Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

TU-EF-207-02: Spectral Mammography Based on Photon Counting Detectors

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

TU-D-202-03: Gating Is the Best ITV Killer

Respiratory motion has long been recognized as an important factor affecting the precision of radiotherapy. After the introduction of the 4D CT to visualize the respiratory motion in 3D, the internal target volume (ITV) has been widely adopted as simple method to take the motion into account in treatment planning and delivery. The ITV is generated as the union of the CTVs as the patient goes through the respiratory cycle. Many issues have been identified with the ITV. In this session three alternatives for the ITV will be discussed: 1) An alternative motion-inclusive approach with better imaging and smaller margins, called mid-position CT. 2) The tracking approach and 3) The gating approach. The following topics will be addressed by Marcel van Herk (“Is ITV the correct motion encompassing strategy”): Magnitude of respiratory motion, effect of motion on radiotherapy, motion encompassing strategies, and software solutions to assist in motion encompassing strategies. Then Paul Keall (“Make margins simple: Use real-time target tracking”) will discuss tracking with: clinical drivers for tracking, current clinical status of tumor tracking, future tumor tracking technology, and margin margin challenges with and without tracking. Finally Daniel Low will discuss gating (“Gating is the best ITV killer”): why ITV in the first place, requirements for planning, requirements at the machine, benefits and costs. The session will end with a discussion and live demo of motion simulation software to illustrate the issues and explain the relative benefit and appropriate uses for the three methods. Learning Objectives: Explain the 4D imaging and treatment planning process. Summarize the various approaches to deal with respiratory motion during radiotherapy Discuss the tradeoffs involved when choosing one of the three discussed approaches. Explain in which situation each method is the best choice Research is partly funded by Elekta Oncology Systems and the Dutch Cancer Foundation; M. van Herk, Part of the research was funded by Elekta Oncology Systems and the Dutch Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

TU-EF-207-01: Introductory Remarks on Recent Advances in Breast Imaging

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

Dual resolution cone beam breast CT: A feasibility study

Purpose: In this study, the authors investigated the feasibility of a dual resolution volume-of-interest (VOI) cone beam breast CT technique and compared two implementation approaches in terms of dose saving and scatter reduction. Methods: With this technique, a lead VOI mask with an opening is inserted between the x-ray source and the breast to deliver x-ray exposure to the VOI while blocking x rays outside the VOI. A CCD detector is used to collect the high resolution projection data of the VOI. Low resolution cone beam CT (CBCT) images of the entire breast, acquired with a flat panel (FP) detector, were used to calculate the projection data outside the VOI with the ray-tracing reprojection method. The Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the dual resolution 3D images. Breast phantoms with 180 {mu}m and smaller microcalcifications (MCs) were imaged with both FP and FP-CCD dual resolution CBCT systems, respectively. Two approaches of implementing the dual resolution technique, breast-centered approach and VOI-centered approach, were investigated and evaluated for dose saving and scatter reduction with Monte Carlo simulation using a GEANT4 package. Results: The results showed that the breast-centered approach saved more breast absorbed dose than did VOI-centered approach with similar scatter reduction. The MCs in fatty breast phantom, which were invisible with FP CBCT scan, became visible with the FP-CCD dual resolution CBCT scan. Conclusions: These results indicate potential improvement of the image quality inside the VOI with reduced breast dose both inside and outside the VOI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deformable segmentation of 3D MR prostate images via distributed discriminative dictionary and ensemble learning

