Search NASA⌕ Search

SEARCH · Search NASA

Results for “image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Effective versus ion thermal temperatures in the Weizmann Ne Z-pinch: Modeling and stagnation physics

The difference between the ion thermal and effective temperatures is investigated through simulations of the Ne gas puff z-pinch reported by Kroupp et al. [Phys. Rev. Lett. 107, 105001 (2011)]. Calculations are performed using a 2D, radiation-magnetohydrodynamic code with Tabular Collisional-Radiative Equilibrium, namely Mach2-TCRE [Thornhill et al., Phys. Plasmas 8, 3480 (2001)]. The extensive data set of imaging and K-shell spectroscopy from the experiments provides a challenging validation test for z-pinch simulations. Synthetic visible images of the implosion phase match the observed large scale structure if the breakdown occurs at the density corresponding to the Paschen minimum. At the beginning of stagnation (−4 ns), computed plasma conditions change rapidly showing a rising electron density and a peak in the ion thermal temperature of ∼1.8 keV. This is larger than the ion thermal temperature (<400 eV) inferred from the experiment. By the time of peak K-shell power (0 ns), the calculated electron density is similar to the data and the electron and ion thermal temperatures are equilibrated, as is observed. Effective ion temperatures are obtained from calculated emission line widths accounting for thermal broadening and Doppler velocity shifts. The observed, large effective ion temperatures (∼4 keV) early in the stagnation of this Ne pinch can be explained solely as a combination of compressional ion heating and steep radial velocity gradients near the axis. Approximations in the modeling are discussed in regard to the higher ion thermal temperature and lower electron density early in the stagnation compared to the experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simple partitions of a hyperbolic plane of positive curvature

We construct special monohedral isotropic partitions with symmetries of the hyperbolic plane H of positive curvature with a simple 4-contour as a cell. An analogue of mosaic in these partitions called a tiling is introduced. Also we consider some fractal tilings. The existence of band tilings in each homological series with code (m, n) is proved. Bibliography: 14 titles.

97 MATHEMATICS AND COMPUTING↗

ULTRAVIOLET RADIATIVE TRANSFER MODELING OF NEARBY GALAXIES WITH EXTRAPLANAR DUSTS

In order to examine their relation to the host galaxy, the extraplanar dusts of six nearby galaxies are modeled, employing a three-dimensional Monte Carlo radiative transfer code. The targets are from the highly inclined galaxies that show dust-scattered ultraviolet halos, and the archival Galaxy Evolution Explorer FUV band images were fitted with the model. The observed images are generally well-reproduced by two dust layers and one light source layer, whose vertical and radial distributions have exponential profiles. We obtained several important physical parameters, such as star formation rate (SFR{sub UV}), face-on optical depth, and scale-heights. Three galaxies (NGC 891, NGC 3628, and UGC 11794) show clear evidence for the existence of an extraplanar dust layer. However, it is found that the remaining three targets (IC 5249, NGC 24, and NGC 4173) do not necessarily need a thick dust disk to model the ultraviolet (UV) halo, because its contribution is too small and the UV halo may be caused by the wing part of the GALEX point spread function. This indicates that the galaxy samples reported to have UV halos may be contaminated by galaxies with negligible extraplanar (halo) dust. The galaxies showing evidence of an extraplanar dust layer fall within a narrow range on the scatter plots between physical parameters such as SFR{sub UV} and extraplanar dust mass. Several mechanisms that could possibly produce the extraplanar dust are discussed. We also found a hint that the extraplanar dust scale-height might not be much different from the polycyclic aromatic hydrocarbon emission characteristic height.

