Neutron transfer in the C 13 + Au 197 reaction from gold isotope residuals

Residual gold nuclei were produced in this paper via neutron transfer at multiple energies using a 130-MeV 13 C beam incident on a stacked-foil target consisting of alternating layers of 197 Au and 27 Al. Production cross sections, over an energy range of 56 to 129 MeV, for seven gold isotopes and two gold isomers were determined through activation analysis. By using the Wilczynski binary transfer model with a modified version of the recoil formula and a standard evaporation model, we were able to reproduce the isotopic production cross sections at high beam energy, with some disagreement at lower beam energies. Finally, this limiting angular momentum model does not predict the transfer of sufficient angular momentum to reproduce the observed isomeric populations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using kernel-based statistical distance to study the dynamics of charged particle beams in particle-based simulation codes

Measures of discrepancy between probability distributions (statistical distance) are widely used in the fields of artificial intelligence and machine learning. We describe how certain measures of statistical distance can be implemented as numerical diagnostics for simulations involving charged-particle beams. Related measures of statistical dependence are also described. The resulting diagnostics provide sensitive measures of dynamical processes important for beams in nonlinear or high-intensity systems, which are otherwise difficult to characterize. Here, the focus is on kernel-based methods such as maximum mean discrepancy, which have a well-developed mathematical foundation and reasonable computational complexity. Several benchmark problems and examples involving intense beams are discussed. While the focus is on charged-particle beams, these methods may also be applied to other many-body systems such as plasmas or gravitational systems.

47 OTHER INSTRUMENTATION↗

Observation of Forward Neutron Multiplicity Dependence of Dimuon Acoplanarity in Ultraperipheral Pb-Pb Collisions at $\sqrt{s_{NN}}$ = 5.02 TeV

The first measurement of the dependence of $γγ → μ^+μ^–$ production on the multiplicity of neutrons emitted very close to the beam direction in ultraperipheral heavy ion collisions is reported. Data for lead-lead interactions at $\sqrt{s_{NN}}$ = 5.02 TeV, with an integrated luminosity of approximately 1.5 nb –1 , are collected using the CMS detector at the LHC. The azimuthal correlations between the two muons in the invariant mass region 8 < $m_{μμ}$ < 60 GeV are extracted for events including 0, 1, or at least 2 neutrons detected in the forward pseudorapidity range |η| > 8.3. The back-to-back correlation structure from leading-order photon-photon scattering is found to be significantly broader for events with a larger number of emitted neutrons from each nucleus, corresponding to interactions with a smaller impact parameter. This observation provides a data-driven demonstration that the average transverse momentum of photons emitted from relativistic heavy ions has an impact parameter dependence. These results provide new constraints on models of photon-induced interactions in ultraperipheral collisions. They also provide a baseline to search for possible final-state effects on lepton pairs caused by traversing a quark-gluon plasma produced in hadronic heavy ion collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physics-constrained superresolution diffusion for six-dimensional phase space diagnostics

Adaptive physics-constrained superresolution diffusion is developed for noninvasive virtual diagnostics of the six-dimensional (6D) phase space density of charged particle beams. An adaptive variational autoencoder embeds initial beam condition images and scalar measurements to a low-dimensional latent space from which a 32 6 pixel 6D tensor representation of the beam's 6D phase space density is generated. Projecting from a 6D tensor generates physically consistent two-dimensional projections. Physics-guided superresolution diffusion transforms low-resolution images of the 6D density to high resolution 256 × 256 pixel images. Unsupervised adaptive latent space tuning enables tracking of time-varying beams without knowledge of time-varying initial conditions. The method is demonstrated with experimental data and multiparticle simulations at the HiRES UED. The general approach is applicable to a wide range of complex dynamic systems evolving in high-dimensional phase space. The method is shown to be robust to distribution shift without retraining. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

Feasibility of one-shot-per-crystal structure determination using Laue diffraction

