Search NASA⌕ Search

SEARCH · Search NASA

Results for “Conditional rate functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Response-coefficient method for heat-conduction transients with time-dependent inputs

A theoretical overview of the response coefficient method for heat conduction transients with time-dependent input forcing functions is presented with a number of illustrative applications. The method may be the most convenient and economical if the same problem is to be solved many times with different input-time histories or if the solution time is relatively long. The method is applicable to a wide variety of problems, including irregular geometries, position-dependent boundary conditions, position-dependent physical properties, and nonperiodic irregular input histories. Nonuniform internal energy generation rates within the structure can also be handled by the method. The area of interest is long-time solutions, in which initial condition is unimportant, and not the early transient period. The method can be applied to one dimensional problems in cartesian, cylindrical, and spherical coordinates as well as to two dimensional problems in cartesian and cylindrical coordinates.

Ceylan, Tamer↗

The Video Guidance Sensor- A Flight Proven Technology

The Video Guidance Sensor (VGS) flew on Shuttle mission STS-95 in October of 1998 to test the VGS functional characteristics on orbit. This was the second flight of the VGS, and during these two flights, both long range and short range data were gathered under a variety of lighting conditions, orbital exposure times, and temperatures. The flight experiment sensor was designed to operate from 1.5 meter range out to 110 meter range, with a field-of-view of 16 X 21 degrees. The VGS tracked its target at a 5 Hz rate and returned 6-degree-of-freedom information on the target's position and attitude relative to the sensor. The VGS was mounted in the Shuttle cargo bay, and its target was mounted on the Spartan spacecraft being carried on this mission. The VGS is a sensor designed to allow an automated vehicle to dock with a spacecraft equipped with a passive target. The VGS is a part of an Automated Rendezvous and Capture (AR&C) system being developed and tested by NASA. The orbital testing included operations with the target on the Shuttle's Remote Manipulator System (RMS) near the start of each flight of the VGS, long-range data (on the STS-95 flight) during the Shuttle rendezvous with the Spartan two days later, and some more RMS operations later in the mission. The data returned from the orbital testing included VGS diagnostics, acquisition, and tracking data, RMS positions, hand-held laser range data, tapes of the data from the VGS video camera, and orbital positioning data from the Spartan and the Shuttle to allow correlation of the VGS data with orbital best-estimate-of-truth data. The Video Guidance Sensor performed well in all phases of the testing, and the VGS is being incorporated into the ground testing of a complete automated rendezvous and docking system. Work on the development of the next generation VGS is continuing.

Howard, Richard T.↗

Higher Order, Hybrid BEM/FEM Methods Applied to Antenna Modeling

In this presentation, the authors address topics relevant to higher order modeling using hybrid BEM/FEM formulations. The first of these is the limitation on convergence rates imposed by geometric modeling errors in the analysis of scattering by a dielectric sphere. The second topic is the application of an Incomplete LU Threshold (ILUT) preconditioner to solve the linear system resulting from the BEM/FEM formulation. The final tOpic is the application of the higher order BEM/FEM formulation to antenna modeling problems. The authors have previously presented work on the benefits of higher order modeling. To achieve these benefits, special attention is required in the integration of singular and near-singular terms arising in the surface integral equation. Several methods for handling these terms have been presented. It is also well known that achieving ~he high rates of convergence afforded by higher order bases may als'o require the employment of higher order geometry models. A number of publications have described the use of quadratic elements to model curved surfaces. The authors have shown in an EFIE formulation, applied to scattering by a PEC .sphere, that quadratic order elements may be insufficient to prevent the domination of modeling errors. In fact, on a PEC sphere with radius r = 0.58 Lambda(sub 0), a quartic order geometry representation was required to obtain a convergence benefi.t from quadratic bases when compared to the convergence rate achieved with linear bases. Initial trials indicate that, for a dielectric sphere of the same radius, - requirements on the geometry model are not as severe as for the PEC sphere. The authors will present convergence results for higher order bases as a function of the geometry model order in the hybrid BEM/FEM formulation applied to dielectric spheres. It is well known that the system matrix resulting from the hybrid BEM/FEM formulation is ill -conditioned. For many real applications, a good preconditioner is required to obtain usable convergence from an iterative solver. The authors have examined the use of an Incomplete LU Threshold (ILUT) preconditioner . to solver linear systems stemming from higher order BEM/FEM formulations in 2D scattering problems. Although the resulting preconditioner provided aD excellent approximation to the system inverse, its size in terms of non-zero entries represented only a modest improvement when compared with the fill-in associated with a sparse direct solver. Furthermore, the fill-in of the preconditioner could not be substantially reduced without the occurrence of instabilities. In addition to the results for these 2D problems, the authors will present iterative solution data from the application of the ILUT preconditioner to 3D problems.

