Search NASA⌕ Search

SEARCH · Search NASA

Results for “image based modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

The Solar Chromosphere/Corona Interface. I. Far-Ultraviolet to Extreme-Ultraviolet Observations and Modeling of Unresolved Coronal Funnels

A coronal funnel model, developed by D. Rabin, was tested against a calibrated spectroheliogram recorded in the 170-1 75 A bandpass. This image was recorded on board a sounding-rocket experiment flown on 1994 November 3, called the Multi-Spectral Solar Telescope Array II (MSSTA II). MSSTA, a joint project of Stanford University, the NASA Marshall Space Flight Center, and the Lawrence Livermore National Laboratory' is an observing platform composed of a set of normal-incidence, multilayer-coated optics designed to obtain narrow-bandpass, high-resolution images (1 sec.- 3 sec.) at selected far-ultraviolet (FUV), extreme-ultraviolet (EUV), and soft X-ray wavelengths (44-1550 A). Using full disk images centered at 1550 A (C IV) and 173 A (Fe IX/X), the funnel model, which is based on coronal back-heating, was tested against the data incorporating observed constraints on global coverage and measured flux. Found was a class of funnel models that could account for the quiescent, globally diffuse and unresolved emission seen in the 171-175 A bandpass, where the funnels are assumed to be rooted in the C IV supergranular network. These models, when incorporated with the CHIANTI spectral code, suggest that this emission is mostly of upper transition region origin and primarily composed of Fe IX plasma. The funnels are found to have constrictions, Gamma approx. 6-20, which is in good agreement with the observations. Further, the fitted models simultaneously satisfy global areal constraints seen in both images; namely,that a global network of funnels must cover approx. 700 - 95% of the total solar surface area seen in the 171-175 A image, and a 5% of the disk area seen in the 1550 A bandpass. These findings support the configuration of the EUV magnetic network as suggested by Reeves et al. and put forth in more detail by Gabriel. Furthermore, the models are in good agreement with differential emission measure estimates made of the transition region by J. C. Raymond & J. G. Doyle for temperatures 250,000 K less than or = T less than or = 650,000 K, based on full-disk observations made on board Skylab.

Martinez-Galarce, Dennis S.↗

{sup 18}F-FLT uptake kinetics in head and neck squamous cell carcinoma: A PET imaging study

Purpose: To analyze the kinetics of 3{sup ′}-deoxy-3{sup ′}-[F-18]-fluorothymidine (18F-FLT) uptake by head and neck squamous cell carcinomas and involved nodes imaged using positron emission tomography (PET). Methods: Two- and three-tissue compartment models were fitted to 12 tumor time-activity-curves (TACs) obtained for 6 structures (tumors or involved nodes) imaged in ten dynamic PET studies of 1 h duration, carried out for five patients. The ability of the models to describe the data was assessed using a runs test, the Akaike information criterion (AIC) and leave-one-out cross-validation. To generate parametric maps the models were also fitted to TACs of individual voxels. Correlations between maps of different parameters were characterized using Pearson'sr coefficient; in particular the phosphorylation rate-constants k{sub 3-2tiss} and k{sub 5} of the two- and three-tissue models were studied alongside the flux parameters K{sub FLT-2tiss} and K{sub FLT} of these models, and standardized uptake values (SUV). A methodology based on expectation-maximization clustering and the Bayesian information criterion (“EM-BIC clustering”) was used to distil the information from noisy parametric images. Results: Fits of two-tissue models 2C3K and 2C4K and three-tissue models 3C5K and 3C6K comprising three, four, five, and six rate-constants, respectively, pass the runs test for 4, 8, 10, and 11 of 12 tumor TACs. The three-tissue models have lower AIC and cross-validation scores for nine of the 12 tumors. Overall the 3C6K model has the lowest AIC and cross-validation scores and its fitted parameter values are of the same orders of magnitude as literature estimates. Maps ofK{sub FLT} and K{sub FLT-2tiss} are strongly correlated (r = 0.85) and also correlate closely with SUV maps (r = 0.72 for K{sub FLT-2tiss}, 0.64 for K{sub FLT}). Phosphorylation rate-constant maps are moderately correlated with flux maps (r = 0.48 for k{sub 3-2tiss} vs K{sub FLT-2tiss} and r = 0.68 for k{sub 5} vs K{sub FLT}); however, neither phosphorylation rate-constant correlates significantly with SUV. EM-BIC clustering reduces the parametric maps to a small number of levels—on average 5.8, 3.5, 3.4, and 1.4 for K{sub FLT-2tiss}, K{sub FLT}, k{sub 3-2tiss}, and k{sub 5.} This large simplification is potentially useful for radiotherapy dose-painting, but demonstrates the high noise in some maps. Statistical simulations show that voxel level noise degrades TACs generated from the 3C6K model sufficiently that the average AIC score, parameter bias, and total uncertainty of 2C4K model fits are similar to those of 3C6K fits, whereas at the whole tumor level the scores are lower for 3C6K fits. Conclusions: For the patients studied here, whole tumor FLT uptake time-courses are represented better overall by a three-tissue than by a two-tissue model. EM-BIC clustering simplifies noisy parametric maps, providing the best description of the underlying information they contain and is potentially useful for radiotherapy dose-painting. However, the clustering highlights the large degree of noise present in maps of the phosphorylation rate-constantsk{sub 5} and k{sub 3-2tiss}, which are conceptually tightly linked to cellular proliferation. Methods must be found to make these maps more robust—either by constraining other model parameters or modifying dynamic imaging protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In situ edge engineering in two-dimensional transition metal dichalcogenides

