Search NASA⌕ Search

SEARCH · Search NASA

Results for “response surface methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Retrieval Algorithm for the Column CO2 Mixing Ratio from Pulsed Multi-Wavelength Lidar Measurements

The retrieval algorithm for the column mixing ratio of CO2 from the measurements of a pulsed multi-wavelength integrated path differential absorption (IPDA) lidar is described. The lidar samples the shape of the 1572.33 nm CO2 absorption line at 15 or 30 wavelengths. The algorithm uses a least-squares fit between the CO2 line shape computed from a layered 10 atmosphere model to that sampled by the lidar. In addition to the column average CO2 dry air mole fraction (XCO2), several other parameters are also solved simultaneously from the fit. These include the Doppler shift in the received laser signal wavelengths, the product of the surface reflectivity and atmospheric transmission and a linear trend in the lidar receiver’s spectral response. The algorithm can also be used to solve for the average water vapor mixing ratio, which causes a secondary absorption in the wings of the CO2 absorption line under high humidity conditions. The least-squares fit is linearized about the 15 expected XCO2 value which allows the use of a standard linear least-squares fitting method and software tools. The standard deviation of the retrieved XCO2 is obtained from covariance matrix of the fit. An averaging kernel is defined similarly to that used for passive trace-gas sounding. Examples are presented of using the algorithm to retrieve XCO2 from the measurements from NASA Goddard’s airborne CO2 Sounder lidar made at a constant altitude and during spiral-down maneuvers.

Xiaoli Sun↗

Bayesian Deep Learning for Segmentation for Autonomous Safe Planetary Landing

Hazard detection is critical for enabling autonomous landing on planetary surfaces. Current state-of-the-art methods leverage traditional computer vision approaches to automate the identification of safe terrain from input digital elevation models (DEMs). However, performance for these methods can degrade for input DEMs with increased sensor noise. In the last decade, deep learning techniques have been developed for various applications. Nevertheless, their applicability to safety-critical space missions has often been limited due to concerns regarding their outputs’ reliability. In response to these limitations, this paper proposes an application of the Bayesian deep learning segmentation method for hazard detection. The developed approach enables reliable, safe landing site detection by i) generating simultaneously a safety prediction map and its uncertainty map via Bayesian deep learning and semantic segmentation, and ii) using the uncertainty map to filter out the uncertain pixels in the prediction map so that the safe site identification is performed only based on the certain pixels (i.e., pixels for which the model is certain about its safety prediction). Experiments are presented with simulated data based on a Mars HiRISE digital terrain model by varying uncertainty threshold and noise levels to demonstrate the performance of the proposed approach.

Kento Tomita↗

A contactless in situ EFISH method for measuring electrostatic potential profile of semiconductor/electrolyte junctions

In photoelectrochemical cells, promising devices for directly converting solar energy into storable chemical fuels, the spatial variation of the electrostatic potential across the semiconductor–electrolyte junction is the key parameter that determines the cell performance. In principle, electric field induced second harmonic generation (EFISH) provides a contactless in situ spectroscopic tool to measure the spatial variation of electrostatic potential. However, the total second harmonic generation (SHG) signal contains the contributions of the EFISH signals of semiconductor space charge layer and the electric double layer, in addition to the SHG signal of the electrode surface. The interference of these complex quantities hinders their analysis. In this work, to understand and deconvolute their contributions to the total SHG signals, bias-dependent SHG measurements are performed on the rutile TiO2(100)–electrolyte junction as a function of light polarization and crystal azimuthal angle (angle of the incident plane relative to the crystal [001] axis). A quadratic response between SHG intensity and the applied potential is observed in both the accumulation and depletion regions of TiO2. The relative phase difference and amplitude ratio are extracted at selected azimuthal angles and light polarizations. At 0° azimuthal angle and s-in–p-out polarization, the SHG intensity minimum has the best match with the TiO2 flatband potential due to the orthogonal relative phase difference between bias-dependent and bias-independent SHG terms. We further measure the pH-dependent flatband potential and probe the photovoltage under open circuit conditions using the EFISH technique, demonstrating the capability of this contactless method for measuring electrostatic potential at semiconductor–electrolyte junctions.

