On The Management Of Radiographic Noise Sources

The numerous types of noise in a typical radiograph include: quantum noise, read noise, thermal noise, scatter, etc. The character of these noise sources can be non-stationary, non-linear, Gaussian, Poisson, white, pink, additive, multiplicative, point, random and/or systematic. Furthermore these noise sources impact radiographic factors including: conjugates, exposure duration, filtration, detector type, Swank & Fano factors, Bucky grids, energy, collection optics, charge leakage, digitizer type, dynamic range, detector temperature, pixel size, calibration technique, system stability etc. In short, the “noise” in a radiograph is a very complex subject with many real-world tradeoffs. We delineate the noise sources in a typical silicon detector (e.g. CCD, CMOS, or AmSi, TFT) to illustrate the character of those sources and statistics behind some of the choices required to readout and calibrate those detectors.

47 OTHER INSTRUMENTATION↗

2018 Nanometrics Centaur Digitizer Evaluation

Sandia National Laboratories has tested and evaluated two Nanometrics Centaur digitizers. The Centaur digitizers are intended to record sensor output for seismic and infrasound monitoring applications. The purpose of this digitizer evaluation is to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self- noise, dynamic range, system noise, response, passband, and timing. The Centaur digitizers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

UV/Near-IR Aerosol Absorption Monitor

In this DOE SBIR Phase I study, we have designed and constructed two prototypes demonstrating proof of concept for a new aerosol measurement instrument: a UV/near-IR aerosol absorption monitor. One prototype operates at 360nm and the other at 1064nm. From the laboratory testing and evaluation, we obtained the following technical specifications for the two prototypes: (A) Photoacoustic measurements of aerosol light absorption at 360nm and 1064 nm; (B) Detection limit of 1.0 Mm-1 in 10s-averaging and 0.36 Mm-1 in 100s at 1064nm; (C) Detection limit of 9 Mm-1 in 10s at 360nm; (D) Time response of 4.3 ± 0.6 s, using the 90% criteria; (E) Linear dynamic range from 0.36 Mm to 250 Mm-1 at 1064nm; (F) Sample flow rate of 0.5-2.0 liter per minute; (G) Continuous measurement at 1s sampling rate; (H) An aerosol-based calibration approach; (I) Dimension of 56cm×43cm×25cm and 25kg for the near-IR prototype; while 66cm×43cm×38cm and 30kg for the UV prototype. In this Phase I study, we changed the modulation approach applied to the UV prototype to improve its detection sensitivity. Using an optical chopper to chop the laser beam instead of the electronic modulation on its power supply, we were able to increase the effective laser power and thereby improve the sensitivity by a factor of 2.1. However there is a tradeoff of utilizing a chopper. This approach can only produce a single modulation frequency, presenting an obstacle to combining the UV and near-IR aerosol absorption monitors into a single two-wavelength measurement instrument. Given that the near-IR prototype meets all the desired technical specifications from the DoE SBIR program, this instrument will be ready to be commercialized in the Phase II program. On the other hand, in addition to a different modulation scheme from the near-IR model, the UV aerosol absorption monitor needs some improvements to achieve the desired technical objective in measurement sensitivity. Thus the future Phase II program would primarily focus on improving the UV model and developing both the UV and near-IR aerosol absorption monitors into standalone commercial products.

54 ENVIRONMENTAL SCIENCES↗

Detecting Single Electrons in IOTA [Slides]

Detect synchrotron-light signal and characterize backgrounds in IOTA for 1) Beam diagnostics: turn-by-turn intensity monitor with wide dynamic range, from nominal intensities (~10 9 particles) down to single electrons; 2) Scientific experiments in IOTA: what is the time structure of radiation emission from a single electron in a storage ring? Is it random, regular, chaotic? Is there correlation between the emission from different dipoles?

43 PARTICLE ACCELERATORS↗

Toward High-Intensity Ionization Chamber Beam Intensity Monitors in Switchyard

Beam intensity in the Switchyard beamlines is monitored by Secondary Emission Monitors ("SEMs") and Ionization Chambers ("ICs"). While less-expensive and easier to calibrate than SEMs, IC performance has typically degraded at higher beam intensities. This paper describes a proof-of-principle modification to a standard IC and associated electronics to increase the upper dynamic range of the system, showing that it is feasible to use ICs for high-intensity beamlines.