Exerting synthetic control over the edge structure and chemistry of two-dimensional (2D) materials is of critical importance to direct the magnetic, optical, electrical, and catalytic properties for specific applications. Here in this study, we directly image the edge evolution of pores in Mo 1-x W x Se 2 monolayers via atomic-resolution in situ scanning transmission electron microscopy (STEM) and demonstrate that these edges can be structurally transformed to theoretically predicted metastable atomic configurations by thermal and chemical driving forces. Density functional theory calculations and ab initio molecular dynamics simulations explain the observed thermally induced structural evolution and exceptional stability of the four most commonly observed edges based on changing chemical potential during thermal annealing. Finally, the coupling of modeling and in situ STEM imaging in changing chemical environments demonstrated here provides a pathway for the predictive and controlled atomic scale manipulation of matter for the directed synthesis of edge configurations in Mo 1-x W x Se 2 to achieve desired functionality.

36 MATERIALS SCIENCE↗

Shell-NASA Vibration-Based Damage Characterization

This article describes collaborative research between Shell International Exploration and Production (IE&P) scientists and ISAG personnel to investigate the feasibility of ultrasonic-based characterization of spacecraft tile damage for in-space inspection applications. The approach was proposed by Shell personnel in a Shell-NASA "speed-matching" session in early 2011 after ISAG personnel described challenges inherent in the inspection of MMOD damage deep within spacecraft thermal protection system (TPS) tiles. The approach leveraged Shell's relevant sensor and analytical expertise. The research addressed the difficulties associated with producing 3D models of MMOD damage cavities under the surface of a TPS tile, given that simple image-based sensing is constrained by line of sight through entry holes that have diameters considerably smaller than the underlying damage cavities. Damage cavity characterization is needed as part of a vehicle inspection and risk reduction capability for long-duration, human-flown space missions. It was hoped that cavity characterization could be accomplished through the use of ultrasonic techniques that allow for signal penetration through solid material.

Rollins, John M.↗

Natural and Induced Fracture Diagnostics from 4-D VSP Low Permeability Gas Reservoirs

Tight gas sand reservoirs generally contain thick gas-charged intervals that often have low porosity and very low permeability. Natural and induced fractures provide the only means of production. The objective of this work is to locate and characterize natural and induced fractures from analysis of scattered waves recorded on 4-D (time lapse) VSP data in order to optimize well placement and well spacing in these gas reservoirs. Using model data simulating the scattering of seismic energy from hydraulic fractures, we first show that it is possible to characterize the quality of fracturing based upon the amount of scattering. In addition, the picked arrival times of recorded microseismic events provide the velocity moveout for isolating the scattered energy on the 4-D VSP data. This concept is applied to a field dataset from the Jonah Field in Wyoming to characterize the quality of the induced hydraulic fractures. The time lapse (4D) VSP data from this field are imaged using a migration algorithm that utilizes shot travel time tables derived from the first breaks of the 3D VSPs and receiver travel time tables based on the microseismic arrival times and a regional velocity model. Four azimuthally varying shot tables are derived from picks of the first breaks of over 200 VSP records. We create images of the fracture planes through two of the hydraulically fractured wells in the field. The scattered energy shows correlation with the locations of the microseismic events. In addition, the azimuthal scattering is different from the azimuthal reflectivity of the reservoir, giving us more confidence that we have separated the scattered signal from simple formation reflectivity. Variation of the scattered energy along the image planes suggests variability in the quality of the fractures in three distinct zones.

