Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Diffractive-refractive optics: X-ray collimator

Diffractive-refractive optics are x-ray focusing monochromators based on the diffraction on profiled crystal surface. Diffraction on longitudinal parabolic groove machined in crystal surface forms a sagittaly focused synchrotron radiation beam. Such kind of monochromator may be realized as a crystal with parabolic hole, where the beam is diffracted on the inner wall of the hole. Two such asymmetrically cut crystals set into antiparallel position, creating a dispersive (+,-,-,+) arrangement, form a sagittaly focusing x-ray monochromator which should be practically aberration-free. The focusing properties of such kind of monochromator are discussed in detail and it is shown for the first time that it can be used not only for focusing but also for creating highly parallel monochromatic beam in the broad region of the Bragg angles. This device with parabolic hole has not been tested experimentally yet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method to estimate the electron temperature and neutral density in a plasma from spectroscopic measurements using argon atom and ion collisional-radiative models

We present a method to infer the electron temperature in argon plasmas using a collisional-radiative model for argon ions and measurements of electron density to interpret absolutely calibrated spectroscopic measurements of argon ion (Ar II) line intensities. The neutral density, and hence the degree of ionization of this plasma, can then be estimated using argon atom (Ar I) line intensities and a collisional-radiative model for argon atoms. This method has been tested for plasmas generated on two different devices at the University of Texas at Austin: the helicon experiment and the helimak experiment. We present results that show good correlation with other measurements in the plasma.

74 ATOMIC AND MOLECULAR PHYSICS↗

X-ray multilayer characterization using reflectivity beamline at Indus-1

Poor knowledge of optical constants of various materials in the soft x-ray region requires to test the soft x-ray optical devices at actual wavelengths. For such purposes a soft x-ray/vacuum ultraviolet reflectivity beamline has been setup on Indus-1 synchrotron.X-ray multilayer structures are also being developed at RRCAT. Silicon based different multilayer optics fabricated in house for 100-200A ring wavelength region show a very high reflectivity performance. A new multilayer combination comprised of NbC/Si is proposed for achieving good thermal stability high reflectivity in the Si L-edge region. A high reflectivity of 63% in near normal incidence region is obtained with a sputter deposited Mo/Si combination. Results prospects of growing NbC/Si multilayer are presented.

43 PARTICLE ACCELERATORS↗

Development of versatile multiaperture negative ion sources

Enhancement of negative ion sources for production of large ion beams is a very active research field nowadays, driven from demand of plasma heating in nuclear fusion devices and accelerator applications. As a versatile test bench, the ion source NIO1 (Negative Ion Optimization 1) is being commissioned by Consorzio RFX and INFN. The nominal beam current of 135 mA at −60 kV is divided into 9 beamlets, with multiaperture extraction electrodes. The plasma is sustained by a 2 MHz radiofrequency power supply, with a standard matching box. A High Voltage Deck (HVD) placed inside the lead shielding surrounding NIO1 contains the radiofrequency generator, the gas control, electronics and power supplies for the ion source. An autonomous closed circuit water cooling system was installed for the whole system, with a branch towards the HVD, using carefully optimized helical tubing. Insulation transformer is installed in a nearby box. Tests of several magnetic configurations can be performed. Status of experiments, measured spectra and plasma luminosity are described. Upgrades of magnetic filter, beam calorimeter and extraction grid and related theoretical issues are reviewed.

43 PARTICLE ACCELERATORS↗

Low-temperature capacitive sensor based on perovskite oxides

Energy, environmental and social issues drive towards the green political economy and the development of advanced technologies, promoting renewable energy sources, improving energy conversion efficiency and reducing exhaust gas emissions. The development of sustainable technologies requires strategic research in the area of gas sensors for monitoring air quality, controlling gas emissions and optimizing combustion processes. Solid state sensors are the most attractive one because of their simplicity in function, small size and low cost. The aim of this work is to synthetize and characterize strontium titanate and test its sensing performance. The prepared sensor device shows significant sensitivity and response rate at room-temperature. However, because of the low recovery rate, the regeneration of the sensor has to be made at high temperature for promoting the decomposition of the carbonates formed on the perovkite surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bulk ion heating with ICRF waves in tokamaks