79 ASTRONOMY AND ASTROPHYSICS↗

Machine Learning Benchmarks for the Classification of Equivalent Circuit Models from Electrochemical Impedance Spectra

Analysis of Electrochemical Impedance Spectroscopy (EIS) data for electrochemical systems often consists of defining an Equivalent Circuit Model (ECM) using expert knowledge and then optimizing the model parameters to deconvolute various resistance, capacitive, inductive, or diffusion responses. For small data sets, this procedure can be conducted manually; however, it is not feasible to manually define a proper ECM for extensive data sets with a wide range of EIS responses. Automatic identification of an ECM would substantially accelerate the analysis of large sets of EIS data. We showcase machine learning methods to classify the ECMs of 9,300 impedance spectra provided by QuantumScape for the BatteryDEV hackathon. The best-performing approach is a gradient-boosted tree model utilizing a library to automatically generate features, followed by a random forest model using the raw spectral data. A convolutional neural network using boolean images of Nyquist representations is presented as an alternative, although it achieves a lower accuracy. We publish the data and open source the associated code. The approaches described in this article can serve as benchmarks for further studies. A key remaining challenge is the identifiability of the labels, underlined by the model performances and the comparison of misclassified spectra.

25 ENERGY STORAGE↗

Data Visualization: Augmented Reality

In recent years, there has been an increasing interest in developing new technologies for automated characterization and visualization of condition monitoring data. Augmented Reality (AR) is a technology that is being developed to improve such data visualization. Augmented reality has been defined as a technology that merges virtual and physical components in real-time, and in three dimensions. Wearable, commercially-available AR devices allow onsite engineers and technicians to perform inspection tasks with significantly more available information such as comparisons of past and present sensor and imager data, onsite data analysis and result displays, and various forms of metadata including technical drawings, previous inspection reports and maintenance histories, operation manuals, codes and standards, and holograms representing data analysis results superimposed onto the in situ monitored system.

42 ENGINEERING↗

Numerical modeling of the early light curves of type IIP supernovae

The early rise of Type IIP supernovae (SN IIP) provides important information for constraining the properties of their progenitors. This can, in turn, be compared to pre-explosion imaging constraints and stellar models to develop a more complete picture of how massive stars evolve and end their lives. Using the SuperNova Explosion Code (SNEC), we model the first 40 days of SNe IIP to better understand what constraints can be derived from their early light curves. We use two sets of red supergiant (RSG) progenitor models with zero-age main sequence masses in the range between 9 M{sub ⊙} and 20 M{sub ⊙}. We find that the early properties of the light curve depend most sensitively on the radius of the progenitor, and thus provide a relation between the g-band rise time and the radius at the time of explosion. This relation will be useful for deriving constraints on progenitors from future observations, especially in cases where detailed modeling of the entire rise is not practical. When comparing to observed rise times, the radii we find are a factor of a few larger than previous semi-analytic derivations and are generally in better agreement with what is found with current stellar evolution calculations as well as direct observations of RSGs.

79 ASTRONOMY AND ASTROPHYSICS↗

The Anatomy of an Unusual Edge-on Protoplanetary Disk. I. Dust Settling in a Cold Disk

As the earliest stage of planet formation, massive, optically thick, and gas-rich protoplanetary disks provide key insights into the physics of star and planet formation. When viewed edge-on, high-resolution images offer a unique opportunity to study both the radial and vertical structures of these disks and relate this to vertical settling, radial drift, grain growth, and changes in the midplane temperatures. In this work, we present multi-epoch Hubble Space Telescope and Keck scattered light images, and an Atacama Large Millimeter/submillimeter Array 1.3 mm continuum map for the remarkably flat edge-on protoplanetary disk SSTC2DJ163131.2–242627, a young solar-type star in ρ Ophiuchus. We model the 0.8 μm and 1.3 mm images in separate Markov Chain Monte Carlo (MCMC) runs to investigate the geometry and dust properties of the disk using the MCFOST radiative transfer code. In scattered light, we are sensitive to the smaller dust grains in the surface layers of the disk, while the submillimeter dust continuum observations probe larger grains closer to the disk midplane. An MCMC run combining both data sets using a covariance-based log-likelihood estimation was marginally successful, implying insufficient complexity in our disk model. The disk is well characterized by a flared disk model with an exponentially tapered outer edge viewed nearly edge-on, though some degree of dust settling is required to reproduce the vertically thin profile and lack of apparent flaring. A colder than expected disk midplane, evidence for dust settling, and residual radial substructures all point to a more complex radial density profile to be probed with future, higher-resolution observations.