03 NATURAL GAS↗

Digital image gathering and minimum mean-square error restoration

Most digital image restoration algorithms are inherently incomplete because they are conditioned on a discrete-input, discrete-output model which only accounts for blurring during image gathering and additive noise. For those restoration applications where sampling and reconstruction are important, the restoration algorithm should be based on a more comprehensive end-to-end model which also accounts for the potentially important noiselike effects of aliasing and the low-pass filtering effects of interpolative reconstruction. It is demonstrated that although the mathematics of this more comprehensive model is more complex, the increase in complexity is not so great as to prevent a complete development and analysis of the associated minimum mean-square error (Wiener) restoration filter.

Park, Stephen K.↗

Neural networks for modeling and control of particle accelerators

Charged particle accelerators support a wide variety of scientific, industrial, and medical applications. They range in scale and complexity from systems with just a few components for beam acceleration and manipulation, to large scientific user facilities that span many kilometers and have hundreds-to-thousands of individually-controllable components. Specific operational requirements must be met by adjusting the many controllable variables of the accelerator. Meeting these requirements can be challenging, both in terms of the ability to achieve specific beam quality metrics in a reliable fashion and in terms of the time needed to set up and maintain the optimal operating conditions. One avenue toward addressing this challenge is to incorporate techniques from the fields of machine learning (ML) and artificial intelligence (AI) into the way particle accelerators are modeled and controlled. While many promising approaches within AI/ML could be used for particle accelerators, this dissertation focuses on approaches based on neural networks. Neural networks are particularly well-suited to modeling, control, and diagnostic analysis of nonlinear systems, as well as systems with large parameter spaces. They are also very appealing for their ability to process high-dimensional data types, such as images and time series (both of which are ubiquitous in particle accelerators). In this work, key studies that demonstrated the potential utility of modern neural network-based approaches to modeling and control of particle accelerators are presented. The context for this work is important: at the start of this work in 2012, there was little interest in AI/ML in the particle accelerator community, and many of the advances in neural networks and deep learning that enabled its present success had not yet been made at that time. As such, this work was both an exploration of possible application areas and a generator of proof-of-concept demonstrations in these areas.

43 PARTICLE ACCELERATORS↗

Quantifying leaf symptoms of sorghum charcoal rot in images of field‐grown plants using deep neural networks

Abstract Charcoal rot of sorghum (CRS) is a significant disease affecting sorghum crops, with limited genetic resistance available. The causative agent, Macrophomina phaseolina (Tassi) Goid, is a highly destructive fungal pathogen that targets over 500 plant species globally, including essential staple crops. Utilizing field image data for precise detection and quantification of CRS could greatly assist in the prompt identification and management of affected fields and thereby reduce yield losses. The objective of this work was to implement various machine learning algorithms to evaluate their ability to accurately detect and quantify CRS in red‐green‐blue images of sorghum plants exhibiting symptoms of infection. EfficientNet‐B3 and a fully convolutional network emerged as the top‐performing models for image classification and segmentation tasks, respectively. Among the classification models evaluated, EfficientNet‐B3 demonstrated superior performance, achieving an accuracy of 86.97%, a recall rate of 0.71, and an F1 score of 0.73. Of the segmentation models tested, FCN proved to be the most effective, exhibiting a validation accuracy of 97.76%, a recall rate of 0.68, and an F1 score of 0.66. As the size of the image patches increased, both models’ validation scores increased linearly, and their inference time decreased exponentially. This trend could be attributed to larger patches containing more information, improving model performance, and fewer patches reducing the computational load, thus decreasing inference time. The models, in addition to being immediately useful for breeders and growers of sorghum, advance the domain of automated plant phenotyping and may serve as a foundation for drone‐based or other automated field phenotyping efforts. Additionally, the models presented herein can be accessed through a web‐based application where users can easily analyze their own images.

