Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Chemical removal of contaminants from thin film Bi4Sr3Ca3Cu4O(16 + x) surfaces

A solution of Br in absolute ethanol, previously shown to be effective in removing nonsuperconducting species from Y-Ba-Cu-O thin film surfaces, is shown also to be effective in treating Bi-Sr-Ca-Cu-O thin film surfaces. X-ray photoelectron spectra obtained after etching are consistent with previously reported results obtained from samples cleaved or scraped in vacuum.

Vasquez, R. P.↗

Analysis of Molecular Contamination on Genesis Collectors Through Spectroscopic Ellipsometry

Before the spacecraft returned to Earth in September, the Genesis mission had a preliminary assessment plan in place for the purpose of providing information on the condition and availability of collector materials to the science community as a basis for allocation requests. One important component of that plan was the evaluation of collector surfaces for molecular contamination. Sources of molecular contamination might be the on-orbit outgassing of spacecraft and science canister components, the condensation of thruster by-products during spacecraft maneuvers, or the condensation of volatile species associated with reentry. Although the non-nominal return of the Genesis spacecraft introduced particulate contamination to the collectors, such as dust and heatshield carbon-carbon, it is unlikely to have caused any molecular deposition. The contingency team's quick action in returning the damaged payload the UTTR cleanroom by 6 PM the evening of recovery help to ensure that exposure to weather conditions and the environment were kept to a minimum.

McNamara, K. M.↗

Selective Determination of Methylmercury Levels in Mercury-Contaminated Topsoils from Oak Ridge, TN - 18163

Mercury (Hg) is a strong neurotoxin that affects the central and peripheral nervous system. Mercury has several organomercury species that bio-accumulate in many different environments. In early 1950's, elemental mercury was used for manufacturing of various components nuclear weapons systems in the Y-12 Security Complex in Oak Ridge, TN. The mercury released to the environment contaminated the facilities, soil, sediment, surface water, and groundwater within the boundaries of the Y-12 Plant and the downstream environment along the East Fork Poplar Creek. Remediation efforts have been made since then to alleviate the amount of mercury contamination that impacts the soil, water and wildlife at the Y-12 complex and surrounding areas. Yet, mercury levels in the water still exceed both the regulatory limits (51 ng/L) and the remediation goal (200 μg/L). Methylmercury (CH{sub 3}Hg) is the most toxic form of mercury that bio-accumulates exponentially compared to other forms of mercury. It is hypothesized that contaminated soils contain significant levels of methylmercury that contributes to contamination in nearby freshwater ecosystems in Y-12 complex. The objective of this study was to develop analytical method for selective determination of CH{sub 3}Hg from mercury-contaminated soils that contained elevated levels of inorganic mercury, Hg(II). Attempts were made to selectively extract CH{sub 3}Hg from spiked template soils via extraction in dilute hydrochloric (HCl) and nitric acids (HNO{sub 3}). The latter performed better than HCl affording quantitative extraction of CH{sub 3}Hg with minimal extraction of Hg(II). Under same circumstance, only about 5% of Hg(II) extracted from the soil matrix. Coprecipitation efforts were made using Bi(III), Fe(III) and La(III) alone and in conjunction with thiourea and L-cysteine. A combination of La(III) + L-cysteine afforded highest elimination of Hg(II) from solutions. Thiourea was not suitable for coprecipitation of Hg(II) as it also precipitated up to 67% of CH{sub 3}Hg from simulated soil solutions. Cold vapor generation (CVG) interfaced to ICP-MS was optimized for selective determination of CH{sub 3}Hg{sup +}. Calibration curves were established with CH{sub 3}Hg standards in La(III) and 0.1% L-cysteine and 5% (v/v) HNO{sub 3} by CVG-ICP-MS. The method was validated by determination of CH{sub 3}Hg in sediment reference material (SQC1238) and Estuarine sediment (ERM - CC580) containing trace levels of CH{sub 3}Hg in Hg(II) matrix. The procedure was applied to floodplain soils from Oak Ridge, TN. Methylmercury levels were in the range of 0.031 to 0.047 μg/g. The results indicated that CH{sub 3}Hg{sup +} levels were substantially lower inorganic Hg(II), still though CH{sub 3}Hg at these levels could be significant source of persistent mercury contamination in freshwater systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Use of Liquid Isopropyl Alcohol and Hydrogen Peroxide Gas Plasma to Biologically Decontaminate Spacecraft Electronics