Structure determination was successfully carried out using single Laue exposures from a group of lysozyme crystals. The Laue method may be a viable option for collection of one-shot-per-crystal data from microcrystals. Crystal size is an important factor in determining the number of diffraction patterns which may be obtained from a protein crystal before severe radiation damage sets in. As crystal dimensions decrease this number is reduced, eventually falling to one, at which point a complete data set must be assembled using data from multiple crystals. When only a single exposure is to be collected from each crystal, the polychromatic Laue technique may be preferable to monochromatic methods owing to its simultaneous recording of a large number of fully recorded reflections per image. To assess the feasibility of solving structures using single Laue images from multiple crystals, data were collected using a ‘pink’ beam at the CHESS D1 station from groups of lysozyme crystals with dimensions of the order of 20–30 µm mounted on MicroMesh grids. Single-shot Laue data were used for structure determination by molecular replacement and correct solutions were obtained even when as few as five crystals were used.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detection of Petawatt Laser-Induced Muon Source for Rapid High-Z Material Detection

A proof-of-concept investigation of a rapid detection system for shielded high-Z material using a petawatt laser-based muon source is presented. Unlike cosmic-ray muons, a laser-induced muon beam has unique characteristics that can be exploited for use in a rapid detection system. These characteristics include: (1) a near-point source of muons, (2) well-characterized muon energies, and (3) directionality of the beam. A detector system is being developed that combines multiple muon detection technologies to characterize an active muon source. This detection system and the associated data acquisition and analysis techniques are designed to search for deflections of the muon beam as it passes through high-Z materials. Additionally, the ability of the system to differentiate muons from the expected secondary particles, such as high-energy gammas and electrons, is being explored. The detector system’s ability to differentiate muons from other particles, show muon angular distribution, and measured muon flux will be discussed.

scintillation detector, petawatt laser-based muon ↗

Development of a robust damage analysis scheme at the National Ignition Facility

The onset of laser-induced damage in optical materials is a limiting factor in the design and operation of most high-energy laser systems. As such, significant effort has been dedicated to developing laser damage testing protocols and procedures to inform laser system design and operating limits. These tests typically rely on multiple laser exposures for statistical validation. Historically, small beam single fluence (N / 1) or ramped fluence (R / 1) tests have been used to quantify the “laser-induced damage threshold” of a material. However, due to various distributions in damage precursor populations, the laser fluence at which damage occurs for a given sample varies with beam size and is therefore better described as the onset of observed damage for that testing geometry. In conclusion, we document the development of irradiation, measurement, and analysis methods for damage testing resulting in damage initiation density as a function of incident fluence or ρ(ϕ) which is suitable for both small and large beam area testing and more conducive to extrapolating from one to the other.

Beam diameter↗

SU-E-J-19: An Intra-Institutional Study of Cone-Beam CT Dose for Image-Guided Radiation Therapy

Purpose: To determine the variability of Cone-Beam CT Dose Index (CB-CTDI) across multiple on-board imaging (OBI) systems within a single institution, and compare this to manufacturer provided data. Methods: The CB-CTDI was measured on three Trilogy and three TrueBeam Varian OBI systems, for six different clinically used scan protocols. Measurements were taken using a 10 cm long CT ionization chamber in either a 16 cm (head-simulating) or 32 cm (body-simulating) diameter, acrylic, cylindrical, 15 cm long CTDI phantom. We assessed the variation in CB-CTDI between the OBI systems and compared our measured values to the data provided by the manufacturer. Results: The standard error in the CB-CTDI measured for all protocols was found to be within ±2% and ±5% of the mean for TrueBeam and Trilogy, respectively. For all head scan protocols, the measured TrueBeam values were lower than the manufacturer’s reported values, with a maximum difference of 13.9% and an average difference of 11%. For the body scan protocols, the TrueBeam measured values were 3% and 13% greater than the manufacturer’s reported values for two out of three protocols, and 38% lower than reported for the third protocol. In total, 7/18 CB-CTDI measurements fell within the manufacturers specified range (±10%). Across all scans the Truebeam machines were found to have a lower CB-CTDI than Trilogy, particularly the head scan protocols, which show decreases of up to 30% . Conclusion: The intra-institutional variation of CB-CTDI was found to be clinically acceptable at less than 5%. For the TrueBeam OBI system, over half of the measured scans failed to fall with in the manufactured quoted range of 10%, however, all measured values were within 15% of the manufacturer’s reported values. For accurate assessment and reporting of imaging dose to radiotherapy patients, our results indicate a need for standardization in CB-CTDI measurement technique.

