Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Infrared spectroscopic investigation of nuclear spin conversion in solid CH{sub 4}

Infrared spectra of solid CH{sub 4} were studied in the ν{sub 3} and ν{sub 4} vibrational regions. The phase I crystal around 30 K showed broad absorption bands, whereas the phase II crystal at 6.9–10.3 K exhibited splitting of these bands after annealing above 20 K. The split peaks were assigned to the librating and almost freely rotating molecules in phase II on the basis of the peak spacings and time evolution of the peak intensities. From the quantitative analysis of the temporal changes of the R(0) and R(1) peak intensities, the relaxation rates of the numbers of molecules with J = 0 (I = 2) and J = 1 (I = 1) were determined in the temperature range of 6.9–10.3 K. We fitted the function resulting from a combination of direct and indirect relaxation processes mediated by phonons to the temperature dependence of these rates and obtained the activation energies of the indirect process: C ≃ 36 K. Since this value is higher than the energies of perturbed J = 2 states relative to the J = 1 state, we argue that the nuclear spin conversion through the J = 3 state also takes place.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing nanoscale scanning probes using electron microscopy: A novel fixture and a practical guide

The nanoscale geometry of probe tips used for atomic force microscopy (AFM) measurements determines the lateral resolution, contributes to the strength of the tip-surface interaction, and can be a significant source of uncertainty in the quantitative analysis of results. While inverse imaging of the probe tip has been used successfully to determine probe tip geometry, direct observation of the tip profile using electron microscopy (EM) confers several advantages: it provides direct (rather than indirect) imaging, requires fewer algorithmic parameters, and does not require bringing the tip into contact with a sample. In the past, EM-based observation of the probe tip has been achieved using ad hoc mounting methods that are constrained by low throughput, the risk of contamination, and repeatability issues. We report on a probe fixture designed for use in a commercial transmission electron microscope that enables repeatable mounting of multiple AFM probes as well as a reference grid for beam alignment. This communication describes the design, fabrication, and advantages of this probe fixture, including full technical drawings for machining. Further, best practices are discussed for repeatable, non-destructive probe imaging. Finally, examples of the fixture’s use are described, including characterization of common commercial AFM probes in their out-of-the-box condition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge transfer in dissociating iodomethane and fluoromethane molecules ionized by intense femtosecond X-ray pulses

Ultrafast electron transfer in dissociating iodomethane and fluoromethane molecules was studied at the Linac Coherent Light Source free-electron laser using an ultraviolet pump, X-ray-probe scheme. The results for both molecules are discussed with respect to the nature of their UV excitation and different chemical properties. Signatures of long distance intramolecular charge transfer are observed for both species, and a quantitative analysis of its distance dependence in iodomethane is carried out for charge states up to I 21þ. The reconstructed critical distances for electron transfer are in good agreement with a classical over-the-barrier model and with an earlier experiment employing a near infrared pump pulse. VC 2016 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution (CC BY) license (http:// creativecommons.org/licenses/by/4.0/). [http://dx.doi.org/10.1063/1.4944344]

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bifurcation, chaos, and scan instability in dynamic atomic force microscopy

The dynamical motion at any point on the cantilever of an atomic force microscope can be expressed quite generally as a superposition of simple harmonic oscillators corresponding to the vibrational modes allowed by the cantilever shape. Central to the dynamical equations is the representation of the cantilever-sample interaction force as a polynomial expansion with coefficients that account for the interaction force “stiffness,” the cantilever-to-sample energy transfer, and the displacement amplitude of cantilever oscillation. Renormalization of the cantilever beam model shows that for a given cantilever drive frequency cantilever dynamics can be accurately represented by a single nonlinear mass-spring model with frequency-dependent stiffness and damping coefficients [S. A. Cantrell and J. H. Cantrell, J. Appl. Phys. 110, 094314 (2011)]. Application of the Melnikov method to the renormalized dynamical equation is shown to predict a cascade of period doubling bifurcations with increasing cantilever drive force that terminates in chaos. The threshold value of the drive force necessary to initiate bifurcation is shown to depend strongly on the cantilever setpoint and drive frequency, effective damping coefficient, nonlinearity of the cantilever-sample interaction force, and the displacement amplitude of cantilever oscillation. The model predicts the experimentally observed interruptions of the bifurcation cascade for cantilevers of sufficiently large stiffness. Operational factors leading to the loss of image quality in dynamic atomic force microscopy are addressed, and guidelines for optimizing scan stability are proposed using a quantitative analysis based on system dynamical parameters and choice of feedback loop parameter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diffusive flux in a model of stochastically gated oxygen transport in insect respiration

