Search NASA⌕ Search

SEARCH · Search NASA

Results for “geometry optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

SU-E-T-326: Dosimetric Impact of Beam Energies and Jaw Tracking On Intracranial Tumors Using RapidArc

Purpose: To determine the dosimetric impact of jaw tracking and beam energies on dose conformity and normal-brain-tissue doses for intracranial tumors using VMAT (RapidArc). Methods: Seven patients with 1–2 and three patients with 4–6 intracranial tumors were planned using RapidArc for Varian TrueBeam STx machine with beam energies 6MV-FFF (Flattening-Filter-Free), 8MV, 10MV, and 10MV-FFF. The prescription dose ranged from 14–23Gy. Between 2 and 8 arcs were used with the following geometries: 2 full coplanar arcs and the non-coplanar half arcs. Plans were optimized (jaw tracking ON) with a high priority to Normal-Tissue-Objective and normal-brain-tissue. Plans were calculated on 1mm grid size using AAA algorithm and then normalized so that 99% of each target volume received the prescription dose. Plans for the 6MV-FFF were also optimized without jaw tracking (No-JT) for comparison. Plan quality was assessed by target coverage using Paddick Conformity Index (PCI), sparing of normal-brain-tissue through analysis of V4Gy, V8Gy and V12Gy, and integral dose. Results: The average PCI ± standard deviation was 0.76±0.21 and 0.76±0.22 for 6MV-FFF and 10 MV-FFF, respectively. The average ratio in normal brain tissue volume (reported as follows V4,V8,V12) were (1.12±0.07,1.12±0.07,1.14±0.04), (1.12±0.08,1.12±0.09,1.13±0.06), (1.19±0.10,1.18±0.10,1.20±0.04), and (1.04±0.03,1.03±0.03,1.03±0.04) for 8MV/6MV-FFF, 10MV-FFF/6MV-FFF, 10MV/6MV-FFF, 6MV-FFF No-JT/6MV-FFF, respectively. Statistically significant differences in normal-brain-tissue for V4, V8, and V12 were observed in all cases for the different energies (p-values <0.05). V4 data shows significant differences in JT vs. No-JT (p=0.04), however no difference was found for V8 and V12. Brain tissue sparing from best to worst occurred in this order 6MV-FFF, 6MV-FFF no-JT, 10MV-FFF, 8MV, and 10MV. The average ratio of integral brain dose was 1.05±0.04 (p=0.21), 1.04±0.05 (p=0.33), 1.09±0.06 (p=0.04), and 1.02±0.06 (p=0.61) for 8MV/6MV-FFF, 10MV-FFF/6MV-FFF, 10MV/6MV-FFF, and 6MV-FFF No-JT/6MV-FFF, respectively. Conclusion: Normal brain tissue and integral dose improved using the lower energy and FFF beams, though plan conformity showed energy independence.

60 APPLIED LIFE SCIENCES↗

A Modulated Differential Scanning Calorimetry Method for Characterization of Poly(ester urethane) Elastomer

A systematic series of experiments is presented utilizing MDSC to resolve the overlapping melt peaks found when analyzing poly(ester urethane) block copolymer elastomer by MDSC. Testing method parameters are idealized through diagnostic methods, leading to method parameters individualized to the material, which allow to optimize the MDSC method for the poly(ester urethane) characterization despite potentially problematic sample geometry. This is the second in a series of three reports on the degradation processes and physical properties of the materials used in polymer bonded explosive 9501.

36 MATERIALS SCIENCE↗

Multi-Probe Campaign FY24 Omega EP Shot Request [Slides]

The ultimate goal of the Multi-Probe experimental campaign is to assess the feasibility of using multiple probe species (x-ray, proton, neutron, and electron) in future LANL radiographic facilities. To use Omega EP most efficiently, two different experiments are proposed for each of the two requested days in FY24. In this way, shots may be interleaved on the two short pulse beams and the shot rate doubled. In FY24, we propose to continue to develop the neutron source by first optimizing the “pitcher” source of deuterons/protons and then adding the “catcher” neutron converter on day 2. The second series of experiments continues examining the origin and nature of the x-ray background found in our last two experiments. This background is not well understood or characterized by the community. The first day will measure the electrons emanating from the proton and x-ray targets while also optimizing the background shielding first used in FY23. The second day will test a geometry that enables simultaneous radiographs using both short-pulse beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Critical problems of energy frontier Muon Colliders: optics, magnets and radiation

