Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

FESTR, Version 0.x

FESTR is a modeling tool for calculating spectroscopic-quality synthetic outputs (e.g., spectra and images) based on (in general) the time evolutions of 3-D spatial distributions of materials characterized by their chemical composition, temperature, and density conditions. FESTR performs raytracing across unstructured meshes, builds intrinsic optical properties of mixed materials by performing equation-of-state lookups in external data, and then solves the radiation-transport equation along rays to obtain emergent time and space resolved synthetic spectra. These results can be further processed into time and/or space integrated spectra, as well as into spectral-band-integrated synthetic images, radiated power histories, and total radiated energy values. FESTR is also applicable to spatial reconstructions of material properties via the analysis of experimental data.

Hakel, Peter↗

Micro-CT Imaging of Rat Bone and Lumber Vertebra using Synchrotron Radiation

Micro-tomographic imaging with a spatial resolution on the micrometer scale offers owes a high potential to perform certain types of measurements that were not feasible with other techniques or conventional laboratory methods. The synchrotron X-ray source gives substantial advantages because of its high brilliance and continuous X-ray spectrum. Based on this, visualized the microstructure of rat bone and lumber vertebra was visualized using 20, 25 and 30 keV synchrotron X-rays. We utilized the data which was acquired at different energies for multi-model imaging and to estimate the Ca/P ratio. Up to now there has been no research carried out using these images for the estimation of the calcium content, with synchrotron X-rays. The results are based on the analysis of images and gray values obtained at different energies. We introduce this new method in order to measure the calcium content by means of high resolution synchrotron micro-CT.

60 APPLIED LIFE SCIENCES↗

Library based x-ray scatter correction for dedicated cone beam breast CT

Purpose: The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. Methods: The authors precompute a scatter library on simplified breast models with different sizes using the GEANT4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular/adipose tissue mixture. For scatter correction on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide range of breast sizes representing about 95% of general population. Spatial nonuniformity (SNU) and contrast to signal deviation ratio (CDR) were used as metrics for evaluation. Results: Since the time-consuming MC simulation for library generation is precomputed, the authors’ method efficiently corrects for scatter with minimal processing time. Furthermore, the authors find that a scatter library on a simple breast model with only one input parameter, i.e., the breast diameter, sufficiently guarantees improvements in SNU and CDR. For the 15 clinical datasets, the authors’ method reduces the average SNU from 7.14% to 2.47% in coronal views and from 10.14% to 3.02% in sagittal views. On average, the CDR is improved by a factor of 1.49 in coronal views and 2.12 in sagittal views. Conclusions: The library-based scatter correction does not require increase in radiation dose or hardware modifications, and it improves over the existing methods on implementation simplicity and computational efficiency. As demonstrated through patient studies, the authors’ approach is effective and stable, and is therefore clinically attractive for CBBCT imaging.

60 APPLIED LIFE SCIENCES↗

Subsurface spectroscopy of heterogeneous materials using optical wavefront shaping

Plastic-bonded explosives and propellants consist of energetic molecular crystals embedded in a polymer matrix that also includes additives, such as taggants, plasticizers, grit, antioxidants, etc. Furthermore, this heterogeneous composition renders these materials optically opaque, limiting optical characterization techniques (e.g., Raman spectroscopy) to probing chemical reactions at the sur-face. However, many reactions of interest are believed to occur inside the material where current optical techniques can not probe. To address this challenge, we have developed a new optical technique that utilizes feedback assisted wavefront shaping (using spatial light modulators) to focus probe light inside a heterogeneous material, such that we can perform subsurface spectroscopy. Recently, we demonstrated this technique by monitoring subsurface photodegradation and thermal degradation of Eu-doped molecular crystals using both fluorescence and Raman spectroscopy. Based off these successes we are now looking into improvements to this technique to allow for greater time resolution, including replacing our spatial light modulators with fast digital mirror devices, using ns optical phase conjugation, and self-healing optical beams.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A computational modeling framework for pre-clinical evaluation of cardiac mapping systems