Oxygen delivery to insect tissues is controlled by transport through a branched tubular network that is connected to the atmosphere by valve-like gates, known as spiracles. In certain physiological regimes, the spiracles appear to be randomly switching between open and closed states. Quantitative analysis of this regime leads a reaction-diffusion problem with stochastically switching boundary condition. We derive an expression for the diffusive flux at long times in this problem. Our approach starts with the derivation of the passage probability for a single particle that diffuses between a stochastically gated boundary, which models the opening and closing spiracle, and the perfectly absorbing boundary, which models oxygen absorption by the tissue. This passage probability is then used to derive an expression giving the diffusive flux as a function of the geometric parameters of the tube and characteristic time scales of diffusion and gate dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Kelvin-Helmholtz instability of boundary-layer plasmas in the kinetic regime

The dynamics of the Kelvin-Helmholtz instability are investigated in the kinetic, high-frequency regime with a novel, two-dimensional, mesh-free tree code. In contrast to earlier studies which focused on specially prepared equilibrium configurations in order to compare with fluid theory, a more naturally occurring plasma-vacuum boundary layer is considered here with relevance to both space plasma and linear plasma devices. Quantitative comparisons of the linear phase are made between the fluid and kinetic models. After establishing the validity of this technique via comparison to linear theory and conventional particle-in-cell simulation for classical benchmark problems, a quantitative analysis of the more complex magnetized plasma-vacuum layer is presented and discussed. It is found that in this scenario, the finite Larmor orbits of the ions result in significant departures from the effective shear velocity and width underlying the instability growth, leading to generally slower development and stronger nonlinear coupling between fast growing short-wavelength modes and longer wavelengths.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dependency of the Reynolds number on the water flow through the perforated tube

Safe and effective loading of nuclear reactor fuel assemblies demands qualitative and quantitative analysis of the relationship between the coolant temperature in the fuel assembly outlet, measured by the thermocouple, and the mean coolant temperature profile in the thermocouple plane position. It is not possible to perform the analysis directly in the reactor, so it is carried out using measurements on the physical model, and the CFD fuel assembly coolant flow models. The CFD models have to be verified and validated in line with the temperature and velocity profile obtained from the measurements of the cooling water flowing in the physical model of the fuel assembly. Simplified physical model with perforated central tube and its validated CFD model serve to design of the second physical model of the fuel assembly of the nuclear reactor VVER 440. Physical model will be manufactured and installed in the laboratory of the Institute of Energy Machines, Faculty of Mechanical Engineering of the Slovak University of Technology in Bratislava.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Synthesis of FeCoNi nanoparticles by galvanostatic technique

Soft magnetic nanoparticles of FeCoNi have been becoming interesting objects for many researchers due to its potential application in electronic devices. One of the most promising methods for material preparation is the electrodeposition which capable of growing nanoparticles alloy directly onto the substrate. In this paper, we report our electrodeposition studies on nanoparticles synthesis using galvanostatic electrodeposition technique. Chemical composition of the synthesized FeCoNi was successfully controlled through the adjustment of the applied currents. It is revealed that the content of each element, obtained from quantitative analysis using atomic absorption spectrometer (AAS), could be modified by the adjustment of current in which Fe and Co content decreased at larger applied currents, while Ni content increased. The nanoparticles of Co-rich FeCoNi and Ni-rich FeCoNi were obtained from sulphate electrolyte at the range of applied current investigated in this work. Broad diffracted peaks in the X-ray diffractograms indicated typical nanostructures of the solid solution of FeCoNi.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Experimental evaluation of the response of micro-channel plate detector to ions with 10s of MeV energies