Purpose: Automatic prostate segmentation from MR images is an important task in various clinical applications such as prostate cancer staging and MR-guided radiotherapy planning. However, the large appearance and shape variations of the prostate in MR images make the segmentation problem difficult to solve. Traditional Active Shape/Appearance Model (ASM/AAM) has limited accuracy on this problem, since its basic assumption, i.e., both shape and appearance of the targeted organ follow Gaussian distributions, is invalid in prostate MR images. To this end, the authors propose a sparse dictionary learning method to model the image appearance in a nonparametric fashion and further integrate the appearance model into a deformable segmentation framework for prostate MR segmentation. Methods: To drive the deformable model for prostate segmentation, the authors propose nonparametric appearance and shape models. The nonparametric appearance model is based on a novel dictionary learning method, namely distributed discriminative dictionary (DDD) learning, which is able to capture fine distinctions in image appearance. To increase the differential power of traditional dictionary-based classification methods, the authors' DDD learning approach takes three strategies. First, two dictionaries for prostate and nonprostate tissues are built, respectively, using the discriminative features obtained from minimum redundancy maximum relevance feature selection. Second, linear discriminant analysis is employed as a linear classifier to boost the optimal separation between prostate and nonprostate tissues, based on the representation residuals from sparse representation. Third, to enhance the robustness of the authors' classification method, multiple local dictionaries are learned for local regions along the prostate boundary (each with small appearance variations), instead of learning one global classifier for the entire prostate. These discriminative dictionaries are located on different patches of the prostate surface and trained to adaptively capture the appearance in different prostate zones, thus achieving better local tissue differentiation. For each local region, multiple classifiers are trained based on the randomly selected samples and finally assembled by a specific fusion method. In addition to this nonparametric appearance model, a prostate shape model is learned from the shape statistics using a novel approach, sparse shape composition, which can model nonGaussian distributions of shape variation and regularize the 3D mesh deformation by constraining it within the observed shape subspace. Results: The proposed method has been evaluated on two datasets consisting of T2-weighted MR prostate images. For the first (internal) dataset, the classification effectiveness of the authors' improved dictionary learning has been validated by comparing it with three other variants of traditional dictionary learning methods. The experimental results show that the authors' method yields a Dice Ratio of 89.1% compared to the manual segmentation, which is more accurate than the three state-of-the-art MR prostate segmentation methods under comparison. For the second dataset, the MICCAI 2012 challenge dataset, the authors' proposed method yields a Dice Ratio of 87.4%, which also achieves better segmentation accuracy than other methods under comparison. Conclusions: A new magnetic resonance image prostate segmentation method is proposed based on the combination of deformable model and dictionary learning methods, which achieves more accurate segmentation performance on prostate T2 MR images.

60 APPLIED LIFE SCIENCES↗

High-speed x-ray phase contrast imaging and digital image correlation analysis of microscale shock response of an additively manufactured energetic material simulant

The performance of energetic materials subjected to dynamic loading significantly depends on their micro- and meso-scale structural morphology. The geometric versatility offered by additive manufacturing opens new pathways to tailor the performance of these materials. Additively manufactured energetic materials (AMEMs) have a wide range of structural characteristics with a hierarchy of length scales and process-inherent heterogeneities, which are hitherto difficult to precisely control. It is important to understand how these features affect AMEMs’ response under dynamic/shock loading. Therefore, temporally and spatially resolved measurements of both macroscopic behavior and micro- and meso-level processes influencing macroscopic behavior are required. In this paper, we analyze the shock compression response of an AMEM simulant loaded under several impact conditions and orientations. Furthermore, x-ray phase contrast imaging (PCI) is used to track features across the observed shock front and determine the linear shock velocity vs particle velocity equation of state, as well as to quantify the interior deformation fields via digital image correlation (DIC) analyses. Photon Doppler velocimetry is simultaneously used to measure the particle velocities of the specimens, which are consistent with those obtained from x-ray PCI. The DIC analyses provide an assessment of the average strain fields inside the material, showing that the average axial strain depends on the loading intensity and reaches as high as 0.23 for impact velocities up to 1.5 km/s. The overall results demonstrate the utility of x-ray PCI for probing “in-material” equation of state and interior strains associated with dynamic shock compression behavior of the AMEM simulant.