This White Paper brings together our previous studies on a Muon Collider (MC) and presents a design concept of the 6 TeV MC optics, the superconducting (SC) magnets, and a preliminary analysis of the protection system to reduce magnet radiation loads as well as particle backgrounds in the detector. The SC magnets and detector protection considerations impose strict limitations on the lattice choice, hence the design of the collider optics, magnets and Machine Detector Interface (MDI) are closely intertwined. As a first approximation we use the Interaction Region (IR) design with beta-star=3 mm, whereas for the arcs we re-scale the arc cell design of the 3 TeV MC. Traditional cos-theta coil geometry and Nb3Sn superconductor were used to provide field maps for the analysis and optimization of the arc lattice and IR design, as well as for studies of beam dynamics and magnet protection against radiation. The stress management in the coil will be needed to avoid large degradation or even damage of the brittle SC coils. In the assumed IR designs, the dipoles close to the Interaction Point (IP) and tungsten masks in each IR (to protect magnets) help reducing background particle fluxes in the detector by a substantial factor. The tungsten nozzles in the 6 to 600 cm region from the IP, assisted by the detector solenoid field, trap most of the decay electrons created close to the IP as well as most of the incoherent electron-positron pairs generated in the IP. With sophisticated tungsten, iron, concrete and borated polyethylene shielding in the MDI region, the total reduction of background loads by more than three orders of magnitude can be achieved.

43 PARTICLE ACCELERATORS↗

Realization of a high luminosity muon beam at the Jefferson Lab

The proton is the major component of the visible matter of our universe, so being able to determine its fundamental properties, such as its charge radius, is of vital importance. In recent years, several experiments have been performed for the accurate measurement of the proton radius with different experimental techniques. The main and most common are based on two different techniques: ep scattering and Lamb shift spectroscopy of regular hydrogen atoms. The latter can also be performed on muonic hydrogen atoms with a significant improvement in accuracy. Recent measurements that use this method have highlighted a discrepancy between the results obtained with the diffusion of electrons and those obtained with the spectroscopic technique leading to the so-called ?proton radius puzzle?. The explanation of why this difference between the measured values exists is still a matter of discussion. The last attempt to address the puzzle was the PRad Experiment. It was performed with a unique experimental setup that gave the scientists an excellent control on the systematic errors that are usually present in electron-proton scattering experiments. This has significantly increased the precision of the measurement, bringing it in the same area as the spectroscopic ones done on muonic hydrogen atoms, which are considered the most precise. However, to solve the puzzle once and for all, even more precise electron scattering measurements are needed. Alternatively, new methods can be used, such as eg. muon-proton scattering at low transferred momenta in order to lower the systematic errors that comes with the measurement. This thesis tries to address this problem by studying the set up of an intense muon beam at the Jefferson Laboratory (JLab) that can be used to carry out a high-precision m ? p scattering experiment. Using Montecarlo simulations I studied the muon production resulting from the interaction of the primary electron beam with the beam-dump at JLab Hall-A. The simulations were performed using the FLUKA package via the FLAIR graphical interface. In this study, I modified an existing geometry (built for the ?Beam Dump eXperiment?) and performed several studies in order to optimize the muon beam parameters. In order to estimate the beam intensity, I studied the muon generation and transportation through the concrete bunker surrounding the Hall-A beam-dump. Detailed studies on muon attenuation and dispersion at different depth allowed me to track the beam profile in space and momentum as a function of the distance from the beam-dump. Last, but not least, I studied a possible tagging system for the muon beam. The tagging system will allow us to know with good precision (O(1=1000)) the energy of each muon of the beam. Based on the results obtained, I created an event generator that incorporates the detailed description of the muon beam (energy, position, emittance) useful to define and optimize the experimental setup for a future measurement of the proton radius at the JLab.

Fulci, Antonino↗

Collaborating CPU and GPU for large-scale high-order CFD simulations with complex grids on the TianHe-1A supercomputer

