Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Effects of flight instrumentation errors on the estimation of aircraft stability and control derivatives

An error analysis program based on an output error estimation method was used to evaluate the effects of sensor and instrumentation errors on the estimation of aircraft stability and control derivatives. A Monte Carlo analysis was performed using simulated flight data for a high performance military aircraft, a large commercial transport, and a small general aviation aircraft for typical cruise flight conditions. The effects of varying the input sequence and combinations of the sensor and instrumentation errors were investigated. The results indicate that both the parameter accuracy and the corresponding measurement trajectory fit error can be significantly affected. Of the error sources considered, instrumentation lags and control measurement errors were found to be most significant.

Bryant, W. H.↗

Evaluation of TRMM Ground-Validation Radar-Rain Errors Using Rain Gauge Measurements

Ground-validation (GV) radar-rain products are often utilized for validation of the Tropical Rainfall Measuring Mission (TRMM) spaced-based rain estimates, and hence, quantitative evaluation of the GV radar-rain product error characteristics is vital. This study uses quality-controlled gauge data to compare with TRMM GV radar rain rates in an effort to provide such error characteristics. The results show that significant differences of concurrent radar-gauge rain rates exist at various time scales ranging from 5 min to 1 day, despite lower overall long-term bias. However, the differences between the radar area-averaged rain rates and gauge point rain rates cannot be explained as due to radar error only. The error variance separation method is adapted to partition the variance of radar-gauge differences into the gauge area-point error variance and radar rain estimation error variance. The results provide relatively reliable quantitative uncertainty evaluation of TRMM GV radar rain estimates at various times scales, and are helpful to better understand the differences between measured radar and gauge rain rates. It is envisaged that this study will contribute to better utilization of GV radar rain products to validate versatile spaced-based rain estimates from TRMM, as well as the proposed Global Precipitation Measurement, and other satellites.

Wang, Jianxin↗

Space acceleration measurement system triaxial sensor head error budget

The objective of the Space Acceleration Measurement System (SAMS) is to measure and record the microgravity environment for a given experiment aboard the Space Shuttle. To accomplish this, SAMS uses remote triaxial sensor heads (TSH) that can be mounted directly on or near an experiment. The errors of the TSH are reduced by calibrating it before and after each flight. The associated error budget for the calibration procedure is discussed here.

Thomas, John E.↗

The link evaluation terminal for the advanced communications technology satellite experiments program

The experimental NASA satellite, Advanced Communications Technology Satellite (ACTS), introduces new technology for high throughput 30 to 20 GHz satellite services. Contained in a single communication payload is both a regenerative TDMA system and multiple 800 MHz 'bent pipe' channels routed to spot beams by a switch matrix. While only one mode of operation is typical during any experiment, both modes can operate simultaneously with reduced capability due to sharing of the transponder. NASA-Lewis instituted a ground terminal development program in anticipation of the satellite launch to verify the performance of the switch matrix mode of operations. Specific functions are built into the ground terminal to evaluate rain fade compensation with uplink power control and to monitor satellite transponder performance with bit error rate measurements. These functions were the genesis of the ground terminal's name, Link Evaluation Terminal, often referred to as LET. Connectors are included in LET that allow independent experimenters to run unique modulation or network experiments through ACTS using only the RF transmit and receive portions of LET. Test data indicate that LET will be able to verify important parts of ACTS technology and provide independent experimenters with a useful ground terminal. Lab measurements of major subsystems integrated into LET are presented. Bit error rate is measured with LET in an internal loopback mode.

May, Brian D.↗

The Link Evaluation Terminal for the Advanced Communications Technology Satellite Experiments Program

The experimental NASA satellite, Advanced Communications Technology Satellite (ACTS), introduces new technology for high throughput 30 to 20 GHz satellite services. Contained in a single communication payload is both a regenerative TDMA system and multiple 800 MHz 'bent pipe' channels routed to spot beams by a switch matrix. While only one mode of operation is typical during any experiment, both modes can operate simultaneously with reduced capability due to sharing of the transponder. NASA-Lewis instituted a ground terminal development program in anticipation of the satellite launch to verify the performance of the switch matrix mode of operations. Specific functions are built into the ground terminal to evaluate rain fade compensation with uplink power control and to monitor satellite transponder performance with bit error rate measurements. These functions were the genesis of the ground terminal's name, Link Evaluation Terminal, often referred to as LET. Connectors are included in LET that allow independent experimenters to run unique modulation or network experiments through ACTS using only the RF transmit and receive portions of LET. Test data indicate that LET will be able to verify important parts of ACTS technology and provide independent experimenters with a useful ground terminal. Lab measurements of major subsystems integrated into LET are presented. Bit error rate is measured with LET in an internal loopback mode.