43 PARTICLE ACCELERATORS↗

Understanding the Response of Photosynthetic Metabolism in Tropical Forests to Seasonal Climate Variations

We propose a study focused on the basic question: What controls the response of photosynthesis in Amazonian forests to seasonal variations in climate? This question, despite its apparent simplicity, remains difficult for modern earth system models to answer, and is also the subject of continuing controversy in the remote-sensing literature. For example, in the modeling arena, four cutting-edge earth system models (ESM’s) show significant divergence in their seasonal patterns of photosynthesis from observed whole-system photosynthetic fluxes at two sites in the central Amazon. The overall objective of the project is to guide improvements in earth system models of tropical forest photosynthesis by collecting and integrating a suite of observations to 1) test several hypotheses (three core, conceptual hypotheses for explaining observed photosynthetic seasonality and a methodological hypotheses for scaling from leaves to canopy with hyperspectral cameras), and 2) perform a synthesis activity that applies our empirical work to earth system models of terrestrial carbon cycling. The project will provide an extensive suite of new and unique datasets that enable us to fill, through advanced modeling techniques and analysis, critical knowledge gaps in current understanding of what controls the response of canopy photosynthesis and related functions in Amazonian forests to seasonal variation in climate. Three major types of datasets and data products will be delivered: (1) in situ leaf and tree-scale measurements from intensive ecophysiological and ecohydological field campaigns, (2) time-series observations of leaf-to-crown scale forest reflectance properties and atmospheric radiation from two innovative, ground-based imaging sensors (respectively, the Hyperspectral Vegetation Imaging System and the High Dynamic Range All-Sky Imaging System), and (3) results from state-of-the-art models of 3-dimensional canopy processes for radiative transfer and photosynthesis that integrate and link our observations to tropical forest processes. These data products and the improved knowledge we achieve with them will contribute to testing and improving the treatment of tropical forest processes in ESMs. They will contribute data to and leverage related data from of the GOAmazon campaign, and make significant contributions to support the overall goals of GOAmazon. This work will also help establish a foundation for the Next Generation Ecosystem Experiments (NGEE) in the Tropics.

54 ENVIRONMENTAL SCIENCES↗

Development and refinement of an in situ ‘molecular microscope’ utilizing ultrahigh resolution mass spectrometry

The ability to elucidate complex metabolic behavior of living organisms in situ and with cellular resolution is a bioanalytical grand challenge that is yet to be realized. Mass spectrometry imaging (MSI) using laser ablation electrospray ionization mass spectrometry (LAESI) has recently been demonstrated, and holds promise for direct spatially resolved molecular profiling in a variety of living systems of DOE relevance (e.g., plant leaf, stem, and root tissue). The LAESI MSI approach has revealed cell-to-cell heterogeneity of metabolites within living plant tissue, in a multiplexed fashion and without the need for labeling. Cellular resolution by in situ, ambient pressure MSI methods are far from routine, however, and have inadequate spatial resolution for many biological questions of interest. We propose to develop next-generation LAESI approaches, using advanced fiber optics and transmission-based geometries, in efforts to attain dynamic bioanalysis of living systems at better than 20 µm lateral resolution. In parallel with LAESI innovations, attendant increases in sensitivity and dynamic range of the mass spectrometer system will also be necessary for detection of the limited amount of material being ionized. To respond to this need, a new, high magnetic field (21 Tesla) Fourier Transform Ion Cyclotron Resonance (FTICR) MS at the EMSL/PNNL will be coupled with the newly developed LAESI source. This mass spectrometer, currently being assembled, will be one of only two such systems in the world, and the only one in a DOE laboratory or user facility. Fundamentally, all key figures of merits of FTICR MS performance improve with increased magnetic field strength, providing the ability to achieve unparalleled molecular specificity (near unequivocal molecular constituent identification) at the highest possible mass resolving power and sensitivity. The work proposed here will greatly increase the utility of this FTICR MS instrument, providing unique capabilities to support BER-relevant science. The research plan is comprised of three tasks, two of which are directed by the academic leads (University of Missouri and George Washington University), and one of which will be performed in conjunction with the BER user facility at EMSL/PNNL. In task 1, advancements of the LAESI technology will be achieved, with oversight and leadership of Professor Akos Vertes of George Washington University. In task 2, incorporation of this ion source with EMSL’s new 21T FTICR MS system will be undertaken, supplemented by global omics measurements and calibrated against more conventional MSI platforms also available at EMSL (Drs. Pasa-Tolic, Anderton, and Koppenaal team). In the final task, the resultant innovations and advancements will be tested and validated by addressing important BER relevant science questions on model systems of interest under the direction of Professor Gary Stacey of the University of Missouri. This research follows on key recommendations of the recent BER “Research in Sustainable Bioenergy” report that, for example, stressed that “The design of sustainable biofuel systems requires knowledge about key plant-microbe-environment interactions that provide a range of ecosystem services.” This task will focus on validation of the instrumentation developed through this proposal, advertising this capability to the community through demonstration and, finally, discovering new biology relevant to the BER mission. This final objective will make use of Setaria viridis, a model C4 grass species, as well as switchgrass and sorghum, two promising biofuel crops. Specifically, we will demonstrate applicability to plant-microbe rhizosphere interactions focusing on the biological nitrogen fixation by monitoring metabolic changes in real-time with nutrient, growth condition, and other perturbations.