The absolute calibration of a microchannel plate (MCP) assembly using a Thomson spectrometer for laser-driven ion beams is described. In order to obtain the response of the whole detection system to the particles’ impact, a slotted solid state nuclear track detector (CR-39) was installed in front of the MCP to record the ions simultaneously on both detectors. The response of the MCP (counts/particles) was measured for 5–58 MeV carbon ions and for protons in the energy range 2–17.3 MeV. The response of the MCP detector is non-trivial when the stopping range of particles becomes larger than the thickness of the detector. Protons with energies E ≳ 10 MeV are energetic enough that they can pass through the MCP detector. Quantitative analysis of the pits formed in CR-39 and the signal generated in the MCP allowed to determine the MCP response to particles in this energy range. Moreover, a theoretical model allows to predict the response of MCP at even higher proton energies. This suggests that in this regime the MCP response is a slowly decreasing function of energy, consistently with the decrease of the deposited energy. These calibration data will enable particle spectra to be obtained in absolute terms over a broad energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced information content for three-dimensional localization and tracking using the double-helix point spread function with variable-angle illumination epifluorescence microscopy

The signal-to-noise ratio (SNR) and three-dimensional localization precision of a double helix point spread function (DH-PSF) can be significantly improved by applying variable-angle illumination epifluorescence microscopy (VAI, also commonly known as “pseudo-TIRF” or “quasi-TIRF”). In this paper, we performed a quantitative analysis of the dependence of SNR and localization precision on the number of measured photons and the incident angle for static particles under both low (at a planar index-matched interface) and high (within a porous silica matrix) fluorescent background conditions. We found that under noisier imaging conditions, the SNR and localization precision obtained using VAI are up to fivefold and threefold greater, respectively, than those obtained using epi-illumination. Finally and moreover, we demonstrate that the combination of DH-PSF and VAI can significantly improve the accuracy of the measured diffusion coefficient for mobile particles, even at a relatively large distance (50 μm) from the boundary of the optical cell.

42 ENGINEERING↗

Thermal diffusivity determination using heterodyne phase insensitive transient grating spectroscopy

The elastic and thermal transport properties of opaque materials may be measured using transient grating spectroscopy (TGS) by inducing and monitoring periodic excitations in both reflectivity and surface displacement. The “phase grating” response encodes both properties of interest, but complicates quantitative analysis by convolving temperature dynamics with surface displacement dynamics. Hence, thermal transport characteristics are normally determined using the “amplitude grating” response to isolate the surface temperature dynamics. Yet, this signal character requires absolute heterodyne phase calibration and contains no elastic property information. Here, a method is developed by which phase grating TGS measurements may be consistently analyzed to determine thermal diffusivity with no prior knowledge of the expected properties. To demonstrate this ability, the wavelength-dependent 1D effective thermal diffusivity of pure germanium is measured using this type of response and found to be consistent with theoretical predictions made by solving the Boltzmann transport equation. This ability to determine the elastic and thermal properties from a single set of TGS measurements will be particularly advantageous for new in situ implementations of the technique being used to study dynamic materials systems.

36 MATERIALS SCIENCE↗

Swelling of individual nanodomains in hydrated block copolymer electrolyte membranes

Here, we examine the swelling of nanostructured block copolymer electrolytes immersed in liquid water. A series of sulfonated polystyrene-b-polyethylene-b-polystyrene (S-SES) membranes having the same nominal chemical composition but two different morphologies are prepared by systematic changes in processing. We start with a membrane comprising a mixture of homopolymer polystyrene (hPS) and a polystyrene-b-polyethylene-b-polystyrene (SES) copolymer. hPS is subsequently selectively removed from the membrane and the polystyrene domains are sulfonated to give S-SES membranes. The morphology of the membranes is controlled by controlling Φ v , the volume fraction of hPS in the blended membrane. The morphology of the membranes was studied by small angle X-ray scattering (SAXS), cryogenic scanning transmission electron microscopy (cryo-STEM), and cryogenic electron tomography. The overall domain swelling measured by SAXS decreases slightly at Φ v = 0.29; a crossover from lamellar to bicontinuous morphology is obtained at the same value of Φ v . The bicontinuous morphologies absorb more water than the lamellar morphologies. By contrast, the nanodomain swelling of the bicontinuous membrane (120%) is slightly less than that of the lamellar membrane (150%). Quantitative analysis of the STEM images and electron tomography was used to determine the swelling on the hydrophilic and hydrophobic domains due to exposure to water. The hydrophilic sulfonated polystyrene-rich domain spacing increases while the hydrophobic polyethylene domain spacing decreases when the membranes are hydrated. The extent of increase and decrease is not a strong function of Φ v .