Legitimate concern exists regarding sending spacecraft and their associated hardware to solar system bodies where they could possibly contaminate the body's surface with terrestrial microorganisms. The NASA approved guidelines for sterilization as set forth in NPG 8020.12C, which is consistent with the biological contamination control objectives of the Committee on Space Research (COSPAR), recommends subjecting the spacecraft and its associated hardware to dry heat-a dry heat regimen that could potentially employ a temperature of 110(deg)C for up to 200 hours. Such a temperature exposure could prove detrimental to the spacecraft electronics. The stimulated growth of intermetallic compounds (IMCs) in metallic interconnects and/or thermal degradation of organic materials composing much of the hardware could take place over a prolonged temperature regimen. Such detrimental phenomena would almost certainly compromise the integrity and reliability of the electronics. Investigation of sterilization procedures in the medical field suggests that hydrogen peroxide (H202) gas plasma (HPGP) technology can effectively function as an alternative to heat sterilization, especially for heat-sensitive items. Treatment with isopropyl alcohol (IPA) in liquid form prior to exposure of the hardware to HPGP should also prove beneficial. Although IPA is not a sterilant, it is frequently used as a disinfectant because of its bactericidal properties. The use of IPA in electronics cleaning is widely recognized and has been utilized for many years with no adverse affects reported. In addition, IPA is the principal ingredient of the test fluid used in ionic contamination testers to assess the amount of ionic contamination found on the surfaces of printed wiring assemblies. This paper will set forth experimental data confirming the feasibility of the IPA/H202 approach to reach acceptable microbial reduction (MR) levels of spacecraft electronic hardware. In addition, a proposed process flow in which both IPA liquid and HPGP are utilized will be presented in Section 7.0.

microbial reduction↗

Simulating Uranium(VI) Diffusion in Sodium-Montmorillonite as a Function of Chemical Solution Conditions

Most nuclear waste disposal options include compacted bentonite, predominately consisting of montmorillonite clay, as part of a barrier system to minimize contaminant mobility. Uranium (U) is the primary element in spent nuclear fuel, and a potential contaminant of water resources. Uranium sorption onto clay and its slow diffusive transport away from waste canisters are expected to limit U(VI) mobility in these systems. However, their prediction is complicated by the complex mineralogical structure of montmorillonite clay, leading to two types of surface sites and clay porosities, and by the dependence of U(VI) solution speciation on chemical conditions. For instance, depending on pH and ionic strength, U(VI) may sorb onto montmorillonite due to weak ion exchange reactions or the formation of stable surface complexes. Furthermore, at the high degrees of clay compaction expected in future barrier systems, the ability of U(VI) species to access small, highly negatively charged interlayer spaces may ultimately control diffusive fluxes. In this modeling study, we investigate how the charge of U(VI) solution species affects U(VI) sorption and diffusion behavior. For this purpose, we simplified complex chemical solution speciation diagrams to charge speciation diagrams. Furthermore, we coupled an existing U(VI) sorption model (in PHREEQC) with U(VI) diffusion calculations (in GLE) to simulate U(VI) mobility in lab-scale through-diffusion experiments over various chemical conditions. Our results suggest that there are two important parameters that govern U(VI) diffusion in these systems. Uranium(VI) surface complexation on clay edge surfaces leads to contaminant retardation, while the access of U(VI) solution species to diffuse layers in clay interlayer spaces controls diffusive fluxes. Hence on the field scale, these parameters will determine how early a plume may cross site boundaries and pose risks to drinking water resources, and the levels of U(VI) concentrations to be expected in contaminated waters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determining Temperature Differential to Prevent Hardware Cross-Contamination in a Vacuum Chamber

