Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Thermosyphon Cooler Hybrid System for Water Savings in an Energy-Efficient HPC Data Center: Results from 24 Months and the Impact on Water Usage Effectiveness

In August 2016, the National Renewable Energy Laboratory (NREL) installed a thermosyphon hybrid cooling system to reduce water usage in its already extremely energy-efficient High-Performance Computing (HPC) Data Center. In its first year of use, the system saved 4,400 m3 (1.16 million gal) of water, and 7,950 m3 (2.10 million gal) during a 2-year period, cutting the use of water in the data center by about one-half. NREL's 930-m2 (10,000-ft2) HPC Data Center is often called the most energy-efficient data center in the world: it has achieved a trailing 12-month average power usage effectiveness of 1.034, and it features a chiller-less design, component-level warm-water liquid cooling, and waste heat capture and reuse. NREL considered the amount of water used by the cooling towers to be counter to the laboratory's sustainability mission, so a team of researchers from NREL, Sandia National Laboratories (Sandia), and Johnson Controls integrated the BlueStream thermosyphon cooler (TSC) - an advanced dry cooler that uses refrigerant in a passive cycle to dissipate heat - on the roof of NREL's Energy Systems Integration Facility, the building that houses the HPC Data Center. In combination with the existing cooling towers, the TSC forms an extremely water- and cost-efficient cooling system. In its first year of operation, on-site water usage effectiveness (WUE) was 0.70 L/kWh. In comparison, the WUE would be 1.27 L/kWh if NREL had continued using only heat-recovery and cooling towers. This on-site water savings was accomplished without negatively impacting the energy-efficient operation of the HPC Data Center. The TSC system technology has the potential for application in data centers around the world, and it is currently being implemented by Sandia. center by about one-half. NREL's 930-m2 (10,000-ft2) HPC Data Center is often called the most energy-efficient data center in the world: it has achieved a trailing 12-month average power usage effectiveness of 1.034, and it features a chiller-less design, component-level warm-water liquid cooling, and waste heat capture and reuse. NREL considered the amount of water used by the cooling towers to be counter to the laboratory's sustainability mission, so a team of researchers from NREL, Sandia National Laboratories (Sandia), and Johnson Controls integrated the BlueStream thermosyphon cooler (TSC) - an advanced dry cooler that uses refrigerant in a passive cycle to dissipate heat - on the roof of NREL's Energy Systems Integration Facility, the building that houses the HPC Data Center. In combination with the existing cooling towers, the TSC forms an extremely water- and cost-efficient cooling system. In its first year of operation, on-site water usage effectiveness (WUE) was 0.70 L/kWh. In comparison, the WUE would be 1.27 L/kWh if NREL had continued using only heat-recovery and cooling towers. This on-site water savings was accomplished without negatively impacting the energy-efficient operation of the HPC Data Center. The TSC system technology has the potential for application in data centers around the world, and it is currently being implemented by Sandia.

97 MATHEMATICS AND COMPUTING↗

Energy Data Management Manual for the Wastewater Treatment Sector

Energy efficiency has become a higher priority within the wastewater treatment sector, with facility operators and state and local governments ramping up efforts to reduce energy costs and improve environmental performance. Across the country, municipal wastewater treatment plants are estimated to consume more than 30 terawatt hours per year of electricity, which equates to about $2 billion in annual electric costs. Electricity alone can constitute 25% to 40% of a wastewater treatment plant’s annual operating budget and make up a significant portion of a given municipality’s total energy bill. These energy needs are expected to grow over time, driven by population growth and increasingly stringent water quality requirements. The purpose of this document is to describe the benefits of energy data management, explain how it can help drive savings when linked to a strong energy management program, and provide clear, step-by-step guidance to wastewater treatment plants on how to appropriately track energy performance. It covers the basics of energy data management and related concepts and describes different options for key steps, recognizing that a single approach may not work for all agencies. Wherever possible, the document calls out simpler, less time-intensive approaches to help smaller plants with more limited resources measure and track energy performance. Reviews of key, publicly available energy-tracking tools are provided to help organizations select a tool that makes the most sense for them. Finally, this document describes additional steps wastewater treatment plant operators can take to build on their energy data management systems and further accelerate energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Irradiation Tests Supporting LEU Conversion of Very High Power Research Reactors in the US

