Search NASA⌕ Search

SEARCH · Search NASA

Results for “program compilers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Evaluation of Final Radiological Conditions at Areas of the Niagara Falls Storage Site Remediated under the Formerly Utilized Sites Remedial Action Program -12184

The U. S. Department of Energy (DOE) methods and protocols allow evaluation of remediation and final site conditions to determine if remediated sites remain protective. Two case studies are presented that involve the Niagara Falls Storage Site (NFSS) and associated vicinity properties (VPs), which are being remediated under the Formerly Utilized Sites Remedial Action Program (FUSRAP). These properties are a part of the former Lake Ontario Ordnance Works (LOOW). In response to stakeholders concerns about whether certain remediated NFSS VPs were putting them at risk, DOE met with stakeholders and agreed to evaluate protectiveness. Documentation in the DOE records collection adequately described assessed and final radiological conditions at the completed VPs. All FUSRAP wastes at the completed sites were cleaned up to meet DOE guidelines for unrestricted use. DOE compiled the results of the investigation in a report that was released for public comment. In conducting the review of site conditions, DOE found that stakeholders were also concerned about waste from the Separations Process Research Unit (SPRU) at the Knolls Atomic Power Laboratory (KAPL) that was handled at LOOW. DOE agreed to determine if SPRU waste remained at that needed to be remediated. DOE reviewed records of waste characterization, historical handling locations and methods, and assessment and remediation data. DOE concluded that the SPRU waste was remediated on the LOOW to levels that pose no unacceptable risk and allow unrestricted use and unlimited exposure. This work confirms the following points as tenets of an effective long-term surveillance and maintenance (LTS&M) program: Stakeholder interaction must be open and transparent, and DOE must respond promptly to stakeholder concerns. DOE, as the long-term custodian, must collect and preserve site records in order to demonstrate that remediated sites pose no unacceptable risk. DOE must continue to maintain constructive relationships with the U.S. Army Corps of Engineers and state and federal regulators.

Remediation, Niagara Falls Storage Site, Lake Onta↗

Evaluation of Final Radiological Conditions at Areas of the Niagara Falls Storage Site Remediated under the Formerly Utilized Sites Remedial Action Program - 12184