When contamination-sensitive hardware must be tested in a thermal vacuum chamber, cross-contamination from other hardware present in the chamber, or residue from previous tests, becomes a concern. Typical mitigation strategies involve maintaining the temperature of the critical item above that of other hardware elements at the end of the test. A formula for relating the pumping speed of a chamber, the surface area of contamination sources, and the temperatures of the chamber, source, and contamination-sensitive items has been developed. The formula allows the determination of a temperature threshold about which contamination will not condense on the sensitive items. It defines a parameter alpha that is the fraction given by (contaminant source area)/[chamber pumping speed (time under vacuum) 0.5]. If this parameter is less than 10(exp -6), cross-contamination from common spacecraft material will not occur when the sensitive hardware is at the same temperature as the source of contamination (The chamber is isothermal within 5 C.). Knowing when it becomes safe to have the hardware isothermal permits faster and easier thermal transitions when compared with maintaining an arbitrary temperature differential between parts. Furthermore, the standard temperature differential may not be adequate under some conditions (alpha>10(exp -4)).

Hughes, David↗

Rocky Flats Closure: the Role of Models in Facilitating Scientific Communication With Stakeholder Groups

The Rocky Flats Environmental Technology Site (RFETS) was a U.S. Department of Energy (DOE) environmental cleanup site for a previous manufacturing plant that made components for the U.S. nuclear weapons arsenal. The facility was shut down in 1989 to address environmental and safety concerns, and left behind a legacy of contaminated facilities, soils, surface and ground water. In 1995, the Site contractor established the Actinide Migration Evaluation (AME) advisory group to provide advice and technical expertise on issues of actinide behavior and mobility in the air, surface water, groundwater, and soil. Through a combination of expert judgment supported by state-of-the-art scientific measurements, it was shown that under environmental conditions at Rocky Flats, plutonium and americium form insoluble oxides that adhere to small soil, organic, and mineral particles and colloids, or are colloidal materials themselves. A series of models ranging from conceptual, geostatistical, and large-scale wind and surface water erosion models were used to guide stakeholder interactions. The nature of these models, and their use in public communication is described.

54 ENVIRONMENTAL SCIENCES↗

Comparison of Statistically Modeled Contaminated Soil Volume Estimates and Actual Excavation Volumes at the Maywood FUSRAP Site - 13555

As part of the ongoing remediation process at the Maywood Formerly Utilized Sites Remedial Action Program (FUSRAP) properties, Argonne National Laboratory (Argonne) assisted the U.S. Army Corps of Engineers (USACE) New York District by providing contaminated soil volume estimates for the main site area, much of which is fully or partially remediated. As part of the volume estimation process, an initial conceptual site model (ICSM) was prepared for the entire site that captured existing information (with the exception of soil sampling results) pertinent to the possible location of surface and subsurface contamination above cleanup requirements. This ICSM was based on historical anecdotal information, aerial photographs, and the logs from several hundred soil cores that identified the depth of fill material and the depth to bedrock under the site. Specialized geostatistical software developed by Argonne was used to update the ICSM with historical sampling results and down-hole gamma survey information for hundreds of soil core locations. The updating process yielded both a best guess estimate of contamination volumes and a conservative upper bound on the volume estimate that reflected the estimate's uncertainty. Comparison of model results to actual removed soil volumes was conducted on a parcel-by-parcel basis. Where sampling data density was adequate, the actual volume matched the model's average or best guess results. Where contamination was un-characterized and unknown to the model, the actual volume exceeded the model's conservative estimate. Factors affecting volume estimation were identified to assist in planning further excavations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Combination of imaging mass spectrometry and electron microscopy for quasi nondestructive surface analysis