There are a variety of difficulties in evaluating clinical cardiac mapping systems, most notably the inability to record the transmembrane potential throughout the entire heart during patient procedures which prevents the comparison to a relevant “gold standard”. Cardiac mapping systems are comprised of hardware and software elements including sophisticated mathematical algorithms, both of which continue to undergo rapid innovation. The purpose of this study is to develop a computational modeling framework to evaluate the performance of cardiac mapping systems. The framework enables rigorous evaluation of a mapping system’s ability to localize and characterize (i.e., focal or reentrant) arrhythmogenic sources in the heart. The main component of our tool is a library of computer simulations of various dynamic patterns throughout the entire heart in which the type and location of the arrhythmogenic sources are known. Our framework allows for performance evaluation for various electrode configurations, heart geometries, arrhythmias, and electrogram noise levels and involves blind comparison of mapping systems against a “silver standard” comprised of computer simulations in which the precise transmembrane potential patterns throughout the heart are known. A feasibility study was performed using simulations of patterns in the human left atria and three hypothetical virtual catheter electrode arrays. Activation times (AcT) and patterns (AcP) were computed for three virtual electrode arrays: two basket arrays with good and poor contact and one high-resolution grid with uniform spacing. The average root mean squared difference of AcTs of electrograms and those of the nearest endocardial action potential was less than 1 ms and therefore appears to be a poor performance metric. In an effort to standardize performance evaluation of mapping systems a novel performance metric is introduced based on the number of AcPs identified correctly and those considered spurious as well as misclassifications of arrhythmia type; spatial and temporal localization accuracy of correctly identified patterns was also quantified. This approach provides a rigorous quantitative analysis of cardiac mapping system performance. Proof of concept of this computational evaluation framework suggests that it could help safeguard that mapping systems perform as expected as well as provide estimates of system accuracy.

59 BASIC BIOLOGICAL SCIENCES↗

Statistical Behavior of Formation Process of Magnetic Vortex State in Ni80Fe20 Nanodisks

Magnetic vortices in magnetic nanodots, which are characterized by an in-plane (chirality) and an out-of-plane (polarity) magnetizations, have been intensively attracted because of their high potential for technological application to data storage and memory scheme as well as their scientific interest for an understanding of fundamental physics in magnetic nanostructures. Complete understanding of the formation process of vortex state in magnetic vortex systems is very significant issue to achieve storage and memory technologies using magnetic vortices and understand intrinsic physical properties in magnetic nanostructures. In our work, we have statistically investigated the formation process of vortex state in permalloy (Py, Ni{sub 80}Fe{sub 20}) nanodisks through the direct observation of vortex structure utilizing a magnetic transmission soft X-ray microscopy (MTXM) with a high spatial resolution down to 20 nm. Magnetic imaging in Py nanodots was performed at the Fe L{sub 3} (707 eV) absorption edge. Figure 1 shows in-plane and out-of-plane magnetic components observed in 40 nm thick nanodot arrays with different dot radius of r = 500 and 400 nm, respectively. Vortex chirality, either clockwise (CW) or counter-clockwise (CCW), and polarity, either up or down, are clearly visible in both arrays. To investigate the statistical behavior in formation process of the vortex state, the observation of vortex structure at a remanant state after saturation of nanodots by an external magnetic field of 1 kOe has been repeatedly performed over 100 times for each array. The typical MTXM images of vortex chirality taken in two successive measurements together with their overlapped images in nanodot arrays of r = 500 and 400 nm are displayed in Fig. 2. Within the statistical measurement, the formation process of chirality of either CW or CCW is quite stochastic in each nanodot. Similar behavior is also witnessed in the formation of vortex polarity observed in consecutive experiments of the same arrays. Interestingly, a particular selectivity between the circulation sense of chirality and orientation sense of polarity for each other is found in the formation process of vortex state despite of their respective stochastic generation in repeated measurements. Dzyaloshinskii-Moriya (D-M) interaction in magnetic nanodisks, which is inevitably generated due to the breaking of inversion symmetry at surface/interface in magnetic thin layers, is mainly responsible for the experimentally witnessed selectivity between chirality and polarity in a formation of vortex structure.