Chemistry↗

High-Performance Scanning Acousto-Ultrasonic System

A high-performance scanning acousto-ultrasonic system, now undergoing development, is designed to afford enhanced capabilities for imaging microstructural features, including flaws, inside plate specimens of materials. The system is expected to be especially helpful in analyzing defects that contribute to failures in polymer- and ceramic-matrix composite materials, which are difficult to characterize by conventional scanning ultrasonic techniques and other conventional nondestructive testing techniques. Selected aspects of the acousto-ultrasonic method have been described in several NASA Tech Briefs articles in recent years. Summarizing briefly: The acousto-ultrasonic method involves the use of an apparatus like the one depicted in the figure (or an apparatus of similar functionality). Pulses are excited at one location on a surface of a plate specimen by use of a broadband transmitting ultrasonic transducer. The stress waves associated with these pulses propagate along the specimen to a receiving transducer at a different location on the same surface. Along the way, the stress waves interact with the microstructure and flaws present between the transducers. The received signal is analyzed to evaluate the microstructure and flaws. The specific variant of the acousto-ultrasonic method implemented in the present developmental system goes beyond the basic principle described above to include the following major additional features: Computer-controlled motorized translation stages are used to automatically position the transducers at specified locations. Scanning is performed in the sense that the measurement, data-acquisition, and data-analysis processes are repeated at different specified transducer locations in an array that spans the specimen surface (or a specified portion of the surface). A pneumatic actuator with a load cell is used to apply a controlled contact force. In analyzing the measurement data for each pair of transducer locations in the scan, the total (multimode) acousto-ultrasonic response of the specimen is utilized. The analysis is performed by custom software that extracts parameters of signals in the time and frequency domains. The computer hardware and software provide both real-time and postscan processing and display options. For example, oscilloscope displays of waveforms and power spectral densities are available in real time. Images can be computed while scanning continues. Signals can be digitally preprocessed and/or post-processed by filtering, windowing, time-segmenting, and running-waveform-averaging algorithms. In addition, the software affords options for off-line simulation of the waveform-data-acquisition and scanning processes. In tests, the system has been shown to be capable of characterizing microstructural changes and defects in SiC/SiC and C/SiC ceramic-matrix composites. Delaminations, variations in density, microstructural changes attributable to infiltration by silicon, and crack-space indications (defined in the next sentence) have been revealed in images formed from several time- and frequency-domain parameters of scanning acousto-ultrasonic signals. The crack-space indications were image features that were not revealed by other nondestructive testing methods and are so named because they turned out to mark locations where cracking eventually occurred.

Roth, Don↗

Enhancing the photovoltaic performance of CdTe/CdS solar cell via luminescent downshifting using K{sub 2}SiF{sub 6}:Mn{sup 4+} phosphors

The efficiency of CdTe/CdS solar cell can be significantly improved by using luminescent down-shifting material on their front surface. Taking this into account a red emitting phosphor K{sub 2}Si{sub 1-x}F{sub 6}:xMn{sup 4+} (x=10 to 25 mol %) has been synthesized through wet chemical method. The as-synthesized materials were characterized by powder x-ray diffraction (XRD) and photoluminescence (PL) techniques. The photoluminescence studies of K{sub 2}SiF{sub 6}:Mn{sup 4+} revealed enhancement in the emission intensity, when Mn{sup 4+} concentration was increased from 10 mol % to 25 mol %. This red emitting phosphor efficiently absorbs the photons typically in the region 300-500 nm and re-emits in the region where the photovoltaic device exhibits significantly better response. The results show the possibility of enhancing the photovoltaic conversion efficiency of CdTe thin film solar cell by modifying the absorption spectra and utilising the energy in the UV-blue part of the solar spectrum.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Density Functional Theory Study of the Energetics, Electronic Structure, and Core-Level Shifts of NO Adsorption on the Pt(111) Surface