May, Brian D.↗

Coding isotropic images

Rate distortion functions for two-dimensional homogeneous isotropic images are compared with the performance of 5 source encoders designed for such images. Both unweighted and frequency weighted mean square error distortion measures are considered. The coders considered are differential PCM (DPCM) using six previous samples in the prediction, herein called 6 pel (picutre element) DPCM; simple DPCM using single sample prediction; 6 pel DPCM followed by entropy coding; 8 x 8 discrete cosine transform coder, and 4 x 4 Hadamard transform coder. Other transform coders were studied and found to have about the same performance as the two transform coders above. With the mean square error distortion measure DPCM with entropy coding performed best. The relative performance of the coders changes slightly when the distortion measure is frequency weighted mean square error. The performance of all the coders was separated by only about 4 dB.

Oneal, J. B., Jr.↗

Quantitative shearography: error reduction by using more than three measurement channels

Shearography is a noncontact optical technique used to measure surface displacement derivatives. Full surface strain characterization can be achieved using shearography configurations employing at least three measurement channels. Each measurement channel is sensitive to a single displacement gradient component defined by its sensitivity vector. A matrix transformation is then required to convert the measured components to the orthogonal displacement gradients required for quantitative strain measurement. This transformation, conventionally performed using three measurement channels, amplifies any errors present in the measurement. This paper investigates the use of additional measurement channels using the results of a computer model and an experimental shearography system. Results are presented showing that the addition of a fourth channel can reduce the errors in the computed orthogonal components by up to 33% and that, by using 10 channels, reductions of around 45% should be possible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Error in Dasibi flight measurements of atmospheric ozone due to instrument wall-loss

Theory suggests that in laminar flow the percent loss of a trace constituent to the walls of a measuring instrument varies as P to the -2/3, where P is the total gas pressure. Preliminary laboratory ozone wall-loss measurements confirm this P to the -2/3 dependence. Accurate assessment of wall-loss is thus of particular importance for those balloon-borne instruments utilizing laminar flow at ambient pressure, since the ambient pressure decreases by a factor of 350 during ascent to 40 km. Measurements and extrapolations made for a Dasibi ozone monitor modified for balloon flight indicate that the wall-loss error at 40 km was between 6 and 30 percent and that the wall-loss error in the derived total ozone column-content for the region from the surface to 40 km altitude was between 2 and 10 percent. At 1000 mb, turbulence caused an order of magnitude increase in the Dasibi wall-loss.

Ainsworth, J. E.↗

A method of treating the non-grey error in total emittance measurements

In techniques for the rapid determination of total emittance, the sample is generally exposed to surroundings that are at a different temperature than the sample's surface. When the infrared spectral reflectance of the surface is spectrally selective, these techniques introduce an error into the total emittance values. Surfaces of aluminum overcoated with oxides of various thicknesses fall into this class. Because they are often used as temperature control coatings on satellites, their emittances must be accurately known. The magnitude of the error was calculated for Alzak and silicon oxide-coated aluminum and was shown to be dependent on the thickness of the oxide coating. The results demonstrate that, because the magnitude of the error is thickness-dependent, it is generally impossible or impractical to eliminate it by calibrating the measuring device.

Heaney, J. B.↗

Exploring the use of structural models to improve remote sensing agricultural estimates

Satellite estimates of agricultural characteristics often are not sufficiently precise for reliable use in small geographical regions. The precision of estimates of agricultural characteristics such as crop proportions and leaf area indexes can be increased by modeling ground observations as a function of satellite estimates. Linear regression models using least squares estimators of the model parameters are most often advocated as an appropriate methodology; however, least squares estimation requires that the predictor variables are measured without error, an unreasonable assumption for this application. An alternative estimation methodology which assumes that both the response variables (ground observations) and the predictor variables (satellite estimates) are measured with error involves the use of linear structural models. The application of linear structural models to the estimation of agricultural characteristics using satellite spectral measurements is examined.

Gunst, R. F.↗

SU-F-E-02: A Feasibility Study for Application of Metal Artifact Reduction Techniques in MR-Guided Brachytherapy Gynecological Cancer with Titanium Applicators

