Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

SU-F-303-10: Impact of Visual Biofeedback On Respiratory Reproducibility in 4DMRI

Purpose: Precise radiation therapy (RT) for abdominal lesions is complicated by respiratory motion and suboptimal soft tissue contrast in 4DCT. 4DMRI offers improved contrast. However, long scan times and irregular breathing patterns can be limiting. To address this, we introduced visual biofeedback (VBF) into 4DMRI. Methods: Eight healthy volunteers were consented to an IRB-approved protocol. Prospective respiratory-triggered, T2-weighted coronal 4DMRIs were acquired on an open 1.0T MR- SIM. VBF was integrated using an MR-compatible interactive breath-hold control system. Subjects visually monitored their breathing patterns to stay within pre-determined tolerances. 4DMRIs were acquired with and without VBF for 2–8 phase acquisitions. Normalized respiratory waveforms were evaluated for scan time, duty cycle (programmed/acquisition time), breathing period, end-inhale (EI) amplitude, and breathing variability (coefficient of variation, EI-COV). B-spline-based deformable image registration propagated contours from end-exhale (EE) to EI phases. Respiration-induced liver motion was calculated via centroid analysis and compared. Results: Incorporating VBF reduced 2-phase acquisition time (4.7±0.6 and 5.6±1.4 minutes with and without VBF, respectively) while reducing the amplitude EI-COV by 53.0±8.1%. On average, incorporating VBF reduced 8-phase 4DMRI acquisition times by 1.7±1.2 minutes and EI-COVs by 46.0±15.8%. Using VBF yielded higher duty cycles than free breathing (34.7% versus 28.3%, respectively). 4DMRI acquisition time was reduced for the cohort with VBF despite breathing rate remaining similar (10.5±4.0 with vs. 10.6±3.3 BPM without). Respiratory waveforms showed higher EI amplitude with VBF (0.84±0.05 a.u.) as compared to 0.72±0.06 a.u. without. This translated to differences in liver excursions, where superior-inferior, anterior-posterior, and left-right EE-EI displacements were 14.3±3.6, 4.8±2.1, and 1.6±1.0 mm, respectively, with VBF compared to 13.0±6.2, 3.8±2.4, and 1.2±1.4 mm without. Conclusion: Incorporating VBF system into 4DMRI substantially reduced acquisition time and breathing variability. While VBF reduced liver motion variability, differences in excursion were observed, suggesting that implementation will be required throughout the RT workflow. Research supported in part by a grant from Philips HealthCare (Best, Netherlands) and an equipment evaluation agreement with MedSpira.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRA-10: Assessment of Fiber Bragg Grating (FBG)-Based Sensing for Real-Time Needle Tracking During MR-Guided Brachytherapy

Purpose: This study assesses the potential of Fiber Bragg Grating (FBG)-based sensing for real-time needle (including catheter or tube) tracking during MR-guided HDR brachytherapy. Methods: The proposed FBG-based sensing tracking approach involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. When the stylet is inserted inside the lumen of the needle, the FBG sensing system can measure the needle’s deflection. For localization of the needle in physical space, the position and orientation of the stylet base are mandatory. For this purpose, we propose to fix the stylet base and determine its position and orientation using a MR-based calibration as follows. First, the deflection of a needle inserted in a phantom in two different configurations is measured during simultaneous MR-imaging. Then, after segmentation of the needle shapes on the MR-images, the position and orientation of the stylet base is determined using a rigid registration of the needle shapes on both MR and FBG-based measurements. The calibration method was assessed by measuring the deflection of a needle in a prostate phantom in five different configurations using FBG-based sensing during simultaneous MR-imaging. Any two needle shapes were employed for the calibration step and the proposed FGB-tracking approach was subsequently evaluated on the other three needles configurations. The tracking accuracy was evaluated by computing the Euclidian distance between the 3D FBG vs. MR-based measurements. Results: Over all needle shapes tested, the average(standard deviation) Euclidian distance between the FBG and MR-based measurements was 0.79mm(0.37mm). The update rate and latency of the FBG-based measurements were 100ms and 300ms respectively. Conclusion: The proposed FBG-based protocol can measure the needle position with an accuracy, precision, update rate and latency eligible for accurate needle steering during MR-guided HDR brachytherapy. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are fulltime employees of Philips Medical Systems Nederland B.V.