The US fuel development team is developing a high density uranium-molybdenum alloy monolithic fuel to enable conversion of five high-power research reactors. Previous irradiation tests have demonstrated promising behavior for this fuel design. A series of future irradiation tests will enable selection of final fuel fabrication process and provide data to qualify the fuel at moderately-high power conditions for use in three of these five reactors. The remaining two reactors, namely the Advanced Test Reactor and High Flux Isotope Reactor, require additional irradiation tests to develop and demonstrate the fuel’s performance with even higher power conditions, complex design features, and other unique conditions. This paper reviews the program’s current irradiation testing plans for these moderately-high irradiation conditions and presents conceptual testing strategies to illustrate how subsequent irradiation tests will build upon this initial data package to enable conversion of these two very-high power research reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-resolution hourly surrogate modeling framework for physics-based large-scale building stock modeling

Surrogate modeling can play a key role in reducing high computational burdens for large-scale physics-based modeling and uncertainty quantification. With the rapid development of large-scale building stock energy modeling, surrogate modeling has also begun to be widely applied in this field; however, most existing surrogate models lack hourly time resolution for regional-scale modeling, which is essential for understanding building demand profiles and grid impacts. Further, there is generally a lack of necessary data and feature engineering frameworks specific to building modeling for efficiently managing large datasets and complex computations. Furthermore, this paper proposes a modeling framework for large-scale (city-/region-scale), high-resolution, high-fidelity surrogate building stock energy models. Our developed framework consists of six modules: (1) building stock energy modeling (ComStock TM and ResStock TM ), (2) data engineering for large simulation data, (3) high performance computing workflow, (4) feature engineering, (5) machine learning model development, and (6) model performance evaluation. Two case studies apply the developed framework in both residential and commercial building stock analysis to demonstrate its computational efficiency and surrogate modeling accuracies. Results show that surrogate models, when efficiently trained using the HPC workflow module, reach a high level of modeling accuracy for two case studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling, design and thermal performance of a BIPV/T system thermally coupled with a ventilated concrete slab in a low energy solar house: Part 1, BIPV/T system and house energy concept

This paper is the first of two papers that describe the modeling, design, and performance assessment based on monitored data of a building-integrated photovoltaic-thermal (BIPV/T) system thermally coupled with a ventilated concrete slab (VCS) in a prefabricated, two-storey detached, low energy solar house. This house, with a design goal of near net-zero annual energy consumption, was constructed in 2007 in Eastman, Quebec, Canada - a cold climate area. Several novel solar technologies are integrated into the house and with passive solar design to reach this goal. An air-based open-loop BIPV/T system produces electricity and collects heat simultaneously. Building-integrated thermal mass is utilized both in passive and active forms. Distributed thermal mass in the direct gain area and relatively large south facing triple-glazed windows (about 9% of floor area) are employed to collect and store passive solar gains. An active thermal energy storage system (TES) stores part of the collected thermal energy from the BIPV/T system, thus reducing the energy consumption of the house ground source heat pump heating system. This paper focuses on the BIPV/T system and the integrated energy concept of the house. Monitored data indicate that the BIPV/T system has a typical efficiency of about 20% for thermal energy collection, and the annual space heating energy consumption of the house is about 5% of the national average. A thermal model of the BIPV/T system suitable for preliminary design and control of the airflow is developed and verified with monitored data. (author)

14 SOLAR ENERGY↗

A comparison of building system parameters between affordable and market-rate housing in New York City

Low-income households in the United States experience higher than average energy burdens (defined as the proportion of household income spent on energy utilities), and many of these households struggle to simultaneously pay for rent, energy, and basic household necessities. The analysis presented here in this study examines whether the underlying characteristics of buildings and their energy systems could contribute to this disparity for affordable housing residents in New York City. It combines an energy audit dataset of 7,328 multifamily buildings with a database of properties receiving local, state, or federal housing subsidies. The results of this analysis indicate that the building-level installed equipment in large (greater than 50,000 square feet) affordable housing buildings in New York City is more efficient than that in market-rate buildings, but this trend largely disappears when considering overall building characteristics, such as location, size, or age. Significant differences in the types of systems installed in affordable and market-rate housing are also observed, as well as the types of energy efficiency recommendations made by energy auditors. However, these latter data were not normalized by building system characteristics, as that analysis is much more difficult to interpret for categorical data such as heating system type. These findings indicate that retrofit policies and building performance standards focused on affordable housing will likely need to account for underlying differences in building characteristics between affordable and market-rate housing to achieve intended impacts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Spatial Impacts of Electric Vehicle Charging on Power Grid Stability: A Downtown Atlanta Case Study