The U.S. Department of Energy (DOE) methods and protocols allow evaluation of remediation and final site conditions to determine if remediated sites remain protective. Two case studies are presented that involve the Niagara Falls Storage Site (NFSS) and associated vicinity properties (VPs), which are being remediated under the Formerly Utilized Sites Remedial Action Program (FUSRAP). These properties are a part of the former Lake Ontario Ordnance Works (LOOW). In response to stakeholders concerns about whether certain remediated NFSS VPs were putting them at risk, DOE met with stakeholders and agreed to evaluate protectiveness. Documentation in the DOE records collection adequately described assessed and final radiological conditions at the completed VPs. All FUSRAP wastes at the completed sites were cleaned up to meet DOE guidelines for unrestricted use. DOE compiled the results of the investigation in a report that was released for public comment. In conducting the review of site conditions, DOE found that stakeholders were also concerned about waste from the Separations Process Research Unit (SPRU) at the Knolls Atomic Power Laboratory (KAPL) that was handled at LOOW. DOE agreed to determine if SPRU waste remained at that needed to be remediated. DOE reviewed records of waste characterization, historical handling locations and methods, and assessment and remediation data. DOE concluded that the SPRU waste was remediated on the LOOW to levels that pose no unacceptable risk and allow unrestricted use and unlimited exposure. This work confirms the following points as tenets of an effective long-term surveillance and maintenance (LTS and M) program: - Stakeholder interaction must be open and transparent, and DOE must respond promptly to stakeholder concerns. - DOE, as the long-term custodian, must collect and preserve site records in order to demonstrate that remediated sites pose no unacceptable risk. - DOE must continue to maintain constructive relationships with the U.S. Army Corps of Engineers and state and federal regulators. After review of historical site documentation, DOE reports, and USACE radiological data, DOE concluded the following: - DOE had access to adequate documentation to evaluate site conditions at the former LOOW. This is important to confirm now, while institutional knowledge of early FUSRAP work remains available. - DOE remediated the completed VPs to conditions that are protective for unrestricted residential use. Sample and walkover gamma scan results indicate that no wastes remain that exceed cleanup criteria. - Process knowledge and field observations establish that Cs-137 is the predominant radionuclide in the KAPL waste stream. Cs-137, a strong gamma emitter, was used as an indicator for remediation of KAPL waste. Other radionuclides were present in much lower relative concentrations and were likely also removed during remediation of the VPs. - KAPL contaminants were removed during remedial activities at the former LOOW as either co-located or co-mingled with other radionuclides. - For the active VPs (VP-E, VP-E', and VP-G), results of DOE's cleanup of the accessible portions of these properties indicate that KAPL waste does not remain at concentrations greater than the DOE cleanup limit: - Inaccessible areas were not associated with historic KAPL waste handling. Therefore, it is unlikely that KAPL waste remains on the active VPs. - Because gamma activity was used by DOE during remediation/verification activities for excavation control, additional USACE cleanup of FUSRAP wastes on these properties will likely result in the remediation of any co-located residual KAPL wastes to acceptable levels or identification of KAPL waste that is not co-located. - Although USACE has not established a cleanup level for Cs-137 on the active NFSS VPs, DOE assessment and remediation data indicate that assessed Cs-137 was remediated and significant Cs-137 is unlikely to remain. Because of the low likelihood of encountering significant KAPL waste on the active NFSS VPs, additional remediation is not anticipated at these properties. - USACE assessment soil sampling results on the NFSS proper indicate that KAPL waste does not exceed the DOE cleanup level for Cs-137. USACE has not established a cleanup level for Cs-137 on NFSS proper. The USACE cleanup of FUSRAP wastes on the NFSS proper will likely result in the remediation of any co-located residual KAPL wastes or identification of KAPL waste that is not co-located. DOE is drafting a report of the investigation of KAPL waste at LOOW. The report will be released to the public for comment when the draft is complete. DOE responses to stakeholder inquiries resulted in a common understanding of site conditions and site risk. DOE expects additional interaction with stakeholders at the former LOOW as USACE completes remediation of the active VPs and the NFSS proper, and these relationships will hopefully have built trust between DOE and the stakeholders that DOE will perform its duties in an open and transparent manner that includes stakeholders as stewards for remediated FUSRAP sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimized thermodynamic properties of REE aqueous species (REE 3+ and REEOH 2+ ) and experimental database for modeling the solubility of REE phosphate minerals (monazite, xenotime, and rhabdophane) from 25 to 300 °C