In this work, we report a first-principles investigation of the energetics, structures, electronic properties, and core-level shifts of NO adsorption on the Pt(111) surface. Our calculations are based on density functional theory within the framework of the ultrasoft pseudopotential plane-wave and the all-electron projected augmented-wave methods. We found that at 0.25, 0.50, and 0.75 monolayer, NO adsorbs preferentially in the fcc, fcc+top, and fcc+top+hcp sites, respectively. The geometric parameters, adsorption energies, vibrational frequencies, and work-function changes are in good agreement with the experimental data. The interaction between NO and Pt(111) was found to follow a donation-back-donation process, in which the NO {sigma} states donate electrons to the substrate Pt d states, while the substrate Pt d states back donate to the NO {pi} states. Though there is an overall net charge transfer from the substrate to the NO adsorbate regardless of the adsorption sites and coverages, the spatial redistribution of the transferred electron is site dependent. The charge accumulation for NO in the top sites occurs closer to the surface than NO in the hollow sites, which results in the reduction of the Pt(111) surface work function for the top NO but an increase for the hollow NO. The core-level shifts of the topmost surface Pt atoms coordinated with top and hollow NO molecules at different coverages are in excellent agreement with experiments. In contrast, the N 1s core-level shifts between top and hollow NO ({approx}0.7 eV) deviated significantly from the zero shift found in experiments. Our analysis indicates that the difference may come from the thermal vibration and rotation of adsorbed NO on the Pt(111) surface.

36 MATERIALS SCIENCE↗

Parametric dependencies of resonant layer responses across linear, two-fluid, drift-MHD regimes

Non-axisymmetric magnetic fields arising in a tokamak either by external or internal perturbations can induce complex non-ideal MHD responses in their resonant surfaces while remaining ideally evolved elsewhere. This layer response can be characterized in a linear regime by a single parameter called the inner-layer Delta, which enables outer-layer matching and the prediction of torque balance to non-linear island regimes. Here, we follow strictly one of the most comprehensive analytic treatments including two-fluid and drift MHD effects and keep the fidelity of the formulation by incorporating the numerical method based on the Riccati transformation when quantifying the inner-layer Delta. The proposed scheme reproduces not only the predicted responses in essentially all asymptotic regimes but also with continuous transitions as well as improved accuracies. In particular, the Delta variations across the inertial regimes with viscous or semi-collisional effects have been further resolved, in comparison with additional analytic solutions. The results imply greater shielding of the electromagnetic torque at the layer than what would be expected by earlier work when the viscous or semi-collisional effects can compete against the inertial effects, and also due to the intermediate regulation by kinetic Alfven wave resonances as rotation slows down. These are important features that can alter the nonaxisymmetric plasma responses including the field penetration by external fields or island seeding process in rotating tokamak plasmas.

MHD instability↗

Microfluidic molecular assay platform for the detection of miRNAs, mRNAs, proteins, and post-translational modifications at single-cell resolution

In this study, cell signaling is a dynamic and complex process. A typical signaling pathway may begin with activation of cell surface receptors, leading to activation kinase cascade that culminates in induction of mRNA and non-coding miRNA production in the nucleus, followed by modulation of mRNA expression by miRNAs in the cytosol, and end with production of proteins in response to the signaling pathway. Signaling pathways involve proteins, miRNA, and mRNAs, along with various forms of transient post-translational modifications, and detecting each type of signaling molecule requires categorically different sample preparation methods such as Western blotting for proteins, PCR for nucleic acids, and flow cytometry for post-translational modifications. Since we know that cells in populations behave heterogeneously1, especially in the cases of stem cells, cancer, and hematopoiesis, there is need for a new technology that provides capability to detect and quantify multiple categories of signaling molecules in intact single cells to provide a comprehensive view of the cell’s physiological state. In this technical brief, we describe our microfluidic platform with a portfolio of customized molecular assays that can detect nucleic acids, proteins, and post-translational modifications in single intact cells with >95% reduction in reagent requirement in under 8 hours.