The rapid increase in electric vehicle (EV) charging demand poses a potential risk to power grid stability, particularly as the spatial distribution of this demand remains underexplored. Existing research often focuses on technical optimization models while overlooking the geographic and human dynamics that affect energy consumption. This study addresses this gap by incorporating mobility data to estimate both building energy use and EV charging demand while also considering geographic factors for a better understanding of grid load. Using agent-based simulations and the Open-Source Distribution System Simulator, the study evaluates the effect of various EV penetration scenarios on grid voltage and unbalance. The results show that, although voltage remains within acceptable limits at lower EV penetration rates, significant voltage drop and unbalance occur as EV penetration exceeds 40%, particularly in residential areas with high charging demand. This study offers a framework for integrating spatial analysis and mobility data in power network simulations, providing insights for future EV infrastructure planning.

Pan, Melrose [ORNL] (ORCID:000000031627448X)↗

Learning-based framework for sensor fault-tolerant building HVAC control with model-assisted learning

As people spend up to 87% of their time indoors, intelligent Heating, Ventilation, and Air Conditioning (HVAC) systems in buildings are essential for maintaining occupant comfort and reducing energy consumption. These HVAC systems in smart buildings rely 'on real-time sensor readings, which in practice often suffer from various faults and could also be vulnerable to malicious attacks. Such faulty sensor inputs may lead to the violation of indoor environment requirements (e.g., temperature, humidity, etc.) and the increase of energy consumption. While many model-based approaches have been proposed in the literature for building HVAC control, it is costly to develop accurate physical models for ensuring their performance and even more challenging to address the impact of sensor faults. In this work, we present a novel learning-based framework for sensor fault-tolerant HVAC control, which includes three deep learning based components for 1) generating temperature proposals with the consideration of possible sensor faults, 2) selecting one of the proposals based on the assessment of their accuracy, and 3) applying reinforcement learning with the selected temperature proposal. Moreover, to address the challenge of training data insufficiency in building-related tasks, we propose a model-assisted learning method leveraging an abstract model of building physical dynamics. Through extensive experiments, we demonstrate that the proposed fault-tolerant HVAC control framework can significantly reduce building temperature violations under a variety of sensor fault patterns while maintaining energy efficiency.

Xu, Shichao↗

Accurate Prediction of Algal Biomass Lipid, Protein, and Carbohydrate Composition with Machine Learning Regression Modelling of Near-IR Spectra

During large scale algal biomass cultivation, it is difficult to reliably control relative composition to target levels. Rapid determination of chemical composition is feasible by using near infrared (NIR) spectral data. We sought to build and improve on reliable high-throughput screening prediction method based on partial least squares regression (PLSR) by the application of artificial neural networks (ANN) and associated optimization strategies. The algal biomass sample set was designed and created in an iterative process of culturing in physiologically diverse conditions at the GAI field site, followed by compositional analyses at NREL. The workflow allowed us to identify gaps in compositional space for informing the subsequent cultivation and sampling efforts and generated a high quality set of 210 unique samples with chemical analysis results, spectral scanning data, and cultivation metadata. We observed a significant improvement in the performance of carbohydrate content predictions using an optimized ANN model compared to PLSR, with > 16% reduction in mean absolute percent error (MAPE) when tested on the same set of reserved data. The optimized ANN models for FAME and protein prediction performed exceptionally well with 5.99% and 5.09% MAPE, respectively. Application of these methods to detection and quantification of minor biomass constituents that are relevant to certain product streams has shown positive preliminary results, opening the possibility for extensions to the outputs of this powerful data type. All models are accompanied by prediction uncertainties and unsupervised spectral outlier detection to alert an operator to unreliable spectral data. These tools can be deployed for rapid determination of algal culture status, and cultivation and biomass quality improvement.

algal biofuels↗

ResStock Measure Documentation: Cold Climate Air-Source Heat Pump

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Cold Climate Air-Source Heat Pump" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building ControlScore: General Service Administration Office Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore concept, which takes operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control). PNNL applied the Building ControlScore application to all available data from a General Services Administration office building within the period of January 1, 2023, to March 9, 2023. The building scored a 4.7 overall, with all 74 of the building’s loops fitting a roughly normal distribution centered around 5. These results indicate that the analyzed systems have below-average performance with room for improvement, especially in the poorly scored systems. Airflow loops tended to have much lower scores than zone temperature loops. The lowest and highest performing systems in the building section were identified, as were all loops with a score less than 1. While the ControlScore identifies loops and systems that aren’t meeting their designated setpoints, it does not indicate the cause of those issues. For example, consider a supply air terminal unit’s airflow loop that received a low score due to it delivering less air than specified by the setpoint. The lower-than-desired airflow could be due to equipment limitations (e.g., the terminal unit or duct serving is too small to accommodate that airflow), malfunctioning equipment (e.g., a stuck damper or bad sensor), or something else entirely. The ControlScore does not diagnose problems it simply identifies the symptoms that can be explored and addressed by building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Impacts of Data Integrity Attacks on Transactive Control Systems