47 OTHER INSTRUMENTATION↗

Phase and Radial Motion in a Transverse Electric Quadrupole

Parmteq comprises a group of codes (PARMTEQ, RFQUICK, CURLI and PARI) that are used to design high-performance radio-frequency quadrupole (RFQ) linacs. PARMTEQ is an acronym for "Phase and Radial Motion in a Transverse Electric Quadrupole". These codes are necessary to design the RFQ vane profile and analyze the beam performance including the effects of higher order multipole field components and image charges. Multi-particle simulations are supported in Version 3.

Billen, James↗

Phase and Radial Motion in a Transverse Electric Quadrupole - Manufacturing

ParmteqM comprises a group of codes (PARMTEQ, RFQUICK, CURLI, PARI, PARMTEQM, READVG and VANES) that are used to design high-performance radio-frequency quadrupole (RFQ) linacs. PARMTEQ is an acronym for "Phase and Radial Motion in a Transverse Electric Quadrupole". These codes are necessary to design the RFQ vane profile and analyze the beam performance including the effects of higher order multipole field components and image charges. Multi-particle simulations are supported in Version 3. PARMTEQM, VANES and READVG specifically provide manufacturing support to generate CNC machining instructions for the fabrication of vane profiles.

Billen, James↗

Analytic reconstruction algorithms for triple-source CT with horizontal data truncation

Purpose: This paper explores a triple-source imaging method with horizontal data truncation to enlarge the field of view (FOV) for big objects. Methods: The study is conducted by using theoretical analysis, mathematical deduction, and numerical simulations. The proposed algorithms are implemented in c + + and MATLAB. While the basic platform is constructed in MATLAB, the computationally intensive segments are coded in c + +, which are linked via a MEX interface. Results: A triple-source circular scanning configuration with horizontal data truncation is developed, where three pairs of x-ray sources and detectors are unevenly distributed on the same circle to cover the whole imaging object. For this triple-source configuration, a fan-beam filtered backprojection-type algorithm is derived for truncated full-scan projections without data rebinning. The algorithm is also extended for horizontally truncated half-scan projections and cone-beam projections in a Feldkamp-type framework. Using their method, the FOV is enlarged twofold to threefold to scan bigger objects with high speed and quality. The numerical simulation results confirm the correctness and effectiveness of the developed algorithms. Conclusions: The triple-source scanning configuration with horizontal data truncation cannot only keep most of the advantages of a traditional multisource system but also cover a larger FOV for big imaging objects. In addition, because the filtering is shift-invariant, the proposed algorithms are very fast and easily parallelized on graphic processing units.

60 APPLIED LIFE SCIENCES↗

SU-F-T-229: A Novel Method for EPID-Based In-Vivo Exit Dose Verification for Intensity Modulated Radiotherapy

Purpose: Electronic portal imaging device (EPID) can be used to acquire a two-dimensional exit dose distribution during treatment delivery, thus allowing the in-vivo verification of the dose delivery through a comparison of measured portal images to predicted portal dose images (PDI). The aim of this study was to present a novel method to easily and accurately predict PDI, and to establish an EPID-based in-vivo dose verification method during IMRT treatments. Methods: We developed a model to determine the predicted portal dose at the same plane of the EPID detector location. The Varian EPID (aS1000) positions at 150cm source-to-detector-distance (SDD), and can be used to acquire in-vivo exit dose using Portal Dosimetry (PD) function. Our model was generated to make an equivalent water thickness represent the buildup plate of EPID. The exit dose at extend SDD plane with patient CT data in the beam can be calculated as the predicted PDI in the treatment planning system (TPS). After that, the PDI was converted to the fluence at SDD of 150cm using the inverse square law coded in MATLAB. Five head-and-neck and prostate IMRT patient plans contain 32 fields were investigated to evaluate the feasibility of this new method. The measured EPID image was compared with PDI using the gamma analysis. Results: The average results for cumulative dose comparison were 81.9% and 91.6% for 3%, 3mm and 4%, 4mm gamma criteria, respectively. Results indicate that the patient transit dosimetry predicted algorithm compares well with EPID measured PD doses for test situations. Conclusion: Our new method can be used as an easy and feasible tool for online EPID-based in-vivo dose delivery verification for IMRT treatments. It can be implemented for fast detecting those obvious treatment delivery errors for individual field and patient quality assurance.