Programming and optimizing complex, real-world CFD codes on current many-core accelerated HPC systems is very challenging, especially when collaborating CPUs and accelerators to fully tap the potential of heterogeneous systems. In this paper, with a tri-level hybrid and heterogeneous programming model using MPI + OpenMP + CUDA, we port and optimize our high-order multi-block structured CFD software HOSTA on the GPU-accelerated TianHe-1A supercomputer. HOSTA adopts two self-developed high-order compact definite difference schemes WCNS and HDCS that can simulate flows with complex geometries. We present a dual-level parallelization scheme for efficient multi-block computation on GPUs and perform particular kernel optimizations for high-order CFD schemes. The GPU-only approach achieves a speedup of about 1.3 when comparing one Tesla M2050 GPU with two Xeon X5670 CPUs. To achieve a greater speedup, we collaborate CPU and GPU for HOSTA instead of using a naive GPU-only approach. We present a novel scheme to balance the loads between the store-poor GPU and the store-rich CPU. Taking CPU and GPU load balance into account, we improve the maximum simulation problem size per TianHe-1A node for HOSTA by 2.3×, meanwhile the collaborative approach can improve the performance by around 45% compared to the GPU-only approach. Further, to scale HOSTA on TianHe-1A, we propose a gather/scatter optimization to minimize PCI-e data transfer times for ghost and singularity data of 3D grid blocks, and overlap the collaborative computation and communication as far as possible using some advanced CUDA and MPI features. Scalability tests show that HOSTA can achieve a parallel efficiency of above 60% on 1024 TianHe-1A nodes. With our method, we have successfully simulated an EET high-lift airfoil configuration containing 800M cells and China's large civil airplane configuration containing 150M cells. To our best knowledge, those are the largest-scale CPU–GPU collaborative simulations that solve realistic CFD problems with both complex configurations and high-order schemes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MAGNETO-FRICTIONAL MODELING OF CORONAL NONLINEAR FORCE-FREE FIELDS. I. TESTING WITH ANALYTIC SOLUTIONS

We report our implementation of the magneto-frictional method in the Message Passing Interface Adaptive Mesh Refinement Versatile Advection Code (MPI-AMRVAC). The method aims at applications where local adaptive mesh refinement (AMR) is essential to make follow-up dynamical modeling affordable. We quantify its performance in both domain-decomposed uniform grids and block-adaptive AMR computations, using all frequently employed force-free, divergence-free, and other vector comparison metrics. As test cases, we revisit the semi-analytic solution of Low and Lou in both Cartesian and spherical geometries, along with the topologically challenging Titov–Démoulin model. We compare different combinations of spatial and temporal discretizations, and find that the fourth-order central difference with a local Lax–Friedrichs dissipation term in a single-step marching scheme is an optimal combination. The initial condition is provided by the potential field, which is the potential field source surface model in spherical geometry. Various boundary conditions are adopted, ranging from fully prescribed cases where all boundaries are assigned with the semi-analytic models, to solar-like cases where only the magnetic field at the bottom is known. Our results demonstrate that all the metrics compare favorably to previous works in both Cartesian and spherical coordinates. Cases with several AMR levels perform in accordance with their effective resolutions. The magneto-frictional method in MPI-AMRVAC allows us to model a region of interest with high spatial resolution and large field of view simultaneously, as required by observation-constrained extrapolations using vector data provided with modern instruments. The applications of the magneto-frictional method to observations are shown in an accompanying paper.

79 ASTRONOMY AND ASTROPHYSICS↗

CONFIDANTE Demonstration Prototype Report

This report summarizes design optimization and performance evaluation studies for a new prototype CONFIDANTE (CONfirmation using a Fast-neutron Imaging Detector with Anti-image Null-positive Time Encoding) warhead confirmation system. It was found that a spherical mask geometry and a 2” diameter cylindrical central detector is expected to best discriminate between the parametrically varied source distributions that were evaluated. The optimized design as fabricated and its performance was evaluated in a series of laboratory measurements. The performance was in good agreement with the design studies, with demonstrated discrimination between objects with differences in scale on the order of 5 centimeters or better at 1 meter stand-off

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated divertor target design by adjoint shape sensitivity analysis and a one-shot method

As magnetic confinement fusion progresses towards the development of first reactor-scale devices, computational tokamak divertor design is a topic of high priority. Presently, edge plasma codes are used in a forward approach, where magnetic field and divertor geometry are manually adjusted to meet design requirements. Due to the complex edge plasma flows and large number of design variables, this method is computationally very demanding. On the other hand, efficient optimization-based design strategies have been developed in computational aerodynamics and fluid mechanics. Such an optimization approach to divertor target shape design is elaborated in the present paper. A general formulation of the design problems is given, and conditions characterizing the optimal designs are formulated. Using a continuous adjoint framework, design sensitivities can be computed at a cost of only two edge plasma simulations, independent of the number of design variables. Furthermore, by using a one-shot method the entire optimization problem can be solved at an equivalent cost of only a few forward simulations. The methodology is applied to target shape design for uniform power load, in simplified edge plasma geometry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V{sub 100}{sup Prostate}>90%) and organ-at-risk dose sparing (V{sub 75}{sup Bladder}<1 cc, V{sub 75}{sup Rectum}<1 cc, V{sub 125}{sup Urethra}<<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter patterns may decrease toxicity by avoidance of the critical structures near the penile bulb while still fulfilling the RTOG criteria.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimization of Micro Metal Injection Molding By Using Grey Relational Grade