36 MATERIALS SCIENCE↗

A new multi-energy neutrino radiation-hydrodynamics code in full general relativity and its application to the gravitational collapse of massive stars

We present a new multi-dimensional radiation-hydrodynamics code for massive stellar core-collapse in full general relativity (GR). Employing an M1 analytical closure scheme, we solve spectral neutrino transport of the radiation energy and momentum based on a truncated moment formalism. Regarding neutrino opacities, we take into account a baseline set in state-of-the-art simulations, in which inelastic neutrino–electron scattering, thermal neutrino production via pair annihilation, and nucleon–nucleon bremsstrahlung are included. While the Einstein field equations and the spatial advection terms in the radiation-hydrodynamics equations are evolved explicitly, the source terms due to neutrino–matter interactions and energy shift in the radiation moment equations are integrated implicitly by an iteration method. To verify our code, we first perform a series of standard radiation tests with analytical solutions that include the check of gravitational redshift and Doppler shift. A good agreement in these tests supports the reliability of the GR multi-energy neutrino transport scheme. We then conduct several test simulations of core-collapse, bounce, and shock stall of a 15M{sub ⊙} star in the Cartesian coordinates and make a detailed comparison with published results. Our code performs quite well to reproduce the results of full Boltzmann neutrino transport especially before bounce. In the postbounce phase, our code basically performs well, however, there are several differences that are most likely to come from the insufficient spatial resolution in our current 3D-GR models. For clarifying the resolution dependence and extending the code comparison in the late postbounce phase, we discuss that next-generation Exaflops class supercomputers are needed at least.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and characterization of a spatially distributed multibeam field emission x-ray source for stationary digital breast tomosynthesis

Digital breast tomosynthesis (DBT) is a limited angle computed tomography technique that can distinguish tumors from its overlying breast tissues and has potentials for detection of cancers at a smaller size and earlier stage. Current prototype DBT scanners are based on the regular full-field digital mammography systems and require partial isocentric motion of an x-ray tube over certain angular range to record the projection views. This prolongs the scanning time and, in turn, degrades the imaging quality due to motion blur. To mitigate the above limitations, the concept of a stationary DBT (s-DBT) scanner has been recently proposed based on the newly developed spatially distributed multibeam field emission x-ray (MBFEX) source technique using the carbon nanotube. The purpose of this article is to evaluate the performance of the 25-beam MBFEX source array that has been designed and fabricated for the s-DBT system. The s-DBT system records all the projection images by electronically activating the multiple x-ray beams from different viewing angles without any mechanical motion. The configuration of the MBFEX source is close to the published values from the Siemens Mammomat system. The key issues including the x-ray flux, focal spot size, spatial resolution, scanning time, beam-to-beam consistency, and reliability are evaluated using the standard procedures. In this article, the authors describe the design and performance of a distributed x-ray source array specifically designed for the s-DBT system. They evaluate the emission current, current variation, lifetime, and focal spot sizes of the source array. An emission current of up to 18 mA was obtained at 0.5x0.3 mm effective focal spot size. The experimentally measured focal spot sizes are comparable to that of a typical commercial mammography tube without motion blurring. Trade-off between the system spatial resolution, x-ray flux, and scanning time are also discussed. Projection images of a breast phantom were collected using the x-ray source array from 25 different viewing angles without motion. These preliminary results demonstrate the feasibility of the proposed s-DBT scanner. The technology has the potential to increase the resolution and reduce the imaging time for DBT. With the present design of 25 views, they demonstrated experimentally the feasibility of achieving 11 s scanning time at full detector resolution with 0.5x0.3 mm source resolution without motion blur. The flexibility in configuration of the x-ray source array will also allow system designers to consider imaging geometries that are difficult to achieve with the conventional single-source rotating approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Security proof of practical quantum key distribution with detection-efficiency mismatch