Rare earth elements (REE) are critical elements found in monazite, xenotime, and hydrated REE phosphates which typically form in hydrothermal mineral deposits. Accurate predictions of the solubility of these REE phosphates and the speciation of REE in aqueous fluids are both key to understanding the controls on the transport, fractionation, and deposition of REE in natural systems. Previous monazite and xenotime solubility experiments indicate the presence of large discrepancies between experimentally derived solubility constants versus calculated solubilities by combining different data sources for the thermodynamic properties of minerals and aqueous species at hydrothermal conditions. In this study, these discrepancies were resolved by using the program GEMSFITS to optimize the standard partial molal Gibbs energy of formation (Δ f G° 298 ) of REE aqueous species (REE 3+ and REE hydroxyl complexes) at 298.15 K and 1 bar while keeping the thermodynamic properties fixed for the REE phosphates. A comprehensive experimental database was compiled using solubility data available between 25 and 300 °C. The latter permits conducting thermodynamic parameter optimization of Δ f G° 298 for REE aqueous species. Optimal matching of the rhabdophane solubility data between 25 and 100 °C requires modifying the Δ f G° 298 values of REE 3+ by 1–6 kJ/mol, whereas matching of the monazite solubility data between 100 and 300 °C requires modifying the Δ f G° 298 values of both REE 3+ and REEOH 2+ by ~15–31 kJ/mol and ~2–10 kJ/mol, respectively. For xenotime, adjustments of Δ f G° 298 values by 1–26 kJ/mol are only necessary for the REE 3+ species. The optimizations indicate that the solubility of monazite in acidic solutions is controlled by the light (L)REE 3+ species at <150 °C and the LREEOH 2+ species at >150 °C, whereas the solubility of xenotime is controlled by the heavy (H)REE 3+ species between 25 and 300 °C. Based on the optimization results, we conclude that the revised Helgeson-Kirkham-Flowers equation of state does not reliably predict the thermodynamic properties of REE 3+ , REEOH 2+ , and likely other REE hydroxyl species at hydrothermal conditions. We therefore provide an experimental database (ThermoExp_REE) as a basic framework for future updates, extensions with other ligands, and optimizations as new experimental REE data become available. As a result, the optimized thermodynamic properties of aqueous species and minerals are available open access to accurately predict the solubility of REE phosphates in fluid-rock systems.

58 GEOSCIENCES↗

IPEAT+: A Built-In Optimization and Automatic Calibration Tool of SWAT+

For almost 30 years, the Soil and Water Assessment Tool (SWAT) has been successfully implemented to address issues around various scientific subjects in the world. On the other hand, it has been reaching to the limit of potential flexibility in further development by the current structure. The new generation SWAT, dubbed SWAT+, was released recently with entirely new coding features. SWAT+ is designed to have far more advanced functions and capacities to handle challenging watershed modeling tasks for hydrologic and water quality processes. However, it is still inevitable to conduct model calibration before the SWAT+ model is applied to engineering projects and research programs. The primary goal of this study is to develop an open-source, easy-to-operate automatic calibration tool for SWAT+, dubbed IPEAT+ (Integrated Parameter Estimation and Uncertainty Analysis Tool Plus). There are four major advantages: (i) Open-source code to general users; (ii) compiled and integrated directly with SWAT+ source code as a single executable; (iii) supported by the SWAT developer group; and, (iv) built with efficient optimization technique. The coupling work between IPEAT+ and SWAT+ is fairly simple, which can be conducted by users with minor efforts. IPEAT+ will be regularly updated with the latest SWAT+ revision. If users would like to integrate IPEAT+ with various versions of SWAT+, only few lines in the SWAT+ source code are required to be updated. IPEAT+ is the first automatic calibration tool integrated with SWAT+ source code. Users can take advantage of the tool to pursue more cutting-edge and forward-thinking scientific questions.

54 ENVIRONMENTAL SCIENCES↗

A study of system requirements for Phobos/Deimos missions. Volume 4: Phase 3 results, combined missions to Mars and its satellites

Combined missions to Mars and Phobos/Deimos were considered in relation to large scientific returns at a low total cost. A matrix of all feasible major combined mission concepts was compiled. The most promising approach was selected from which a nominal mission profile was developed. A systems analysis was performed to trade off performance, configuration, and cost characteristics of candidate mission concepts. Configuration and subsystem optimization analysis were then conducted from which a baseline and an alternate program were selected. Program schedules and cost estimates were prepared for the recommended and alternate program.

Source record↗

Approach and status for a unified national plan for satellite remote sensing research and development

Public Law 98-365, the Land Remote-Sensing Commercialization Act of 1984, requires that the Secretary of the Department of Commerce and the Administrator of the National Aeronautics and Space Administration 'shall, within one year after the date of the Law's enactment and biennially thereafter, jointly develop and transmit to the Congress a report that includes (1) a unified national plan for remote-sensing research and development applied to the earth and its atmosphere; (2) a compilation of progress in the relevant on-going research and development activities of Federal agencies; and (3) an assessment of the state of our knowledge of the Earth and its atmosphere, the needs for additional research (including research related to operational Federal remote-sensing space programs), and opportunities available for further progress'. NASA and NOAA have organized a series of public forums to encourage interest and discussion of the national plan.