42 ENGINEERING↗

EGS Collab Experiment 2: Continuous Broadband Seismic Waveform Data

Two broadband seismometers were installed on the 4100 level and recorded for the duration of EGS Collab Experiment #2. Inspired by published data from similar instruments installed in the Aspo Hard Rock Lab, these long-period instruments aimed to measure the tilting of the drift in response to the injection of fluid into the testbed. One instrument was installed underneath the wellheads in Site A (aka the "battery" alcove) and the other was installed along the east wall of the drift, south of Site B. Due to the feet of gravel (ballast) laid along the floor of the drift, we were unable to anchor the sensors directly to the rock. As a result, the coupling of the sensors to the experiment rock volume is likely poor. In addition, there are a number of noise sources that complicate the interpretation of the data. For example, sensor BBB is installed adjacent (within 3 ft) to the rail line that runs towards the Ross shaft. Trains (motors) run along this line almost daily and produce a large signal in these data. Careful extraction of periods of interest, as well as filtering for specific signals, is necessary. The sensors are Nanometrics Trillium Compact Posthole seismometers, sensitive down to 120 seconds period. They were installed as close to the drift wall and as deep as we could manually excavate (only about 1 ft or so). The holes were leveled with sand and the sensors were placed on a paver before backfilling with sand. The hole was then covered by a bucket filled with insulation to improve the sensor's isolation from daily temperature variations, which are minor but present due to drift ventilation from the surface. Data were recorded on Nanometrics Centaur digitizers at 100 Hz. The full response information is available in the StationXML file provided here, or by querying the sensors through the IRIS DMC (see links below). These instruments were provided free of charge through the IRIS PASSCAL instrument center. The network code is XP and the station codes are BBA and BBB. The waveform data can be queried through the IRIS FDSN server using any method the user likes. One convenient option is to use the Obspy python package: https://docs.obspy.org/packages/obspy.clients.fdsn.html

15 GEOTHERMAL ENERGY↗

Electrostatic Charging of Polymers by Particle Impact at Low Pressures

Studies of the electrostatic interaction between micrometer-sized particles and polymer surfaces are of great interest to NASA's planetary exploration program. The unmanned landing missions to Mars planned for this decade as well as the possible manned missions that might take place during the second decade of this century require a better understanding of the electrostatic response of the materials used in landing crafts and equipment when exposed to wind-blown dust or to surface dust and sand particles. We report on preliminary experiments designed to measure the electrostatic charge developed on five polymer surfaces as they are impacted simultaneously by Mars simulant particles less than 5 micrometers in diameter moving at 20 m/s. Experiments were performed in a CO2 atmosphere at 10 mbars of pressure using a particle delivery method that propels the particles with contact. Experiments were also performed in dry air at atmospheric pressures using a pressurized particle delivery system. The five polymer surfaces, commonly used in space applications, were chosen so that they span the triboelectric series.

Calle, Carlos I.↗

Pulmonary and Systemic Immune Response to Chronic Lunar Dust Inhalation

Background: Due to millennia of meteorite impact with virtually no erosive effects, the surface of the Moon is covered by a layer of ultra‐fine, reactive Lunar dust. Very little is known regarding the toxicity of Lunar dust on human physiology. Given the size and electrostatic characteristics of Lunar dust, countermeasures to ensure non‐exposure of astronauts will be difficult. To ensure astronaut safety during any future prolonged Lunar missions, it is necessary to establish the effect of chronic pulmonary Lunar dust exposure on all physiological systems. Methods: This study assessed the toxicity of airborne lunar dust exposure in rats on pulmonary and system immune system parameters. Rats were exposed to 0, 20.8, or 60.8 mg/m3 of lunar dust (6h/d; 5d/wk) for up to 13 weeks. Sacrifices occurred after exposure durations of 1day, 7 days, 4 weeks and 13 weeks post‐exposure, when both blood and lung lavage fluid were collected for analysis. Lavage and blood assays included leukocyte distribution by flow cytometry, electron/fluorescent microscopy, and cytokine concentration. Cytokine production profiles following mitogenic stimulation were performed on whole blood only. Results: Untreated lavage fluid was comprised primarily of pulmonary macrophages. Lunar dust inhalation resulted in an influx of neutrophils and lymphocytes. Although the percentage of lymphocytes increased, the T cell CD4:CD8 ratio was unchanged. Cytokine analysis of the lavage fluid showed increased levels of IL‐1b and TNFa. These alterations generally persisted through the 13 week sampling. Blood analysis showed few systemic effects from the lunar dust inhalation. By week 4, the peripheral granulocyte percentage was elevated in the treated rats. Plasma cytokine levels were unchanged in all treated rats compared to controls. Peripheral blood analysis showed an increased granulocyte percentage and altered cytokine production profiles consisting of increased in IL‐1b and IL‐6, and decreased IL‐2 production. Conclusion: Lunar dust inhalation results in significant lung inflammation, and some systemic effects, that does not resolve through 13 weeks. Lunar dust may therefore represent a crew health risk during sortie or long‐duration Lunar missions.