Purpose: Utilization of Titanium Tandem and Ring (T&R) applicators in MR-guided brachytherapy has become widespread for gynecological cancer treatment. However, Titanium causes magnetic field disturbance and susceptibility artifact, which complicate image interpretation. In this study, metal artifact reduction techniques were employed to improve the image quality and reduce the metal related artifacts. Methods: Several techniques were employed to reduce the metal artifact caused by titanium T&R applicator. These techniques include Metal Artifact Reduction Sequence (MARS), View Angle Tilting (VAT) to correct in-plane distortion, and Slice Encoding for Metal Artifact Correction (SEMAC) for through-plane artifact correction. Moreover, MARS can be combined with VAT to further reduce the in-plane artifact by reapplying the selection gradients during the readout (MARS+VAT). SEMAC uses a slice selective excitation but acquires additional z-encodings in order to resolve off-resonant signal and to reduce through-plane distortions. Results: Comparison between the clinical sequences revealed that increasing the bandwidth reduces the error in measured diameter of T&R. However, the error is larger than 4mm for the best case with highest bandwidth and spatial resolution. MARS+VAT with isotropic resolution of 1mm reduced the error to 1.9mm which is the least among the examined 2D sequences. The measured diameter of tandem from SEMAC+VAT has the closest value to the actual diameter of tandem (3.2mm) and the error was reduced to less than 1mm. In addition, SEMAC+VAT significantly reduces the blooming artifact in the ring compared to clinical sequences. Conclusion: A higher bandwidth and spatial resolution sequence reduces the artifact and diameter of applicator with a slight compromise in SNR. Metal artifact reduction sequences decrease the distortion associated with titanium applicator. SEMAC+VAT sequence in combination with VAT revealed promising results for titanium imaging and can be utilized for MR-guided brachytherapy in gynecological cancer. The author is employee with Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

MAXIMUM LIKELIHOOD ANALYSIS OF SYSTEMATIC ERRORS IN INTERFEROMETRIC OBSERVATIONS OF THE COSMIC MICROWAVE BACKGROUND

We investigate the impact of instrumental systematic errors in interferometric measurements of the cosmic microwave background (CMB) temperature and polarization power spectra. We simulate interferometric CMB observations to generate mock visibilities and estimate power spectra using the statistically optimal maximum likelihood technique. We define a quadratic error measure to determine allowable levels of systematic error that does not induce power spectrum errors beyond a given tolerance. As an example, in this study we focus on differential pointing errors. The effects of other systematics can be simulated by this pipeline in a straightforward manner. We find that, in order to accurately recover the underlying B-modes for r = 0.01 at 28 < l < 384, Gaussian-distributed pointing errors must be controlled to 0. Degree-Sign 7 root mean square for an interferometer with an antenna configuration similar to QUBIC, in agreement with analytical estimates. Only the statistical uncertainty for 28 < l < 88 would be changed at {approx}10% level. With the same instrumental configuration, we find that the pointing errors would slightly bias the 2{sigma} upper limit of the tensor-to-scalar ratio r by {approx}10%. We also show that the impact of pointing errors on the TB and EB measurements is negligibly small.

79 ASTRONOMY AND ASTROPHYSICS↗

Elastic functional principal component regression

We study regression using functional predictors in situations where these functions contains both phase and amplitude variability. In other words, the functions are misaligned due to errors in time measurements, and these errors can significantly degrade both model estimation and prediction performance. The current techniques either ignore the phase variability, or handle it via preprocessing, that is, use an off–the–shelf technique for functional alignment and phase removal. We develop a functional principal component regression model which has a comprehensive approach in handling phase and amplitude variability. The model utilizes a mathematical representation of the data known as the square–root slope function. These functions preserve the L 2 norm under warping and are ideally suited for simultaneous estimation of regression and warping parameters. Furthermore, using both simulated and real–world data sets, we demonstrate our approach and evaluate its prediction performance relative to current models. In addition, we propose an extension to functional logistic and multinomial logistic regression.

97 MATHEMATICS AND COMPUTING↗

Feasibility of using thermal response methods for nonintrusive compressed air flow measurement

Robust, low-cost nonintrusive flow meters are of interest in many industries. Particularly, a reliable nonintrusive flow measurement for the diagnosis of air leaks in compressed air systems is desirable. Measurement of the air flow due to leaks in the system ensures an accurate estimation of potential cost and energy savings. This study evaluates a novel method of using thermal responses to nonintrusively measure leakage rates in compressed air lines. The method uses heat and the resulting thermal response to calculate the flow rate inside the compressed air line. Compared to the current methods for flow measurement, this method can simplify flow measurement while decreasing the sensitivity to errors when measuring flow rates. In this study, the methodology of the proposed method is explained along with the potential advantages to the design. Two approaches are evaluated: a dynamic step response and sinusoidal frequency response. Simulated tests evaluate the feasibility of the proposed methods, followed by experiments that validate the simulation results. A clear correlation between the thermal step response and the flow rate indicate viability of the proposed method in simulation. Experimental results yielded similar results, confirming the validity of the proposed method. The results of a field test in an industrial environment demonstrate the capability of the approach to other flow rate measurement techniques.

42 ENGINEERING↗