We report on a combination of imaging mass spectrometry (MS) and scanning electron microscopy (SEM) developed in a custom designed time-of-flight (TOF) MS instrument with laser post-ionization of sputtered atoms. Elemental (by MS) and topographical (by SEM) mapping of surfaces of heavily contaminated Si collectors from the NASA Genesis sample return mission enabled obtaining much more accurate and detailed depth distribution of the Solar Wind Mg and Ca implanted in these collectors. This is because the cleanest areas were identified by the SEM/MS mapping, and high resolution sputter depth profiling at these locations revealed near-surface (0-15 nm) depth distribution of Mg and Ca, that were used for more accurate fluence calculations of these Solar Wind species. MS imaging was virtually nondestructive at primary ion fluence 10(12) cm(-2), causing no effect on accuracy and precision of quantitative depth profiling that followed the imaging. We also demonstrate importance of such an approach by directly comparing high resolution depth profiles measured on clean areas versus arbitrarily selected areas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

XPS study of the effect of hydrocarbon contamination on polytetrafluoroethylene (teflon) exposed to atomic oxygen

The presence of hydrocarbon contamination on the surface of polytetrafluoroethylene (PTFE) markedly affects the oxygen uptake, and hence the wettability, of this polymer when exposed to an oxygen plasma. As revealed by X-ray photoelectron spectroscopy (XPS) analysis, the oxygen-to-carbon ratio (O/C) for such a polymer can increase sharply, and correspondingly the fluorine-to-carbon ratio (F/C) can decrease sharply, at very short exposure times; at longer times, however, such changes in the O/C and F/C ratios reverse direction, and these ratios then assume values similar to those of the unexposed PTFE. The greater the extent of hydrocarbon contamination in the PTFE, the larger are the amplitudes of the 'spikes' in the O/C- and F/C-exposure time plots. In contrast, a pristine PTFE experiences a very small, monotonic increase of surface oxidation or O/C ratio with time of exposure to oxygen atoms, while the F/C ratio is virtually unchanged from that of the unexposed polymer (2.0). Unless the presence of adventitious hydrocarbon is taken into account, anomalous surface properties relating to polymer adhesion may be improperly ascribed to PTFE exposed to an oxygen plasma.

Golub, Morton A.↗

Operation of the computer model for direct atomic oxygen exposure of Earth satellites

One of the primary causes of material degradation in low Earth orbit (LEO) is exposure to atomic oxygen. When atomic oxygen molecules collide with an orbiting spacecraft, the relative velocity is 7 to 8 km/sec and the collision energy is 4 to 5 eV per atom. Under these conditions, atomic oxygen may initiate a number of chemical and physical reactions with exposed materials. These reactions contribute to material degradation, surface erosion, and contamination. Interpretation of these effects on materials and the design of space hardware to withstand on-orbit conditions requires quantitative knowledge of the atomic oxygen exposure environment. Atomic oxygen flux is a function of orbit altitude, the orientation of the orbit plan to the Sun, solar and geomagnetic activity, and the angle between exposed surfaces and the spacecraft heading. We have developed a computer model to predict the atomic oxygen exposure of spacecraft in low Earth orbit. The application of this computer model is discussed.

Bourassa, R. J.↗

Non-Volatile Residue (NVR) Contamination from Dry Handling and Solvent Cleaning

This slide presentation reviews the testing for Non-Volatile Residue contamination transferred to surfaces from handling and solvent cleaning. Included in the presentation is a list of the items tested, formal work instructions dealing with NVR. There is an explanation of the Gravimetric determination method used to test the NVR in a variety of items, i.e., Gloves, Swabs, Garments, Bagging material, film and Wipes. Another method to test for contamination from NVR is the contact transfer method. The use of this method for testing gloves, garments, bagging material and film is explained. Certain equations use in NVR analysis and the use of a database for testing of NVR in consumables are reviewed.