Quantum key distribution (QKD) protocols with threshold detectors are driving high-performance QKD demonstrations. The corresponding security proofs usually assume that all physical detectors have the same detection efficiency. However, the efficiencies of the detectors used in practice might show a mismatch depending on the manufacturing and setup of these detectors. A mismatch can also be induced as the different spatial-temporal modes of an incoming signal might couple differently to a detector. Here we develop a method that allows to provide security proofs without the usual assumption. Our method can take the detection-efficiency mismatch into account without having to restrict the attack strategy of the adversary. Especially, we do not rely on any photon-number cutoff of incoming signals such that our security proof is directly applicable to practical situations. We illustrate our method for a receiver that is designed for polarization encoding and is sensitive to a number of spatial-temporal modes. In our detector model, the absence of quantum interference between any pair of spatial-temporal modes is assumed. For a QKD protocol with this detector model, we can perform a security proof with characterized efficiency mismatch and without photon-number cutoff assumption. Our method also shows that in the absence of efficiency mismatch in our detector model, the key rate increases if the loss due to detection inefficiency is assumed to be outside of the adversary's control, as compared to the view where for a security proof this loss is attributed to the action of the adversary.

97 MATHEMATICS AND COMPUTING↗

Strategic Environmental Assessment in Germany - Practice and open questions

Eight years after the enactment of the EU Strategic Environmental Assessment Directive (2001/42/EC) () it is time to investigate where and how SEA are being implemented in Germany in order to find out open questions and research needs. In this study, we analysed in which planning types SEA are common practice, and where can deficits be identified, and to what extent differences occur between spatial and sectoral planning with respect to carrying out SEA. Pressing challenges in performing SEA as well as open questions are addressed such as the handling of cumulative effects and the interrelationships between the environmental factors, and how the monitoring of environmental effects is considered by the practitioners. The results show that SEA is well implemented in local land-use planning, regional planning, and in local landscape planning, while the implementation in sectoral planning varies widely. The SEA in clean air planning is looked at in more detail, because this is discussed controversially in the specialist field, and obstacles against SEA are identified in this field. Finally some new topics are addressed for which solutions in spatial and environmental planning including SEA must be found, e.g. the consideration of biological diversity and the potential role of SEA in climate change. A European study on the identified open questions and their handling in different contexts and countries may allow for a qualitative amendment in practice.

54 ENVIRONMENTAL SCIENCES↗

WE-DE-BRA-06: Evaluation of the Imaging Performance of a Novel Water-Equivalent EPID

Purpose: To evaluate the megavoltage imaging performance of a novel, water-equivalent electronic portal imaging device (EPID) developed for simultaneous imaging and dosimetry applications in radiotherapy. Methods: A novel EPID prototype based on active matrix flat panel imager technology has been developed by our group and previously reported to exhibit a water-equivalent dose response. It was constructed by replacing all components above the photodiode detector in a standard clinical EPID (including the copper plate and phosphor screen) with a 15 × 15 cm{sup 2} array of plastic scintillator fibers. Individual fibers measured 0.5 × 0.5 × 30 mm{sup 3}. Spatial resolution was evaluated experimentally relative to that of a standard EPID with the thin slit technique to measure the modulation transfer function (MTF) for 6 MV x-ray beams. Monte Carlo (MC) EPID models were used to benchmark simulated MTFs against the measurements. The zero spatial frequency detective quantum efficiency (DQE(0)) was simulated for both EPID configurations and a preliminary optimization of the prototype was performed by evaluating DQE(0) as a function of fiber length up to 50 mm. Results: The MC-simulated DQE(0) for the prototype EPID configuration was ∼7 times greater than that of the standard EPID. The prototype’s DQE(0) also increased approximately linearly with fiber length, from ∼1% at 5 mm length to ∼11% at 50 mm length. The standard EPID MTF was greater than the prototype EPID’s for all spatial frequencies, reflecting the trade off between x-ray detection efficiency and spatial resolution with thick scintillators. Conclusion: This study offers promising evidence that a water-equivalent EPID previously demonstrated for radiotherapy dosimetry may also be used for radiotherapy imaging applications. Future studies on optimising the detector design will be performed to develop a next-generation prototype that offers improved megavoltage imaging performance, with the aim to at least match that of current clinical EPIDs. Funding for this project was provided by an Australian Research Council Linkage Project grant (2015) between The University of Sydney, South Western Sydney Local Health District and Perkin-Elmer Pty Ltd.