36 MATERIALS SCIENCE↗

Shear strain-induced anisotropic domain evolution in mixed-phase BiFeO 3 epitaxial films

Understanding and controlling the domain evolution under external stimuli in multiferroic thin films is critical to realizing nano-electronic devices, including for non-volatile memory, data storage, sensors, and optoelectronics. In this article, we studied the shear-strain effect on the domain evolution with temperature in highly strained BiFeO 3 thin films on rhombohedral LaAlO 3 sub-strates using a high-resolution synchrotron X-ray diffraction three dimensional-reciprocal space mapping (3D-RSM) technique. The results revealed significant biaxial, anisotropic, evolution behaviors of the mixed-phase ( M C + R' / T' phases) BiFeO 3 ferro-electric domains along the in-plane [100] and [010] axes. These biaxial, anisotropic, evolution behaviors were attributed to the shear-strain-modulated transition pathways of the mixed-phase ferroelectric domains. This viewpoint was further verified in the BiFeO 3 /LaSrAlO 4 (001) system in which no anisotropic evolution behaviors of the mixed-phase domains were found. This work sheds light on the quantitative analysis of domain evolution in multi-domain systems and demonstrates that the shear-strain effect could act as an effective tool to manipulate the domain behavior and control novel functionalities of ferroelectric thin films.

36 MATERIALS SCIENCE↗

Impact of non-Maxwellian electron velocity distribution functions on inferred plasma parameters in collective Thomson scattering

Optical collective Thomson scattering provides precise density and temperature measurements in numerous plasma-physics experiments. The accuracy of such measurements depends on the core assumption that the underlying electron distribution functions in under-dense laser-produced plasmas are Maxwellian. A statistically based, quantitative analysis of the errors in the measured electron density and temperature is presented when synthetic data calculated using a non-Maxwellian electron distribution function is fit assuming a Maxwellian electron distribution. Such analysis can lead to errors of up to 50% in temperature and 30% in density, in the specific case of super-Gaussian distributions characteristic of inverse bremsstrahlung heating. Furthermore including the proper family of non-Maxwellian electron distribution functions, as a fitting parameter, in Thomson-scattering analysis removes the model-dependent errors in the inferred parameters at a minimal cost to the statistical uncertainty.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Curvature distribution and autocorrelations in elliptic cylinders and cones

Not all micro-vessels (MV) are traditionally circular and there are examples of elliptic cylindrical MVs in life sciences, particularly if projected with a slant. Similarly, certain biological structures, ferroelectric liquid crystals, aluminum oxide clusters and witherite crystallites’ crosssection appear to be elliptical cones. We studied the mean curvature (H) distribution of these elliptic morphological structures with geometric parameter such as eccentricity; e (ratio of semi-minor to semi-major axes) and a measure of how much diagonal section deviates from circularity and height (h) in case of cones. By means of topographical cues, we defined the curvature-curvature autocorrelation function (gk) and applied this notion to mean curvature (H) of circular and elliptical cylinders and cones. The Fourier transform of correlation function, i.e. “curvature factor” is analogous to “structure factor (or Patterson function)” in X-ray and neutron scattering intensity. It elucidates critically important information related to surface curvature fluctuation relevant to shape (geometry), network and phase transformation. The latter is induced by cells under mechanical stress, occurring in many soft systems (polymeric liquid crystals, foams, bubbles) and biological tissues, particularly cell walls of primary and branched vessels bed in microvasculature that distributes blood within tissue during hypertension and migraines. This perspective is useful in a sustained release of angiogenic/vasculogenic factors and relevant for precision medicine and engineered microvessels and tissues in vitro and in vivo extended cellular processes. The quantitative analysis carried out in this work facilitates our understanding of the mechanical mechanisms associated with thrombosis during surgery that typically occur in bent or stretched MVs due to microenvironment such as localized shear stresses and biochemical factors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reconstruction of the interatomic forces from dynamic scanning transmission electron microscopy data