Gonzalez, Emmanuel M.↗

Surveying the agents of galaxy evolution in the tidally stripped, low metallicity small Magellanic Cloud (SAGE-SMC). III. Young stellar objects

The Spitzer Space Telescope Legacy Program SAGE-SMC allows global studies of resolved stellar populations in the SMC in a different environment than our Galaxy. Using the SAGE-SMC IRAC (3.6-8.0 μm) and MIPS (24 and 70 μm) catalogs and images combined with near-infrared (JHK {sub s}) and optical (UBVI) data, we identified a population of ∼1000 intermediate- to high-mass young stellar objects (YSOs) in the SMC (three times more than previously known). Our method of identifying YSO candidates builds on the method developed for the Large Magellanic Cloud by Whitney et al. with improvements based on what we learned from our subsequent studies and techniques described in the literature. We perform (1) color-magnitude cuts based on five color-magnitude diagrams (CMDs), (2) visual inspection of multi-wavelength images, and (3) spectral energy distribution (SED) fitting with YSO models. For each YSO candidate, we use its photometry to calculate a measure of our confidence that the source is not a non-YSO contaminant, but rather a true YSO, based on the source's location in the color-magnitude space with respect to non-YSOs. We use this CMD score and the SED fitting results to define two classes of sources: high-reliability YSO candidates and possible YSO candidates. We found that, due to polycyclic aromatic hydrocarbon emission, about half of our sources have [3.6]-[4.5] and [4.5]-[5.8] colors not predicted by previous YSO models. The YSO candidates are spatially correlated with gas tracers.

79 ASTRONOMY AND ASTROPHYSICS↗

A Plug-and-Play Priors Approach for Solving Nonlinear Imaging Inverse Problems

In the past two decades, nonlinear image reconstruction methods have led to substantial improvements in the capabilities of numerous imaging systems. Such methods are traditionally formulated as optimization problems that are solved iteratively by simultaneously enforcing data consistency and incorporating prior models. Recently, the Plug-and-Play Priors (PPP) framework suggested that by using more sophisticated denoisers, not necessarily corresponding to an optimization objective, it is possible to improve the quality of reconstructed images. Here in this letter, we show that the PPP approach is applicable beyond linear inverse problems. In particular, we develop the fast iterative shrinkage/thresholding algorithm variant of PPP for model-based nonlinear inverse scattering. The key advantage of the proposed formulation over the original ADMM-based one is that it does not need to perform an inversion on the forward model. We show that the proposed method produces high quality images using both simulated and experimentally measured data.

97 MATHEMATICS AND COMPUTING↗

SU-E-J-205: Monte Carlo Modeling of Ultrasound Probes for Real-Time Ultrasound Image-Guided Radiotherapy

Purpose: To quantify the effect of ultrasound (US) probe beam attenuation for radiation therapy delivered under real-time US image guidance by means of Monte Carlo (MC) simulations. Methods: MC models of two Philips US probes, an X6-1 matrix-array transducer and a C5-2 curved-array transducer, were built based on their CT images in the EGSnrc BEAMnrc and DOSXYZnrc codes. Due to the metal parts, the probes were scanned in a Tomotherapy machine with a 3.5 MV beam. Mass densities in the probes were assigned based on an electron density calibration phantom consisting of cylinders with mass densities between 0.2–8.0 g/cm{sup 3}. Beam attenuation due to the probes was measured in a solid water phantom for a 6 MV and 15 MV 15x15 cm{sup 2} beam delivered on a Varian Trilogy linear accelerator. The dose was measured with the PTW-729 ionization chamber array at two depths and compared to MC simulations. The extreme case beam attenuation expected in robotic US image guided radiotherapy for probes in upright position was quantified by means of MC simulations. Results: The 3.5 MV CT number to mass density calibration curve was found to be linear with R{sup 2} > 0.99. The maximum mass densities were 4.6 and 4.2 g/cm{sup 3} in the C5-2 and X6-1 probe, respectively. Gamma analysis of the simulated and measured doses revealed that over 98% of measurement points passed the 3%/3mm criteria for both probes and measurement depths. The extreme attenuation for probes in upright position was found to be 25% and 31% for the C5-2 and X6-1 probe, respectively, for both 6 and 15 MV beams at 10 cm depth. Conclusion: MC models of two US probes used for real-time image guidance during radiotherapy have been built. As a Result, radiotherapy treatment planning with the imaging probes in place can now be performed. J Schlosser is an employee of SoniTrack Systems, Inc. D Hristov has financial interest in SoniTrack Systems, Inc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous Characterization of Wildfire Smoke and Surface Properties With Imaging Spectroscopy During the FIREX-AQ Field Campaign