60 APPLIED LIFE SCIENCES↗

SU-E-T-239: Design and Evaluation of a Nozzle Shielding System in Passively Scattered Proton Therapy

Purpose: To design, implement and evaluate a shielding system that will reduce out-of-field dose experienced by the patient and associated electronic systems in passively scattered proton therapy treatment. Methods: A multi-stage neutron shielding system was retrofitted to the Gantry 1 treatment nozzle at Loma Linda University Medical Center. The system uses multiple borated polyethylene plates staged after the primary beam modifying devices to attenuate and absorb neutrons produced by such devices. This arrangement locates increasing levels of shielding between the sources of secondary particles in the nozzle and the patient. Additionally, the design of this shielding structure allows it to be easily retrofitted to an existing proton nozzle system without impacting design or treatment beam characteristics. The effectiveness of the shielding was evaluated both through experimental measurements and Geant4 Monte Carlo simulations. Results: Measurements were completed with Landauer Luxel+ dosimeters that use optically stimulated luminescence and CR-39 to detect fast neutrons, thermal neutrons, protons, photons and beta particles. Measurements of a 250 MeV proton beam indicated that the shielding system reduced out-of-field dose to the patient by almost half with dose equivalent values at 50 and 40 cm from the field edge decreasing from 0.965 and 1.262 mSv/Gy to 0.596 and 0.777 mSv/Gy respectively. The installation of the multi-stage shielding system also reduced dose equivalent experienced by electronic systems installed in the treatment room by up to 80%. Geant4 simulations were also used to evaluate the neutron fluence at various positions in the treatment room as well as provide information on microdosimetry spectra within the patient and treatment room. Conclusion: The shielding system described above proved to be an effective an inexpensive method of reducing out-of-field doses to the patient and electronic systems and can be easily retrofitted to existing passive scattering nozzles.

60 APPLIED LIFE SCIENCES↗

SU-F-T-618: Evaluation of a Mono-Isocentric Treatment Planning Software for Stereotactic Radiosurgery of Multiple Brain Metastases

Purpose: To evaluate planning performance of an automated treatment planning software (BrainLAB; Elements) for stereotactic radiosurgery (SRS) of multiple brain metastases. Methods: Brainlab’s Multiple Metastases Elements (MME) uses single isocentric technique to treat up to 10 cranial planning target volumes (PTVs). The planning algorithm of the MME accounts for multiple PTVs overlapping with one another on the beam eyes view (BEV) and automatically selects a subset of all overlapping PTVs on each arc for sparing normal tissues in the brain. The algorithm also optimizes collimator angles, margins between multi-leaf collimators (MLCs) and PTVs, as well as monitor units (MUs) using minimization of conformity index (CI) for all targets. Planning performance was evaluated by comparing the MME-calculated treatment plan parameters with the same parameters calculated with the Volumetric Modulated Arc Therapy (VMAT) optimization on Varian’s Eclipse platform. Results: Figures 1 to 3 compare several treatment plan outcomes calculated between the MME and VMAT for 5 clinical multi-targets SRS patient plans. Prescribed target dose was volume-dependent and defined based on the RTOG recommendation. For a total number of 18 PTV’s, mean values for the CI, PITV, and GI were comparable between the MME and VMAT within one standard deviation (σ). However, MME-calculated MDPD was larger than the same VMAT-calculated parameter. While both techniques delivered similar maximum point doses to the critical cranial structures and total MU’s for the 5 patient plans, the MME required less treatment planning time by an order of magnitude compared to VMAT. Conclusion: The MME and VMAT produce similar plan qualities in terms of MUs, target dose conformation, and OAR dose sparing. While the selective use of PTVs for arc-optimization with the MME reduces significantly the total planning time in comparison to VMAT, the target dose homogeneity was also compromised due to its simplified inverse planning algorithm used.