3D printing↗

TU-A-12A-07: CT-Based Biomarkers to Characterize Lung Lesion: Effects of CT Dose, Slice Thickness and Reconstruction Algorithm Based Upon a Phantom Study

Purpose: Radiogenomics promises the ability to study cancer tumor genotype from the phenotype obtained through radiographic imaging. However, little attention has been paid to the sensitivity of image features, the image-based biomarkers, to imaging acquisition techniques. This study explores the impact of CT dose, slice thickness and reconstruction algorithm on measuring image features using a thorax phantom. Methods: Twentyfour phantom lesions of known volume (1 and 2mm), shape (spherical, elliptical, lobular and spicular) and density (-630, -10 and +100 HU) were scanned on a GE VCT at four doses (25, 50, 100, and 200 mAs). For each scan, six image series were reconstructed at three slice thicknesses of 5, 2.5 and 1.25mm with continuous intervals, using the lung and standard reconstruction algorithms. The lesions were segmented with an in-house 3D algorithm. Fifty (50) image features representing lesion size, shape, edge, and density distribution/texture were computed. Regression method was employed to analyze the effect of CT dose, slice of thickness and reconstruction algorithm on these features adjusting 3 confounding factors (size, density and shape of phantom lesions). Results: The coefficients of CT dose, slice thickness and reconstruction algorithm are presented in Table 1 in the supplementary material. No significant difference was found between the image features calculated on low dose CT scans (25mAs and 50mAs). About 50% texture features were found statistically different between low doses and high doses (100 and 200mAs). Significant differences were found for almost all features when calculated on 1.25mm, 2.5mm, and 5mm slice thickness images. Reconstruction algorithms significantly affected all density-based image features, but not morphological features. Conclusions: There is a great need to standardize the CT imaging protocols for radiogenomics study because CT dose, slice thickness and reconstruction algorithm impact quantitative image features to various degrees as our study has shown.

60 APPLIED LIFE SCIENCES↗

A Dataset of 3D Structural and Simulated Transport Properties of Complex Porous Media

Physical processes that occur within porous materials have wide-ranging applications including - but not limited to - carbon sequestration, battery technology, membranes, oil and gas, geothermal energy, nuclear waste disposal, water resource management. The equations that describe these physical processes have been studied extensively; however, approximating them numerically requires immense computational resources due to the complex behavior that arises from the geometrically-intricate solid boundary conditions in porous materials. Here, we introduce a new dataset of unprecedented scale and breadth, DRP-372: a catalog of 3D geometries, simulation results, and structural properties of samples hosted on the Digital Rocks Portal. The dataset includes 1736 flow and electrical simulation results on 217 samples, which required more than 500 core years of computation. This data can be used for many purposes, such as constructing empirical models, validating new simulation codes, and developing machine learning algorithms that closely match the extensive purely-physical simulation. This article offers a detailed description of the contents of the dataset including the data collection, simulation schemes, and data validation.

3D images↗

SU-E-J-74: Impact of Respiration-Correlated Image Quality On Tumor Motion Reconstruction in 4D-CBCT: A Phantom Study

Purpose: To investigate the effects of scanning parameters and respiratory patterns on the image quality for 4-dimensional cone-beam computed tomography(4D-CBCT) imaging, and assess the accuracy of computed tumor trajectory for lung imaging using registration of phased 4D-CBCT imaging with treatment planning-CT. Methods: We simulated a periodic and non-sinusoidal respirations with various breathing periods and amplitudes using a respiratory phantom(Quasar, Modus Medical Devices Inc) to acquire respiration-correlated 4D-CBCT images. 4D-CBCT scans(Elekta Oncology Systems Ltd) were performed with different scanning parameters for collimation size(e.g., small and medium field-of-views) and scanning speed(e.g., slow 50°·min{sup −1}, fast 100°·min{sup −1}). Using a standard CBCT-QA phantom(Catphan500, The Phantom Laboratory), the image qualities of all phases in 4D-CBCT were evaluated with contrast-to-noise ratio(CNR) for lung tissue and uniformity in each module. Using a respiratory phantom, the target imaging in 4D-CBCT was compared to 3D-CBCT target image. The target trajectory from 10-respiratory phases in 4D-CBCT was extracted using an automatic image registration and subsequently assessed the accuracy by comparing with actual motion of the target. Results: Image analysis indicated that a short respiration with a small amplitude resulted in superior CNR and uniformity. Smaller variation of CNR and uniformity was present amongst different respiratory phases. The small field-of-view with a partial scan using slow scan can improve CNR, but degraded uniformity. Large amplitude of respiration can degrade image quality. RMS of voxel densities in tumor area of 4D-CBCT images between sinusoidal and non-sinusoidal motion exhibited no significant difference. The maximum displacement errors of motion trajectories were less than 1.0 mm and 13.5 mm, for sinusoidal and non-sinusoidal breathings, respectively. The accuracy of motion reconstruction showed good overall agreement with the 4D-CBCT image quality results only using sinusoidal breathings. Conclusion: This information can be used to determine the appropriate acquisition parameters of 4D-CBCT imaging for registration accuracy and target trajectory measurements in a clinical setting.