61 RADIATION PROTECTION AND DOSIMETRY↗

Blower-door techniques for measuring interzonal leakage

Abstract The standard blower door test methods, such as ASTM E779, describe how to use a single blower door to determine the total leakage of a single-zone structure such as a detached single-family home. There are no standard test methods for measuring interzonal leakage in a two-zone or multi-zone building envelope such as might be encountered in with an attached garage or in a multifamily building. Some practitioners have been using techniques that involve making multiple measurements with a single blower door as well as combined measurements using multiple blower doors. Even for just two zones there are dozens of combinations of one-door and two-door test protocols that could conceivably be used to determine the interzonal air tightness. We examined many of these two-zone configurations using both simulation and measured data to estimate the accuracy and precision of each technique for realistic measurement scenarios. We also considered the impact of taking measurements at a single pressure versus over multiple pressures. We compared the various techniques and evaluated them for specific uses. Some techniques work better in one leakage regime; some are more sensitive to wind and other noise; some are more suited to determining only a subset of the leakage values. This paper makes recommendations on which techniques to use or not use for various cases and provides data that could be used to develop future test methods.

99 GENERAL AND MISCELLANEOUS↗

SU-E-J-186: Acquiring and Assessing Upright CBCT Images for Future Treatment Planning

Purpose: To acquire upright CBCT images using the onboard imager of a Varian TrueBeam. An easy to implement upright imaging protocol could allow for widespread upright radiation therapy which would greatly benefit certain patients. These include thoracic cancer patients (because lung volume increases in a seated position) and patients who experience substantial discomfort during supine treatment. Methods: To acquire upright CBCT images, the gantry head remained stationary at 0 degrees with the KV imager arms extended to their lateral positions. Phantoms were placed upright at the end of the treatment couch. During a scan, the couch rotated from 270 to 90 degrees while continuous fluoroscopic projections were taken by the onboard imager. To extend the field-of-view, this sequence was performed twice: once with the KV detector longitudinally offset +14.5cm and once with it longitudinally offset −14.5cm. The resulting two image sets were stitched together before reconstruction. The imaging beam parameters were chosen to deliver a dose similar to that given during a simulation CT. Image quality was evaluated for spatial linearity, high and low contrast resolution, and HU linearity using CatPhan and anthropomorphic phantoms. A deformable registration technique was used to evaluate HU mapping from a simulation CT. Results: Spatial linearity and high contrast resolution were maintained in upright CBCT when compared to simulation CT. However, low contrast resolution and HU linearity degraded. Streak artifacts were caused by the limited 180 degree arc of the couch, and the stitching process created a sharp artifact at the center of the reconstruction. The deformable registration was robust in the HU mapping even with these artifacts and the loss of HU linearity. Conclusions: The image quality obtained from upright CBCT was sufficient for treatment planning. The success of this novel technique is an important step towards a future clinical protocol. This project was funded in part by Varian Medical Systems, Inc.

60 APPLIED LIFE SCIENCES↗

Field Evaluations of Low-Frequency SAFT-UT on Cast Stainless Steel and Dissimilar Metal Weld Components

This report documents work performed at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington, and at the Electric Power Research Institute's (EPRI) Nondestructive Examination (NDE) Center in Charlotte, North Carolina, on evalutating a low frequency ultrasonic inspection technique used for examination of cast stainless steel (CSS) and dissimilar metal (DMW) reactor piping components. The technique uses a zone-focused, multi-incident angle, low frequency (250-450 kHz) inspection protocol coupled with the synthetic aperture focusing technique (SAFT). The primary focus of this work is to provide information to the United States Nuclear Regulatory Commission on the utility, effectiveness and reliability of ultrasonic testing (UT) inspection techniques as related to the inservice ultrasonic inspection of coarse grained primary piping components in pressurized water reactors (PWRs).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High Performance Building Facade Solutions - PIER Final Project Report