60 APPLIED LIFE SCIENCES↗

Multistep inversion workflow for 3D long-offset damped elastic waves in the Fourier domain

We present a new workflow for imaging damped three-dimensional elastic wavefields in the Fourier domain. The workflow employs a multiscale imaging approach, in which offset lengths are laddered, where frequency content and damping of the data are changed cyclically. Thus, the inversion process is launched using short-offset and low-frequency data to recover the long spatial wavelength of the image at a shallow depth. Increasing frequency and offset length leads to the recovery of the fine-scale features of the model at greater depths. For the fixed offset, we employ (in the imaging process) a few discrete frequencies with a set of Laplace damping parameters. The forward problem is solved with a finite-difference frequency-domain method based on a massively parallel iterative solver. The inversion code is based upon the solution of a least squares optimisation problem and is solved using a nonlinear gradient method. It is fully parallelised for distributed memory computational platforms. Our full-waveform inversion workflow is applied to the 3D Marmousi-2 and SEG/EAGE Salt models with long-offset data. The maximum inverted frequencies are 6 Hz for the Marmousi model and 2 Hz for the SEG/EAGE Salt model. The detailed structures are imaged successfully up to the depth approximately equal to one-third of the maximum offset length at a resolution consistent with the inverted frequencies.

3D full waveform inversion↗

Efficient Workflows for Curation of Heterogeneous Data Supporting Modeling of U-Nb Alloy Aging

These are slides from a presentation summarizing a graduate research associate's summer project. The following topics are covered in these slides: data challenges in materials, aging in U-Nb Alloys, Building an Aging Model, Different Phase Trans. in U-Nb, the Challenge, Storing Materials Data, Example Data Source, Organizing Data: What is a Schema?, What does a "XML Schema" look like?, Our Data Schema: Nice and Simple, Storing Data: Materials Data Curation System (MDCS), Problem with MDCS: Slow Data Entry, Getting Literature into MDCS, Staging Data in Excel Document, Final Result: MDCS Records, Analyzing Image Data, Process for Making TTT Diagram, Bottleneck Number 1: Image Analysis, Fitting a TTP Boundary, Fitting a TTP Curve: Comparable Results, How Does it Compare to Our Data?, Image Analysis Workflow, Curating Hardness Records, Hardness Data: Two Key Decisions, Before Peak Age? - Automation, Interactive Viz, Which Transformation?, Microstructure-Informed Model, Tracking the Entire Process, General Problem with Property Models, Pinyon: Toolkit for Managing Model Creation, Tracking Individual Decisions, Jupyter: Docs and Code in One File, Hardness Analysis Workflow, Workflow for Aging Models, and conclusions.

36 MATERIALS SCIENCE↗

Reconstruction of NSTX midplane neutral density profiles from visible imaging data

In this report the experimental determination of neutral densities in tokamak plasmas from line radiation is only accurate in the narrow region in which both the excitation rate and neutral density are significant. We describe an alternative procedure using the DEGAS 2 Monte Carlo neutral transport code to invert light emission data obtained from a tangentially viewing camera, yielding absolute radial profiles of deuterium atoms and molecules at midplane. That the neutral source in these simulations can be adequately characterized as a uniform flux at the vacuum vessel wall is demonstrated by the similarity of the shapes of the simulated and observed brightness profiles. A second test is obtained by comparing the resulting neutral pressures at the vessel walls with data from midplane micro-ion gauges. We also show that the simulated camera image is insensitive to variations in the spatial distribution of the neutral source.