Sovinski, Marjorie F.↗

Alternate Methods for Cleaning Zirconium Plate

The United States High Performance Research Reactor Conversion Program identified the need to transition from highly enriched uranium fuel to lowly enriched uranium fuel for high power research and civil reactors. One of the fuel configurations selected for these reactors was a uranium (U) foil alloyed with 10% molybdenum (Mo). The U-10Mo fuel foil was then covered with a zirconium (Zr) interlayer and pressed into an aluminum cladding. Idaho National Laboratory prescribed a need to remove surface oxidation on the Zr prior to bonding it with U-10Mo fuel foil. To determine the best method of oxidation removal, a variety of polishing methods, including hand polishing with a diamond paste or Scotch-Brite™ pads, mechanically wet-polishing with abrasive belts, and chemical etching with hydrofluoric/nitric acid mixtures, were investigated on pre-polished Zircaloy 702 sheets purchased directly from the manufacturer. No change in surface roughness was detected using any of these methods relative to the as-received material. In fact, scanning electron microscopy detected grit from hand polishing with Amplex Grade 30 waste soluble diamond paste and Scotch-Brite™ pads. Visible staining was found, and fluorine detected via X-ray photoelectron spectroscopy on the flash etching samples. These contaminants were not seen on the as-received material. In addition to the need to remove the oxide layer on the Zr prior to co-rolling, there are concerns that the Neolube debonding agent on the co-rolling can may contaminate the Zr surface after co-rolling. The experimental results found that zirconium in contact with Neolube coated steel plates was easily cleaning with ethanol wiping after heat treated and no carbide inclusions remained on the surface. Overall, all cleaning methods tested did not significantly change the surface roughness of the plates or reduce the oxide layer present on the zirconium. Carbon was found on all the samples, before and after cleaning, except for the flash etch samples which detected fluorine instead. The insignificant changes seen in the cleaned plates relative to the as received plates question the need for cleaning prior to rolling. Further investigation in the requirements for cleaning at this step is recommended. Current methods for cleaning the surface after hot rolling with alcohol appear sufficient. After hot rolling, if Neolube does peel off the can and onto the zirconium coated foil surface, a dry abrasive or diamond paste polish is not recommended due to the chance of abrasive being embedded into the surface. However, the ability of an etchant to lift the lubricant off the zirconium surface indicates that a spot etch method could work to clean specific spots where Neolube is present, if the need arises.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Method for determining coal carbon in the reclaimed minesoils contaminated with coal

Minesoils developed on the reclaimed surface-mined sites for coal are contaminated with coal particles resulting from mining and reclamation activities. Therefore, the total organic carbon (TOC) pool in these sites is a mixture of coal and plant-derived recent soil organic carbon (SOC). Accurate estimates of SOC pools and C sequestration rates in the reclaimed minesoils (RMS) is limited by the lack of a standard and cost-effective method for determination of coal C concentrations in the RMS. The chemi-thermal method, based on the oxidative resistance of coal, was developed and validated with radiocarbon analysis using selected artificial soil-coal mixtures and minesoil samples. Radiocarbon analysis of RMS samples indicated that minesoils from the top 10-cm depth developing from topsoil applied during reclamation was coal C free. The contribution of coal C and the radiocarbon age of TOC increased with increasing soil depth. The coal C fraction accounted for 0 to 92% of TOC in the RMS samples. The coal C fraction was highly correlated with {delta}{sup 13}C (r{sup 2} = 0.84), suggesting that stable isotope composition could estimate the coal C concentration in RMS samples. Analysis of coal and artificial soil and coal mixtures indicated that chemi-thermal treatment was effective in removing recent SOC with minimum effect on coal. Analysis of RMS samples indicated that both radiocarbon activity and the chemi-thermal method were effective in estimating coal C concentration in RMS of southeast Ohio. The coal C concentrations for both methods were highly correlated (r{sup 2} = 0.95), suggesting that the chemi-thermal method was as effective as radiocarbon activity measurement in estimating coal C concentration in these soils.

01 COAL, LIGNITE, AND PEAT↗

Results of groundwater monitoring at Everest, Kansas, in April 2008.