Building facades directly influence heating and cooling loads and indirectly influence lighting loads when daylighting is considered, and are therefore a major determinant of annual energy use and peak electric demand. Facades also significantly influence occupant comfort and satisfaction, making the design optimization challenge more complex than many other building systems.This work focused on addressing significant near-term opportunities to reduce energy use in California commercial building stock by a) targeting voluntary, design-based opportunities derived from the use of better design guidelines and tools, and b) developing and deploying more efficient glazings, shading systems, daylighting systems, facade systems and integrated controls. This two-year project, supported by the California Energy Commission PIER program and the US Department of Energy, initiated a collaborative effort between The Lawrence Berkeley National Laboratory (LBNL) and major stakeholders in the facades industry to develop, evaluate, and accelerate market deployment of emerging, high-performance, integrated facade solutions. The LBNL Windows Testbed Facility acted as the primary catalyst and mediator on both sides of the building industry supply-user business transaction by a) aiding component suppliers to create and optimize cost effective, integrated systems that work, and b) demonstrating and verifying to the owner, designer, and specifier community that these integrated systems reliably deliver required energy performance. An industry consortium was initiated amongst approximately seventy disparate stakeholders, who unlike the HVAC or lighting industry, has no single representative, multi-disciplinary body or organized means of communicating and collaborating. The consortium provided guidance on the project and more importantly, began to mutually work out and agree on the goals, criteria, and pathways needed to attain the ambitious net zero energy goals defined by California and the US.A collaborative test, monitoring, and reporting protocol was also formulated via the Windows Testbed Facility in collaboration with industry partners, transitioning industry to focus on the importance of expecting measured performance to consistently achieve design performance expectations. The facility enables accurate quantification of energy use, peak demand, and occupant comfort impacts of synergistic facade-lighting-HVAC systems on an apples-to-apples comparative basis and its data can be used to verify results from simulations. Emerging interior and exterior shading technologies were investigated as potential near-term, low-cost solutions with potential broad applicability in both new and retrofit construction. Commercially-available and prototype technologies were developed, tested, and evaluated. Full-scale, monitored field tests were conducted over solstice-to-solstice periods to thoroughly evaluate the technologies, uncover potential risks associated with an unknown, and quantify performance benefits. Exterior shading systems were found to yield net zero energy levels of performance in a sunny climate and significant reductions in summer peak demand. Automated interior shading systems were found to yield significant daylighting and comfort-related benefits.In support of an integrated design process, a PC-based commercial fenestration (COMFEN) software package, based on EnergyPlus, was developed that enables architects and engineers to quickly assess and compare the performance of innovative facade technologies in the early sketch or schematic design phase. This tool is publicly available for free and will continue to improve in terms of features and accuracy. Other work was conducted to develop simulation tools to model the performance of any arbitrary complex fenestration system such as common Venetian blinds, fabric roller shades as well as more exotic innovative facade systems such as optical louver systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Moving into advanced nanomaterials. Toxicity of rutile TiO{sub 2} nanoparticles immobilized in nanokaolin nanocomposites on HepG2 cell line