With the rapid growth of internet-connected smart devices capable of exchanging energy price information and adaptively controlling energy consumption of connected loads, the role of transactive control is expected to become more prominent in the modern grid. Transactive control systems integrate the wholesale and retail energy markets, and enable active participation of end users, thereby playing a key role in managing the rising number of distributed assets in the smart grid. The use of internet for the communication of data between the controllers at the building, distribution, and transmission levels makes the system susceptible to cyber-attacks. A skilled adversary can potentially manipulate the exchanged data with the intention of inflicting damage to the system. In this paper, four categories of metrics are put forth for evaluating the performance of the system when under data integrity attacks. A model for scaling-based data integrity attack has been described, and co-simulations have been performed on a 240 bus WECC transmission system model with detailed modeling of distribution systems at specific buses. Our results show that scaling-based data integrity attacks can have non-trivial impacts on the operational, financial, and comfort aspects of the transactive control system.

Smart grid, transactive control system, Buildings-↗

Enabling immersive engagement in energy system models with deep learning

Complex ensembles of energy simulation models have become crucial components of renewable energy research in recent years. Often the increasing computational cost, high-dimensional structure, and other complexities hinder researchers from fully utilizing these data sources for knowledge building. Researchers at National Renewable Energy Laboratory have determined an immersive visualization workflow to dramatically improve user engagement and analysis capability through a combination of low-dimensional structure analysis, deep learning, and custom visualization methods. We present case studies for two energy simulation platforms.

97 MATHEMATICS AND COMPUTING↗

Crystallographic Evidence for Noncoplanar Catalytic Aspartic Acids in plasmepsin II Resides in the Protein Data Bank

The carboxylate atoms of the two catalytic aspartic acid residues in aspartic proteases are nearly coplanar and in the uncomplexed form share an in-plane nucleophilic water molecule that is central to the mechanism of these enzymes. This note reports that while reviewing the electron-density maps derived from the deposited data for uncomplexed plasmepsin II from Plasmodium falciparum (Asojo et al. (2003), J. Mol. Biol. 327, 173-181; PDB code 1lf4), it was discovered that the aspartic acid residues in this structure should in fact be distinctly noncoplanar. The crystallographic model from the deposited coordinates has been re-refined against the 1.9 {angstrom} resolution published diffraction data to an R{sub cryst} of 21.2% and an R{sub free} of 22.2%. The catalytic water molecule is present, but the plane of the carboxylate group of Asp214 is rotated by 66 degrees from its original position.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical Validation of UBEM: An Assessment of Bias in Urban Building Energy Modeling for Chicago

Residential and commercial buildings currently account for 30% of total global final energy consumption. Urban-scale building energy modeling (UBEM) can enable scalable investments and unlock building improvements by quantifying energy, demand, emissions, and cost reductions of specific measures or packages for building-specific technologies in large geographic regions. While the sophistication of UBEM data sources and technologies have increased dramatically in the past decade, there remains a knowledge gap for empirical validation and sources of bias between building-specific energy models and measured data at varying geographic scales.As UBEM continues to develop, systemic analysis of accuracy, bias, and limitations of the resulting models is necessary to inform best practices and move toward standardization. These are characterized for the Automatic Building Energy Modeling (AutoBEM) software suite with an initial case study involving metered electricity consumption data from 247,188 buildings in Chicago, Illinois, USA - averaged across years 2019-2021 - compared to the following datasets: (1) the AutoBEM-generated nation-scale Model America version 2 (MAv2) data for 596,064 buildings, (2) tax assessor data for 579,829 buildings, (3) tax assessor data filled with MAv2, and (4) 102 representative dynamic archetypes. The accuracy is reported for every building type and vintage combination, along with multiple sources of bias for unique building descriptors. The AutoBEM simulation workflow produced energy consumption estimates that closely match aggregated metered electricity consumption data for different types of buildings constructed during various time periods at the city scale - with initial normalized mean bias error of 10.9%, and 1.1% after removing outliers. Contribution of statistically significant factors including building type, land use, age, and size to variance in UBEM bias is quantified.