On September 7, 2005, the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) presented a Scoping Memo (Argonne 2005) for preliminary consideration by the Kansas Department of Health and Environment (KDHE), suggesting possible remedial options for the carbon tetrachloride contamination in groundwater at Everest, Kansas. The suggested approaches were discussed by representatives of the KDHE, the CCC/USDA, and Argonne at the KDHE office in Topeka on September 8-9, 2005, along with other technical and logistic issues related to the Everest site. In response to these discussions, the KDHE recommended (KDHE 2005) evaluation of several remedial processes, either alone or in combination, as part of a Corrective Action Study (CAS) for Everest. The primary remedial processes suggested by the KDHE were the following: Hydraulic control by groundwater extraction with aboveground treatment; Air sparging (AS) coupled with soil vapor extraction (SVE) in large-diameter boreholes (LDBs); and Phytoremediation. As a further outcome of the 2005 meeting and as a precursor to development of a possible CAS, the CCC/USDA completed the following supplemental investigations at Everest to address several specific technical concerns discussed with the KDHE: (1) Construction of interpretive cross sections at strategic locations selected by the KDHE along the main plume migration pathway, to depict the hydrogeologic characteristics affecting groundwater flow and contaminant movement (Argonne 2006a). (2) A field investigation in early 2006 (Argonne 2006b), as follows: (a) Installation and testing of a production well and associated observation points, at locations approved by the KDHE, to determine the response of the Everest aquifer to groundwater extraction near the Nigh property. (b) Groundwater sampling for the analysis of volatile organic compounds (VOCs) and the installation of additional permanent monitoring points at locations selected by the KDHE, to further constrain the existing contaminant plume. (c) Resampling of all existing permanent monitoring points for VOCs and biodegradation parameter analyses, at the request of the KDHE. On the basis of these studies (Argonne 2006a,b) and the CCC/USDA's past investigations at Everest (Argonne 2006c), the CCC/USDA concluded that groundwater extraction is not an effective remedial option for the main body of the groundwater plume, and the KDHE concurred (KDHE 2006); the KDHE later noted, however (KDHE 2007a), that this and other technologies might represent viable remedial options in the event of further downgradient migration of the plume toward the intermittent creek. In February 2007, the CCC/USDA presented preliminary analyses of (1) the AS-SVE remedial alternative, incorporating the use of LDBs, and (2) the risks to human health and the environment posed by the observed carbon tetrachloride plume in groundwater (Argonne 2007a). The results of these analyses demonstrated the following: (1) Neither groundwater extraction nor AS-SVE in LDBs represents a practical approach for effective remediation of the groundwater contamination at Everest (near the Nigh property). (2) Periodic sampling and analyses for VOCs conducted by the CCC/USDA documented that the areal extent and range of carbon tetrachloride concentrations detected in the groundwater plume at Everest had changed relatively little from 2000 to 2006. (3) Estimates of groundwater flow and contaminant migration times, based on the hydrogeologic properties of the groundwater flow system identified at Everest (Argonne 2003, 2006b,c), indicated that, at minimum, approximately 4 years would be required for the carbon tetrachloride plume (in the subsurface) to reach the vicinity of the intermittent creek directly west of the Nigh property, and more than 20 years would be required for the contamination to reach the identified groundwater discharge area southwest of the Nigh property. (4) The existing (January-March 2006) plume posed no immediate danger of contamination to the surface waters of the intermittent creek. In light of these observations, the CCC/USDA proposed a phased program--over approximately 2-3 years--of groundwater sampling, surface water sampling, and related monitoring activities at Everest to (1) identify locations where a phytoremediation system would be effective and determine that area's extent and (2) support the potential development of a phytoremediation treatment alternative for the site. The recommended elements of the monitoring program are summarized in Table 1.1. In conjunction with this program, both the CCC/USDA and the KDHE recommended the construction of several new monitoring wells, at locations along and near the intermittent creek west of the Nigh property (Argonne 2007b; KDHE 2007b).

54 ENVIRONMENTAL SCIENCES↗