Micro metal injection molding ({mu}MIM) which is a variant of MIM process is a promising method towards near net-shape of metallic micro components of complex geometry. In this paper, {mu}MIM is applied to produce 316L stainless steel micro components. Due to highly stringent characteristic of {mu}MIM properties, the study has been emphasized on optimization of process parameter where Taguchi method associated with Grey Relational Analysis (GRA) will be implemented as it represents novel approach towards investigation of multiple performance characteristics. Basic idea of GRA is to find a grey relational grade (GRG) which can be used for the optimization conversion from multi objectives case which are density and strength to a single objective case. After considering the form 'the larger the better', results show that the injection time(D) is the most significant followed by injection pressure(A), holding time(E), mold temperature(C) and injection temperature(B). Analysis of variance (ANOVA) is also employed to strengthen the significant of each parameter involved in this study.

36 MATERIALS SCIENCE↗

An optimization method for flexural bearing design for high-stroke high-frequency applications

A method for optimization of a high-stroke, high-frequency flexural bearing was completed. The main goal was to design a flexural bearing system as the energy restoration component of a one kW free piston linear engine alternator (LEA) operating at 90 Hz and maximum targeted displacement of 22 mm. Defined electricity output of 1 kW, with more than 30% efficiency, required engine operation under high speed and high stroke conditions. Under such challenging stroke and frequency requirements, a method of design was required to select between a wide range of parameters in flexural bearing design. A parametric CAD model was prepared and used in the optimization package of a finite element analysis (FEA) software. Four main parameters of flexural bearing geometry were identified and included the outer diameter, thickness, number of arms, and sweep angle of spiral cuts. Other design parameters including spiral gap width, shape factor and spiral start points angle were shown to be less important compared to these four main parameters in primary design and were examined separately. A neural network algorithm was used to investigate the interactions and effects of design parameters. The sensitivity of each parameter on output criteria such as maximum stress and natural frequency was examined and design charts developed. Methods for further modification of the spiral curve at end points were introduced to reduce the maximum stress level by up to 20%. Several steel alloys and a titanium-based alloy were identified as proper material candidates for high cycle applications and the final designed spring was manufactured and tested to validate the FEA results of axial stiffness and strain level throughout the flexure arms. The percent of the flexure’s moving mass was estimated to be 29% with FEA analysis and compared well with the experimental value of 31%. The stress/strain results of the FEA analysis matched with the experimental results – within ±5%.

42 ENGINEERING↗

Modeling the electrode geometry of co-planar capacitors for the microwave dielectric characterization of ceramic thin films

This paper describes the influence of co-planar electrode geometry on the measurement accuracy of microwave dielectric properties of sol-gel-derived Na{sub 0.5}Bi{sub 0.5}TiO{sub 3}-NaTaO{sub 3} thin films. The interdigital, co-planar capacitor configurations were prepared with E-beam lithography. A combination of analytical and numerical modelling was used for the optimization of co-planar, interdigital electrode structures for the thin-film characterization. We observed that the number of fingers, their length, as well as the gap between the fingers of the interdigital electrode structure of the co-planar capacitor have a pronounced influence on the accuracy of measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Block-Structured Adaptive Mesh Framework to Solve Radiation Transfer Equation in Irregular Embedded Geometries