(PSI-21) NSTX DEGAS↗

SU-E-J-104: Single Photon Image From PET with Insertable SPECT Collimator for Boron Neutron Capture Therapy: A Feasibility Study

Purpose: The aim of our proposed system is to confirm the feasibility of extraction of two types of images from one positron emission tomography (PET) module with an insertable collimator for brain tumor treatment during the BNCT. Methods: Data from the PET module, neutron source, and collimator was entered in the Monte Carlo n-particle extended (MCNPX) source code. The coincidence events were first compiled on the PET detector, and then, the events of the prompt gamma ray were collected after neutron emission by using a single photon emission computed tomography (SPECT) collimator on the PET. The obtaining of full width at half maximum (FWHM) values from the energy spectrum was performed to collect effective events for reconstructed image. In order to evaluate the images easily, five boron regions in a brain phantom were used. The image profiles were extracted from the region of interest (ROI) of a phantom. The image was reconstructed using the ordered subsets expectation maximization (OSEM) reconstruction algorithm. The image profiles and the receiver operating characteristic (ROC) curve were compiled for quantitative analysis from the two kinds of reconstructed image. Results: The prompt gamma ray energy peak of 478 keV appeared in the energy spectrum with a FWHM of 41 keV (6.4%). On the basis of the ROC curve in Region A to Region E, the differences in the area under the curve (AUC) of the PET and SPECT images were found to be 10.2%, 11.7%, 8.2% (center, Region C), 12.6%, and 10.5%, respectively. Conclusion: We attempted to acquire the PET and SPECT images simultaneously using only PET without an additional isotope. Single photon images were acquired using an insertable collimator on a PET detector. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, Information and Communication Technologies (ICT) and Future Planning (MSIP)(Grant No.2009 00420) and the Radiation Technology R and D program (Grant No.2013M2A2A7043498), Republic of Korea.

07 ISOTOPE AND RADIATION SOURCES↗

Rayleigh-Taylor Growth Measurements in the Acceleration Phase of Spherical Implosions on OMEGA

The Rayleigh-Taylor (RT) growth of 3D broadband nonuniformities was measured using x-ray radiography in spherical plastic shells accelerated by laser light at an intensity of ~2 x 10^14 W/cm^2. The 20- and 24-um-thick spherical shells were imploded with 54 beams on the OMEGA laser system. The shells contained diagnostic openings for backlighter x rays used to image shell modulations. The measured shell trajectories and modulation RT growth were in fair agreement with 2D hydro simulations during the acceleration phase of the implosions with convergence ratios of up to ~2:2. Since the ignition designs rely on these simulations, improvements in the numerical codes will be implemented to achieve better agreement with experiments.

Smalyuk, V A↗

Water chemistry in flume channel and hyporheic zone (i.e., porewater) associated with: “Rethinking Aerobic Respiration in the Hyporheic Zone Under Variation in Carbon and Nitrogen Stoichiometry”