Garg, Ankur↗

SEEDling [SWR-20-99]

SEEDling is intended to simplify the merging of multiple data sources prior to importing into the SEED platform. Geographic information about buildings and taxlots is often obtained from various data sources, and the process of synthesizing this information for many buildings across a city can be burdensome for city data managers. SEEDling uses GIS tools to automate and simplify this process, as well as apply criteria for SEED inclusion (ex: sqft > 50k) and assign UBIDs, to create records that can be easily imported into the SEED platform.

Long, Nicholas↗

Data and scripts associated with “When do Riverine Systems 'Feel the Burn'? Simulating How Burn Extent and Severity Modulate Hydrologic Controls on Biogeochemical Export” (v2)

This data package is associated with the publication “When do Riverine Systems 'Feel the Burn'? Simulating How Burn Extent and Severity Modulate Hydrologic Controls on Biogeochemical Export” published in Water Resources Research (Wampler et al. 2025; preprint: https://doi.org/10.22541/essoar.174438106.63564767/v1). This study used the Soil and Water Assessment Tool (SWAT), a processed based model to explore the impacts of area burned and burn severity on streamflow, nitrate, and dissolved organic carbon (DOC) in two test basins: a semi-arid, mixed land use basin and a humid, primarily forested basin. We developed 1800 wildfire scenarios that we ran in each basin: 20 different burn extents (5 to 100% by 5%), 3 different burn severities (low, moderate, and high), and 30 different post-fire precipitation scenarios. We also ran an additional 30 scenarios associated with no wildfire for the 30 post-fire precipitation scenarios. For each scenario we were interested in the change in runoff ratio (streamflow) and average concentration and annual loads (nitrate and DOC) across the wildfire scenarios. This data package contains the data and scripts required to build SWAT models for the two test basins, create and run the wildfire scenarios, and generate the data summaries and figures used in the associated manuscript. This data package was originally published in March 2025. It was updated in January 2026 (v2; new and modified files) to include the final files after the manuscript went through reviews. See the change history section below for more details. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About.

54 ENVIRONMENTAL SCIENCES↗

Process–Property–Performance Mapping of Additively Manufactured 316H Stainless Steel Components

The Advanced Materials and Manufacturing Technologies Program is focused on accelerating the development of advanced materials and components fabricated via additive manufacturing, and is using laser powder bed fusion (LPBF) of 316H stainless steel as an initial case study. In the previous fiscal year, miniature high-throughput specimens were printed on multiple LPBF systems to provide initial processing windows to minimize porosity and limit epitaxial grain growth during prints. This fiscal year, scaled builds were completed on three different LPBF systems at ORNL: a GE Concept Laser M2, a Renishaw AM400, and an EOS M290. Builds on the Concept Laser were conducted on multiple powder lots and processing parameter ranges to provide microstructure effects on time-independent and time-dependent mechanical properties. Builds on the Renishaw were produced using Oak Ridge National Laboratory (ORNL)-optimized printing parameters and Argonne National Laboratory (ANL)-optimized printing parameters to compare outcomes of parallel process optimization efforts at different national laboratories on the same LPBF system. Similarly, the build completed on the EOS M290 replicated the processing parameters of builds completed at Los Alamos National Laboratory (LANL). Optical microscopy and electron backscatter diffraction characterization was completed on all builds. In addition to the general round robin characterization, this work-package generated time-independent data, including tensile and fracture toughness test data on scaled Concept Laser builds as a function of processing parameters and post-build heat treatment. This analysis is complimentary to work in parallel work packages aiming to establish heat treatment and processing effects on time-dependent properties. It was found that although the stress-relief heat treatment provides the highest strength at lower-temperatures, tensile strength begins to converge at higher temperatures regardless of heat treatment condition. In addition, the more rigorous solution annealing and hot-isostatic pressing post-build heat treatments result in higher fracture toughness than the stress-relieved condition. The root-causes of the lower fracture toughness of the stress-relieved LPBF 316H material was informed via a stress-relief optimization study on a scaled concept laser print, where it was found that although dislocation recovery was largely complete after only a couple hours at 650°C, the extended hold of the current 24h heat treatment employed on scaled builds likely caused increased carbide volume fractions along the LPBF 316H grain boundaries, thereby deteriorating crack propagation resistance. This trend was seen to become more deleterious with additional increases of stress-relief temperature to 750°C or 850°C. These results have helped inform a new optimal stress-relief annealing condition for LPBF 316H for future campaign testing (650°C for 2h).

36 MATERIALS SCIENCE↗