Radiation transport arises in various scientific, industrial, and medical fields, and understanding its effect in applications is needed to make accurate predictions, safety assessments and performance optimizations. Solving the Radiation Transport Equation (RTE) is challenging due to its integro-differential nature, which involves both differential and integral terms. The differential term describes the change in radiation intensity due to absorption and emission, while the integral term accounts for scattering. The accurate modeling of radiation is further complicated in many applications due to the complex, irregular geometries. Various methods exist for solving the RTE, including the zonal, Monte Carlo, spherical harmonics, discrete ordinates, and finite volume methods. Traditional mesh-based approaches, which rely on structured or unstructured meshes, struggle with irregular geometries due to: a) the difficulty of conforming structured grids to irregular domains, b) challenges in enforcing boundary conditions correctly, and c) the additional computational cost of unstructured mesh methods. This work presents a second-order accurate method for solving the RTE in irregular geometries. The radiation intensity is discretized using the finite-volume method in both spatial and angular directions on regular Cartesian grid blocks. Leveraging the block-structured adaptive mesh refinement (AMR) framework provided by AMReX, our method refines the grid locally to reduce spatial discretization error, ensuring a converged numerical solution while minimizing computational costs elsewhere. A two-stage deferred correction approach is employed: First, a first-order discretization on grid blocks is solved using an algebraic multigrid method in HYPRE. Second, a correction term is applied explicitly to achieve second-order accuracy. The correction term is calculated by approximating the radiation flux on cell faces using a Total Variation Diminishing (TVD) scheme. This approach ensures quick convergence of the multigrid method while preserving higher-order accuracy of the numerical solution. Irregular geometries are resolved as embedded boundaries (EB), resulting in both cut cells and regular cells. In cut cells, we modify the fluxes using face fractions and incorporate additional contributions from EB boundary conditions. To ensure higher-order convergence near the EB interface, the correction term is modified by interpolating the radiation intensity to fictitious ghost points. The implementation takes advantage of modern supercomputers by leveraging AMReX’sMPI/X parallelization strategy where X can be MPI or a GPU accelerator including CUDA, HIP and DPC++. We validate our solver using classical test cases, both with and without EB, demonstrating accuracy and efficiency. Additionally, we analyze the impact of adaptive mesh refinement on solution accuracy and computational cost, highlighting the advantages of our approach for high-resolution radiation transport simulations.

computational fluid dynamics (CFD)↗

3D high-fidelity automated neutronics guided optimization of fusion blanket designs

The compact Fusion Pilot Plant (FPP) is defined in the recent National Academies of Sciences, Engineering, and Medicine report as the next step of fusion energy demonstration with a $50$ MWe peak net electricity production, $Q_e$ greater than $1$, and at least $3$ hours of continuous operation. This fusion pilot plant will be a test bed enabling materials, designs, and fuel management assessment, and it will represent an engineering challenge because of its high-fusion power and compact design targets. Previous reactor data is limited to experiments operating in different design space ranges. Therefore, design iterations and assessments should rely on high-fidelity first-principle theoretical and computational models. The high-fidelity integrated modeling of the plasma is a fundamental part of fusion energy research. However, the whole device modeling is often neglected, utilizing low-fidelity, system-level analysis. Recently, the need for high-fidelity multi-physics modeling was recognized, resulting in a selection of integrated tools. Further, autonomous design optimization requires a streamlined framework that perturbs the design point, reruns the analysis, and examines the outputs. However, high-fidelity analysis requires complex geometry specification that is difficult to perturb. This work presents the parametric CAD generation tool TRACER and a new neutronic workflow. TRACER allows the perturbation of the geometry representation, creating geometry files ready for further analysis. The streamlined neutronic workflow allows efficient and accurate calculations. The two new tools coupled together were used to perform a 3D high-fidelity multi-objective, multi-input optimization of an "ARC Class" compact tokamak design. The workflow was driven by an optimization driver for full automation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiobiologic comparison of helical tomotherapy, intensity modulated radiotherapy, and conformal radiotherapy in treating lung cancer accounting for secondary malignancy risks