Heating with ICRF waves is a well-established method on present-day tokamaks and one of the heating systems foreseen for ITER. However, further work is still needed to test and optimize its performance in fusion devices with metallic high-Z plasma facing components (PFCs) in preparation of ITER and DEMO operation. This is of particular importance for the bulk ion heating capabilities of ICRF waves. Efficient bulk ion heating with the standard ITER ICRF scheme, i.e. the second harmonic heating of tritium with or without {sup 3}He minority, was demonstrated in experiments carried out in deuterium-tritium plasmas on JET and TFTR and is confirmed by ICRF modelling. This paper focuses on recent experiments with {sup 3}He minority heating for bulk ion heating on the ASDEX Upgrade (AUG) tokamak with ITER-relevant all-tungsten PFCs. An increase of 80% in the central ion temperature T{sub i} from 3 to 5.5 keV was achieved when 3 MW of ICRF power tuned to the central {sup 3}He ion cyclotron resonance was added to 4.5 MW of deuterium NBI. The radial gradient of the T{sub i} profile reached locally values up to about 50 keV/m and the normalized logarithmic ion temperature gradients R/LT{sub i} of about 20, which are unusually large for AUG plasmas. The large changes in the T{sub i} profiles were accompanied by significant changes in measured plasma toroidal rotation, plasma impurity profiles and MHD activity, which indicate concomitant changes in plasma properties with the application of ICRF waves. When the {sup 3}He concentration was increased above the optimum range for bulk ion heating, a weaker peaking of the ion temperature profile was observed, in line with theoretical expectations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Topological transformations of Hopf solitons in chiral ferromagnets and liquid crystals

Significance While arising in theories in many branches of science, from particle physics to condensed matter and cosmology, stable three-dimensional topological solitons remained experimentally elusive until very recently. We now show that such solitons can be electrically and magnetically switched between states with the same or different Hopf indices. Richness and robustness of this switching promise technological applications in the new breeds of information displays and data storage devices, as well as may provide a test ground and new inspirations for the mathematical knot theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and Performance of Superconducting Undulators at the Advanced Photon Source

Several years ago, an article in SRN [1] with the same title as this article summarized the decade-long development of superconducting undulators (SCUs) at the Advanced Photon Source (APS). The article presented those developments leading to the point when the first prototype, called SCU0 and intended for installation at the APS, was under fabrication. SCU0 was built in 2012, its cryogenic performance has been extensively tested, and detailed magnet measurements of the device have been conducted. After verification that SCU0 met all of the technical requirements for APS insertion devices, it was installed in the APS storage ring in January 2013, commissioned in a record short time (two weeks), and became a routinely used source of hard X-rays at the APS Sector 6 ID beamline.

Gluskin, Efim↗

Ion Fluxes and Neutral Gas Ionization Efficiency of the 100-kW Light-Ion Helicon Plasma Source Concept for the Material Plasma Exposure eXperiment

Linear plasma devices are cost-effective alternatives for testing materials under reactor-relevant divertor plasma conditions. In this work, we describe how an intense radio-frequency (RF) plasma source concept for the Material Plasma Exposure eXperiment (MPEX) is under development at Oak Ridge National Laboratory. The source concept, Proto-MPEX, aims to produce high-density background deuterium helicon plasmas ( n e > 3 × 10 19 m - 3 ) that are subsequently heated with additional RF and microwave systems to deliver reactor-relevant conditions for studies on plasma-material interaction. In this work, we focus on the plasma-producing stage and its effectiveness in converting input neutral gas into plasma, namely, the neutral gas ionization efficiency. We provide a direct quantitative measurement of the ionization efficiency by measuring the total ion flux arriving at the target region relative to the neutral gas injected at the source. Using 80 kW at 13.56 MHz and a source magnetic field of 0.05 T, the helicon plasma source delivers ion fluxes up to 1 × 10 24 m - 2 s - 1 and heat fluxes greater than 1 M W m - 2 to a target plate located 2 m away from the source. Under these conditions, we observe that the plasma source converts ~89% of the input neutral gas into plasma that arrives at the target as ion flux at a rate of 5 × 10 20 s - 1 . We demonstrate that because of the large pumping capacity of the plasma, neutral gas pumping systems are required only in the target region to maintain optimal plasma operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel High-Power Microwave Circulator Employing Circularly Polarized Waves

A novel four-port circulator is presented which uses an inline ferromagnetic element to allow for transmission or reflection depending on the sense of the incident circularly polarized wave. This configuration has been shown to reduce the dependency on ferrite anisotropy and support higher power, low rf loss, operation. An analytic analysis of this device is presented here alongside corroborating cold test data of the first prototype. High-power operation was performed at 2.856 GHz, with input power levels up to 8 MW for 3.5 μs in a pressurized nitrogen environment. The results from this research not only demonstrate ability to eliminate the use of greenhouse insulators, such as SF6, but also provide conceptual groundwork for a new class of ultrahigh power (50 MW+) nonreciprocal networks including circulators, isolators, phase shifters, and rf switches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physical vapor deposition simulator by graphical processor unit ray casting

This paper presents fast, accurate software for modeling physical vapor deposition systems over irregular surfaces. The model is implemented using graphics processing unit (GPU) ray casting. Applied models are viewed as a cross section of the area of interest. Given evaporation rate, time, and angular profiles in a vacuum system, an iterative time-step approach for calculating deposition profiles is calculated in the GPU architecture following a ballistic modeling approach. Thin-film technologies for the electronics industry will require evaporations on complex surfaces. Depending on the nature of the surface, a uniform thin film across the topology is wanted for various device parameters. The ray casting method is tested against various profiles. The code is freely distributed on GitHub (see https://github.com/adam-r-thomas/PVDS).

