Search NASA⌕ Search

SEARCH · Search NASA

Results for “microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Method and apparatus for removal of microscopic contaminant particulates from superconducting radio frequency cavities and cavity strings

A method and apparatus for removing microscopic contaminant particulates by high pressure liquid nitrogen jet cleaning from the inner surface of a superconducting radio frequency cavity or a string of multiple cavities and transporting the removed particulates out of the inner space enclosed by the cleaned surfaces. The cleaning method of the invention suppresses field emission, resulting in an increase of the usable accelerating gradient of the cavities and a reduction of the activated radioactivity in accelerator components around cavities.

Geng, Rongli↗

Using machine learning to jointly harness the strength of microscopic, fundamental-science driven and macroscopic, application-driven experiments

The PARADIGM project aims at accelerating progress in science by quantitatively answering the following question: What is the optimal combination of fundamental-science and application driven experiments to maximally reduce pertinent data uncertainties? Hence, we are bridging between microscopic experiments and data, and macroscopic simulations and experiments. Answering this question entails solving a high-dimensional and complex optimization problem which we solve with machine learning techniques.

LANSCE↗

Application of Machine Learning to Multigroup Microscopic Cross Sections

Presentation discussing the research and development of deep neural network models for modeling microscopic neutron cross-section data in the Griffin reactor physics application for pebble-bed reactors. This work details advancements made between the last review meeting in July 2024 until July 2025.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Microscopic return point memory in Co/Pd multilayer films

We report soft x-ray speckle metrology measurements of microscopic return point and complementary point memory in Co/Pd magnetic films having perpendicular anisotropy. We observe that the domains assemble into a common labyrinth phase with a period that varies by nearly a factor of two between initial reversal and fields near saturation. Unlike previous studies of similar systems, the ability of the film to reproduce its domain structure after magnetic cycling through saturation varies from loop to loop, from position to position on the sample, and with the part of the speckle pattern used in the metrology measurements. We report the distribution of memory as a function of field and discuss these results in terms of the reversal process.

36 MATERIALS SCIENCE↗

Metrology of multilayer Laue lens structures by means of scanning electron microscope imaging

Scanning electron microscope images obtained on a cross-section of a sputtered multilayer structure have proven to be crucial for qualifying these films for their intended use as a multilayer Laue lens. The quality of the linear Fresnel zone structure is assessed by means of image processing and analyses, and these analyses are then used to qualify the structure for further lens processing. The image analysis as well as problematic SEM artifacts are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High accuracy subwavelength distance measurements: A variable-angle standing-wave total-internal-reflection optical microscope

We describe an extension of the total-internal-reflection microscopy technique that permits direct in-plane distance measurements with high accuracy (<10 nm) over a wide range of separations. This high position accuracy arises from the creation of a standing evanescent wave and the ability to sweep the nodal positions (intensity minima of the standing wave) in a controlled manner via both the incident angle and the relative phase of the incoming laser beams. Some control over the vertical resolution is available through the ability to scan the incoming angle and with it the evanescent penetration depth.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiation microscope for SEE testing using GeV ions.

Radiation Effects Microscopy is an extremely useful technique in failure analysis of electronic parts used in radiation environment. It also provides much needed support for development of radiation hard components used in spacecraft and nuclear weapons. As the IC manufacturing technology progresses, more and more overlayers are used; therefore, the sensitive region of the part is getting farther and farther from the surface. The thickness of these overlayers is so large today that the traditional microbeams, which are used for REM are unable to reach the sensitive regions. As a result, higher ion beam energies have to be used (> GeV), which are available only at cyclotrons. Since it is extremely complicated to focus these GeV ion beams, a new method has to be developed to perform REM at cyclotrons. We developed a new technique, Ion Photon Emission Microscopy, where instead of focusing the ion beam we use secondary photons emitted from a fluorescence layer on top of the devices being tested to determine the position of the ion hit. By recording this position information in coincidence with an SEE signal we will be able to indentify radiation sensitive regions of modern electronic parts, which will increase the efficiency of radiation hard circuits.

43 PARTICLE ACCELERATORS↗

Guiding the Design of Heterogeneous Electrode Microstructures for Li-Ion Batteries: Microscopic Imaging, Predictive Modeling, and Machine Learning

Electrochemical and mechanical properties of lithium-ion battery materials are heavily dependent on their 3D microstructure characteristics. A quantitative understanding of the role played by stochastic microstructures is critical for the prediction of material properties and for guiding synthesis processes. Furthermore, tailoring microstructure morphology is also a viable way of achieving optimal electrochemical and mechanical performances of lithium-ion cells. To facilitate the establishment of microstructure-resolved modeling and design methods, a review covering spatially and temporally resolved imaging of microstructure and electrochemical phenomena, microstructure statistical characterization and stochastic reconstruction, microstructure-resolved modeling for property prediction, and machine learning for microstructure design is presented here. The perspectives on the unresolved challenges and opportunities in applying experimental data, modeling, and machine learning to improve the understanding of materials and identify paths toward enhanced performance of lithium-ion cells are presented.

