Search NASA⌕ Search

SEARCH · Search NASA

Results for “level sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Wearable Biosensor Monitor to Support Autonomous Crew Health and Readiness to Perform

For future human exploration missions, NASA needs a health monitoring system composed of hardware that is compact, fully interoperable with an integrated data management system, and requires minimal consumables. Such a system will be achieved through the integration of small, easy to use biomedical sensors that will have the ability to measure, store and transmit physiological parameters during operational and ambulatory activity. Since 2012, the Canadian Space Agency (CSA) has been active in funding the development of wearable biomonitoring sensors. The Astroskin is the first prototype and consists of a shirt-based garment and headband with embedded sensors, and associated software and technology that measure vital signs, sleep quality and activity level of the wearer. NASA and CSA have been collaborating since 2014 to test and validate this system in a lab environment at Ames Research Center and more recently in the Human Exploration Research Analog (HERA) located at Johnson Spaceflight Center. Specific objectives of the HERA study were: 1) to assess the performance of the Astroskin biosensor system for long-term health monitoring (24-hours) capabilities and during exercise as a measure of crew fitness; 2) to obtain crew feedback on comfort and usability of the Astroskin system; 3) to demonstrate performance of Bluetooth communication during real-time transmission and for verification of data in this environment; and 4) to obtain baseline data for further development of algorithms and tools that facilitate decision support for diagnosing and monitoring of a sick or injured crewmember. HERA Campaign 3 included four missions (each 30-days in duration) with four crewmembers assigned to each mission. A total of 9 men and 7 women participated in the Astroskin evaluation that included continuous physiological monitoring (24-hours) on mission days MD-11, MD1 (high workload), MD15 (low workload), MD19, MD29, and MD+7. Mission days 19 and 29 also included 30 minutes of sub-maximal exercise on a cycle ergometer. Following each 24-hour monitoring session crew physiological data were downloaded to laptops and each crewmember completed a 28 question survey on their experiences with the Astroskin hardware and software. This presentation will focus on lessons learned from the HERA missions. Specifically it will address Astroskin system performance in terms of data loss and data quality (no comparison to lab standard devices), wireless communication with the onboard mobile device, crew usability and comfort, and future development of a next generation biomonitoring system.

crew fitness↗

LANDSAT 9 Thermal Infrared Sensor 2 Spectral Response Test: Updates and Perspective

The Thermal Infrared Sensor 2 (TIRS-2) pre-launch spectral characterization at telescope and detector subsystem level provided a strong indication that the spectral response requirements will be met. Confidence in the validity of these results was strengthened through comparison to component-level measurements. This work reviews the modifications to the test setup to reduce spectral response uncertainties further in preparation for instrument-level testing. We developed a methodology to improve alignment repeatability of the upgraded system. Preliminary indications show that the spectral response will contribute a relatively small amount to the overall TIRS-2 radiometric uncertainty budget, which is expected to meet its radiometric requirements. Through spectral response testing, as part of a comprehensive pre-launch test program, TIRS-2 is expected to achieve the performance necessary for a variety of environmental applications.

spectral response↗

Landsat 9 TIRS-2 Spectral Response Test: Updates & Perspective

The Thermal Infrared Sensor 2 (TIRS-2) pre-launch spectral characterization at telescope and detector subsystem level provided a strong indication that the spectral response requirements will be met. Confidence in the validity of these results was strengthened through comparison to component-level measurements. This work reviews the modifications to the test setup to reduce spectral response uncertainties further in preparation for instrument-level testing. We developed a methodology to improve alignment repeatability of the upgraded system. Preliminary indications show that the spectral response will contribute a relatively small amount to the overall TIRS-2 radiometric uncertainty budget, which is expected to meet its radiometric requirements. Through spectral response testing, as part of a comprehensive pre-launch test program, TIRS-2 is expected to achieve the performance necessary for a variety of environmental applications.