Crucian, Brian↗

Safety and Efficacy of Y-90 Radioembolization After Prior Major Hepatic Resection

PurposeTo evaluate the safety and efficacy of yttrium-90 radioembolization (RE) following left or right hepatic lobectomy.Materials and MethodsBetween 2011 and 2016, 15 patients underwent RE with Y90-resin microspheres following right (8/15) or left (7/15) hepatic lobectomy. In eight patients, the whole liver remnant was treated during a single session, whereas the remaining seven patients received up to 3 selective RE at 1- to 2-month intervals. The administered patient activity was calculated based on the body surface area (BSA) method in all cases. In addition, CT-based volumetry of the liver remnant was performed and used to calculate the absorbed liver dose. Patient follow-up data were retrospectively analyzed regarding signs of radioembolization-induced liver disease (REILD), defined as occurrence of bilirubin >3.0 mg/dl and ascites within 1–2 months after treatment without tumor progression or bile duct occlusion.ResultsThe mean volume of the liver remnant was 1.471 ± 341 ml, the mean administered amount of activity amounted to 1.31 ± 0.74 GBq, and the calculated mean absorbed dose was 42.8 ± 20.6 Gy. The early response to treatment was generally positive, with only one patient showing signs of progressive disease of the treated area on follow-up examinations within the first 2 months post-RE. None of the 15 patients developed a REILD.ConclusionY-90 radioembolization following extended hepatic lobectomy appears to be safe and effective. Although the standard BSA-based dosing seems to suffice to avoid REILD, it results in quite variable liver doses due to variable hypertrophy of the liver remnant post-hepatectomy. Level of Evidence: Level IV, Case series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical properties of water desalination and wastewater treatment membranes

Applications of membrane technology in water desalination and wastewater treatment have increased significantly in the past fewdecades due to itsmany advantages over otherwater treatment technologies.Water treatment membranes provide high flux and contaminant rejection ability and require good mechanical strength and durability. Thus, assessing the mechanical properties of water treatment membranes is critical not only to their design, but also for studying their failure mechanisms, including the surface damage, mechanical and chemical ageing, delamination and loss of dimensional stability of the membranes. The various experimental techniques to assess themechanical properties ofwastewater treatment and desalinationmembranes are reviewed. Uniaxial tensile test, bending test, dynamic mechanical analysis, nanoindentation and bursting tests are the most widely used mechanical characterization methods for water treatment membranes. Mechanical degradations induced by fouling, chemical cleaning as well as membrane delamination are then discussed. Moreover, in order to study the membranesmechanical responses under similar loading conditions, the stress-state of the membranes are analyzed and advanced mechanical testing approaches are proposed. Lastly, some perspectives are highlighted to study the structure-properties relationship for wastewater treatment and water desalination membranes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Prediction of the thermal-hydraulic-mechanical response of a geological repository at large scale and sensitivity analyses

