Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnostics engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Develop Prototype Microwave Interferometry Diagnostic

A prototype microwave interferometer was created at NSTec to characterize moving conductive fronts in upcoming experiments. The interferometer is capable of operation in the ~26-40 GHz band, and interrogating fronts with more than 1 W of power.

42 ENGINEERING↗

Development of a preliminary design of a method to measure the effectiveness of virus exclusion during water process reclamation at zero-G

Organon Diagnostics has developed, under NASA sponsorship, a monitoring system to test the capability of a water recovery system to reject the passage of viruses into the recovered water. In this system, a non-pathogenic marker virus, bacteriophage F2, is fed into the process stream before the recovery unit and the reclaimed water is assayed for its presence. An engineering preliminary design has been performed as a parallel effort to the laboratory development of the marker virus test system. Engineering schematics and drawings present a preliminary instrument design of a fully functional laboratory prototype capable of zero-G operation.

Fraser, A. S.↗

“Metallic burn paper” used for in situ characterization of laser beam properties

In situ ablation of thin metal films on fused silica substrates by picosecond class lasers was investigated in this paper as a method of characterizing the beam at the sample plane. The technique involved plotting the areas enclosed by constant fluence contours identified in optical microscope images of the ablation sites versus the logs of the pulse energies. Inconel films on commercially available neutral density filters as well as magnetron sputtered gold films were used. It was also shown that this technique could be used to calibrate real-time beam profile diagnostics against the beam at the sample plane. Finally, the contours were shown to correspond to the boundary where part or all of the film was ablated.

42 ENGINEERING↗

Electron Generation and Transport in Intense Relativistic Laser-Plasma Interactions Relevant to Fast Ignition ICF

The reentrant cone approach to Fast Ignition, an advanced Inertial Confinement Fusion scheme, remains one of the most attractive because of the potential to efficiently collect and guide the laser light into the cone tip and direct energetic electrons into the high density core of the fuel. However, in the presence of a preformed plasma, the laser energy is largely absorbed before it can reach the cone tip. Full scale fast ignition laser systems are envisioned to have prepulses ranging between 100 mJ to 1 J. A few of the imperative issues facing fast ignition, then, are the conversion efficiency with which the laser light is converted to hot electrons, the subsequent transport characteristics of those electrons, and requirements for maximum allowable prepulse this may put on the laser system. This dissertation examines the laser-to-fast electron conversion efficiency scaling with prepulse for cone-guided fast ignition. Work in developing an extreme ultraviolet imager diagnostic for the temperature measurements of electron-heated targets, as well as the validation of the use of a thin wire for simultaneous determination of electron number density and electron temperature will be discussed.

42 ENGINEERING↗

Time Delay from Corona to Breakdown

This report describes measurements of the time delay between the onset of corona and complete electrical breakdown between a point and a plane in dry air near atmospheric pressure as a function of the distance between the point and the plane. The large variation in these time delays is representative of the stochastic nature of electrical breakdown and the many possible phenomena that occur between the initiation and completion of electrical breakdown, including initiation without complete electrical breakdown. The purpose of this work is to provide data which will be accurately modeled when a model contains the appropriate mechanisms with the proper priorities to describe this fundamental electrical breakdown configuration. The acquisition of these measurements completes a level three milestone for the WSEAT program which sponsors this research. Also included in this report is a description of our plans to “automate” the experimental procedure, protect the high sensitivity fast-gated camera, and add diagnostics and new experimental techniques to the test facility. This will provide measurements of the time delay distributions with improved statistics and additional experimental information about the processes that occur during electrical breakdown.

42 ENGINEERING↗

Robotic Subsurface Analyzer and Sample Handler for Resource Reconnaissance and Preliminary Site Assessment for ISRU Activities at the Lunar Cold Traps