Pearlman, Aaron↗

Leading University Students to the Edge of Space

For over 16 years, the Louisiana Space Grant Consortium (LaSPACE), the NASA Balloon Program Office (BPO), and the NASA Columbia Scientific Balloon Facility (CSBF) have collaborated in a series of high altitude balloon-based programs involving hands-on authentic learning experiences that expose university students and other participants to technical skills, teamwork dynamics, and effective communication methods. Such programs go beyond what is possible to achieve in a normal classroom and help prepare future engineers and scientists for a successful aerospace workforce career. In our collaborative effort, LaSPACE has focused on the program content and student mentoring while NASA BPO and CSBF provide balloon flight support and operations. The entry-level Louisiana Aerospace Catalyst Experiences for Students (LaACES) builds students’ skills in basic electronics, sensor interfacing, real-time programming, mechanical development, and project management. These skills are then applied to the design, development, fabrication, and flight of a small (∼500 gram) balloon payload. Finally, the payloads are flight-tested to an altitude of ∼30 km using a 2 kg latex sounding balloon. The LaACES program includes a set of lectures, activities, and Arduino Mega based electronic kits that are used for skill building and as a core control system for the student payload. The more advanced High Altitude Student Platform (HASP) is designed to carry ∼twelve 3 to 20 kg student payloads to an altitude of about 36 kilometers with flight durations of 10 to 20 hours using a ∼311,500 cubic meter, zero pressure balloon. HASP provides all student payloads with power, downlink telemetry, uplink commanding, and real-time HD video for instrument control and assessment during the flight. While originally developed for university students, these programs have been adapted to projects focused on high school teachers as well as affecting minorities underrepresented in aerospace related science and engineering fields. We are now in the process of adapting the LaACES materials to a pre-engineering curriculum for high school students as well as for widespread access over the internet. During this presentation, we will provide details of both the LaACES and HASP programs, how these programs have engaged participants from all demographic groups, and our current plans for continuing and expanding upon our success.

University↗

Predicted thermal response of a cryogenic fuel tank exposed to simulated aerodynamic heating profiles with different cryogens and fill levels

A two dimensional finite difference thermal model was developed to predict the effects of heating profile, fill level, and cryogen type prior to experimental testing the Generic Research Cryogenic Tank (GRCT). These numerical predictions will assist in defining test scenarios, sensor locations, and venting requirements for the GRCT experimental tests. Boiloff rates, tank-wall and fluid temperatures, and wall heat fluxes were determined for 20 computational test cases. The test cases spanned three discrete fill levels and three heating profiles for hydrogen and nitrogen.

Hanna, Gregory J.↗

A SiPM-based optical readout system for the EIC dual-radiator RICH

Silicon photomultipliers (SiPM) are candidates selected as the potential photodetector technology for the dual-radiator Ring-Imaging Cherenkov (dRICH) detector at the future Electron-Ion Collider (EIC). SiPM are cheap devices, highly efficient and insensitive to the high magnetic field at the expected location of the sensors in the experiment. Here, on the other hand, SiPM are not radiation tolerant. Despite the integrated radiation level is expected to be moderate it should be tested whether single photon-counting capabilities and the increase in dark count rate can be kept under control to maintain the optimal dRICH detector performance across the years. The current status of the research for the EIC dRICH application and the first results on studies performed on a sample of commercial and prototype SiPM sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributed Magnetic Field and Temperature Monitoring for Superconducting Radio Frequency Cavities

The overall objective of the proposed Phase I program was to design, construct and demonstrate a fiber optic sensing system capable of providing temperature and magnetic field measurements with an enhanced spatial resolution that can be implemented over a large surface area (cryomodules) to survey superconducting radio frequency cavities and magnets. A magnetic field sensor capable of detecting fluxes on the order of 1 μT is required to detect the distribution of trapped flux on the cavity surface. A unique distributed magnetic field sensor was successfully designed and constructed to demonstrate the detection of magnetic fluxes less than 500 nT. The sensor leveraged the ultra-high sensitivity of Sentek’s picoDAS to measure the magnetostriction induced vibrations in a commercially available Metglas 2605 SC ribbon that was in physical contact with sensing fiber. Static magnetic fields were detected by applying an alternating current a copper wire proximate to the Metglas 2605SC ribbon to create an AC bias magnetic field. In an alternative approach, an AC bias magnetic field was applied to a special magnetic field sensing fiber with Metglas 2605SC cladding successfully detect a magnetic field flux of a 3 μT. Exhaustive testing was performed to characterize the dependency of sensor response on the direction of the applied magnetic field. Although the special sensing fiber based magnetic field sensor did not exhibit an observable dependence on the direction of the magnetic field, the Metglas 2605SC ribbon sensor exhibited a clear directional dependence. A wide variety of polymer materials were evaluated to enhance the temperature response of an FBG based sensor at cryogenic temperatures. The processing and performance challenges provided the motivation to develop a new simple cryogenic temperature sensor that uses a commercially available fiber optic splice protector. The EVA hot melt tube that becomes adhered to the optical fiber and the polyolefin outer tube that shrinks upon heating in the fusion splicer heater provide the high thermal expansion coefficient necessary to impart a significant strain on the FBG when exposed to cryogenic temperatures. The temperature sensitivity (Δ𝜆𝐵𝑟𝑎𝑔𝑔~ 62 𝑝𝑝𝑚/℃) of the FBG-based sensor was on par with the best reported to date. The simple design, use of readily available cost-effective materials, and well-established processing techniques lends this approach to the creation of hundreds to thousands of temperature sensors on one single optical fiber length. The inherently small form factor also allows for co-location with the distributed magnetic field sensor. In preparation for field testing of the prototype sensing system at the Jefferson Labs in potential Phase II program, several different cable designs were evaluated to package the sensors. The preliminary successful demonstration of fully functional sensing cables provides the foundation for subsequent development efforts to advance the Technology Readiness Level of the technology. The technical feasibility of the proposed approach was successfully demonstrated in this Phase I effort.