09 BIOMASS FUELS↗

An Energy Tunable X-ray Delay Device - Phase II

One potential limitation of the LCLS is the maximum frequency—120 Hz— at which the individual pulses are produced. This maximum frequency is dictated by the fundamental design of the original linear accelerator and serves as a limit on the “frames per second” that can be illuminated by the beam. A potential solution for accessing ultrafast dynamics is by temporally splitting the X-ray pulses into two pulses with arbitrary relative intensity and time delay. In this manner, dynamics ranging from the X-ray pulse duration (between one and several hundred femtoseconds) and the maximum relative pulse delay can be explored by evaluating the X-ray response collected as a function of the relative pulse delay.

43 PARTICLE ACCELERATORS↗

Guralp Affinity Evaluation for SNL Infrasound Testbed

Sandia National Laboratories has tested and evaluated a new digitizer, the Affinity, manufactured by Guralp Systems. This digitizer is used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as sensitivity, self-noise, dynamic range, system noise, relative transfer function, analog bandwidth, harmonic distortion, common mode, cross talk, timing tag accuracy and timing drift. The Affinity provides eight, rather the typical six, channels of 24 bit high sample rate digitization. Moreover, it also provides 16 single-ended, 24 bit resolution, low sample rate auxiliary channels. The Affinity digitizer is undergoing these tests prior to installation in the FACT site infrasound test bed.

47 OTHER INSTRUMENTATION↗

Laser-Diagnostic Platform for Multi-Parameter Hypersonics Measurements

We have investigated the utility of femtosecond/picosecond (fs/ps) coherent anti-Stokes Raman scattering(CARS)for simultaneous measurement of temperature, pressure, and velocity in hypersonic flows. Experiments were conducted in underexpanded jets of air and molecular nitrogen to assess CARS diagnostic performance in terms of signal level scaling, measurement precision, and dynamic range. Pure-rotational CARS of the Raman S branch was applied for simultaneous measurement of temperature and pressure. Thermometry was performed by fitting CARS spectra acquired under nearly collision-free conditions by introducing a picosecond CARS probe pulse at zero delay from the femtosecond pump. Pressure could be subsequently obtained by from a second CARS spectral acquisition with a picosecond probe introduced at time delay to sample molecular collisions. CARS velocimetry was attempted by monitoring the Doppler shift of the N 2 vibrational, Q-branch spectrum, with both direct spectral resolution and optical heterodyne detection schemes. Doppler shifts from the sub-I-km/s air jet flow proved too small to measure with this approach, prompting us to turn to femtosecond laser electronic excitation tagging (FLEET) for reliable single-laser-shot velocimetry and CARS temperature/pressure measurement. Scaling of the CARS signal level to very low pressure and temperature conditions expected in the Sandia hypersonic wind tunnel (HWI) was performed. CARS measurements of temperature in HWT appear to be very feasible, while prospects for HWT pressure measurements are reasonable.