Engineering↗

EPID-based verification of the MLC performance for dynamic IMRT and VMAT

Purpose: In advanced radiotherapy treatments such as intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT), verification of the performance of the multileaf collimator (MLC) is an essential part of the linac QA program. The purpose of this study is to use the existing measurement methods for geometric QA of the MLCs and extend them to more comprehensive evaluation techniques, and to develop dedicated robust algorithms to quantitatively investigate the MLC performance in a fast, accurate, and efficient manner. Methods: The behavior of leaves was investigated in the step-and-shoot mode by the analysis of integrated electronic portal imaging device (EPID) images acquired during picket fence tests at fixed gantry angles and arc delivery. The MLC was also studied in dynamic mode by the analysis of cine EPID images of a sliding gap pattern delivered in a variety of conditions including different leaf speeds, deliveries at fixed gantry angles or in arc mode, and changing the direction of leaf motion. The accuracy of the method was tested by detection of the intentionally inserted errors in the delivery patterns. Results: The algorithm developed for the picket fence analysis was able to find each individual leaf position, gap width, and leaf bank skewness in addition to the deviations from expected leaf positions with respect to the beam central axis with sub-pixel accuracy. For the three tested linacs over a period of 5 months, the maximum change in the gap width was 0.5 mm, the maximum deviation from the expected leaf positions was 0.1 mm and the MLC skewness was up to 0.2 Degree-Sign . The algorithm developed for the sliding gap analysis could determine the velocity and acceleration/deceleration of each individual leaf as well as the gap width. There was a slight decrease in the accuracy of leaf performance with increasing leaf speeds. The analysis results were presented through several graphs. The accuracy of the method was assessed as 0.01 mm for both the gap size and peak position determination. Conclusions: This study provides fast, easy, and accurate test methods for routine QA of the MLC performance and helps in faster troubleshooting of MLC problems in both IMRT and VMAT treatments.

60 APPLIED LIFE SCIENCES↗

SU-E-J-138: An IGRT QA Device for Measuring with Tenths-Millimeter Accuracy KV and MV Isocenter Congruence, Couch Travel and Laser Alignment of Accelerators Used for SRS and SBRT

Purpose: To develop a practical device having sufficient accuracy for daily QA tests of accelerators used for SRS and SBRT. Methods: The UAB (Universal Alignment Ball) consists of a 6.35 mm (1/4 inch) diameter tungsten sphere located concentrically within a 25.4 mm (1 inch) diameter acrylic plastic (PMMA) sphere. The spheres are embedded in polystyrene foam, which, in turn, is surrounded by a cylindrical PMMA shell. The UAB is placed on the couch and aligned with wall lasers according to marks that have known positions in relation to the center of the spheres. Using planar and cone beam images the couch is shifted till the surface of the PMMA sphere matches Eclipse-generated circular contours. Anterior and lateral MV images taken with small MLC openings allow measurement of distance between kV and MV isocenter, laser and MLC alignment. Measurements were taken over a one-month period. Results: Artifacts from the tungsten sphere were confined within the PMMA sphere and did not affect cone beam localization of the sphere boundary, allowing 0.1 mm precise alignment with a computer-generated circle centered at kV isocenter. In tests extending over a one-month period, the distance between kV and MV isocenters along the vertical, longitudinal and lateral directions was 0.125 +/−0.06, 0.19 +/−0.08, and 0.02 +/−0.08 mm, respectively. Laser misalignment along these directions was 0.34 +/- 0.15, 0.74 +/−0.29, and 0.49 +/−0.22 mm. Automated couch shifts moved the spheres to within 0.1 mm of the selected position. The center of a 1cmx1cm MLC-defined field remained within +/−0.2 mm of the tungsten sphere center as the gantry was rotated. Conclusion: The UAB is practical for daily end-to-end QA tests of accelerator alignment. It provides tenths-mm accuracy for measuring agreement of kV and MV isocenters, couch motions, gantry flex and laser alignment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mixed-Potential NO x and NH 3 Sensors Fabricated by Commercial Manufacturing Methods [Mixed-Potential Sensors NO x and NH 3 Fabricated by Commercial Manufacturing Methods]