Since the 1960s, claims have been made that water ice deposits should exist in permanently shadowed craters near both lunar poles. Recent interpretations of data from the Lunar Prospector-Neutron Spectrometer (LP- NS) confirm that significant concentrations of hydrogen exist, probably in the form of water ice, in the permanently shadowed polar cold traps. Yet, due to the large spatial resolution (45-60 Ian) of the LP-NS measurements relative to these shadowed craters (approx.5-25 km), these data offer little certainty regarding the precise location, form or distribution of these deposits. Even less is known about how such deposits of water ice might effect lunar regolith physical properties relevant to mining, excavation, water extraction and construction. These uncertainties will need to be addressed in order to validate fundamental lunar In Situ Resource Utilization (ISRU) precepts by 2011. Given the importance of the in situ utilization of water and other resources to the future of space exploration a need arises for the advanced deployment of a robotic and reconfigurable system for physical properties and resource reconnaissance. Based on a collection of high-TRL. designs, the Subsurface Analyzer and Sample Handler (SASH) addresses these needs, particularly determining the location and form of water ice and the physical properties of regolith. SASH would be capable of: (1) subsurface access via drilling, on the order of 3-10 meters into both competent targets (ice, rock) and regolith, (2) down-hole analysis through drill string embedded instrumentation and sensors (Neutron Spectrometer and Microscopic Imager), enabling water ice identification and physical properties measurements; (3) core and unconsolidated sample acquisition from rock and regolith; (4) sample handling and processing, with minimized contamination, sample containerization and delivery to a modular instrument payload. This system would be designed with three mission enabling goals, including: (1) a self-contained, low power, low mass, "black box'' configuration for operations from a lander, various classes of rovers or a surface-based platform with human assistance or robotic anchoring mechanisms; (2) reconfigurable and scalable sample handling for delivery to various types of instrumentation, depending on mission requirements; and (3) the use of advanced automation control and diagnostic techniques that will afford local human deployed, remote teleoperation and fully autonomous intelligent operations. Though a great deal of technology has been advanced toward these objectives, the SASH system faces significant design challenges, including the low gravity environment, various levels of autonomy in operations, radiation exposure, dust contamination, and temperature extremes and deltas. Significant input from the scientific and engineering communities, as well as a significant environmental testing program, will be required to guide the design process.

Gorevan, S. P.↗

Implications of real-gas behavior on refractive index calculations for optical diagnostics of fuel–air mixing at high pressures

Three models to compute the refractive index of gaseous mixtures at real gas conditions are presented with the purpose to improve the accuracy of state relationships between refractive index and thermodynamic properties. Models are compared with experimental data to determine one that is applicable to high pressure mixtures with non-ideal thermodynamic behavior near or above a fluids’ critical point. The optimal model is applied to analyze adiabatic thermal mixing of fuel and air at typical diesel engine conditions. Our results show that the ideal gas mixture law is appropriate in the vapor region, assuming it is known, for example, from experimental measurements. Finally, the model is applied for binary fuel-air mixing at supercritical conditions to demonstrate its full potential.

02 PETROLEUM↗

Rocket engine control and monitoring expert system

This paper focuses on the application of expert systems technology to the automatic detection, verification and correction of anomalous rocket engine operations through interfacing with an intelligent adaptive control system. The design of a reliable and intelligent propulsion control and monitoring system is outlined which includes the architecture of an Integrated Expert System (IES) serving as the core component. The IES functions include automatic knowledge acquisition, integrated knowledge base, and fault diagnosis and prediction methodology. The results of fault analysis and diagnostic techniques are presented for an example fault in the SSME main combustion chamber injectors.

Ali, Moonis↗

Integrated System Health Management (ISHM) Implementation in Rocket Engine Testing

A pilot operational ISHM capability has been implemented for the E-2 Rocket Engine Test Stand (RETS) and a Chemical Steam Generator (CSG) test article at NASA Stennis Space Center. The implementation currently includes an ISHM computer and a large display in the control room. The paper will address the overall approach, tools, and requirements. It will also address the infrastructure and architecture. Specific anomaly detection algorithms will be discussed regarding leak detection and diagnostics, valve validation, and sensor validation. It will also describe development and use of a Health Assessment Database System (HADS) as a repository for measurements, health, configuration, and knowledge related to a system with ISHM capability. It will conclude with a discussion of user interfaces, and a description of the operation of the ISHM system prior, during, and after testing.

Figueroa, Fernando↗

Can We Practically Bring Physics-based Modeling Into Operational Analytics Tools?

We present that analytics software is increasingly used to improve and maintain operational efficiency in commercial buildings. Energy managers, owners, and operators are using a diversity of commercial offerings often referred to as Energy Information Systems, Fault Detection and Diagnostic (FDD) systems, or more broadly Energy Management and Information Systems, to cost-effectively enable savings on the order of ten to twenty percent. Most of these systems use data from meters and sensors, with rule-based and/or data-driven models to characterize system and building behavior. In contrast, physics-based modeling uses first-principles and engineering models (e.g., efficiency curves) to characterize system and building behavior. Historically, these physics-based approaches have been used in the design phase of the building life cycle or in retrofit analyses. Researchers have begun exploring the benefits of integrating physics-based models with operational data analytics tools, bridging the gap between design and operations. In this paper, we detail the development and operator use of a software tool that uses hybrid data-driven and physics-based approaches to cooling plant FDD and optimization. Specifically, we describe the system architecture, models, and FDD and optimization algorithms; advantages and disadvantages with respect to purely data-driven approaches; and practical implications for scaling and replicating these techniques. Finally, we conclude with an evaluation of the future potential for such tools and future research opportunities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Radio frequency emission from high-pressure xenon arcs: A systematic experimental analysis of the underlying near-anode plasma instability

