dehydration. Various doses of saralasin were injected into a lateral cgrebroventricle (IVT) of conscious, male rats deprived of water for 48 h. The rats were killed at different times. The concentration of AVP in the plasma p(AVP), measured by radioimmunoassay, was unaffected by saralasin. IVT pretreatment with 1-Sar-8-Ile-angiotensin II blocked maximal AVP release by IVT angiotensin, but this pretreatment did not reduce p(AVP) after 24, 48 or 72 hr water deprivation. A 3-hour continuous IVT infusion of CSF or saralasin (10 micrograms/hour) into 48-hour water-deprived rats revealed equivalent p(AVP) concentration and urine volumes. When the infusions were continued for 3 h more with water available, control and saralasin-treated rats: (1) drank at similar rates, (2) excreted similar amounts of urine, and (3) reduced their p(AVP) concentration levels to the same extent. IVT saralasin did not affect p(AVP) concentration of rats dehydrated with hypertonic NaCl. Combined IVT saralasin and atropine reduced p(AVP) concentration of 48-hour water deprived rats about 30 percent (p less than 0.05). It is concluded that redundancy exists for sensing, integrating and releasing vasopressin in dehydrated rats.

Keil, L. C.↗

Design of a pilot scale directly irradiated, high temperature, and low pressure moving particle cavity chamber for metal oxide reduction

Recently a novel design concept of a reactor—the cascading pressure reactor—for the thermochemical fuel production, using a solar-driven redox cycle, was proposed. In this concept, thermal reduction of metal oxide particles is completed in multiple stages, at successively lower pressures. This leads to an order of magnitude decrease in the pumping power demand as compared to a single stage, which in turn increases the solar to fuel efficiency. An important step in the process is the transfer of heat in the form of concentrated solar radiation to the particles, while providing reducing conditions in the space surrounding the particles. In this context, a novel system for heating and reducing particles, with a focus on operating at the small prototype scale (below 20 kW), is investigated. The key goals of the system are continuous operation, uniform heating of the reactive material, the ability to heat reactive material to 1723 K or higher, and flexibility of control. These criteria have led to the conceptual design of a continuous thin-layer particle conveyor, contained in an apertured, windowed cavity and enclosed in a vacuum chamber. This chamber, in combination with a water-splitting chamber and other system components, allows the possibility of testing multiple redox materials without any significant change in the reactor design. The present work shows a potential design for the proposed component, feasibility tests of the physics of moving particles with relevant materials, and series of interconnected numerical models and calculations that can be used to size such a system for the appropriate scales of power and mass flow rates. The use of a unified design strategy has led to efficient development of the system. Experimental investigations of the horizontal motion plate allowed effective determination of motion profiles and bed uniformity. We note the most important factors determined through the modeling effort were the aperture diameter, which serves as the coupling point between the solar simulator lamp array and the cavity particle heating, and the particle bed thickness, which has a strong effect on the outlet temperature of the particles.

42 ENGINEERING↗

Flying qualities criteria and flight control design

Despite the application of sophisticated design methodology, newly introduced aircraft continue to suffer from basic flying qualities deficiencies. Two recent meetings, the DOD/NASA Workshop on Highly Augmented Aircraft Criteria and the NASA Dryden Flight Research Center/Air Force Flight Test Center/AIAA Pilot Induced Oscillation Workshop, addressed this problem. An overview of these meetings is provided from the point of view of the relationship between flying qualities criteria and flight control system design. Among the items discussed are flying qualities criteria development, the role of simulation, and communication between flying qualities specialists and control system designers.