Immobilization of nanoparticles on inorganic supports has been recently developed, resulting in the creation of nanocomposites. Concerning titanium dioxide nanoparticles (TiO{sub 2} NPs), these have already been developed in conjugation with clays, but so far there are no available toxicological studies on these nanocomposites. The present work intended to evaluate the hepatic toxicity of nanocomposites (C-TiO{sub 2}), constituted by rutile TiO{sub 2} NPs immobilized in nanokaolin (NK) clay, and its individual components. These nanomaterials were analysed by means of FE-SEM and DLS analysis for physicochemical characterization. HepG2 cells were exposed to rutile TiO{sub 2} NPs, NK clay and C-TiO{sub 2} nanocomposite, in the presence and absence of serum for different exposure periods. Possible interferences with the methodological procedures were determined for MTT, neutral red uptake, alamar blue (AB), LDH, and comet assays, for all studied nanomaterials. Results showed that MTT, AB and alkaline comet assay were suitable for toxicity analysis of the present materials after slight modifications to the protocol. Significant decreases in cell viability were observed after exposure to all studied nanomaterials. Furthermore, an increase in HepG2 DNA damage was observed after shorter periods of exposure in the absence of serum proteins and longer periods of exposure in their presence. Although the immobilization of nanoparticles in micron-sized supports could, in theory, decrease the toxicity of single nanoparticles, the selection of a suitable support is essential. The present results suggest that NK clay is not the appropriate substrate to decrease TiO{sub 2} NPs toxicity. Therefore, for future studies, it is critical to select a more appropriate substrate for the immobilization of TiO{sub 2} NPs. - Highlights: • Only the MTT and AB assays were found to be suitable for cytotoxicity assessment. • Alkaline comet assay was also appropriate for genotoxicity evaluation. • All nanomaterials decreased the HepG2 cell viability and caused DNA damage. • Nanokaolin is not a suitable clay substrate for the immobilization of TiO{sub 2} NPs. • Further toxicity studies must be performed in other clays to support nanoparticles.

60 APPLIED LIFE SCIENCES↗

Effective Dose Reduction to Cardiac Structures Using Protons Compared With 3DCRT and IMRT in Mediastinal Hodgkin Lymphoma

Purpose: We investigated the dosimetric impact of proton therapy (PT) on various cardiac subunits in patients with Hodgkin lymphoma (HL). Methods and Materials: From June 2009 through December 2010, 13 patients were enrolled on an institutional review board-approved protocol for consolidative involved-node radiotherapy (INRT) for HL. Three separate treatment plans were developed prospectively by using three-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), and PT. Cardiac subunits were retrospectively contoured on the 11 patients with intravenous-contrast simulation scans, and the doses were calculated for all treatment plans. A Wilcoxon paired test was performed to evaluate the statistical significance (p < 0.05) of 3DCRT and IMRT compared with PT. Results: The mean heart doses were 21 Gy, 12 Gy, and 8 Gy (relative biologic effectiveness [RBE]) with 3DCRT, IMRT, and PT, respectively. Compared with 3DCRT and IMRT, PT reduced the mean doses to the left and right atria; the left and right ventricles; the aortic, mitral, and tricuspid valves; and the left anterior descending, left circumflex, and right circumflex coronary arteries. Conclusions: Compared with 3DCRT and IMRT, PT reduced the radiation doses to all major cardiac subunits. Limiting the doses to these structures should translate into lower rates of cardiac toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final Report - Membranes and MEA's for Dry, Hot Operating Conditions

The focus of this program was to develop a new Proton Exchange Membrane (PEM) which can operate under hotter, dryer conditions than the state of the art membranes today and integrate it into a Membrane Electrode Assembly (MEA). These MEA's should meet the performance and durability requirements outlined in the solicitation, operating under low humidification conditions and at temperatures ranging from -20ºC to 120ºC, to meet 2010 DOE technical targets for membranes. This membrane should operate under low humidification conditions and at temperatures ranging from -20ºC to 120ºC in order to meet DOE HFCIT 2010 commercialization targets for automotive fuel cells. Membranes developed in this program may also have improved durability and performance characteristics making them useful in stationary fuel cell applications. The new membranes, and the MEA's comprising them, should be manufacturable at high volumes and at costs which can meet industry and DOE targets. This work included: A) Studies to better understand factors controlling proton transport within the electrolyte membrane, mechanisms of polymer degradation (in situ and ex situ) and membrane durability in an MEA; B) Development of new polymers with increased proton conductivity over the range of temperatures from -20ºC to 120ºC and at lower levels of humidification and with improved chemical and mechanical stability; C) Development of new membrane additives for increased durability and conductivity under these dry conditions; D) Integration of these new materials into membranes and membranes into MEA's, including catalyst and gas diffusion layer selection and integration; E) Verification that these materials can be made using processes which are scalable to commercial volumes using cost effective methods; F) MEA testing in single cells using realistic automotive testing protocols. This project addresses technical barriers A (Durability) and C (Performance) from the Fuel Cells section of the 2005 Hydrogen, Fuel Cells and Infrastructure Technologies Program Multi-Year R&D Plan. In the course of this four-year program we developed a new PEM with improved proton conductivity, chemical stability and mechanical stability. We incorporated this new membrane into MEAs and evaluated performance and durability.