Dissolved oxygen (DO), total organic carbon (TOC), total nitrogen (TN), molecular data for organic matter, and biochemical reactions for surface water and porewater (i.e., hyporheic zone) collected from a water recirculating flume located at the University of Texas, Austin. The flume contained real river water from Lower Colorado River(Austin, TX) and clean sand. Hyporheic exchange in the flume was induced through The study aims to understand relationships between aerobic metabolism of organic matter and molecular characteristics of organic matter, such as thermodynamic signature and nitrogen content, through the extent of the hyporheic zone at 10 cm- resolution, and through time. During the experiment, organic matter (dry leaves) was added to the flume and removed after 24 hours. The water samples were collected before the addition of leaves, at the time of removal of leaves, and at hour 72. The water samples were analyzed using ultrahigh resolution Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) and total organic carbon (TOC) and total nitrogen (TN) analysis. Dissolved oxygen content throughout the surface water and the hyporheic zone of the flume was measured with a large planar optode. This data package is associated with the publication ’ Rethinking Aerobic Respiration in the Hyporheic Zone Under Variation in Carbon and Nitrogen Stoichiometry’ published in Environmental Science and Technology (Turețcaia et al., 2023 https://doi.org/10.1021/acs.est.3c04765). The dataset is comprised of five folders (1) Diss_O2_pic, (2) input_files (3) output_files; (4) python_code; and (5) R_code . Diss_O2_pic contains siximages of dissolved oxygen distribution in a bedform at hours 0, 24, and 72 of the experiment conducted in a large recirculation flume. Images are in separate R and G channels (i.e., RGB). The input_files contains (1) a csv file with FTICR peaks identified within each sample, (2) a csv file with molecular information pertinent to FTICR data with Gibbs free energy calculations adjusted for environmental temperature, (3) a csv file containing concentrations of non-purgeable organic carbon measured throughout the experiment , (4) a csv file containing concentrations of total nitrogen measured throughout the experiment, (5) a csv file containing total biochemical reactions (i.e., transformations) identified in the dataset, (6) a csv containing transformation profiles, and (7) a csv file containing transformations with formulas, and (8) a jpg file with schematic representation of locations for sample collection. The output_files contains (1) and xlsx file containing percent biochemical reactions containing nitrogen identified across all 39 sample, (2) a csv file of merged FTICR data and molecular information files, (3) a csv files containing average Gibbs free energy within sampling domains and at each sampling location, (4) a csv file with average concentrations of dissolved oxygen across sampling locations at hour 0, (5) a csv file with average concentrations of dissolved oxygen across sampling locations at hour 24, (6) a csv file with average concentrations of dissolved oxygen across sampling locations at hour 72, (7) a csv file with percent chemical classes identified across sampling locations at hour 0, (8) a csv file with percent chemical classes identified across sampling locations at hour 24, (9) a csv file with percent chemical classes identified across sampling locations at hour 72, and (10) a csv file containing percent nitrogen containing biochemical reactions identified across sampling locations at hours 0, 24, and 72. The python_code contains seven ipynb files which are Jupyter Notebooks used for data analysis and figures generation. The R_code contains 3 R files with R code used for data analysis and figures generation. This data package contains the processed data used in the associated manuscript. This data has not been previously published.

54 ENVIRONMENTAL SCIENCES↗

Current advances on Talbot–Lau x-ray imaging diagnostics for high energy density experiments (invited)

Talbot–Lau x-ray interferometry is a refraction-based diagnostic that can map electron density gradients through phase-contrast methods. The Talbot–Lau x-ray deflectometry (TXD) diagnostics have been deployed in several high energy density experiments. To improve diagnostic performance, a monochromatic TXD was implemented on the Multi-Tera Watt (MTW) laser using 8 keV multilayer mirrors (Δθ/θ = 4.5%-5.6%). Copper foil and wire targets were irradiated at 10 14 –10 15 W/cm 2 . Laser pulse length (~10 to 80 ps) and backlighter target configurations were explored in the context of Moiré fringe contrast and spatial resolution. Foil and wire targets delivered increased contrast <30%. The best spatial resolution (<6 μm) was measured for foils irradiated 80° from the surface. Further TXD diagnostic capability enhancement was achieved through the development of advanced data postprocessing tools. The Talbot Interferometry Analysis (TIA) code enabled x-ray refraction measurements from the MTW monochromatic TXD. Additionally, phase, attenuation, and dark-field maps of an ablating x-pinch load were retrieved through TXD. The images show a dense wire core of ~60 μm diameter surrounded by low-density material of ~40 μm thickness with an outer diameter ratio of ~2.3. Attenuation at 8 keV was measured at ~20% for the dense core and ~10% for the low-density material. Instrumental and experimental limitations for monochromatic TXD diagnostics are presented. Enhanced postprocessing capabilities enabled by TIA are demonstrated in the context of high-intensity laser and pulsed power experimental data analysis. Significant advances in TXD diagnostic capabilities are presented. Furthermore, these results inform future diagnostic technique upgrades that will improve the accuracy of plasma characterization through TXD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