Butera, Kristine↗

A generic fine-grained parallel C

With the present availability of parallel processors of vastly different architectures, there is a need for a common language interface to multiple types of machines. The parallel C compiler, currently under development, is intended to be such a language. This language is based on the belief that an algorithm designed around fine-grained parallelism can be mapped relatively easily to different parallel architectures, since a large percentage of the parallelism has been identified. The compiler generates a FORTH-like machine-independent intermediate code. A machine-dependent translator will reside on each machine to generate the appropriate executable code, taking advantage of the particular architectures. The goal of this project is to allow a user to run the same program on such machines as the Massively Parallel Processor, the CRAY, the Connection Machine, and the CYBER 205 as well as serial machines such as VAXes, Macintoshes and Sun workstations.

Hamet, L.↗

Production of SSM/I data sets

This Final Report is a summary of the work that was performed under Contract NAS8-38075 between NASA Marshall Space Flight Center and Remote Sensing Systems from September 1989 to September 1992. The primary accomplishment was the delivery of Special Sensor Microwave/Imager (SSM/I) data tapes containing sensor and geophysical products. In all, 515 tapes (80 gigabytes) were delivered. These tapes contained the F08 SSM/I data for the period from July 1988 through December 1991 and the F10 SSM/I data for the period from December 1990 through December 1991. For the F08 SSM/I, a data inventory was compiled and an engineering assessment was done. Ephemeris tables for the F08 and F10 spacecrafts were computed. Scientific studies on the oceanic wind vector and water vapor field were published, and color atlases of monthly ocean products were produced. This investigation was part of NASA's WETNET program.

Wentz, Frank J.↗

Efficient instruction sequencing with Inline Target Insertion

Inline target insertion, a specific compiler and pipeline implementation method for delayed branches with squashing, is defined. The method is shown to offer two important features not discovered in previous studies. First, branches inserted into branch slots are correctly executed. Second, the execution returns correctly from interrupts or exceptions with only one program counter. These two features result in better performance and less software/hardware complexity than conventional delayed branching mechanisms.

Hwu, Wen-Mei W.↗

Windowing System For Test And Simulation

Windowing System for Test and Simulation (WFI) computer program is Turbo-Pascal-class library enabling easy and flexible writing of data to window-type displays. Application programmer's interface simple, small, and powerful, eliminating steep learning curve of other window programming systems. Each routine specifically designed to operate in real-time testing and measurement environments or as part of simulation process. Written in Turbo Pascal v6.0 for IBM PC-series and compatible computers running MS-DOS. Turbo Pascal v6.0 or v7.0 (Borland) required to compile source code.

Katz, R.↗

NASA Langley Scientific and Technical Information Output, 1995

This document is a compilation of the scientific and technical information that the Langley Research Center has produced during the calendar year 1995. Included are citations for formal reports, high-numbered conference publications, high-numbered technical memorandums, contractor reports, journal articles and other publications, meeting presentations, technical talks, computer programs, tech briefs, and patents.

Stewart, Susan H.↗

NASA Langley Scientific and Technical Information Output: 1996

This document is a compilation of the scientific and technical information that the Langley Research Center has produced during the calendar year 1996. Included are citations for Formal Reports, High-Numbered Conference Publications, High-Numbered Technical Memorandums, Contractor Reports, Journal Articles and Other Publications, Meeting Presentations, Technical Talks, Computer Programs, Tech Briefs, and Patents.