Berry, D. T.↗

WGRID-49 GMLC Project Report: Understanding the Role of Short-Term Energy Storage and Large Motor Loads for Active Power Controls by Wind Power

The GMLC project is built upon the results of pioneering research funded by the U.S. Department of Energy (DOE) and conducted by the National Renewable Energy Laboratory (NREL)—in collaboration with the Electric Power Research Institute and the University of Colorado—on active power controls (APC) by wind power during 2013–2016. The studies detailed in the first APC by wind power project have shown tremendous promise for the potential for wind power plants to provide APC. The goal of this project was to continue the previous work and develop and validate coordinated controls of APC by wind generation, short-term energy storage, and large industrial motor drives for providing various types of ancillary services to the grid and minimizing loading impacts on wind turbines (e.g., drivetrains), thereby reducing operation-and-maintenance (O&M) costs and subsequently reducing the cost of energy generated by wind power. This work used the $30 million, multiyear DOE investments and the unique characteristics of NREL’s existing National Wind Technology Center test site, including a combination of multimegawatt utility-scale wind turbine generators, a 1-MW/1-MWh battery energy storage system (BESS), industrial variable-frequency motor drives, a 1-MW solar photovoltaic (PV) array, and a 7-MVA controllable grid interface. This combination of technologies allows for the optimization, testing, and demonstration of various types of APC by wind power in coordination with other generation sources (including regenerative loads) and energy storage to allow for enhancing or, in some cases, substituting the APC services by wind power and reducing impacts on wind turbine component life and thus increasing the availability and reliability of the power supply from wind

17 WIND ENERGY↗

Evaluating Process Effectiveness to Reduce Risk

It is well documented that government agencies do not have the same incentive as the private sector to focus on process effectiveness and continual improvement of those processes. It is also well documented whenever government agencies fail to deliver efficient, effective, consistent, and fair services to the citizens. In spite of the various "reinventing government" and "effectiveness initiatives" of the past decades, and in spite of the efforts on the part of many agencies to improve, government in general still lags behind industry in creating a culture of effective processes and systems. While the tragic events that unfolded recently in Flint, Michigan, teach us that running government "like a business" does not always take the needs of the citizenry into account, there are many lessons and techniques from the private sector that government agencies can use to improve. The incentive to improve, while mandated by various administrations1, needs to come from within the workforce, in order to effectively take root. The best, most effective incentive is to reduce, control or eliminate risk. Government agencies face some of the same risks as the private sector, while some are unique. While ISO 310002 has been around since 2009, risk has taken on increased visibility within the private sector with the advent of the emphasis on risk-based thinking in ISO 9001:20153. The relationship between risk-based thinking and effective processes is simple and direct. Those processes that are well thought out and standardized (i.e. Plan-Do-Check-Act), will have taken into account the applicable policy, statutory, regulatory, safety, quality and technical parameters, which may not occur to someone performing the process with minimal experience or training; and thus protect the employees, the public and the agency from statutory and regulatory violations; delay in providing services; non-delivery of services; harm to public or employee safety and health; cost overruns; breaches in security; loss of confidence in government; failure of publicly funded projects; damage to the environment; ethics violations, and the list goes on; with local, national and even international consequences. The Plan-Do-Check-Act process, also known as the "process approach" can be used at any time to establish and standardize a process, and it can also be used to check periodically for "process creep" (i.e., informal, unauthorized changes that have occurred over time), any necessary updates and improvements. While ISO 9001 compliance is not mandated for all government agencies, if interpreted correctly, it can be useful in establishing a framework and implementing effective management systems and processes.4 Another method that can be used to evaluate effectiveness is the scorecard definitions in Mallory's Process Management Standard5 as a basis for evaluating work on the process level on effective, and continuously improved and improving processes. With processes on the lower end of the scale, agencies are vulnerable to a great many risks, with employees and managers making up many of the rules as they go, leading to the above listed negative results. Without clear guidance for nominal operations, off-nominal situations can, and do, increase the likelihood of chaos. In an increasingly technical environment, with inter-agency communication and collaboration becoming the norm, agencies need to come to grips with the fact that processes can become rapidly outdated, and that the technical community should take on an increased role in the maturation of the agency's processes. Industry has long known that effective processes are also efficient, and process improvement methods such as Kaizen, Lean, Six Sigma, 5S, and mistake proofing lead to increased productivity, improved quality, and decreased cost. Again, government agencies have different concerns, but inefficiencies and mistakes can have dire and wide reaching consequences for the public that they serve. While no one goes to work planning to cause harm, it is up to agencies to establish upper level systems, which make establishment and compliance with processes possible. Again, Mallory provides us with a Systems Management Standard6, similar to the Process Management Standard, with a scale of 0-5 for systems effectiveness and maturity. Deming determined that "eighty-five percent of the reasons for failure are deficiencies in the systems and process rather than the employee. The role of management is to change the process rather than badgering individual employees to do better." 7 It is not just the working level employees who need effective processes, but the mid-and upper level managers as well. A disciplined management culture sets the tone for the employees, aids both routine and off-nominal decision-making, and incorporates risk -based thinking into the systems and processes as a matter of normal activity. Figure 1, illustrates the relationship between ineffective and effective processes and risk, through the use of the "stoplight" colors that are commonly used to show serious situations (red), situations which may be improving or deteriorating depending on trends (yellow), and situations that are under control and continuously improved (green).