60 APPLIED LIFE SCIENCES↗

Three-Dimensional Atmospheric Dynamics of Jupiter from Ground-Based Doppler Imaging Spectroscopy in the Visible

We present three-dimensional (3D) maps of Jupiter’s atmospheric circulation at cloud-top level from Doppler-imaging data obtained in the visible domain with JIVE, the second node of the JOVIAL network, which is mounted on the Dunn Solar Telescope at Sunspot, New Mexico. We report on 12 nights of observations between May 4 and May 30, 2018, representing a total of about 80 hours. Firstly, the average zonal wind profile derived from our data is compatible with that derived from cloud-tracking measurements performed on Hubble Space Telescope images obtained in April 2018 from the Outer Planet Atmospheres Legacy (OPAL) program. Secondly, we present the first ever two-dimensional maps of Jupiter’s atmospheric circulation from Doppler measurements. The zonal velocity map highlights well-known atmospheric features, such as the equatorial hot spots and the Great Red Spot (GRS). In addition to zonal winds, we derive meridional and vertical velocity fields from the Doppler data. The motions attributed to vertical flows are mainly located at the boundary between the equatorial belts and tropical zones, which could indicate active motion in these regions. Qualitatively, these results compare well to recent Juno data that have unveiled the three-dimensional structure of Jupiter’s wind field. To the contrary, the motions attributed to meridional circulation are very different from what is obtained by cloud tracking, except at the GRS. Because of limitations with data resolution and processing techniques, we acknowledge that our measurement of vertical or meridional flows of Jupiter are still to be confirmed.

Francois-Xavier Schmider↗

Tomographic image via background subtraction using an x-ray projection image and a priori computed tomography

Kilovoltage x-ray projection images (kV images for brevity) are increasingly available in image guided radiotherapy (IGRT) for patient positioning. These images are two-dimensional (2D) projections of a three-dimensional (3D) object along the x-ray beam direction. Projecting a 3D object onto a plane may lead to ambiguities in the identification of anatomical structures and to poor contrast in kV images. Therefore, the use of kV images in IGRT is mainly limited to bony landmark alignments. This work proposes a novel subtraction technique that isolates a slice of interest (SOI) from a kV image with the assistance of a priori information from a previous CT scan. The method separates structural information within a preselected SOI by suppressing contributions to the unprocessed projection from out-of-SOI-plane structures. Up to a five-fold increase in the contrast-to-noise ratios (CNRs) was observed in selected regions of the isolated SOI, when compared to the original unprocessed kV image. The tomographic image via background subtraction (TIBS) technique aims to provide a quick snapshot of the slice of interest with greatly enhanced image contrast over conventional kV x-ray projections for fast and accurate image guidance of radiation therapy. With further refinements, TIBS could, in principle, provide real-time tumor localization using gantry-mounted x-ray imaging systems without the need for implanted markers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intracranial CT angiography obtained from a cerebral CT perfusion examination