08 HYDROGEN↗

Hanford double shell waste tank corrosion studies - final report FY2014

SRNL tasks for FY14 included studies to evaluate the susceptibility of carbon steel to vapor space corrosion (VSC), liquid-air interface (LAI) corrosion, and pitting corrosion. Additionally, SRNL evaluated the susceptibility of carbon steel to pitting corrosion under buffered waste conditions, with the objective of determining the adequate amount of inhibitor (e.g., nitrite) necessary to mitigate pitting corrosion. Other CPP experiments were performed in historical waste simulants and the results were compared to previously gathered results. The results of these activities were utilized to assess the robustness of the standardized CPP protocol

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Identification and Evaluation for Fueling of NRIC DOME Reactors Report

The National Reactor Innovation Center (NRIC) has designed a testbed for advanced microreactor experiments that enables and encourages technology developers to bring advanced designs closer to commercial availability. The test bed, Demonstration of Microreactor Experiments (DOME), will be used to facilitate much of the operation experimentation process of the each advanced microreactor including fueling and operational power experiments. This report identifies and evaluates the options for initial fueling the microreactors in DOME. This report also discusses the optional locations that were considered for the initial fueling of microreactor; namely the Transient Reactor Test (TREAT) reactor building, and an unspecified temporary location. But various logistical and construction issues essentially eliminated these other options from further consideration. A brief discussion in this report outlines potential equipment and protocol associated with fueling in DOME.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An exploration of benchtop X–ray emission spectroscopy for precise characterization of the sulfur redox state in cementitious materials

The evolution of sulfur chemistry in cements is best known in the bailiwick of failure mechanisms via sulfate attack but is equally important for its contributions to the reduction capacity of cementitious materials often used for immobilizing nuclear waste streams destined for long-term storage, e.g., cementitious waste forms (CWF). The total reduction capacity of CWFs, encompassing contributions from both S and Fe reductants, and its implications toward radionuclide immobilization is most often studied by destructive wet chemistry methods requiring acid digestion in the presence of Ce(IV) and subsequent titration and colorimetric interpretation. Here, we investigate a similarly analytical but nondestructive alternative, benchtop high resolution wavelength-dispersive x-ray fluorescence spectroscopy, most commonly known as x-ray emission spectroscopy (XES), for probing the bulk sulfur oxidation state distribution. We present here an initial investigation of S XES, including an improved experimental protocol for lab XES of inhomogeneous samples, both as a complement to the Ce(IV) test and for new scientific opportunities that it enables for observing changes in sulfur chemistry. We discuss future improvements and opportunities, including: (1) the practical challenges associated with coordinating XES and Ce(IV) liquid extraction for a more comprehensive perspective on reduction capacity and for a high-precision evaluation of uncertainties in the Ce(IV) test; and (2) new opportunities, due to the nondestructive nature of XES, for controlled evolution studies aimed at elucidating specific chemical responses of CWF’s exposed to invasive gas or liquid species or to accelerated aging by radiative dose or thermal treatment.