25 ENERGY STORAGE↗

Automated vehicle microscopic energy consumption study (AV-Micro): Data collection and model development

While the Adaptive Cruise Control (ACC) system in automated vehicles (AVs) is expected to impact transportation energy significantly, existing AV energy consumption models only directly adopt those developed with Human-driven Vehicle (HV) data without even slight adaptation or calibration to accommodate unique AV energy consumption features. This study will investigate how accurately HV data-based models can predict the energy consumption of AVs. Empirical trajectory data and corresponding instantaneous energy consumption rates from both AVs and HVs were collected. We adopted two classical HV data-based models to fit these data. The calibration results indicated that these models yield around 20 30% prediction errors for AVs. To further improve the prediction accuracy, this study designed an AV-Micro model by incorporating components of multiple classic energy consumption models that better capture ACC energy consumption features, including piecewise driving behavior. With this, the AV-Micro model achieves lower than 10% prediction errors. The AV-Micro model’s high consistency across different test runs was verified with statistical significance tests, demonstrating its adaptability in different driving profiles. To confirm the discrepancies between the energy consumption features of AVs and HVs, more statistical significance tests were conducted to show that the AV-Micro model cannot be directly applied to HV data. The findings by calibrated AV-Micro models revealed that AVs consume approximately 80.5–146.4 J more energy than HVs for each meter traveled. Furthermore, the frequency analysis of energy consumption indicates that there is still some room for AVs to improve energy efficiency, particularly given their larger amplitude high-frequency fluctuations.

33 ADVANCED PROPULSION SYSTEMS↗

Understanding the formation and growth of Ag nanoparticles on silver chromate induced by electron irradiation in electron microscope: A combined experimental and theoretical study

Ag{sub 2}CrO{sub 4} microcrystals were synthesized using the co-precipitation method. These microcrystals were characterized through X-ray diffraction (XRD) with Rietveld analysis, field-emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM) with energy-dispersive spectroscopy (EDS), micro-Raman (MR). XRD patterns and Rietveld refinement data showed that the material exhibits an orthorhombic structure without any deleterious phases. FE-SEM and TEM micrographs revealed the morphology and the growth of Ag nanoparticles on Ag{sub 2}CrO{sub 4} microcrystals during electron beam irradiation. These events were directly monitored in real-time. Their optical properties were investigated using ultraviolet-visible (UV–vis) diffuse reflectance spectroscopy that allowed the calculation of the optical band gap energy. Theoretical analyses based on the density functional theory level indicate that the incorporation of electrons is responsible for structural modifications and formation of defects on the [AgO{sub 6}] and [AgO{sub 4}] clusters, generating ideal conditions for the growth of Ag nanoparticles. - Graphical abstract: Theoretical representation of the Ag{sub 2}CrO{sub 4} orthorhombic structure. Display Omitted - Highlights: • The Ag{sub 2}CrO{sub 4} microcrystals indicate an orthorhombic structure. • The formation of Ag{sup 0} promotes Ag-nanoparticle growth on the surface of the Ag{sub 2}CrO{sub 4}. • Electron irradiation of the material induces the formation of Ag vacancies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatiotemporal mapping of microscopic strains and defects to reveal Li-dendrite-induced failure in all-solid-state batteries

Solid-state electrolytes (SSEs) are key to the success and reliability of all-solid-state lithium batteries, potentially enabling improvements in terms of safety and energy density over state-of-the-art lithium-ion batteries. However, there are several critical challenges to their implementation, including the interfacial instability stemming from the dynamic interaction of as-formed dendritic lithium during cycling. Here, we emphasize the importance of studying the spatial distribution and temporal evolution of strains and defects in crystalline solid-state electrolytes at the micro-scale, and how this affects dendrite growth. A proof-of-principle study is demonstrated using the synchrotron radiation based micro Laue X-ray diffraction method, and a custom-developed in-situ cycling device. Defects and residual strains are mapped, and the evolution of intragranular misorientation is observed. The feasibility of using this technique is discussed, and recommendations for micro-strain engineering to address the Li/SSEs interfacial issues are given. Additionally, work directions are pointed out with the consideration of combining multi-techniques for “poly-therapy”.

36 MATERIALS SCIENCE↗

Micromechanical and in situ shear testing of Al–SiC nanolaminate composites in a transmission electron microscope (TEM)

Nanolaminate composites show promise as high strength and toughness materials. Still, due to the limited volume of these materials, micron scale mechanical testing methods must be used to determine the properties of these films. To this end, a novel approach combining a double notch shear testing geometry and compression with a flat punch in a nanoindenter was developed to determine the mechanical properties of these films under shear loading. To further elucidate the failure mechanisms under shear loading, in situ TEM experiments were performed using a double notch geometry cut into the TEM foil. Aluminum layer thicknesses of 50nm and 100nm were used to show the effect of constraint on the deformation. Higher shear strength was observed in the 50 nm sample (690±54 MPa) compared to the 100 nm sample (423±28.7 MPa). Additionally, failure occurred along the Al-SiC interface in the 50 nm sample as opposed to failure within the Al layer in the 100 nm sample.

36 MATERIALS SCIENCE↗

Reagent-free and portable detection of Bacillus anthracis spores using a microfluidic incubator and smartphone microscope

Rapid, cost-effective bacterial detection systems are needed to respond to potential biothreat events. Here we report the use of smartphone-based microscopy in combination with a simple microfluidic incubation device to detect 5000 Bacillus anthracis spores in 3 hours. This field-deployable approach is compatible with real-time PCR for secondary confirmation.

B. anthracis↗

Implementation on a desktop computer of the real time feedback control loop of a scanning probe microscope

A software package has been developed to implement the real time feedback control loop needed in scanning probe microscopy on a general purpose desktop computer of the current high-speed/multicore generation. The main features of the implementation of both the feedback loop and the control of the experiment on the same computer are discussed. The package can work with several general purpose data acquisition boards and can be extended in a modular way to further board models; timing performance has been tested with several hardware configurations and some applications common in scanning probe microscopy. The package is available under an Open Source license.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