43 PARTICLE ACCELERATORS↗

Synergistic Integration of Chemo-Resistive and SERS Sensing for Label-Free Multiplex Gas Detection

Practical sensing applications such as real-time safety alerts and clinical diagnoses require sensor devices to differentiate between various target molecules with high sensitivity and selectivity, yet conventional devices such as oxide-based chemo-resistive sensors and metal-based surface-enhanced Raman spectroscopy (SERS) sensors usually do not satisfy such requirements. In this report a label-free, chemo-resistive/SERS multimodal sensor based on a systematically assembled 3D cross-point multifunctional nanoarchitecture (3D-CMA), which has unusually strong enhancements in both “chemo-resistive” and “SERS” sensing characteristics is introduced. 3D-CMA combines several sensing mechanisms and sensing elements via 3D integration of semiconducting SnO 2 nanowire frameworks and dual-functioning Au metallic nanoparticles. It is shown that the multimodal sensor can successfully estimate mixed-gas compositions selectively and quantitatively at the sub-100 ppm level, even for mixtures of gaseous aromatic compounds (nitrobenzene and toluene) with very similar molecular structures. This is enabled by combined chemo-resistive and SERS multimodal sensing providing complementary information.

36 MATERIALS SCIENCE↗

Additively Manufactured IN718 Components with Wirelessly Powered and Interrogated Embedded Sensing

A methodology is described for embedding commercial-off-the-shelf sensors together with wireless communication and power circuit elements using direct laser metal sintered additively manufactured components. Physics based models of the additive manufacturing processes and sensor/wireless level performance models guided the design and embedment processes. A combination of cold spray deposition and laser engineered net shaping was used to fashion the transmitter/receiving elements and embed the sensors, thereby providing environmental protection and component robustness/survivability for harsh conditions. By design, this complement of analog and digital sensors were wirelessly powered and interrogated using a health and utilization monitoring system; enabling real-time, in situ prognostics and diagnostics.

embedded sensing↗

Sensor Integrated Pilot Mask for On-Board, Real-Time, Monitoring of Pilot Breathing Gas

A pilot's job is unique in the demands it places on the human body, and many conditions can seriously affect pilot performance, threatening mission completion and pilot safety. The gas in a flight mask contains key indicators of the pilot's physiological state, including oxygen inhaled and carbon dioxide exhaled, which can signal hypoxia, hyperoxia, hypocapnia, and hypercapnia. A fiber optic-based sensor system, integrated into the pilot mask, has been developed to monitor in real time, during flight, the pilot breathing gas levels. Monitoring the partial pressure of oxygen and carbon dioxide in the pilot mask supports real-time closed loop control of the on-board oxygen generation system, based on a direct reading of what the pilot is actually breathing. The pilot Mask Sensor (MASES) system incorporates luminescence sensors for pO2, pCO2, relative humidity, pressure, and temperature in a compact probe in the pilot mask; it is based on sensor technology developed for gas monitoring in space suit systems, in work supported by NASA under the Small Business Innovation Research program. Relevant requirements for the MASES system include sensor operation while wet, operation at reduced pressure, ability to withstand rapid decompression, operation in a pure oxygen atmosphere, low power consumption, a compact readout unit, and flexible miniature sensors; many of these requirements are shared with gas monitors in space suits. Data are presented from tests conducted with human subjects in an altitude chamber and in a centrifuge.