36 MATERIALS SCIENCE↗

Part 1: Tracing Russian VX to its synthetic routes by multivariate statistics of chemical attribution signatures

Chemical attribution signatures (CAS) associated with different synthetic routes used for the production of Russian VX (VR) were identified here. The goal of the study was to retrospectively determine the production method employed for an unknown VR sample. Six different production methods were evaluated, carefully chosen to include established synthetic routes used in the past for large scale production of the agent, routes involving general phosphorus-sulfur chemistry pathways leading to the agent, and routes whose main characteristic is their innate simplicity in execution. Two laboratories worked in parallel and synthesized a total of 37 batches of VR via the six synthetic routes following predefined synthesis protocols. The chemical composition of impurities and byproducts in each route was analyzed by GC/MS-EI and 49 potential CAS were recognized as important markers in distinguishing these routes using Principal Component Analysis (PCA). The 49 potential CAS included expected species based on knowledge of reaction conditions and pathways but also several novel compounds that were fully identified and characterized by a combined analysis that included MS-CI, MS-EI and HR-MS. The CAS profiles of the calibration set were then analyzed using partial least squares discriminant analysis (PLS-DA) and a cross validated model was constructed. The model allowed the correct classification of an external test set without any misclassifications, demonstrating the utility of this methodology for attributing VR samples to a particular production method. This work is part one of a three-part series in this Forensic VSI issue of a Sweden-United States collaborative effort towards the understanding of the CAS of VR in diverse batches and matrices. This part focuses on the CAS in synthesized batches of crude VR and in the following two parts of the series the influence of food matrices on the CAS profiles are investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

From lab to lamp: Understanding downconverter degradation in LED packages

Downconverters, primarily inorganic phosphors, are critical components in white solid-state LED-based lighting and liquid crystal display backlights. Research efforts have led to a fundamental understanding of a downconverter's absorption, photoluminescence, and efficiency as a function of composition, structure, and processing conditions. However, considerably less work has focused on the reliability of phosphors once they are incorporated into LED packages. Solving these issues is often the final step before the commercialization of new materials, but the significant resources and time required to evaluate and mitigate materials failure are rarely discussed in the literature. In this Perspective, we discuss the need for conducting downconverter reliability testing and the potential of accelerating, screening, and understanding downconverter failure modes. Our focus highlights the mechanisms of failure and discusses how this influences materials selection and the design of different LED packages. We also stress the potential for accelerated reliability testing protocols and note the potential role first-principles calculations and data-driven models could play in establishing the compositional-processing trends for different aspects of downconverter reliability. In conclusion, we close with possible research directions that could improve downconverter reliability and emphasize the importance of assessing a material's (chemical) stability where multiple manufacturing and processing steps can dictate system performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Objective index of image fidelity for JPEG2000 compressed body CT images

Compression ratio (CR) has been the de facto standard index of compression level for medical images. The aim of the study is to evaluate the CR, peak signal-to-noise ratio (PSNR), and a perceptual quality metric (high-dynamic range visual difference predictor HDR-VDP) as objective indices of image fidelity for Joint Photographic Experts Group (JPEG) 2000 compressed body computed tomography (CT) images, from the viewpoint of visually lossless compression approach. A total of 250 body CT images obtained with five different scan protocols (5-mm-thick abdomen, 0.67-mm-thick abdomen, 5-mm-thick lung, 0.67-mm-thick lung, and 5-mm-thick low-dose lung) were compressed to one of five CRs (reversible, 6:1, 8:1, 10:1, and 15:1). The PSNR and HDR-VDP values were calculated for the 250 pairs of the original and compressed images. By alternately displaying an original and its compressed image on the same monitor, five radiologists independently determined if the pair was distinguishable or indistinguishable. The kappa statistic for the interobserver agreement among the five radiologists' responses was 0.70. According to the radiologists' responses, the number of distinguishable image pairs tended to significantly differ among the five scan protocols at 6:1-10:1 compressions (Fisher-Freeman-Halton exact tests). Spearman's correlation coefficients between each of the CR, PSNR, and HDR-VDP and the number of radiologists who responded as distinguishable were 0.72, -0.77, and 0.85, respectively. Using the radiologists' pooled responses as the reference standards, the areas under the receiver-operating-characteristic curves for the CR, PSNR, and HDR-VDP were 0.87, 0.93, and 0.97, respectively, showing significant differences between the CR and PSNR (p=0.04), or HDR-VDP (p<0.001), and between the PSNR and HDR-VDP (p<0.001). In conclusion, the CR is less suitable than the PSNR or HDR-VDP as an objective index of image fidelity for JPEG2000 compressed body CT images. The HDR-VDP is more promising than the PSNR as such an index.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electrochemical Model Assessment of Strategies for Fast Charge