60 APPLIED LIFE SCIENCES↗

Microturbines Formed with the Aid of Direct Laser Recording on Photoresist

A method for fabrication of mechanical elements (microturbines) that receive torque from vortex optical beams is proposed. Experimental results on fabrication of multiple microturbines are presented. Shapes of the microturbines are measured using an optical microscope, ZYGO white-light interferometer, and electron microscope.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ION EFFECTS IN THE APS PARTICLE ACCUMULATOR RING

Trapped ions in the APS Particle Accumulator Ring (PAR) lead to a positive coherent tune shift in both planes, which increases along the PAR cycle as more ions accumulate. This effect has been studied using an ion simulation code developed at SLAC. After modifying the code to include a realistic vacuum profile, multiple ionization, and the effect of shaking the beam to measure the tune, the simulation agrees well with our measurements. This code has also been used to evaluate the possibility of ion instabilities at the high bunch charge needed for the APS-Upgrade.

APS↗

Solenoidal Fields from Permanent Magnets for a Polarized Electron Preinjector

This technical note describes the design of a compact focusing solenoid constructed from permanent bar magnets, intended for the low-energy section of a spin-polarized electron injector. Typically, quadrupole triplets provide appropriate focusing for the low-energy spin rotator section; however, their large footprint precludes the insertion of sufficient beam diagnostics. The primary motivation of this study is to provide beam focusing while preserving the vertical spin orientation of the electron beam. We propose a solenoidal field composed of multiple permanent magnets arranged to naturally yield a zero longitudinal magnetic field integral ($\int B_zdz = 0$). This design serves as a compact, passive, and non-coupling alternative to traditional quadrupole triplets. We present the magnet arrangement, field calculation methodology, spin tracking simulations using space charge codes, and calculations demonstrating that the required field strength is achievable.

43 PARTICLE ACCELERATORS↗

Baltimore Social-Environmental Collaborative (BSEC) Doppler Lidar & Derived Products

This repository contains all processed Doppler‐lidar outputs from the PSU lidar deployed for the Baltimore Social‐Environmental Collaborative (BSEC) project. Vertical Stare Scans (fixed‐beam, vertical profiling): 1 Hz backscatter intensity (m⁻¹ sr⁻¹), signal‐to‐noise ratio (unitless), and Doppler vertical‐velocity (m s⁻¹) on ~30 m range gates, stored as CF-compliant NetCDF. Wind Profiles (horizontal‐wind retrieval): daily NetCDF outputs of retrieved horizontal wind speed (m s⁻¹) and direction (degrees), computed from the angled‐scan returns. Profile Statistics (summary statistics on the vertical velocity): 15 min windows (default) of mean, variance, skewness, kurtosis, high-frequency variance, etc., as a function of height; saved as CF-compliant NetCDF files. Boundary Layer Height (BLH) (fuzzy-logic output): 15 min BLH estimates (m), with lower/upper fuzzy bounds (m) and a quality flag (0–4) indicating data status (e.g., no data, good, below range, ran out of signal, cloud-topped). Cloud Base Height (Haar-gradient detection): 15 min estimates of cloud-base height (m) with a cloud-detection quality flag (0–3: none, low, moderate, high). All five product streams are organized by year and date under their own top-level folders (01_Vertical_Stare_Scans/ through 05_Cloud_Height/). Each folder contains a data_ /YYYY/ subdirectory with daily CF-compliant NetCDF outputs (96 windows per day at 15 min intervals). Global attributes in each file include creation history, version (2.0.0), institution, and source. Instrument & MeasurementsThe PSU Doppler Lidar samples aerosol backscatter (m⁻¹ sr⁻¹), signal-to-noise ratio, and radial velocity at ~1 Hz. Vertical stare scans point the beam straight up; after collecting angled scans through multiple elevation angles, the "Wind Profiles" product contains the fully retrieved horizontal wind speed and direction. Data were collected continuously at ~30 m range resolution, with a typical height ceiling of ~12 km. How to Use Open any NetCDF with Python's xarray, MATLAB, or similar CF-compliant tools. Stare scans and angled-scan retrievals (Wind Profiles) are CF-compliant daily NetCDF files. Profile-Statistics, BLH, and Cloud Height files are daily 15 min summaries (96 time steps per file). Inspect the included variables (e.g., vertical_velocity_variance, wind_speed, BLH, cloud_base_height) for your analyses. Use the quality flags (BLH_flag, cloud_flag) to filter out poor-quality retrievals. For more information or questions about processing methods, please contact:Nicholas E. Prince ⟨nec5299@psu.edu⟩Penn State Department of Meteorology & Atmospheric Science