47 OTHER INSTRUMENTATION↗

2019 Hyperion 5313A and 5119A Infrasound Sensor Type Approval Evaluation

Sandia National Laboratories has tested and evaluated two variations of a new model of infrasound sensor, the Hyperion 5313A and 5119A. The purpose of this infrasound sensor evaluation is to measure the performance characteristics in such areas as power consumption, sensitivity, full scale, self-noise, dynamic range, response, passband, sensitivity variation due to changes in static pressure and temperature, and sensitivity to vertical acceleration. The Hyperion infrasound sensors are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the Nanometrics Centaur Digitizer

Sandia National Laboratories has tested and evaluated a new digitizer, the Centaur, manufactured by Nanometrics, Inc. This digitizer is used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as power, sensitivity, self-noise, dynamic range, system noise, modified noise power ration, relative transfer function, analog bandwidth, harmonic distortion, common mode, cross talk, timing tag accuracy and timing drift. The Centaur provides six channels of 24 bit digitization, three of which may be transmitted utilizing CD1.1 protocol.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kinemetrics Q330M+ Digitizer Evaluation

Sandia National Laboratories has tested and evaluated a new digitizer, the Q330M+, manufactured by Quanterra, a division of Kinemetrics Inc. This digitizer is used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as sensitivity, input impedance, power consumption, self noise, dynamic range, system noise, relative transfer function, analog bandwidth, modified noise power ratio, harmonic distortion, common mode, cross talk, timing tag accuracy and timing drift. The Q330M+ provides six channels of 24 bit digitization, all of which may be transmitted utilizing CD1.1 protocol, at multiple sample rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Guralp Affinity Digitizer Evaluation

Sandia National Laboratories has tested and evaluated a new digitizer, the Affinity, manufactured by Guralp Systems. This digitizer is used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as sensitivity, power, self-noise, dynamic range, system noise, relative transfer function, modified noise power ratio, analog bandwidth, harmonic distortion, common mode, cross talk, timing tag accuracy and timing drift. The Affinity provides eight, rather the typical six, channels of 24 bit high sample rate digitization, all of which may be transmitted utilizing the CD1.1 protocol, at multiple sample rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonproliferation Legacy Technology and Artifact Collection: NASA Space Shuttle Tiles

The NASA Space Shuttle Tiles were used by Sandia in the process of developing the Laser Dynamic Range Imager (LDRI) in support of NASA's Return to Flight following the 2003 Space Shuttle Columbia disaster. The heat shield tiles, provided to Sandia by NASA, are identical to those that were located on the underbelly of the Space Shuttle Columbia's orbiter. Sandia used the tiles to test the efficacy of the LDRI's imaging capabilities. The LDRI was utilized during every space shuttle mission between 2005 and 2011. The tiles are currently located in Building 891 and need to be moved to free up space for operational use. Given their technical significance, Sandia would like to archive them as historically significant items in long-term storage until such time as they can be appropriately displayed or employed as a demonstration artifact. This document provides basic information about the provenance of this artifact.

42 ENGINEERING↗

Quantitative Determination of Total Cesium in Savannah River Site (SRS) Tank Waste by Inductively Coupled Plasma Emission Spectroscropy

Utilization of the significant and unique wavelength dynamic range (165 to 1100 nm) available on the Leeman Prodigy Inductively Coupled Plasma Emission Spectroscopy (ICP-ES) allows for quantification of cesium using the emission line 894.347 nm without the potential of Barium interference in nuclear waste samples. Samples are added to a Sodium Peroxide Fusion and Lithium Carbonate buffer in 2% nitric acid solution to increase sensitivity of the easily ionizable (<6 eV) cesium for quantitation to 5 pbb. Through direct comparison of analytical data results, the method is proven to be complementary to the Inductively Coupled Plasma Mass Spectrometry (ICP-MS) analysis (LOQ 100 ppt) in support of the Department of Energy’s (DOE) Nuclear Waste Mission.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation the Geotech GS-13BH Borehole Seismic Sensor

Sandia National Laboratories has tested and evaluated the Geotech GS-13BH borehole sensor. The sensor provides a response similar to that of the standard GS-13 short-period seismic sensor intended for pier-installations in a borehole package. The purpose of this seismometer evaluation was to determine a measured sensitivity, amplitude and phase response, self-noise and dynamic range, passband and acceleration response of its calibration coil.

47 OTHER INSTRUMENTATION↗

Next Generation Qualification: Guralp CMG-3V Seismometer Evaluation

Sandia National Laboratories has tested and evaluated three seismometers, the CMG-3V, manufactured by Guralp. These seismometers measure a single axes of broadband ground velocity in a borehole package. The purpose of the seismometer evaluation was to determine a measured sensitivity, response, passband, self-noise, dynamic range, and self-calibration ability. The Guralp CMG-3V seismometers are being evaluated for potential use in U.S. Air Force seismic monitoring systems as part of their Next Generation Qualification effort.

47 OTHER INSTRUMENTATION↗