Delgado Alonso, Jesus↗

Attitude and vibration control of a large flexible space-based antenna

The problem of control systems synthesis is considered for controlling the rigid body attitude and elastic motion of a large deployable space based antenna. Two methods for control systems synthesis are considered. The first method utilizes the stability and robustness properties of the controller consisting of torque actuators and collocated attitude and rate sensors. The second method is based on the linear quadratic Gaussian (LQG) control theory. A combination of the two methods, which results in a two level hierarchical control system, is also briefly discussed. The performance of the controllers is analyzed by computing the variances of pointing errors, feed misalignment errors and surface contour errors in the presence of sensor and actuator noise.

Joshi, S. M.↗

Attitude and vibration control of a large flexible space-based antenna

Control systems synthesis is considered for controlling the rigid body attitude and elastic motion of a large deployable space-based antenna. Two methods for control systems synthesis are considered. The first method utilizes the stability and robustness properties of the controller consisting of torque actuators and collocated attitude and rate sensors. The second method is based on the linear-quadratic-Gaussian control theory. A combination of the two methods, which results in a two level hierarchical control system, is also briefly discussed. The performance of the controllers is analyzed by computing the variances of pointing errors, feed misalignment errors and surface contour errors in the presence of sensor and actuator noise.

Joshi, S. M.↗

Air Quality Forecasting at Sub-City Scale by Combining Models, Satellites, and Surface Measures

While there are a variety of sources for air quality information, no one source simultaneously allows for high accuracy, low bias, fine spatial resolution, wide spatial coverage, high temporal frequency, and the capability for near-term forecasting of air quality. Global models, like the NASA’s Goddard Earth Observing System -Composition Forecasting (GEOS-CF) model, provide global coverage and forecasting capabilities, but operate at relatively coarse spatial resolution and require ground-truthing with in-situ data. Polar-orbiting satellite data products, like those of the ESA TROPOspheric Monitoring Instrument (TROPOMI), provide higher-spatial-resolution remote sensing of atmospheric composition, but are limited by cloud cover and overpass times and report column-integrated quantities. Surface measurements, both from regulatory-grade monitors and low-cost networks, measure “nose-level” air quality, but may not represent concentration variability across large spatial domains, and (in the case of low-cost sensors) are subject to interference and biases. There exists a great potential to combine these diverse data sources together, using the strengths of some to offset the weaknesses of others to build a more comprehensive picture of air quality. This presentation will summarize results from ongoing efforts to produce such a combined forecast, with application case studies for surface-level Nitrogen Dioxide forecasting in several major US cities. Furthermore, we will examine the relative impacts and benefits of different data sources on the forecasting accuracy at different spatial and temporal scales. Finally, we will examine the potential for integrating low-cost sensors into such a system, both in terms of using these integrated air quality estimates as a baseline from which to calibrate networks of low-cost sensors in the field, and in terms of using dense networks of low-cost sensors to refine the spatial resolution of integrated air quality forecasts.

Air Quality↗

Application of Spectral Analysis Techniques in the Intercomparison of Aerosol Data: 1. an EOF Approach to the Spatial-Temporal Variability of Aerosol Optical Depth Using Multiple Remote Sensing Data Sets

Many remote sensing techniques and passive sensors have been developed to measure global aerosol properties. While instantaneous comparisons between pixel-level data often reveal quantitative differences, here we use Empirical Orthogonal Function (EOF) analysis, also known as Principal Component Analysis, to demonstrate that satellite-derived aerosol optical depth (AOD) data sets exhibit essentially the same spatial and temporal variability and are thus suitable for large-scale studies. Analysis results show that the first four EOF modes of AOD account for the bulk of the variance and agree well across the four data sets used in this study (i.e., Aqua MODIS, Terra MODIS, MISR, and SeaWiFS). Only SeaWiFS data over land have slightly different EOF patterns. Globally, the first two EOF modes show annual cycles and are mainly related to Sahara dust in the northern hemisphere and biomass burning in the southern hemisphere, respectively. After removing the mean seasonal cycle from the data, major aerosol sources, including biomass burning in South America and dust in West Africa, are revealed in the dominant modes due to the different interannual variability of aerosol emissions. The enhancement of biomass burning associated with El Niño over Indonesia and central South America is also captured with the EOF technique.