CT perfusion (CTP) examinations of the brain are performed increasingly for the evaluation of cerebral blood flow in patients with stroke and vasospasm after subarachnoid hemorrhage. Of the same patient often also a CT angiography (CTA) examination is performed. This study investigates the possibility to obtain CTA images from the CTP examination, thereby possibly obviating the CTA examination. This would save the patient exposure to radiation, contrast, and time. Each CTP frame is a CTA image with a varying amount of contrast enhancement and with high noise. To improve the contrast-to-noise ratio (CNR) we combined all 3D images into one 3D image after registration to correct for patient motion between time frames. Image combination consists of weighted averaging in which the weighting factor of each frame is proportional to the arterial contrast. It can be shown that the arterial CNR is maximized in this procedure. An additional advantage of the use of the time series of CTP images is that automatic differentiation between arteries and veins is possible. This feature was used to mask veins in the resulting 3D images to enhance visibility of arteries in maximum intensity projection (MIP) images. With a Philips Brilliance 64 CT scanner (64x0.625 mm) CTP examinations of eight patients were performed on 80 mm of brain using the toggling table technique. The CTP examination consisted of a time series of 15 3D images (2x64x0.625 mm; 80 kV; 150 mAs each) with an interval of 4 s. The authors measured the CNR in images obtained with weighted averaging, images obtained with plain averaging, and images with maximal arterial enhancement. The authors also compared CNR and quality of the images with that of regular CTA examinations and examined the effectiveness of automatic vein masking in MIP images. The CNR of the weighted averaged images is, on the average, 1.73 times the CNR of an image at maximal arterial enhancement in the CTP series, where the use of plain averaging increases the CNR only with a factor of 1.49. The quality of the weighted averaged images approaches that of CTA images, although in the present study the image quality of CTA was not quite reached. The automatic masking of veins is effective and only small remnants of veins were sometimes present in the masked images. Weighted averaging makes it possible to create CTA images from a CTP examination with a CNR considerably higher than that of images with maximal arterial enhancement. The quality of the resulting images approaches that of CTA images and offers the additional advantages to automatically differentiate between arteries and veins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advances in physics and applications of 3D magnetic perturbations on the J-TEXT tokamak

In the last two years, three major technical improvements have been made on J-TEXT in supporting of the expanded operation regions and diagnostic capabilities. (1) The successful commission of the 105 GHz/500 kW/1 s electron cyclotron resonance heating (ECRH) system increasing the core electron temperature from 0.9 keV up to around 1.5 keV. (2) The poloidal divertor configuration with an X-point in the high-field side has been achieved. In particular, the 400 kW electron cyclotron wave has also been successfully injected into the diverted plasma. (3) A 256-channel electron cyclotron emission imaging diagnostic system and two sets of four-channel Doppler backscattering diagnostics have been successfully developed on J-TEXT, allowing detailed measurement of the electron temperature and density fluctuations for turbulence and MHD research. The locked mode (LM), especially the 2/1 LM, is one of the biggest threats to the plasma operation. Both the thresholds of 2/1 and 3/1 LM are observed to vary non-monotonically on electron density. The electrode biasing was applied successfully to unlock the LM from either a rotating or static resonant magnetic perturbation (RMP) field. In the presence of 2/1 LM, three kinds of standing wave (SW) structures have been observed to share a similar connection to the island structure, i.e. the nodes of the SWs locate around the O- or X-points of the 2/1 island. The control and mitigation of disruption is essential to the safe operation of ITER, and it has been systematically studied by applying a RMP field, massive gas injection (MGI) and shattered pellet injection on J-TEXT. When the RMP-induced 2/1 LM is larger than a critical width, the MGI shutdown process can be significantly influenced. If the phase difference between the O-point of LM and the MGI valve is +90° (or –90°), the penetration depth and the assimilation of impurities can be enhanced (or suppressed) during the pre-thermal quench (TQ) phase and result in a faster (or slower) TQ. A secondary MGI can also suppress the runaway electron (RE) generation, if the additional high-Z impurity gas arrives at the plasma edge before TQ. When the secondary MGI has been applied after the formation of the RE current plateau, the RE current can be dissipated, and the dissipation rate increases with the injected impurity quantity but saturates with a maximum of 28 MA s –1 . The non-local transport is experimentally observed in the ion transport channel. The electron thermal diffusivity significantly increases with the ECRH power. Theoretical work shows that significant intrinsic current can be driven by electromagnetic turbulence, and the robust formation mechanism of the E × B staircase is identified from the Hasegawa–Wakatani system.