Stewart, Susan H.↗

International Space Station Passive Thermal Control System Analysis, Top Ten Lessons-Learned

The International Space Station (ISS) has been on-orbit for over 10 years, and there have been numerous technical challenges along the way from design to assembly to on-orbit anomalies and repairs. The Passive Thermal Control System (PTCS) management team has been a key player in successfully dealing with these challenges. The PTCS team performs thermal analysis in support of design and verification, launch and assembly constraints, integration, sustaining engineering, failure response, and model validation. This analysis is a significant body of work and provides a unique opportunity to compile a wealth of real world engineering and analysis knowledge and the corresponding lessons-learned. The analysis lessons encompass the full life cycle of flight hardware from design to on-orbit performance and sustaining engineering. These lessons can provide significant insight for new projects and programs. Key areas to be presented include thermal model fidelity, verification methods, analysis uncertainty, and operations support.

Iovine, John↗

Risk-Significant Adverse Condition Awareness Strengthens Assurance of Fault Management Systems

As spaceflight systems increase in complexity, Fault Management (FM) systems are ranked high in risk-based assessment of software criticality, emphasizing the importance of establishing highly competent domain expertise to provide assurance. Adverse conditions (ACs) and specific vulnerabilities encountered by safety- and mission-critical software systems have been identified through efforts to reduce the risk posture of software-intensive NASA missions. Acknowledgement of potential off-nominal conditions and analysis to determine software system resiliency are important aspects of hazard analysis and FM. A key component of assuring FM is an assessment of how well software addresses susceptibility to failure through consideration of ACs. Focus on significant risk predicted through experienced analysis conducted at the NASA Independent Verification & Validation (IV&V) Program enables the scoping of effective assurance strategies with regard to overall asset protection of complex spaceflight as well as ground systems. Research efforts sponsored by NASAs Office of Safety and Mission Assurance (OSMA) defined terminology, categorized data fields, and designed a baseline repository that centralizes and compiles a comprehensive listing of ACs and correlated data relevant across many NASA missions. This prototype tool helps projects improve analysis by tracking ACs and allowing queries based on project, mission type, domain/component, causal fault, and other key characteristics. Vulnerability in off-nominal situations, architectural design weaknesses, and unexpected or undesirable system behaviors in reaction to faults are curtailed with the awareness of ACs and risk-significant scenarios modeled for analysts through this database. Integration within the Enterprise Architecture at NASA IV&V enables interfacing with other tools and datasets, technical support, and accessibility across the Agency. This paper discusses the development of an improved workflow process utilizing this database for adaptive, risk-informed FM assurance that critical software systems will safely and securely protect against faults and respond to ACs in order to achieve successful missions.

IV&V↗

Risk-Significant Adverse Condition Awareness Strengthens Assurance of Fault Management Systems

As spaceflight systems increase in complexity, Fault Management (FM) systems are ranked high in risk-based assessment of software criticality, emphasizing the importance of establishing highly competent domain expertise to provide assurance. Adverse conditions (ACs) and specific vulnerabilities encountered by safety- and mission-critical software systems have been identified through efforts to reduce the risk posture of software-intensive NASA missions. Acknowledgement of potential off-nominal conditions and analysis to determine software system resiliency are important aspects of hazard analysis and FM. A key component of assuring FM is an assessment of how well software addresses susceptibility to failure through consideration of ACs. Focus on significant risk predicted through experienced analysis conducted at the NASA Independent Verification Validation (IVV) Program enables the scoping of effective assurance strategies with regard to overall asset protection of complex spaceflight as well as ground systems. Research efforts sponsored by NASA's Office of Safety and Mission Assurance defined terminology, categorized data fields, and designed a baseline repository that centralizes and compiles a comprehensive listing of ACs and correlated data relevant across many NASA missions. This prototype tool helps projects improve analysis by tracking ACs and allowing queries based on project, mission type, domaincomponent, causal fault, and other key characteristics. Vulnerability in off-nominal situations, architectural design weaknesses, and unexpected or undesirable system behaviors in reaction to faults are curtailed with the awareness of ACs and risk-significant scenarios modeled for analysts through this database. Integration within the Enterprise Architecture at NASA IVV enables interfacing with other tools and datasets, technical support, and accessibility across the Agency. This paper discusses the development of an improved workflow process utilizing this database for adaptive, risk-informed FM assurance that critical software systems will safely and securely protect against faults and respond to ACs in order to achieve successful missions.

