Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Involved-Node Proton Therapy in Combined Modality Therapy for Hodgkin Lymphoma: Results of a Phase 2 Study

Purpose: This study describes the early clinical outcomes of a prospective phase 2 study of consolidative involved-node proton therapy (INPT) as a component of combined-mode therapy in patients with stages I to III Hodgkin lymphoma (HL) with mediastinal involvement. Methods and Materials: Between September 2009 and June 2013, 15 patients with newly diagnosed HL received INPT after completing chemotherapy in an institutional review board-approved protocol comparing the dosimetric impact of PT with those of three-dimensional conformal radiation therapy (3DCRT) and intensity modulated RT. Based on {sup 18}F-Fluorodeoxyglucose positron emission tomography/computed tomography ({sup 18}F-FDG PET/CT) response, 5 children received 15 to 25.5 cobalt Gy equivalent (CGE) of INPT after receiving 4 cycles of Adriamycin, Bleomycin, Vincristine, Etoposide, Prednisone, Cyclophosphamide or Vincristine, adriamycin, methotrexate, Prednisone chemotherapy, and 10 adults received 30.6 to 39.6 CGE of INPT after 3 to 6 cycles of Adriamycin, Bleomycine, Vinblastine, Dacarbazine. Patients were routinely evaluated for toxicity during and after treatment, using Common Terminology Criteria for Adverse Events, version 3.0, and for relapse by physical examination and routine imaging. Relapse-free survival (RFS) and event-free survival (EFS) rates were calculated using the Kaplan-Meier method from the time of diagnosis. Results: The median follow-up was 37 months (range, 26-55). Two events occurred during follow-up: 1 relapse (inside and outside the targeted field) and 1 transformation into a primary mediastinal large B cell lymphoma. The 3-year RFS rate was 93%, and the 3-year EFS rate was 87%. No acute or late grade 3 nonhematologic toxicities were observed. Conclusions: Although decades of follow-up will be needed to realize the likely benefit of PT in reducing the risk of radiation-induced late effects, PT following chemotherapy in patients with HL is well-tolerated, and disease outcomes were similar to those of conventional photon therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transport-constrained extensions of collision and track length estimators for solutions of radiative transport problems

In this paper we develop novel extensions of collision and track length estimators for the complete space-angle solutions of radiative transport problems. We derive the relevant equations, prove that our new estimators are unbiased, and compare their performance with that of more conventional estimators. Such comparisons based on numerical solutions of simple one dimensional slab problems indicate the the potential superiority of the new estimators for a wide variety of more general transport problems.

97 MATHEMATICS AND COMPUTING↗

Monaco treatment planning system tools and optimization processes

The Monaco treatment planning system combines Monte Carlo dose calculation accuracy with robust optimization tools to provide high-quality radiotherapy treatment plans for three-dimensional conformal radiotherapy (3D CRT), intensity modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), stereotactic radiosurgery (SRS), and stereotactic body radiotherapy (SBRT). Recent technology advances have allowed for fast calculation speeds, which allow clinicians and patients to benefit from the accuracy of the Monte Carlo algorithm while reducing overall planning time. A collection of biological and physical dose-based planning tools and templates simplify the planning process and allow for consistent results across organizations. At the same time, multicriteria optimization (MCO) ensures critical organs are spared to the greatest possible degree while maintaining target coverage. Monaco encompasses a full suite of treatment modalities, including conventional radiotherapy and particle therapy, and is paving the way for real-time adaptive treatments with developments in magnetic resonance (MR)-guided radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evolution of stars with suppressed core convection

Stellar evolution on the upper main sequence was computed for models of stars with cores assumed to be in radiative equilibrium, up to the point of central helium ignition. The role of the Schonberg-Chandrasekhar limit for an isothermal core is found to be critical for the evolutionary tracks. Observational data are used to rule out the hypothesis of evolution with radiative cores (in upper main-sequence stars) and, by implication, of magnetic fields that are sufficiently strong to have suppressed the core convention.

Stothers, R. B.↗

Silicon Research and Technology Workshop report

The materials, structures, processing, modeling and measurements of high efficiency silicon solar cells were surveyed. In the materials area, highlights included: (1) the possibility of improving cell voltages by reducing minority carrier mobilities in critical regions of the solar cells; (2) the need for and possibility of lowering the surface recombination velocity for improvement of open circuit voltage in shallow junction cells; (3) the present need for improved lifetime in high resistivity cells; and (4) the potential for new materials such as polycrystalline or dendritic web material to perform well at end of life in a radiation environment. In the area of structures, distinction was made between those for terrestrial use and those that would survive radiation environments. Areas such as epitaxial growth and laser or elctron beam annealing (and diffusion) were proposed as having certain advantages over more conventional techniques.