60 APPLIED LIFE SCIENCES↗

Performance and Stability Characterization of the ICARUS Light Detection System

The ICARUS detector, a key component of the Short Baseline Neutrino (SBN) Program at Fermilab, consists of two identical T300 modules filled with liquid argon. It is equipped with a Light Detection System (LDS) based on 360 8-inch Hamamatsu R5912-MOD photomultiplier tubes (PMTs) arranged behind the wire planes to collect Vacuum Ultraviolet (VUV, $\sim$ 128 nm) scintillation light. Operating under cryogenic conditions ( $\sim$ 87 K), the LDS is essential for determining the event start time (t0) with nanosecond precision for beam spill synchronization, improving longitudinal spatial resolution, and contributing to the event trigger and cosmic-ray mitigation. The performance of the LDS was investigated addressing both hardware and data analysis aspects. Following a progressive degradation in PMT gain observed during operations at FNAL, systematic gain measurements were first carried out from room temperature down to low temperatures. The results show stable performance at room temperature but a significant, irreversible reduction in gain at low temperatures. Based on these findings, a series of mitigation strategies were implemented in the ICARUS detector to preserve PMT performance and ensure reliable cryogenic operation. Currently, ongoing waveform analysis of the PMT signals is being performed to characterize signal shape, charge integration, and timing properties, aiming to refine and improve the agreement between experimental data and Monte Carlo simulations.

Saia, Clara [U. Catania (main); INAF, Catania; Cat↗

Evaluating runoff simulations from the Community Land Model 4.0 using observations from flux towers and a mountainous watershed

Previous studies using the Community Land Model (CLM) focused on simulating landatmosphere interactions and water balance at continental to global scales, with limited attention paid to its capability for hydrologic simulations at watershed or regional scales. This study evaluates the performance of CLM 4.0 (CLM4) for hydrologic simulations, and explores possible directions of improvement. Specifically, it is found that CLM4 tends to produce unrealistically large temporal variation of runoff for applications at a mountainous catchment in the Northwest United States where subsurface runoff is dominant, as well as at a few flux tower sites. We show that runoff simulations from CLM4 can be improved by: (1) increasing spatial resolution of the land surface representations; (2) calibrating parameter values; (3) replacing the subsurface formulation with a more general nonlinear function; (4) implementing the runoff generation schemes from the Variability Infiltration Capacity (VIC) model. This study also highlights the importance of evaluating both the energy and water fluxes application of land surface models across multiple scales.

58 GEOSCIENCES↗

Accelerated light-induced degradation for detecting copper contamination in p-type silicon

Copper is a harmful metal impurity that significantly impacts the performance of silicon-based devices if present in active regions. In this contribution, we propose a fast method consisting of simultaneous illumination and annealing for the detection of copper contamination in p-type silicon. Our results show that, within minutes, such method is capable of producing a significant reduction of the minority carrier lifetime. A spatial distribution map of copper contamination can then be obtained through the lifetime values measured before and after degradation. In order to separate the effect of the light-activated copper defects from the other metastable complexes in low resistivity Cz-silicon, we carried out a dark anneal at 200 °C, which is known to fully recover the boron-oxygen defect. Similar to the boron-oxygen behavior, we show that the dark anneal also recovers the copper defects. However, the recovery is only partial and it can be used to identify the possible presence of copper contamination.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WE-G-204-02: Utility of a Channelized Hotelling Model Observer Over a Large Range of Angiographic Exposure Levels

Purpose: Mathematical model observers provide a figure of merit that simultaneously considers a test object and the contrast, noise, and spatial resolution properties of an imaging system. The purpose of this work was to investigate the utility of a channelized Hotelling model observer (CHO) to assess system performance over a large range of angiographic exposure conditions. Methods: A 4 mm diameter disk shaped, iodine contrast test object was placed on a 20 cm thick Lucite phantom and 1204 image frames were acquired using fixed x-ray beam quality and for several detector target dose (DTD) values in the range 6 to 240 nGy. The CHO was implemented in the spatial domain utilizing 96 Gabor functions as channels. Detectability index (DI) estimates were calculated using the “resubstitution” and “holdout” methods to train the CHO. Also, DI values calculated using discrete subsets of the data were used to estimate a minimally biased DI as might be expected from an infinitely large dataset. The relationship between DI, independently measured CNR, and changes in results expected assuming a quantum limited detector were assessed over the DTD range. Results: CNR measurements demonstrated that the angiography system is not quantum limited due to relatively increasing contamination from electronic noise that reduces CNR for low DTD. Direct comparison of DI versus CNR indicates that the CHO relatively overestimates DI for low DTD and/or underestimates DI values for high DTD. The relative magnitude of the apparent bias error in the DI values was ∼20% over the 40x DTD range investigated. Conclusion: For the angiography system investigated, the CHO can provide a minimally biased figure of merit if implemented over a restricted exposure range. However, bias leads to overestimates of DI for low exposures. This work emphasizes the need to verify CHO model performance during real-world application.