To better understand the Thermal-Hydraulic-Mechanical (THM) response of the rock caused by the high-level radioactive waste (HLW) released heat in the Callovo-Oxfordian formation (COx) in the near-field and far-field areas, a series of coupled THM modelling is performed. This study presents a case study based on the French geological repository for HLW (Cigéo project) to better assess modelling of deep geological repositories (DGR) within the DECOVALEX-2019 framework. In this study, the proposed coupled THM model, implemented in the platform of COMSOL, is validated by comparing the modelled THM results for a point heat source in an infinite rock mass with an analytical solution. It is also validated by comparing its thermal component for the Base Case with accurate results calculated using another numerical method. To shorten the calculation time, the DGR is modelled using six cuboid blocks representing 162 HLW cells and only six central HLW cells of interest modelled in detail. This simplification is validated. This model can easily be used to model not only the near-field THM response of the rock but also the far-field THM response. The influence of the boundary conditions applied on the gallery wall, HLW cell walls, and external surfaces of the model and the influence of different vertical dimensions of the geometry are studied. The sensitivity analyses of the THM parameters of COx on the THM response at different locations are performed. Finally, the influence of using a 2-dimensional (2D) model to represent a 3-dimensional (3D) repository is also investigated.

58 GEOSCIENCES↗

Mesoporous Thin Film Architectures: Addressing Material Demands through Molecular Self-Assembly

Mesoporous thin films spark interest across a wide range of disciplines due to their tunable nanostructures, large internal surface areas, and strong compatibility with planar optical, electronic, and microfluidic devices. While attention in the porous materials community has shifted toward macroporous or disordered nanoporous systems, a resurgence in mesoporous thin film research is underway, driven by new molecular self-assembly methods, advanced materials chemistry, and improved characterization techniques. The integration of high-χN block copolymer design, kinetically persistent micelle templating, and postdeposition processing protocols now allows control over structural parameters such as pore size, wall thickness, porosity, and connectivity. These advances have overcome many of the thermodynamic and processing constraints that previously limited widespread adoption. Rather than serving only as high-surface-area supports, mesoporous thin films are engineered as active interfaces where responsive chemistries and nanoscale confinement act in tandem. Embedding switchable ligands, thermoresponsive polymers, redox mediators, or ion-selective groups directly within the pore walls enables real-time control over transport, optical, and electrochemical properties. These capabilities open up new directions in adaptive coatings, gated membranes, and fast-response biosensors. To further expand their functional scope, mesoporous films are integrated into hierarchical and multicomponent architectures. Techniques such as triblock terpolymer templating, crack-directed assembly, and nanoimprint lithography allow for control over spatial organization on the micron and submicron scale and pore system orientation. This enables programmable anisotropy, enhanced molecular diffusion, and wavelength-selective photonic behavior, essential for next-generation sensing, catalysis, and energy applications. Such structural and functional complexity requires equally sophisticated characterization. Multimodal and in situ techniques can track material dynamics under operational conditions. Recent progress includes extended-range ellipsometric porosimetry (EP) for hierarchical architectures, vacuum EP for interface energetics, time-resolved EP for diffusion kinetics, and correlative AFM-SAXS mapping. The introduction of advanced neutron-based spectroscopies, particularly quasielastic neutron scattering (QENS), promises to provide real-time access to ion transport dynamics and segmental motion under nanoscale confinement, offering a path toward deeper mechanistic understanding of structure-performance correlations in mesoporous systems. This Account reflects the technical advances made and the interdisciplinary collaborations that have shaped our collective vision. The particular dimensions of mesopores enable us to subtly tune interactions at the molecular, interfacial, and mesoscopic levels that permit us to harness nanoconfinement. What emerges is a versatile, modular platform capable of chemical gating, energy transduction, and sensing with a level of tunability unmatched by other porous materials. We highlight critical challenges including the need for more robust large-area processing, a deeper understanding of dynamic behavior under cycling, and better integration with device-level architectures. Our strategies support the transition of mesoporous thin films into active high-performance components in next-generation energy, environmental, and biomedical systems.