Meulenberg, A., Jr.↗

Integrated-Circuit Broadband Infrared Sources

Microscopic devices consume less power, run hotter, and are more reliable. Simple, compact, lightweight, rapidly-responding reference sources of broadband infrared radiation made available by integrated-circuit technology. Intended primarily for use in calibration of remote-sensing infrared instruments, devices eventually replace conventional infrared sources. New devices also replace present generation of miniature infrared sources. Self-passivating nature of poly-crystalline silicon adds to reliability of devices. Maximum operating temperature is 1,000 K, and power dissipation is only one-fourth that of prior devices.

Lamb, G.↗

Cosmic instability from radiation pressure

The Cosmic Background Explorer has recently confirmed the blackbody character of the microwave background to high accuracy (Mather et al., 1990), and will have the capability to detect other cosmic backgrounds throughout the infrared. A detection of cosmic background radiation dating from the pregalactic era would have important consequences for theories of cosmic structure. During the creation of such a background the pressure of the radiation itself causes an instability which leads inevitably to the growth of large-scale structure in the matter distribution. In contrast to conventional gravitational-instability models, the statistical properties of this structure are determined primarily by the self-organizing dynamics of the instability rather than details of cosmological initial conditions. The behavior of the instability is described here.

Hogan, Craig J.↗

High-Output Heat-Flux Gauges

Heat-flux gauges of proposed type put out relatively large signal voltages. Thermocouples in N top-surface/bottom-surface pairs connected in series put out N times voltage of conventional (N=1) pair on insulating layer of same thickness at same heat flux. Useful in such applications as engine instrumentation and radiation-measuring equipment.

Will, Herbert A.↗

Near-Infrared Laser Pumped Intersubband THz Laser Gain in InGaAs-AlAsSb-InP Quantum Wells

We investigate the possibility of using InGaAs-AlAsSb-InP coupled quantum wells to generate THz radiation by means of intersubband optical pumping. We show that large conduction band offsets of these quantum wells make it possible to use conventional near-infrared diode lasers around 1.55 micron as pump sources. Taking into account the pump-probe coherent interaction and the optical nonlinearity for the pump field, we calculate the THz gain of the quantum well structure. We show that resonant Raman scattering enhances the THz gain at low and moderate optical pumping levels. When the pump intensity is strong, the THz gain is reduced by pump-induced population redistribution and pump-probe coherent interactions.

Liu, An-Sheng↗

Real Time In Situ Observations of Equiaxed Dendrite Coherency in Al-Cu Alloys Using High-Brilliance, 3rd Generation Synchrotron Sources

In the last decade synchrotron X-ray sources have fast become the tool of choice for performing in-situ high resolution imaging during alloy solidification. This paper presents the results of an experimental campaign carried out at the European Synchrotron Radiation Facility, using a Bridgman furnace, to monitor phenomena during solidification of Al-Cu alloys - specifically the onset of equiaxed dendrite coherency. Conventional experimental methods for determining coherency involve measuring the change in viscosity or measuring the change in thermal conductivity across the solidifying melt Conflicts arise when comparing the results of these experimental techniques to find a relationship between cooling rate and coherency fraction. It has been shown that the ratio of average velocity to the average grain diameter has an inversely proportional relationship to coherency fraction. In-situ observation therefore makes it possible to measure these values directly from acquired images sequences and make comparisons with published results.

Murphy, Andrew G.↗

A Prototype Roof Deck Designed to Self-Regulate Deck Temperature and Reduce Heat Transfer

A prototype roof and attic assembly exploits the use of radiation, convection and insulation controls to reduce the heat transfer penetrating its roof deck by almost 85% of the heat transfer crossing a conventional roof and attic assembly. The assembly exhibited attic air temperatures that did not exceed the peak day outdoor ambient temperature. The design includes a passive ventilation scheme that pulls air from the soffit and attic into an inclined air space above the deck. The design complies with fire protection codes because the air intake is internal and closed to the elements. Field data were benchmarked against an attic computer tool and simulations made for new and retrofit home constructions in hot, moderate and cold climates to access economics for the assembly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Decommissioning of a Historic Waste Storage Facility in Austria - 19059