We introduce and evaluate an approach for the simultaneous retrieval of aerosol and surface properties from Airborne Visible/Infrared Imaging Spectrometer Classic (AVIRIS-C) data collected during wildfires. The joint National Aeronautics and Space Administration (NASA) National Oceanic and Atmospheric Administration Fire Influence on Regional to Global Environments and Air Quality field campaign took place in August 2019, and involved two aircraft and coordinated ground-based observations. The AVIRIS-C instrument acquired data from onboard NASA's high altitude ER-2 research aircraft, coincident in space and time with aerosol observations obtained from the Aerosol Robotic Network (AERONET) DRAGON mobile platform in the smoke plume downwind of the Williams Flats Fire in northern Washington in August 2019. Observations in this smoke plume were used to assess the capacity of optimal-estimation based retrievals to simultaneously estimate aerosol optical depth (AOD) and surface reflectance from Visible Shortwave Infrared (VSWIR) imaging spectroscopy. Radiative transfer modeling of the sensitivities in spectral information collected over smoke reveal the potential capacity of high spectral resolution retrievals to distinguish between sulfate and smoke aerosol models, as well as sensitivity to the aerosol size distribution. Comparison with ground-based AERONET observations demonstrates that AVIRIS-C retrievals of AOD compare favorably with direct sun AOD measurements. Our analyses suggest that spectral information collected from the full VSWIR spectral interval, not just the shortest wavelengths, enables accurate retrievals. We use this approach to continuously map both aerosols and surface reflectance at high spatial resolution across heterogeneous terrain, even under relatively high AOD conditions associated with wildfire smoke.

FIREX-AQ↗

A multimodality segmentation framework for automatic target delineation in head and neck radiotherapy

Purpose: To develop an automatic segmentation algorithm integrating imaging information from computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI) to delineate target volume in head and neck cancer radiotherapy. Methods: Eleven patients with unresectable disease at the tonsil or base of tongue who underwent MRI, CT, and PET/CT within two months before the start of radiotherapy or chemoradiotherapy were recruited for the study. For each patient, PET/CT and T1-weighted contrast MRI scans were first registered to the planning CT using deformable and rigid registration, respectively, to resample the PET and magnetic resonance (MR) images to the planning CT space. A binary mask was manually defined to identify the tumor area. The resampled PET and MR images, the planning CT image, and the binary mask were fed into the automatic segmentation algorithm for target delineation. The algorithm was based on a multichannel Gaussian mixture model and solved using an expectation–maximization algorithm with Markov random fields. To evaluate the algorithm, we compared the multichannel autosegmentation with an autosegmentation method using only PET images. The physician-defined gross tumor volume (GTV) was used as the “ground truth” for quantitative evaluation. Results: The median multichannel segmented GTV of the primary tumor was 15.7 cm{sup 3} (range, 6.6–44.3 cm{sup 3}), while the PET segmented GTV was 10.2 cm{sup 3} (range, 2.8–45.1 cm{sup 3}). The median physician-defined GTV was 22.1 cm{sup 3} (range, 4.2–38.4 cm{sup 3}). The median difference between the multichannel segmented and physician-defined GTVs was −10.7%, not showing a statistically significant difference (p-value = 0.43). However, the median difference between the PET segmented and physician-defined GTVs was −19.2%, showing a statistically significant difference (p-value =0.0037). The median Dice similarity coefficient between the multichannel segmented and physician-defined GTVs was 0.75 (range, 0.55–0.84), and the median sensitivity and positive predictive value between them were 0.76 and 0.81, respectively. Conclusions: The authors developed an automated multimodality segmentation algorithm for tumor volume delineation and validated this algorithm for head and neck cancer radiotherapy. The multichannel segmented GTV agreed well with the physician-defined GTV. The authors expect that their algorithm will improve the accuracy and consistency in target definition for radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP4-03: Cone Beam X-Ray Luminescence Computed Tomography Based On Generalized Gaussian Markov Random Field