oxides↗

High-performance piezoelectric composites via β phase programming

Polymer-ceramic piezoelectric composites, combining high piezoelectricity and mechanical flexibility, have attracted increasing interest in both academia and industry. However, their piezoelectric activity is largely limited by intrinsically low crystallinity and weak spontaneous polarization. Here, we propose a Ti 3 C 2 T x MXene anchoring method to manipulate the intermolecular interactions within the all-trans conformation of a polymer matrix. Employing phase-field simulation and molecular dynamics calculations, we show that OH surface terminations on the Ti 3 C 2 T x nanosheets offer hydrogen bonding with the fluoropolymer matrix, leading to dipole alignment and enhanced net spontaneous polarization of the polymer-ceramic composites. We then translated this interfacial bonding strategy into electrospinning to boost the piezoelectric response of samarium doped Pb (Mg1/3Nb 2/3 )O 3 -PbTiO 3 /polyvinylidene fluoride composite nanofibers by 160% via Ti 3 C 2 T x nanosheets inclusion. With excellent piezoelectric and mechanical attributes, the as-electrospun piezoelectric nanofibers can be easily integrated into the conventional shoe insoles to form a foot sensor network for all-around gait patterns monitoring, walking habits identification and Metatarsalgi prognosis. This work utilizes the interfacial coupling mechanism of intermolecular anchoring as a strategy to develop high-performance piezoelectric composites for wearable electronics.

36 MATERIALS SCIENCE↗

Detection of antimicrobial resistance genes associated with the International Space Station environmental surfaces

Antimicrobial resistance (AMR) is a global health issue. In an effort to minimize this threat to astronauts, who may be immunocompromised and thus at a greater risk of infection from antimicrobial resistant pathogens, a comprehensive study of the ISS “resistome’ was conducted. Using whole genome sequencing (WGS) and disc diffusion antibiotic resistance assays, 9 biosafety level 2 organisms isolated from the ISS were assessed for their antibiotic resistance. Molecular analysis of AMR genes from 24 surface samples collected from the ISS during 3 different sampling events over a span of a year were analyzed with Ion AmpliSeq™ and metagenomics. Disc diffusion assays showed that Enterobacter bugandensis strains were resistant to all 9 antibiotics tested and Staphylococcus haemolyticus being resistant to none. Ion AmpliSeq™ revealed that 123 AMR genes were found, with those responsible for beta-lactam and trimethoprim resistance being the most abundant and widespread. Using a variety of methods, the genes involved in antimicrobial resistance have been examined for the first time from the ISS. Lastly, this information could lead to mitigation strategies to maintain astronaut health during long duration space missions when return to Earth for treatment is not possible.

59 BASIC BIOLOGICAL SCIENCES↗

Solid-state synthesis of UV-plasmonic Cr2N nanoparticles

Materials that exhibit plasmonic response in the UV region can be advantageous for many applications, such as biological photodegradation, photocatalysis, disinfection, and bioimaging. Transition metal nitrides have recently emerged as chemically and thermally stable alternatives to metal-based plasmonic materials. However, most free-standing nitride nanostructures explored so far have plasmonic responses in the visible and near-IR regions. Herein, we report the synthesis of UV-plasmonic Cr2N nanoparticles using a solid-state nitridation reaction. The nanoparticles had an average diameter of 9 ± 5 nm and a positively charged surface that yields stable colloidal suspension. The particles were composed of a crystalline nitride core and an amorphous oxide/oxynitride shell whose thickness varied between 1 and 7 nm. Calculations performed using the finite element method predicted the localized surface plasmon resonance (LSPR) for these nanoparticles to be in the UV-C region (100–280 nm). While a distinctive LSPR peak could not be observed using absorbance measurements, low-loss electron energy loss spectroscopy showed the presence of surface plasmons between 80 and 250 nm (or ∼5 to 15 eV) and bulk plasmons centered around 50–62 nm (or ∼20 to 25 eV). Plasmonic coupling was also observed between the nanoparticles, resulting in resonances between 250 and 400 nm (or ∼2.5 to 5 eV).

Chemistry↗