divertor↗

Predictive Modeling of Carbon Ablators

Efforts to build a Predictive Material Modeling (PMM) framework from the micro-scale to the macro-scale are presented in this abstract. To reduce the need for extensive testing, accelerate the design cycle process, and reduce uncertainty margins applied to final designs, NASA is developing simulation and modeling tools that enable characterization of material properties and response to high-enthalpy environments. The Porous Microstructure Analysis (PuMA) code has been developed for computing macroscale (volume averaged) properties of porous materials using microscale images from micro-computed tomography (micro-CT). Microscale modeling requires a realistic representation of a material microstructure; these are obtained either synthetically during the design of the material or through X-ray micro-CT. Volume averaged properties are then used to inform macroscale material response models, such as those implemented in the Porous-material Analysis Toolbox based on OpenFOAM (PATO) software, also actively developed by NASA. The computational model in PATO is a generic heat and mass transfer model for porous reactive materials containing several solid phases and a single gas phase. The detailed chemical interactions occurring between the solid phases and the gas phase are modeled at the pore scale assuming local thermal equilibrium. These tools were developed to efficiently interface with other pre-existing codes such as SPARTA (direct simulation Monte Carlo), DPLR (hypersonic CFD), NEQAIR (radiative transport) and DAKOTA (uncertainty quantification and optimization). Detailed flight data (Mars Science Laboratory [MSL] Entry Descent and Landing Instrument [MEDLI]) is critical for validating these computational tools for NASA applications. Examples of modeling ablative material response using these codes will be presented including 3D simulations of the full-scale heatshield of the MSL capsule. The simulations demonstrate the ability of the modern material response code, PATO, to handle the material response of geometrically complex and large domains, through the use of massively parallel computations.

Thermal Protection Systems↗

Predictive Modeling of Carbon Ablators Using Micro and Macro-Scale Modeling

Efforts to build a Predictive Material Modeling (PMM) framework from the micro-scale to the macro-scale are presented in this abstract. To reduce the need for extensive testing, accelerate the design cycle process, and reduce uncertainty margins applied to final designs, NASA is developing simulation and modeling tools that enable characterization of material properties and response to high-enthalpy environments. The Porous Microstructure Analysis (PuMA) code has been developed for computing macroscale (volume averaged) properties of porous materials using microscale images from micro-computed tomography (micro-CT). Microscale modeling requires a realistic representation of a material microstructure; these are obtained either synthetically during the design of the material or through X-ray micro-CT. Volume averaged properties are then used to inform macroscale material response models, such as those implemented in the Porous-material Analysis Toolbox based on OpenFOAM (PATO) software, also actively developed by NASA. The computational model in PATO is a generic heat and mass transfer model for porous reactive materials containing several solid phases and a single gas phase. The detailed chemical interactions occurring between the solid phases and the gas phase are modeled at the pore scale assuming local thermal equilibrium. These tools were developed to efficiently interface with other pre-existing codes such as SPARTA (direct simulation Monte Carlo), DPLR (hypersonic CFD), NEQAIR (radiative transport) and DAKOTA (uncertainty quantification and optimization). Detailed flight data (Mars Science Laboratory [MSL] Entry Descent and Landing Instrument [MEDLI]) is critical for validating these computational tools for NASA applications. Examples of modeling ablative material response using these codes will be presented including 3D simulations of the full-scale heatshield of the MSL capsule. The simulations demonstrate the ability of the modern material response code, PATO, to handle the material response of geometrically complex and large domains, through the use of massively parallel computations.