Purpose: Cone beam X-ray luminescence computed tomography (CB-XLCT), which aims to achieve molecular and functional imaging by X-rays, has recently been proposed as a new imaging modality. However, the inverse problem of CB-XLCT is seriously ill-conditioned, hindering us to achieve good image quality. In this work, a novel reconstruction method based on Bayesian theory is proposed to tackle this problem Methods: Bayesian theory provides a natural framework for utilizing various kinds of available prior information to improve the reconstruction image quality. A generalized Gaussian Markov random field (GGMRF) model is proposed here to construct the prior model of the Bayesian theory. The most important feature of GGMRF model is the adjustable shape parameter p, which can be continuously adjusted from 1 to 2. The reconstruction image tends to have more edge-preserving property when p is slide to 1, while having more noise tolerance property when p is slide to 2, just like the behavior of L1 and L2 regularization methods, respectively. The proposed method provides a flexible regularization framework to adapt to a wide range of applications. Results: Numerical simulations were implemented to test the performance of the proposed method. The Digimouse atlas were employed to construct a three-dimensional mouse model, and two small cylinders were placed inside to serve as the targets. Reconstruction results show that the proposed method tends to obtain better spatial resolution with a smaller shape parameter, while better signal-to-noise image with a larger shape parameter. Quantitative indexes, contrast-to-noise ratio (CNR) and full-width at half-maximum (FWHM), were used to assess the performance of the proposed method, and confirmed its effectiveness in CB-XLCT reconstruction. Conclusion: A novel reconstruction method for CB-XLCT is proposed based on GGMRF model, which enables an adjustable performance tradeoff between L1 and L2 regularization methods. Numerical simulations were conducted to demonstrate its performance.

60 APPLIED LIFE SCIENCES↗

Development of Dose-Volume Relation Model for Gamma Knife Surgery of Non-Skull Base Intracranial Meningiomas

Purpose: To provide a dose-volume relationship for gamma knife surgery (GKS) of non-skull base intracranial meningiomas. Methods and Materials: The radiologic outcomes of GKS of 82 imaging-defined benign meningiomas located at non-skull base areas were analyzed. A total of 80 patients were included and all underwent treatment with GKS as the first and the only treatment modality. The mean patient age was 55.0 years (range, 26-78) and the mean tumor volume was 5.6 cm{sup 3} (range, 0.5-16.8). On average, 14.6 Gy (range, 10-20) was applied to the 50% isodose surface. The binary logistic regression method was applied to find prognostic factors of signal change (SC) on T{sub 2}-weighted magnetic resonance imaging after GKS. Results: The actuarial tumor control rate was 91.6% at 5 years. A total of 29 lesions (35.4%) showed newly developed or aggravated SCs. The volume irradiated {>=}14 Gy was the only statistically significant (p < .01) prognostic factor of SC. A dose-volume relation model obtained from the cases without SC estimated a 12.2% SC probability. Conclusion: This model can be used in GKS to treat small- to medium-size (<9.2 cm{sup 3}) non-skull base meningiomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Morphotype-resolved characterization of microalgal communities in a nutrient recovery process with ARTiMiS flow imaging microscopy