Nuclear Engineering Seibersdorf Ltd. (NES) performed decommissioning of an old waste storage facility, the so called 'bunker', which was commissioned in 1968 and used until 1978 for the storage of radioactive waste from medical, industrial and research activities, as well as from the operation of the Austrian research reactor ASTRA. Due to the layout of the bunker the initial decommissioning plan was to decontaminate the inner walls of the caverns and afterwards perform clearance measurements on the standing structure. However, throughout the first phase of decommissioning it turned out, that contaminations penetrated deeper into the concrete structure as initially anticipated, which made an adoption of the decommissioning strategy necessary. By changing the workflow and to remove non-contaminated parts of the structure first, also the strategy for the clearance measurements had to be adapted. The selective decommissioning strategy and the demand that measurements shall be performed by an accredited body, required to set up an adequate communication structure to keep the workflow going. Moreover, a fast communication between NES, the competent authority and the authority's (external) experts was necessary to receive clearance licenses on time, and to prevent backlog of dismantled material. The paper reports on the initial and the adapted decommissioning strategy and the challenges within the changed approach. Applied decontamination and decommissioning methods and the implemented radiation protection measures will be discussed. Furthermore, information on the methodologies for clearance measurements, the collaboration of the accredited body with the decommissioning team, as well as on the communication between NES and the competent authority will be given. Finally, a balance of radioactive waste vs. conventionally disposed waste will be shown. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Photon upconversion with hot carriers in plasmonic systems

In this paper, we propose a scheme of photon upconversion based on harnessing the energy of plasmonic hot carriers. Low-energy photons excite hot electrons and hot holes in a plasmonic nanoparticle, which are then injected into an adjacent semiconductor quantum well where they radiatively recombine to emit a photon of higher energy. We theoretically study the proposed upconversion scheme using Fermi-liquid theory and determine the internal quantum efficiency of upconversion to be as high as 25% in 5 nm silver nanocubes. This upconversion scheme is linear in its operation, does not require coherent illumination, offers spectral tunability, and is more efficient than conventional upconverters.

36 MATERIALS SCIENCE↗

UV filters for lighting of plants

The wavelength dependent interaction of biological systems with radiation is commonly described by appropriate action spectra. Particularly effective plant responses are obtained for ultraviolet (UV) radiation. Excess shortwave UV-B radiation will induce genetic defects and plant damage. Besides the ecological discussion of the deleterious effects of the excess UV radiation there is increasing interest in horticultural applications of this spectral region. Several metabolic pathways leading to valuable secondary plant products like colors, odors, taste, or resulting in mechanical strength and vitality are triggered by UV radiation. Thus, in ecologically as well as in economically oriented experiments the exact generation and knowledge of the spectral irradiance, particularly near the UV absorption edge, is essential. The ideal filter 'material' to control the UV absorption edge would be ozone itself. However, due to problems in controlling the toxic and chemically aggressive, instable gas, only rather 'small ozone filters' have been realized so far. In artificial plant lighting conventional solid filter materials such as glass sheets and plastic foils (celluloseacetate or cellulosetriacetate) which can be easily handled have been used to absorb the UV-C and the excess shortwave UV-B radiation of the lamp emissions. Different filter glasses are available which provide absorption properties suitable for gradual changes of the spectral UV-B illumination of artificial lighting. Using a distinct set of lamps and filter glasses an acceptable simulation of the UV-B part of natural global radiation can be achieved. The aging of these and other filter materials under the extreme UV radiation in the lamphouse of a solar simulator is presently unavoidable. This instability can be dealt with only by a precise spectral monitoring and by replacing the filters accordingly. For this reason attempts would be useful to develop real ozone filters which can replace glass filters. In any case chamber experiments require a careful selection of the filter material used and must be accompanied by a continuous UV-B monitoring.

Doehring, T.↗

Advances in detection for neutron reflectometry with time-resolved imaging detectors

Thermal neutron detection in neutron scattering science is a challenging endeavour due to a limited number of technologies which are sensitive to these weakly interacting particles. While many improvements to conventional detectors are underway at various facilities, there is a great opportunity to make a leap in performance by combining the spatial resolution benefits of imaging and the temporal resolution and background discrimination of event-driven radiation detectors. This idea has been realized by using a neutron sensitive scintillator read out by a single-photon sensitive camera based on a Timepix3 ASIC. We demonstrate how such data-driven imaging sensors can enable unprecedented performance in neutron reflectometry using the ASTERIX instrument at the Los Alamos Neutron Scattering Center. Several samples were measured with both the new and a conventional 3 He detector systems. The results from this work demonstrate that these imaging based systems can satisfy performance parameters for the future QIKR reflectometer to be built at the Second Target Station at Oak Ridge National Laboratory. Further improvements to the detector are already underway which will allow streamlined and expedited experiments. We demonstrate at least a two order of magnitude increase in detection rate at an acceptable dead time and introduce a new way of tuning the detector efficiency using light collecting optics to accommodate highly intense direct beams which cannot be measured with any current detectors without severe attenuation. This will allow measurements of complete reflectometry profiles and using a single sample measurement combined with fewer direct beam calibration measurements on QIKR and potentially other reflectometers.