Shepherd, Christena C.↗

Broadband‐Tunable Third‐Harmonic Generation Using Phase‐Change Chalcogenides

Despite remarkable progress in passive nonlinear nanophotonics, dynamically controlled ultracompact nonlinear optical sources with high efficiency remain elusive. Nonvolatility, large refractive index contrast between amorphous and crystalline phases, low thermal threshold for crystallization, and particularly high‐third‐order nonlinear optical susceptibility of phase‐change alloy Ge 2 Sb 2 Te 5 (GST) make it a promising candidate for active subwavelength metaphotonic structures for realization of third‐harmonic generation (THG) devices. Herein, a GST‐based asymmetric Fabry–Perot cavity is numerically designed and experimentally demonstrated to show a dynamically reconfigurable structure with a large shift of the THG resonant band. In addition, continuous resonant spectral shifting bridged by a precisely controlled semicrystalline phase of GST is realized. Tunable THG with the fundamental wavelength ranging from 1150 to 1400 nm is presented, which corresponds to a broadband THG source in the violet‐blue visible wavelength range. Herein, the potential of GST subwavelength structures as a reliable platform for realization of the broadband‐tunable frequency‐conversion sources for applications such as THG microscopy and optical communication is indicated.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Identifying Common Coordination Procedures across Extensible Traffic Management (xTM) to Integrate xTM Operations into the National Airspace System

New categories of missions and vehicle types, such as drone delivery services, on-demand air taxi, and high-altitude long-endurance (HALE) vehicles are being proposed to operate using a novel, highly automated information exchange infrastructure and a community-based, cooperative traffic management concept. Collectively, these new operations are called Extensible Traffic Management (xTM). As these xTM vehicles become more prevalent, their operations will increasingly overlap with existing conventional aircraft and with each other. In order to seamlessly co-exist with current conventional aircraft operations, new coordination procedures, tools and services will be needed to integrate xTM into the future National Airspace System (NAS). In our prior work, we have identified a set of use cases for xTM interactions with air traffic control (ATC), categorized across different xTM operations based on trigger events. Events consisted of ones such as nominal xTM vehicle transition into the ATC environment or an off-nominal emergency landing situation. In this paper, we have extended the prior work to identify commonalities in the coordination procedures across xTM, as well as differences that are specific to the individual xTM operations. The overall results showed that two types of xTM-ATC interactions were prevalent: 1) xTM vehicles transitioning between xTM and ATC operational environments; 2) xTM vehicles being allowed to continue xTM operations in areas that are normally controlled by ATC. The results also suggested that emergency and rare off-nominal events may need specialized procedures for each vehicle type. The overall results suggest that there is a pathway to define a common method of handling and integrating diverse xTM operations in the future NAS, but there need to be procedures for individualized handling of xTM vehicles in infrequent, safety-critical events.

Extensible Traffic Management (xTM)↗