We explore the possibility for reconstruction of the generative physical models describing interactions between atomic units in solids from observational electron microscopy data. In this work, scanning transmission electron microscopy (STEM) is used to observe the dynamic motion of Si atoms at the edge of monolayer graphene under continuous electron beam illumination. The resulting time-lapsed STEM images represent the snapshots of observed chemical states of the system. We use two approaches: potential of mean force calculation using a radial distribution function and a direct fitting of the graphene–Si interatomic pairwise potentials with force matching, to reconstruct the force fields in the materials. These studies lay the foundation for quantitative analysis of materials energetics from STEM data through the sampling of the metastable states in the chemical space of the system.

42 ENGINEERING↗

Effect of hydride vapor phase epitaxy growth conditions on the degree of atomic ordering in GaInP

We report a systematic study of CuPt-type ordering in hydride vapor phase epitaxy (HVPE)-grown Ga 0.5 In 0.5 P. Selected-area electron diffraction reveals ordering in samples grown on (001) GaAs substrates offcut toward (1$\overline{1}$1)B. The ordering is single-variant, occurring only on (1$\overline{1}$1)B planes and not on ($\overline{1}$11)B. Quantitative analysis of the order parameter by high-resolution x-ray diffraction (HRXRD) indicates that ordering increases with deposition temperature in samples grown at 600–700 °C with a constant gas-phase V/III ratio ~3. Ordering increases with V/III ratio in the range of 1.3–6.7 at a constant deposition temperature of 650°C. Photoluminescence measurements correlate the order parameter with Ga0.5In0.5P bandgap contraction, though the contraction is larger than expected based on the magnitude of order parameters measured by HRXRD. A possible reason for this discrepancy is that the photoluminescence emission occurs in the lower bandgap ordered domains, which are small and evenly dispersed throughout the material. We also show that the degree of ordering decreases with growth rate, disappearing at ~60 µm/h. The HVPE-grown material exhibits a generally weaker ordering than organometallic vapor phase epitaxy (OMVPE)-grown material, likely due to the moderate V/III ratios employed, in contrast to the V/III ratios in the 100s typical of OMVPE. However, the tendency for ordering to increase with V/III ratio suggests that the same dimer-induced stress mechanism used to explain the occurrence of ordering in OMVPE-grown material also applies to HVPE. The tendencies for ordering to increase with deposition temperature and decrease with growth rate show that kinetics limit the degree of ordering, also in agreement with OMVPE trends.

74 ATOMIC AND MOLECULAR PHYSICS↗

X-ray multi-probe data acquisition: A novel technique for laser pump x-ray transient absorption spectroscopy

We report the development and implementation of a novel data acquisition (DAQ) technique for synchrotron-based laser pump X-ray Transient Absorption (XTA) spectroscopy, called X-ray Multi-Probe DAQ (XMP DAQ). This technique utilizes high performance analog to digital converters and home-built software to efficiently measure and process the XTA signal from all x-ray pulses between laser excitations. XMP DAQ generates a set of time resolved x-ray absorption spectra at thousands of different pump–probe time delays simultaneously. Two distinct XMP DAQ schemes are deployed to accommodate different synchrotron storage ring filling patterns. Current Integration (CI) DAQ is a quasi-analog technique that implements a fitting procedure to extract the time resolved absorption intensity from the averaged fluorescence detector response. The fitting procedure eliminates issues associated with small drifts in the voltage baseline and greatly enhances the accuracy of the technique. Photon Counting (PC) DAQ is a binary technique that uses a time resolved histogram to calculate the XTA spectrum. While PC DAQ is suited to measure XTA data with closely spaced x-ray pulses (~10 ns) and a low count rate (<1 detected photon/pulse), CI DAQ works best for widely spaced pulses (tens of ns or greater) with a high count rate (>1 detected photon/pulse). XMP DAQ produces a two-dimensional XTA dataset, enabling efficient quantitative analysis of photophysical and photochemical processes from the sub-nanosecond timescale to 100 μs and longer.

47 OTHER INSTRUMENTATION↗