60 APPLIED LIFE SCIENCES↗

Spatially Accelerated Winding Numbers for Curved Geometry

The generalized winding number (GWN) is a scalar field that supports robust containment queries on curved geometry, including non-watertight, overlapping, and nested boundary representations. While queries can be easily parallelized over samples, direct evaluation on parametric curves and surfaces remains costly for large and complex models. Fast, state-of-the-art GWN approaches leverage a spatial index to approximate the GWN, typically coupled with a Taylor expansion which approximates the GWN contribution for far clusters of geometric primitives. However, such methods operate only on discrete inputs such as triangle meshes and point clouds, and would introduce containment errors near boundaries if applied to curved input. We extend support for fast GWN evaluation over arbitrary collections of NURBS curves in 2D and trimmed NURBS patches in 3D via a Bounding Volume Hierarchy that stores efficiently precomputed moment data in the hierarchy nodes. When querying the hierarchy, approximations for far clusters are used alongside direct evaluation for nearby NURBS primitives, achieving sub-linear complexity while preserving the geometric features in the vicinity of the query point. Central to our performance improvements is an adaptive subdivision strategy for NURBS primitives during a preprocessing phase, creating better spatial partitions while retaining the same accuracy for containment decisions as a direct evaluation. We demonstrate the performance and accuracy of our approach across a large collection of 2D and 3D datasets.

Computer science↗

PV Degradation Modeling: Applying Geospatial Workflows with "PVDeg"

Accurate degradation modeling is essential for predicting photovoltaic (PV) module performance, estimating longevity and informing design decisions. With degradation rates varying significantly by location, geospatial analysis is critical for PV and broader applications, such as agrivoltaics, weathering and environmental data analysis. This work presents PVDeg, an open-source tool designed for geospatial degradation analysis. PVDeg integrates meteorological data from global sources, including the National Solar Radiation Database (NSRDB) and Photovoltaic Geographical Information System (PVGIS), with degradation models. The toolkit enables users to customize geospatial workflows by integrating weather data, material parameters, and user-defined Python functions. It facilitates accelerated downloads of NSRDB and PVGIS datasets and optimizes geospatial point selection to preserve data density in regions of interest. Additionally, PVDeg provides a local database for storage and spatial queries, supporting large-scale analyses without the need for high-performance computing (HPC) resources. PVDeg provides a foundational workflow that extends its utility beyond PV applications, enabling researchers to analyze geospatial processes across discipline.

14 SOLAR ENERGY↗

Spectrally Resolved Intensities of Ultra-Dense Hot Aluminum Plasmas

We present a first study of spectroscopic determination of electron temperature and density spatial profiles of aluminum K-shell line emission spectra from laser-shocked aluminum experiments performed at LULI. The radiation emitted by the aluminum plasma was dispersed with an ultra-high resolution spectrograph ({lambda}/{delta}{lambda}{approx_equal}6000). From the recorded films one can extract a set of time-integrated emission lineouts associated with the corresponding spatial region of the plasma. The observed spectra include the Ly{alpha}, He{beta}, He{gamma}, Ly{beta} and Ly{gamma} line emissions and their associated He- and Li-like satellites thus covering a photon energy range from 1700 eV to 2400 eV approximately. The data analysis rely on the ABAKO/RAPCAL computational package, which has been recently developed at the University of Las Palmas de Gran Canaria and takes into account non-equilibrium collisional-radiative atomic kinetics, Stark broadened line shapes and radiation transport calculations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