Fault management↗

International Space Station Passive Thermal Control System Top Ten Lessons-Learned

Final document not an Abstract attached. The International Space Station (ISS) has been on-orbit for nearly 20 years, and there have been numerous technical challenges along the way from design to assembly to on-orbit anomalies and repairs. The Passive Thermal Control System (PTCS) management team has been a key player in successfully dealing with these challenges. The PTCS team performs thermal analysis in support of design and verification, launch and assembly constraints, integration, sustaining engineering, failure response, and model validation. This analysis is a significant body of work and provides a unique opportunity to compile a wealth of real world engineering and analysis knowledge and the corresponding lessons-learned. The PTCS lessons encompass the full life cycle of flight hardware from design to on-orbit performance and sustaining engineering. These lessons can provide significant insight for new projects and programs. Key areas to be presented include thermal model fidelity, verification methods, analysis uncertainty, and operations support.

Iovine, John V.↗

International Space Station Passive Thermal Control System Top Ten Lessons-Learned

Final document not an Abstract attached. The International Space Station (ISS) has been on-orbit for nearly 20 years, and there have been numerous technical challenges along the way from design to assembly to on-orbit anomalies and repairs. The Passive Thermal Control System (PTCS) management team has been a key player in successfully dealing with these challenges. The PTCS team performs thermal analysis in support of design and verification, launch and assembly constraints, integration, sustaining engineering, failure response, and model validation. This analysis is a significant body of work and provides a unique opportunity to compile a wealth of real world engineering and analysis knowledge and the corresponding lessons-learned. The PTCS lessons encompass the full life cycle of flight hardware from design to on-orbit performance and sustaining engineering. These lessons can provide significant insight for new projects and programs. Key areas to be presented include thermal model fidelity, verification methods, analysis uncertainty, and operations support.

Iovine, John V.↗

ON THE EFFECTIVENESS OF LLMS IN UNIT TEST GENERATION FOR STRUCTURED TEXT PROGRAMS

The reliability of industrial automation systems heavily depends on the correctness of Programmable Logic Controller (PLC) programs, which are often written in Structured Text (ST). While Large Language Models (LLMs) have shown promise in automating test generation for mainstream programming languages, their effectiveness for the syntactically strict ST language remains underexplored. This thesis presents a systematic empirical evaluation of three state-of-the-art LLMs—GPT-4o, Gemini 2.5 Pro, and Claude Sonnet 4.5—for generating ST unit tests. We examine three prompting strategies: Natural Language (NL), Code Language (CL), and Chain-of-Thought (CoT), across a curated set of 11 ST function blocks. The quality of the generated tests is assessed using Compilation Success Rate (CSR), Statement Coverage (SC), and Branch Coverage (BC). In the zero-shot setting, Claude Sonnet 4.5 achieves the highest CSR, while Gemini 2.5 Pro consistently delivers the best statement and branch coverage, particularly under CL prompts. By incorporating a one-shot CL prompt, all models exhibit substantial improvements—most notably GPT-4o, whose CSR increases from 45.45% to 90.91%, with substantial gains in both SC and BC. To further contextualize these findings, we compare GPT-4o’s one-shot results with PLCAutoTester, a state-ofthe- art ST unit test generation tool, on an additional benchmark dataset. While LLMgenerated tests approach competitive coverage levels, PLCAutoTester maintains significantly higher and more stable coverage across programs. This study provides the first comprehensive benchmark of modern LLMs for ST unit testing, highlighting their strengths, limitations, and improvements through one-shot prompting, and positioning their performance relative to specialized automated testing tools in industrial automation.

42 ENGINEERING↗