Air Quality↗

Baltimore Social-Environmental Collaborative (BSEC) Doppler Lidar & Derived Products

This repository contains all processed Doppler‐lidar outputs from the PSU lidar deployed for the Baltimore Social‐Environmental Collaborative (BSEC) project. Vertical Stare Scans (fixed‐beam, vertical profiling): 1 Hz backscatter intensity (m⁻¹ sr⁻¹), signal‐to‐noise ratio (unitless), and Doppler vertical‐velocity (m s⁻¹) on 30 m range gates (and 3 m range gates), stored as CF-compliant NetCDF. Wind Profiles (horizontal‐wind retrieval): daily NetCDF outputs of retrieved horizontal wind speed (m s⁻¹) and direction (degrees), computed from the angled‐scan returns. Profile Statistics (summary statistics on the vertical velocity): 15 min windows (default) of mean, variance, skewness, kurtosis, high-frequency variance, etc., as a function of height; saved as CF-compliant NetCDF files. Boundary Layer Height (BLH) (fuzzy-logic output): 15 min BLH estimates (m), with lower/upper fuzzy bounds (m) and a quality flag (0–4) indicating data status (e.g., no data, good, ran out of signal, below range, cloud-topped). Cloud Base Height (Haar-gradient detection): 10 min estimates of cloud-base height (m). All five product streams are organized by year and date under their own top-level folders (01_Vertical_Stare_Scans/ through 05_Cloud_Height/). Each folder contains a data_ /YYYY/ subdirectory with daily CF-compliant NetCDF outputs (96 windows per day at 15 min intervals). Global attributes in each file include creation history, version (3.0.0), institution, and source. Instrument & MeasurementsThe PSU Doppler Lidar samples aerosol backscatter (m⁻¹ sr⁻¹), signal-to-noise ratio, and radial velocity at ~1 Hz. Vertical stare scans point the beam straight up; after collecting angled scans through multiple elevation angles, the "Wind Profiles" product contains the fully retrieved horizontal wind speed and direction. Data were collected continuously at ~30 m range resolution (and 3 m for the year of 2025), with a typical height ceiling of ~12 km. How to Use Open any NetCDF with Python's xarray, MATLAB, or similar CF-compliant tools. Stare scans and angled-scan retrievals (Wind Profiles) are CF-compliant daily NetCDF files. Profile-Statistics, BLH, and Cloud Height files are daily 15 min (10 min for Cloud Heights) summaries (96 time steps per file). Inspect the included variables (e.g., vertical_velocity_variance, wind_speed, BLH, cloud_base_height) for your analyses. Use the quality flags (BLH_flag, cloud_flag) to filter out poor-quality retrievals. For more information or questions about processing methods, please contact:Nicholas E. Prince ⟨nec5299@psu.edu⟩Penn State Department of Meteorology & Atmospheric Science

Air Quality↗