Thermal Protection Systems↗

X-ray Computed Tomography Data of Dense Metallic Components

The data shared in here are X-ray computed tomography (XCT) scans of a hexagonal fuel nozzle in 3 sections with the Metrotom 800 system at the Manufacturing Demonstration Facility (MDF) at Oak Ridge National Laboratory. The data are used in the paper "Tomographic Sparse View Selection using the View Covariance Loss, by Lin et al. (doi:10.1109/TPAMI.2025.36000720), accepted to the international conference on computational imaging (ICCP 2025). Figures 4-7 in the paper describe the part/XCT scan. File name Descriptions: Bottom section: TCR- Single Channeled SRC L 2019-3-18 12-26-41.hdf5 Medium section: TCR- Single Channeled SRC M 2019-3-18 13-8-9.hdf5 Top section: TCR- Single Channeled SRC T 2019-3-18 13-45-39.hdf5 Each hdf5 file contains projection data, and all the relevant X-ray CT scan setting. The full list of included attributes: distance_unit: Units of all distances specified angle_unit : Units of the angles angles: Array of all angles used voxel_size_xy: Baseline recon (if any) has this voxel size in the in-plane direction voxel_size_z: Baseline recon (if any) has this voxel size in the cross-plane direction det_pixel_size_col: Size of the detector pixels in the column dimension det_pixel_size_row: Size of the detector pixels in the row dimension src_iso_dist: Source to iso-center distance iso_det_dist: Iso-center to detector distance det_angle: If the detector is rotated/tilted, this angle corresponds to that value det_row_offset: Center of rotation offset in the vertical direction det_col_offset: Center of rotation offset in the horizontal direction reconstruction: A baseline reconstruction stored as 3D array BHC params: Beam-hardening parameters - Van De Casteel Model - if it has been used to pre-process the projections We also provided a python script (hdf_io.py) that allows the user to read the relevant data from each hdf5 file.

Ziabari, Amir [Oak Ridge National Laboratory]↗

Towards gradient multimaterial toolpath generation for direct ink writing with connected fermat spirals

This work describes advances towards a reproducible, parametrically defined algorithm for generating graded multimaterial toolpaths for direct ink writing. Expanding on the existing Fermat space-filling algorithm and coupling with image-driven processing techniques, we demonstrate the fabrication of multimaterial structures. Here, material composition is encoded within toolpaths by parsing hue values from a multi-colored image. By performing dynamic velocity compensation based on local curvature and Euclidean distance filtering, internal voids are mitigated while optimizing print fidelity. Here, the work opens new avenues for designing complex toolpaths with locally programmable composition.

3D Printing↗

A method for robust segmentation of arbitrarily shaped radiopaque structures in cone-beam CT projections

Purpose: Implanted markers are commonly used in radiotherapy for x-ray based target localization. The projected marker position in a series of cone-beam CT (CBCT) projections can be used to estimate the three dimensional (3D) target trajectory during the CBCT acquisition. This has important applications in tumor motion management such as motion inclusive, gating, and tumor tracking strategies. However, for irregularly shaped markers, reliable segmentation is challenged by large variations in the marker shape with projection angle. The purpose of this study was to develop a semiautomated method for robust and reliable segmentation of arbitrarily shaped radiopaque markers in CBCT projections. Methods: The segmentation method involved the following three steps: (1) Threshold based segmentation of the marker in three to six selected projections with large angular separation, good marker contrast, and uniform background; (2) construction of a 3D marker model by coalignment and backprojection of the threshold-based segmentations; and (3) construction of marker templates at all imaging angles by projection of the 3D model and use of these templates for template-based segmentation. The versatility of the segmentation method was demonstrated by segmentation of the following structures in the projections from two clinical CBCT scans: (1) Three linear fiducial markers (Visicoil) implanted in or near a lung tumor and (2) an artificial cardiac valve in a lung cancer patient. Results: Automatic marker segmentation was obtained in more than 99.9% of the cases. The segmentation failed in a few cases where the marker was either close to a structure of similar appearance or hidden behind a dense structure (data cable). Conclusions: A robust template-based method for segmentation of arbitrarily shaped radiopaque markers in CBCT projections was developed.

60 APPLIED LIFE SCIENCES↗