High-pressure Xe discharge lamps at DC operation can show unwanted strong RF (radio-frequency) emission to beyond 1 GHz, correlated to a sharp periodic lamp-voltage instability in the near-anode plasma with a pulse repetition rate {epsilon} of 1-10 MHz. The physical origin of the instability is unclear. Here, its existence and pulse rate have been measured as a function of arc current I = 0.2-1.2 A and anode temperature T{sub a} = 1700-3400 K independently, in experimental lamps with pure-tungsten electrodes and a Xe operating pressure around p = 10 MPa. Surprisingly, the instability is not affected by I or current density j but exists if T{sub a} is lower than a threshold value around 2800-2900 K. The pulse rate {epsilon} is simply a rising linear function of the inverse anode temperature 1/T{sub a}, with only a small I-dependent correction. The average anode heat load is slightly lower in the unstable regime and possibly depends on {epsilon}. The results allow a consistent re-interpretation of earlier and present experimental observations and should be both a valuable help in practical lamp engineering and a tight constraint for future theories of this effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Production Facility System Reliability Analysis Report

This document describes the reliability, maintainability, and availability (RMA) modeling of the Los Alamos National Laboratory (LANL) design for the Closed Loop Helium Cooling System (CLHCS) planned for the NorthStar accelerator-based 99 Mo production facility. The current analysis incorporates a conceptual helium recovery system, beam diagnostics, and prototype control system into the reliability analysis. The results from the 1000 hr blower test are addressed.

Accelerator Design, Technology, and Operations↗

Electron beam diagnostic system using computed tomography and an annular sensor

A system for analyzing an electron beam including a circular electron beam diagnostic sensor adapted to receive the electron beam, the circular electron beam diagnostic sensor having a central axis; an annular sensor structure operatively connected to the circular electron beam diagnostic sensor, wherein the sensor structure receives the electron beam; a system for sweeping the electron beam radially outward from the central axis of the circular electron beam diagnostic sensor to the annular sensor structure wherein the electron beam is intercepted by the annular sensor structure; and a device for measuring the electron beam that is intercepted by the annular sensor structure.

42 ENGINEERING↗

Hybrid Model-Based and Data-Driven Fault Detection and Diagnostics for Commercial Buildings

Commercial buildings often experience faults that produce undesirable behavior in building systems. Building faults waste energy, decrease occupants' comfort, and increase operating costs. Automated fault detection and diagnosis (FDD) tools for buildings help building owners discover and identify the root causes of faults in building systems, equipment, and controls. Proper implementation of FDD has the potential to simultaneously improve comfort, reduce energy use, and narrow the gap between actual and optimal building performance. However, conventional rule-based FDD requires expensive instrumentation and valuable engineering labor, which limit deployment opportunities. This paper presents a hybrid, automated FDD approach that combines building energy models and statistical learning tools to detect and diagnose faults noninvasively, using minimal sensors, with little customization. We compare and contrast the performance of several hybrid FDD algorithms for a small security building. Our results indicate that the algorithms can detect and diagnose several common faults, but more work is required to reduce false positive rates and improve diagnosis accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IDAES-PSE 2.3.0 Release

The Institute for the Design of Advanced Energy Systems (IDAES) Integrated Platform is a versatile computational environment offering extensive process systems engineering (PSE) capabilities for optimizing the design and operation of complex, interacting technologies and systems. IDAES enables users to efficiently search vast, complex design spaces to discover the lowest cost, most environmentally sustainable solutions while supporting the full process modeling lifecycle, from conceptual design to dynamic optimization and control. The extensible, open platform empowers users to create models of novel processes and rapidly develop custom analyses, workflows, and end-user applications.. New Features and Models • New diagnostics toolboxes and examples o Tutorial for using the DiagnosticsToolbox o Methods to identify potential evaluation errors in models o SVDToolbox for performing singular value decomposition analysis on models to identify possible degeneracies and poor scaling o DegeneracyHunter for identifying irreducible degenerate sets in models • Model for solid-liquid separation which takes two inputs (solid and liquid streams) and produces three outlets (solids, liquid entrained with solids and pure liquid) • Example of temperature swing adsorption in models_extra Deprecation Warnings • With the update to Pyomo 6.7.0, the plate heat exchanger model has begun failing tests on some CI platforms. If this is not addressed by the February release, this model may be removed due to failing tests. See #1294. Offers to help identify the cause and fix this issue are welcome. Improvements and bug fixes • Fixed oversight which precluded using Mixer and Separator models when inherent reactions were present in property package • Added reporting methods to the MSContactor model • Minor corrections in some examples where values were being fixed outside of declared variable bounds

DiagnosticsToolbox,IDAES,PSE,Process Systems Engin↗