The United States Department of Energy (DOE) has identified extreme fast charging (XFC) as a critical challenge that must be overcome in order to achieve widespread adoption of electric vehicles. DOE’s eXtreme Fast Charge and Cell Evaluation (XCEL) program seeks to reduce charge time to 10-15 minutes for a 200+ Wh/kg Li-ion battery. This presentation for DOE’s Vehicle Technologies Program Annual Merit Review summarizes the XCEL team’s work developing electrochemical models to interpret data and applying them to identify best strategies to achieve fast charge. Strategies include advanced electrode architectures, elevated temperature charging, novel charge protocols, advanced electrolytes, thermal management and suppression of heterogeneities that cause early onset of the damaging Li plating side reaction.

47 OTHER INSTRUMENTATION↗

Lubricant impacts on piston deposit formation in the Enterprise marine diesel research engine

The impact of lubricant formulation on piston deposits was studied using the Enterprise, a reduced-scale, single-cylinder, two-stroke crosshead marine diesel research engine. The Enterprise engine was specially designed for marine diesel lubricant research, with a custom reduced-scale cylinder lubricant injection system and extensive instrumentation of thermal boundary conditions on both the liner and piston. Lubricant conditions typical of full-scale marine diesel engines are obtained by matching mean piston speed, liner temperature profile, and combustion metrics to realistic values.Piston deposit thicknesses were measured after a set period of operation, with a focus on lubricant-based deposits on the lands and ring grooves, using both optical and contact-based measurement techniques. Engine operation for each lubricant was conducted according to a standardized protocol, with precise control of engine speed and load, cylinder lubricant injection rate, coolant temperatures, and system oil temperature; the liner and piston temperatures are continuously monitored during operation. After operation with each lubricant was completed, the engine was disassembled, and the piston and ring deposits were characterized. The piston was then thoroughly cleaned, and the lubricant system flushed, between each lubricant formulation being evaluated. The impacts on piston deposits of the lubricants being evaluated can thus be accurately quantified and are described herein.

Kaul, Brian↗

Are System Baselines within OT Environments Feasible?

Critical infrastructure stakeholders need to baseline their systems to understand expected protocol communications.Baseline behaviors may vary based on operational context.Expected operations during a maintenance window, for example, may be different from normal operations.Furthermore, constructing system baselines for Industrial Control Systems (ICS) is difficult and time-consuming.ICS processes generate artifacts expressed across heterogeneous data sources such as network and device logs. There needs to be a corpus of data in order to develop and compare methods that evaluate the feasibility, performance, and generality of approaches to construct baselines for ICS events. Standalone repositories of network packet captures are insufficient to develop methods to classify or recognize operational events expressed across multiple data sources. Moreover, static data corpora do not enable researchers to compare the impact of changing the underlying system for which a baseline is being constructed and this limits the ability to evaluate the performance of system baselines given system changes (e.g. patches, configuration, maintenance events). In order to address these limitations within the community, this talk intends to promote discussion about the state of the practice of constructing baselines. In this manner, we can continue to understand requirements within industry that are not being met by current approaches to baseline construction. This talk builds on two previous talks on the topic of system baselines for OT environments. First, Weaver co-presented at the RSA Conference ICS Sandbox with Dan Gunter. The talk confirmed the need within industry to construct baselines across multiple types of data sources relative to the semantics of specific business processes. Second, Weaver presented at IEEE Security and Privacy Workshop on Language-Theoretic Security.

02 PETROLEUM↗