The aim of the present study is to examine the importance of using measures to predict the risk of inducing secondary malignancies in association with the clinical effectiveness of treatment plans in terms of tumor control and normal tissue complication probabilities. This is achieved by using radiobiologic parameters and measures, which may provide a closer association between clinical outcome and treatment delivery. Overall, 4 patients having been treated for lung cancer were examined. For each of them, 3 treatment plans were developed based on the helical tomotherapy (HT), multileaf collimator-based intensity modulated radiation therapy (IMRT), and 3-dimensional conformal radiation therapy (CRT) modalities. The different plans were evaluated using the complication-free tumor control probability (p{sub +}), the overall probability of injury (p{sub I}), the overall probability of control/benefit (p{sub B}), and the biologically effective uniform dose (D{sup ¯¯}). These radiobiologic measures were used to develop dose-response curves (p-D{sup ¯¯} diagram), which can help to evaluate different treatment plans when used in conjunction with standard dosimetric criteria. The risks for secondary malignancies in the heart and the contralateral lung were calculated for the 3 radiation modalities based on the corresponding dose-volume histograms (DVHs) of each patient. Regarding the overall evaluation of the different radiation modalities based on the p{sub +} index, the average values of the HT, IMRT, and CRT are 67.3%, 61.2%, and 68.2%, respectively. The corresponding average values of p{sub B} are 75.6%, 70.5%, and 71.0%, respectively, whereas the average values of p{sub I} are 8.3%, 9.3%, and 2.8%, respectively. Among the organs at risk (OARs), lungs show the highest probabilities for complications, which are 7.1%, 8.0%, and 1.3% for the HT, IMRT, and CRT modalities, respectively. Similarly, the biologically effective prescription doses (D{sub B}{sup ¯¯}) for the HT, IMRT, and CRT modalities are 64.0, 60.9, and 60.8 Gy, respectively. Regarding the risk for secondary cancer, for the heart, the lowest average risk is produced by IMRT (0.10%) compared with the HT (0.17%) and CRT (0.12%) modalities, whereas the 3 radiation modalities show almost equivalent results regarding the contralateral lung (0.8% for HT, 0.9% for IMRT, and 0.9% for CRT). The use of radiobiologic parameters in the evaluation of different treatment plans and estimation of their expected clinical outcome is shown to provide very useful clinical information. The radiobiologic analysis of the response probabilities showed that different radiation modalities appear to be more effective in different patient geometries and target sizes and locations. Furthermore, there is not a clear pattern between the plans that appear to be more effective for the treatment and the risk of secondary malignancy. It seems that radiobiologically based treatment planning taking into account the risk of secondary cancer can be established as an effective clinical tool for a more clinically relevant treatment optimization.

61 RADIATION PROTECTION AND DOSIMETRY↗

Proximal Galerkin: A Structure-Preserving Finite Element Method for Pointwise Bound Constraints

The proximal Galerkin finite element method is a high-order, low iteration complexity, nonlinear numerical method that preserves the geometric and algebraic structure of pointwise bound constraints in infinite-dimensional function spaces. This paper introduces the proximal Galerkin method and applies it to solve free boundary problems, enforce discrete maximum principles, and develop a scalable, mesh-independent algorithm for optimal design with pointwise bound constraints. This paper also introduces the latent variable proximal point (LVPP) algorithm, from which the proximal Galerkin method derives. When analyzing the classical obstacle problem, we discover that the underlying variational inequality can be replaced by a sequence of second-order partial differential equations (PDEs) that are readily discretized and solved with, e.g., the proximal Galerkin method. Throughout this work, we arrive at several contributions that may be of independent interest. These include (1) a semilinear PDE we refer to as the entropic Poisson equation; (2) an algebraic/geometric connection between high-order positivity-preserving discretizations and certain infinite-dimensional Lie groups; and (3) a gradient-based, bound-preserving algorithm for two-field, density-based topology optimization. The complete proximal Galerkin methodology combines ideas from nonlinear programming, functional analysis, tropical algebra, and differential geometry and can potentially lead to new synergies among these areas as well as within variational and numerical analysis. Open-source implementations of our methods accompany this work to facilitate reproduction and broader adoption.

97 MATHEMATICS AND COMPUTING↗

Optimization of Energy Absorbing Materials for Radioactive Packaging

Most applications of honeycomb materials are for lightweight structural members. This area of honeycomb material behavior has been extensively researched. In packaging design, honeycomb materials are used for impact energy absorption. Data concerning the deformation of stainless steel honeycomb structures is not widely available. It is being proposed to use honeycomb stainless steel as an impact energy absorber in a new radioactive material shipping package. Honeycomb materials can be useful for energy absorption applications because the geometry causes the structure to have a constant compressive force during buckling. This Finite Element Analysis is used to predict the compressive buckling strength of various honeycomb structures in order to design an energy absorber for a specific package weight and geometry. The model simulates a drop test where a 50 pound plate lands flat on a honeycomb stainless steel structure from a height of 30 feet. Some actual drop tests have already been performed on real specimens. Most of the resulting deformations of these tests include the bottom of the honeycomb structure buckling while the rest of the structure was either slightly deformed or straight. The deformation of the simulated honeycomb specimen matched the deformation from the actual drop tests. This is one verification that the model is working properly. It is evident that after about 2.5% strain the strength is a relatively linear value, and eventually flattens out to about 875 psi. The crush strength measured from the actual drop tests for the same density honeycomb was just over 800 psi. This is further verification that the model is working correctly. The results gathered from the FEA model successfully mirror the results from a real drop test. The deformation looks realistic, and the compressive strength found is consistent with the empirically measured value. Future work for this model includes modeling different density honeycomb structures which have not been tested before. This will allow for optimization of honeycomb stainless steel use for impact absorption in radioactive material shipping packages.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