variability↗

Spatial Grid-Based Object Localization from A Single Passive Sensor: A Deep Learning-Integrated Approach

Ongoing efforts at NASA’s Langley Research Center have produced a single passive sensor system for detecting ground objects and pinpointing their real-world location to a desired level of precision. The Langley center serves as a test range for unmanned aerial systems (UAS) and real-time knowledge about the location of people on campus is needed to inform least-risk UAS flight operations. The proposed system provides this knowledge through a camera combined with a convolutional neural network and an algorithm that projects an imaginary grid of square cells from the ground plane onto the perspective view of the camera. The position of detected objects on the camera’s projected grid determines their location in the real-world. The imaginary grid is easily mapped to a universal coordinate system, such as longitude and latitude, to provide both relative and absolute positional information of the detected objects. This simple system is shown to be accurate and effective, with decisive advantages over alternative multi-sensor and active sensor approaches. Extensions to the system are described to allow adaptation to a variety of other use cases.

object localization↗

Measurement of free chlorine levels in water using potentiometric responses of biofilms and applications for monitoring and managing the quality of potable water

We report residual free chlorine is not monitored continuously at scale in drinking water distribution systems because existing real-time sensor technologies require frequent maintenance, cleaning, and calibration, which makes these products too costly to be used throughout a distribution system. As a result, current measurement approaches require manual sampling, which is not feasible for the consistent monitoring of free chlorine because chlorine concentrations vary significantly throughout pipeline distribution and over time and space. This research presents an alternative and cost-effective method of predicting free chlorine levels in drinking water using graphite electrodes coated with naturally grown microbial biofilms. This Microbial Potentiometric Sensor (MPS) array was installed in a Continuously Mixed Batch Reactor (CMBR), and drinking water containing variable free chlorine concentrations. The chlorine concentrations were introduced in a controlled manner, and the MPS signals were monitored over time. MPS signals were measured from the change in Open Circuit Potential (OCP) across the MPS array in real-time. An empirically derived relationship between the normalized change in OCP and free chlorine was established by fitting individual and average MPS data to a decaying exponential growth function in order to predict free chlorine levels. The results show that free chlorine can be predicted with reasonable accuracy, with model validation showing an average absolute error of ±0.09 ppm below 1.1 ppm and ±0.30 ppm between 1.1 and 2.7 ppm. However, the accuracy of predictions was reduced at higher free chlorine levels. The researchers conclude that MPS systems may benefit drinking water distribution systems by measuring free chlorine. These advantages of the MPS are especially pronounced in the developing world because this system is inexpensive and does not require routine maintenance or cleaning. The system relies on a naturally forming and regenerating biofilm and an inexpensive potentiometric meter to produce stable measurements.

54 ENVIRONMENTAL SCIENCES↗

Real-time measurements of endogenous CO production from vascular cells using an ultrasensitive laser sensor

Carbon monoxide (CO) has been implicated as a biological messenger molecule analogous to nitric oxide. A compact gas sensor based on a midinfrared laser absorption spectroscopy was developed for direct and real-time measurement of trace levels (in approximate pmol) of CO release by vascular cells. The midinfrared light is generated by difference frequency mixing of two nearinfrared lasers in a nonlinear optical crystal. A strong infrared absorption line of CO (4.61 microm) is chosen for convenient CO detection without interference from other gas species. The generation of CO from cultured vascular smooth muscle cells was detected every 20 s without any chemical modification to the CO. The sensitivity of the sensor reached 6.9 pmol CO. CO synthesis was measured from untreated control cells (0.25 nmol per 10(7) cells/h), sodium nitroprusside-treated cells (0.29 nmol per 10(7) cells/h), and hemin-treated cells (0.49 nmol per 10(7) cells/h). The sensor also detected decreases in CO production after the addition of the heme oxygenase (HO) inhibitor tin protoporphyrin-IX (from 0.49 to 0.02 nmol per 10(7) cells/h) and increases after the administration of the HO substrate hemin (from 0.27 to 0.64 nmol per 10(7) cells/h). These results demonstrate that midinfrared laser absorption spectroscopy is a useful technique for the noninvasive and real-time detection of trace levels of CO from biological tissues.

Non-NASA Center↗