Meeting EPA Tier 3 emissions reduction requirements while simultaneously increasing fuel economy to meet new CAFE standards will require optimization of advanced combustion strategies and emissions control technologies. There is an immediate need for suitable exhaust gas sensor technologies to monitor internal combustion engine tailpipe emissions and to control and maintain efficient operation of the engine and exhaust after treatment systems. NH 3 , NO x , and HC sensors could enable onboard diagnostics and combustion control in lean-burn engines, analogous to the role of O 2 sensors in stoichiometric burn engines. Commercial manufacturing methods have been used to fabricate self-heated mixed-potential sensors in a planar automotive configuration. By altering materials composition and operating conditions, we are able to obtain sensitivity/selectivity to each NH 3 , NO x and HCs. In addition, these devices exhibit stable performance over months of testing as a result of the stable morphology of the electrode/electrolyte/gas three-phase interface.

36 MATERIALS SCIENCE↗

Secondary Pore Network Design Optimization Analytical Diffusion Model for Lithium Ion Battery

Fast ion transport along the electrode thickness is required for Lithium ion battery (LIB) to sustain continuous high-rate discharge or charge currents, which is a desired feature for the fast charging of electric vehicle batteries. Advance in LIB electrode manufacturing allows to control, to a certain extent, the electrode microstructure architecture in order to improve the macroscopic performances of these devices. For instance, several groups have experimentally tested architectures tailored specifically to increase the through plane ionic diffusion in regards for fast charge application by adding channels or groove-like large pores oriented along the electrode thickness. These voids do not replace the existing pores of the electrode microstructure but consist in a second, coarser, pore network, called the secondary pore network (SPN). The model quantifies the impact of SPN on ionic diffusion with a composite electrode through a simple analytical approach, considering various pore channel geometries and comparing to standard electrodes with identical gravimetric and identical volumetric specific theoretical capacity. The goal is to find optimal SPN design parameters according to three optimization objectives aiming to balance the improved overall through-plane, thanks to the coarse aligned channels, and the degraded in-plane diffusion, due to the porous matrix densification required to maintain gravimetric and volumetric specific theoretical capacity. The analytical model must be considered as a pre-screening tool to quickly investigate large design space, that can be refined later with more complex electrochemical CPU-expensive numerical models.

Usseglio Viretta, Francois↗

Coupled Thermal-Hydraulic and Fuel Performance Simulations of the TWIST LOCA Commissioning Test Series in TREAT

As the nuclear industry is looking to increase light water reactor (LWR) burnup limits, Idaho National Laboratory has developed an experiment vehicle for the Transient Reactor Test Facility (TREAT) to support high burnup fuel safety testing. One of the main purposes of this vehicle, known as the Transient Water Irradiation System for TREAT (TWIST), is to perform in-pile loss-of-coolant accident (LOCA) experiments on high burnup LWR fuel to investigate phenomena termed fuel fragmentation, relocation, and dispersal (FFRD). Prior to performing experiments on high burnup fuel specimens, a commissioning test series will be performed. The main purpose of the Loss-of-Coolant-Commissioning (LOC-C) test series is to qualify the TWIST device and validate the power coupling between TREAT and the TWIST fuel rod as well as validation of the thermal-hydraulic and fuel performance simulation predictions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Non-destructive Magnetic Momentum Monitor Using a TE011 Cavity

The Jefferson Lab Electron-Ion Collider (JLEIC) design relies on cooling of the ion beam with bunched electron beam. The bunched beam cooler complex consists of a high current magnetized electron source, an energy recovery linac, a circulating ring, and a pair of long solenoids where the cooling takes place. A non-invasive real time monitoring system is highly desired to quantify electron beam magnetization. The authors propose to use a passive copper RF cavity in TE011 mode as such a monitor. In this paper, we will show the mechanism and scaling law of this device, as well as the design and testing results of the prototype cavity.

Guo, Jiquan↗

Photovoltaic Shading Testbed for Module-Level Power Electronics

This document describes a repeatable test procedure that attempts to simulate shading situations, as would be experienced by typical residential rooftop photovoltaic (PV) systems. This type of shading test is particularly useful to evaluate the impact of different power conversion setups, including microinverters, DC power optimizers and string inverters, on overall system performance. Theperformance results are weighted based on annual estimates of shade to predict annual performance improvement. A trial run of the test procedure was conducted with a side by side comparison of a string inverter with a microinverter, both operating on identical 8kW solar arrays. Considering three different shade weighting conditions, the microinverter was found to increase production by 3.7%under light shading, 7.8% under moderate shading, and 12.3% under heavy shading, relative to the reference string inverter case. Detail is provided in this document to allow duplication of the test method at different test installations and for different power electronics devices.

14 SOLAR ENERGY↗