36 MATERIALS SCIENCE↗

Rethinking radiation effects in materials science using the plasma-focused ion beam

This work demonstrates the viability of using a plasma-focused ion beam (PFIB) as a new platform to carry out radiation effects studies in solids. While materials subjected to irradiation in either nuclear reactors or energetic particle accelerators experience limitations with respect to inaccuracies in both flux measurements and lack of precise control of irradiation areas, we demonstrate a new irradiation technique that allows the exposure of a single specimen in multiple areas, at multiple doses, and in site-specific dependencies - all with flux variations on the order of only 1%. This versatile technique also allows materials to be exposed to significantly higher irradiation dose rates than conventional accelerators. To validate the new methodology, we selected the classical example of ion-beam-induced amorphization of pure single-crystal Si. By pioneering the use of the PFIB for radiation effects studies in materials science, we were able to exploit, in both micro- and nanometer-sized detail, the differences in electron image contrast arising from crystalline versus amorphous solid-state phases in classical semiconductors subjected to irradiation, thus providing new insights on amorphization mechanisms. This methodology opens new research frontiers at the fringe of materials science with promising applications beyond the scope of materials at extremes such as in nanopatterning, nanodevices and nanoarchitectonics.

36 MATERIALS SCIENCE↗

3D printed water-stable Cd-doped Cs 4 MnBi 2 Cl 12 /polylactic acid perovskite/polymer composites for high-flux X-ray scintillation

Stable and efficient X-ray scintillators are crucial for medical diagnostics, industrial, and defense applications. However, conventional scintillator technologies face a trade-off between stability, optimal performance, and sustainability. Herein, we introduce 3D-printed Cs 4 MnBi 2 Cl 12 (Pero1) and Cs 4 Cd 0.68 Mn 0.32 Bi 2 Cl 12 (Pero2) perovskite microcrystals embedded within a polylactic acid (PLA) polymer composite as X-ray scintillators, combining efficiency, stability, and sustainability. The orange luminescent perovskite powder phosphors exhibited poor water stability, which was successfully addressed through incorporation into PLA via filament extrusion and fused deposition modeling (FDM) 3D printing. The resulting composite films demonstrated remarkable water stability while maintaining uniform orange emission throughout the polymer matrix, as confirmed by 3D topography scanning and X-ray fluorescence mapping. Structural characterization revealed minimal chemical interaction between the perovskite and PLA matrix, with the composites retaining their crystalline properties. The PLA-Pero2 composite exhibited superior optical properties, with a photoluminescence quantum yield of 47%, nearly 17 times higher than that of PLA-Pero1 (2.8%), attributed to the effective suppression of non-radiative decay pathways through Cd 2+ doping. Under hard X-ray irradiation at synchrotron beamlines, both composites exhibited excellent radioluminescence, with emission peaks at 605 nm, a linear response across a wide X-ray flux range, and remarkable radiation stability, showing less than 3% intensity degradation after 600 seconds of continuous high-dose exposure. The PLA-Pero2 composite achieved a spatial resolution of 5 line pairs per millimeter and a contrast ratio of 0.255. These performance metrics, combined with the polymer's biodegradability and scalability through additive manufacturing, position PLA-based composites as a more sustainable alternative to conventional petroleum-based polymer scintillators for next-generation medical imaging, radiation monitoring, and industrial radiography applications.

3D Printing↗

Cumulative dose of radiation therapy of hepatocellular carcinoma patients and its deterministic relation to radiation-induced liver disease

This study aimed to investigate the relationship between dose and radiation-induced liver disease (RILD) in patients with hepatocellular carcinoma (HCC) receiving 3-dimensional conformal radiotherapy (3DCRT). Twenty-three patients with HCC who received conventional fractionated 3DCRT, including 7 who were diagnosed with classic RILD, were enrolled in this retrospective investigation. Cone-beam computed tomography (CBCT) scans were acquired at the time of treatment for each patient. The beams from each patient's treatment plan were applied to each pretreatment CBCT (the modified CBCT or mCBCT) to construct the delivered dose distribution of the day considering inter-treatment anatomy changes. The daily doses were summed together with the help of deformable image registration (DIR) to obtain the adjusted cumulative dose (D{sub adjusted}). The dose changes to the normal liver between the original planned dose (D{sub plan}) and D{sub adjusted} were evaluated by V20, V30, V40, and the mean dose to normal liver (MDTNL). Univariate analysis was performed to identify the significant dose changes. Among the 23 patients, the liver V20, V30, V40, and MDTNL showed significant differences between D{sub plan} and D{sub adjusted}, with average values of these parameters increased by 4.1%, 4.7%, 4.5%, and 3.9 Gy, respectively (p adjusted . Determination of a reconstructed D{sub adjusted} using the mCBCT scans are more accurate in predicting RILD and has the potential to reduce the risk of RILD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