Microalgae-driven nutrient recovery represents a promising technology for phosphorus removal from wastewater while simultaneously generating biomass that can be valorized to offset treatment costs. As full-scale processes come online, system parameters including biomass composition must be carefully monitored to optimize performance and prevent culture crashes. In this study, flow imaging microscopy (FIM) was leveraged to characterize microalgal community composition in near real-time at a full-scale municipal wastewater treatment plant (WWTP) in Wisconsin, USA, and population and morphotype dynamics were examined to identify relationships between water chemistry, biomass composition, and system performance. Two FIM technologies, FlowCam and ARTiMiS, were evaluated as monitoring tools. ARTiMiS provided a more accurate estimate of total system biomass, and estimates derived from particle area as a proxy for biovolume yielded better approximations than particle counts. Deep learning classification models trained on annotated image libraries demonstrated equivalent performance between FlowCam and ARTiMiS, and convolutional neural network (CNN) classifiers proved significantly more accurate when compared to feature table-based dense neural network (DNN) models. Across a two-year study period, Scenedesmus spp. appeared most important for phosphorus removal, and were negatively impacted by elevated temperatures and increase in nitrite/nitrate concentrations. Chlorella and Monoraphidium also played an important role in phosphorus removal. For both Scenedesmus and Chlorella, smaller morphological types were more often associated with better system performance, whereas larger morphotypes likely associated with stress response(s) correlated with poor phosphorus recovery rates. Furthermore, these results demonstrate the potential of FIM as a critical technology for high-resolution characterization of industrial microalgal processes.

59 BASIC BIOLOGICAL SCIENCES↗

TH-A-18C-02: An Electrostatic Model for Assessment of Joint Space Morphology in Cone-Beam CT

Purpose: High-resolution cone-beam CT (CBCT) of the extremities presents a potentially valuable basis for image-based biomarkers of arthritis, trauma, and risk of injury. We present a new method for 3D joint space analysis that exploits the high isotropic spatial resolution of CBCT and is sensitive to small changes in disease-related morphology. Methods: The approach uses an “electrostatic” model in which joint surfaces (e.g., distal femur and proximal tibia) are labeled as charge densities between which the electric field is solved by approximation to the Laplace equation. The method yields a unique solution determined by the field lines across the “capacitor” and is hypothesized to be more sensitive than conventional (Sharp) scores and immune to degeneracies that limit simple distance-along-axis or closest-point analysis. The algorithm was validated in CBCT phantom images and applied in two clinical scenarios: osteoarthritis (OA, change in loadbearing tibiofemoral joint space); and assessment of injury risk (correlation of 3D joint space to tibial slope). Results: Joint space maps computed from the electrostatic model were accurate to within the voxel size (0.26 mm). The method highlighted subtle regions of morphological change that would likely be missed by conventional scalar metrics. Regions of subtle cartilage erosion were well quantified, and the method confidently discriminated OA and non-OA cohorts. 3D joint space maps correlated well with tibial slope and provide a new basis for principal component analysis of loadbearing injury risk. Runtime was less than 5 min (235×235×121 voxel subvolume in Matlab). Conclusion: A new method for joint space assessment was reported as a possible image-based biomarker of subtle articular change. The algorithm yields accurate quantitation of the joint in a manner that is robust against operator and patient setup variation. The method shows promising initial results in ongoing trials of CBCT in osteoarthritis, rheumatoid arthritis, and injury risk assessment. Research supported by R01 and R21 grants from the National Institutes of Health, academic-industry partnership with Carestream Health, and a grant from the US Army Natick Soldier Research, Development and Engineering Center.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charged-cell periodic DFT simulations via an impurity model based on density embedding: Application to the ionization potential of liquid water

Calculations of charged systems in periodic boundary conditions (PBC) are problematic because there are spurious interactions between the charges in different periodic images that can affect the physical picture. In addition, the intuitive limit of Coulomb interactions decaying to zero as the interacting charges are placed at infinite separation no longer applies, and for example total energies become undefined. Leveraging subsystem density functional theory (also known as density embedding) we define an impurity model that embeds a finite neutral or charged subsystem within an extended (infinite) surrounding subsystem. The combination of the impurity model and a consistent choice of the Coulomb reference provides us with an algorithm for evaluating the ionization potential (IP) in extended systems. Additionally, we demonstrate our approach in a pilot calculation of the IP of liquid water, based on a configuration from a prior ab initio molecular dynamics (AIMD) simulation of liquid water (Genova et al., J. Chem. Phys. 2016, 144, 234105). The calculations with the impurity model capture the broadening on the ionization energies introduced by the interactions between the water molecules. Furthermore, the calculated average IP value (10.5 eV) compare favorably to experiments (9.9-10.06 eV) and very recent simulations based on the GW approximation (10.55 eV), while at the same time outperforming density embedding calculations carried out with a naïve handling of the electrostatic interactions (about 7 eV).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