Fink, P. W.↗

A harmonic pulse testing method for leakage detection in deep subsurface storage formations

Abstract Detection of leakage in deep geologic storage formations (e.g., carbon sequestration sites) is a challenging problem. This study investigates an easy‐to‐implement frequency domain leakage detection technology based on harmonic pulse testing (HPT). Unlike conventional constant‐rate pressure interference tests, HPT stimulates a reservoir using periodic injection rates. The fundamental principle underlying HPT‐based leakage detection is that leakage modifies a storage system's frequency response function, thus providing clues of system malfunction. During operations, routine HPTs can be conducted at multiple pulsing frequencies to obtain experimental frequency response functions, using which the possible time‐lapse changes are examined. In this work, a set of analytical frequency response solutions is derived for predicting system responses with and without leaks for single‐phase flow systems. Sensitivity studies show that HPT can effectively reveal the presence of leaks. A search procedure is then prescribed for locating the actual leaks using amplitude and phase information obtained from HPT, and the resulting optimization problem is solved using the genetic algorithm. For multiphase flows, the applicability of HPT‐based leakage detection procedure is exemplified numerically using a carbon sequestration problem. Results show that the detection procedure is applicable if the average reservoir conditions in the testing zone stay relatively constant during the tests, which is a working assumption under many other interpretation methods for pressure interference tests. HPT is a cost‐effective tool that only requires periodic modification of the nominal injection rate. Thus it can be incorporated into existing monitoring plans with little additional investment.

Sun, Alexander Y.↗

Analytical and experimental studies of leak location and environment characterization for the international space station

The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to demonstrate the ability to detect NH{sub 3} coolant leaks in the ISS thermal control system. An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performance to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations (“directionality”). The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lb{sub m/}/yr. to about 1 lb{sub m}/day. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ram/wake flows and structural shadowing within low Earth orbit.

42 ENGINEERING↗

Removal of malachite green dye from aqueous solution using mesoporous silica synthesized from 1-octyl-3-methylimidazolium chloride ionic liquid

In this research, mesoporous silica was synthesized via a modified sol-gel route using 1-octyl-3-methylimidazolium chloride and was employed to remove malachite green (MG) dye from aqueous solution. Subsequently, this material was characterized and identified by different techniques such as Fourier transform infrared spectroscopy (FT-IR), N{sub 2} adsorption-desorption method, scanning electron microscopy (SEM), and thermosgravimetric analysis (TGA). Unique properties such as high surface area and pore diameter, in addition to highly reactive atoms and presence of various functional groups make the mesoporous silica possible for efficient removal of malachite green (MG). In batch experimental set-up, optimum conditions for quantitative removal of MG by mesoporous silica was attained by varying different variables such as adsorbent dosage, initial dye concentration, contact time, and pH. Optimum values were set as pH of 8.0, 0.5 g of adsorbent at contact time of 120 min. The adsorption of MG follows the pseudo-second-order rate equation. Equilibrium data fitted well with the Freundlich model at all amount of adsorbent, while maximum adsorption capacity was 5.981 mg g{sup −}1 for 0.5 g mesoporous silica synthesized in IL.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic scan control in STEM: spiral scans

Abstract Scanning transmission electron microscopy (STEM) has emerged as one of the foremost techniques to analyze materials at atomic resolution. However, two practical difficulties inherent to STEM imaging are: radiation damage imparted by the electron beam, which can potentially damage or otherwise modify the specimen and slow-scan image acquisition, which limits the ability to capture dynamic changes at high temporal resolution. Furthermore, due in part to scan flyback corrections, typical raster scan methods result in an uneven distribution of dose across the scanned area. A method to allow extremely fast scanning with a uniform residence time would enable imaging at low electron doses, ameliorating radiation damage and at the same time permitting image acquisition at higher frame-rates while maintaining atomic resolution. The practical complication is that rastering the STEM probe at higher speeds causes significant image distortions. Non-square scan patterns provide a solution to this dilemma and can be tailored for low dose imaging conditions. Here, we develop a method for imaging with alternative scan patterns and investigate their performance at very high scan speeds. A general analysis for spiral scanning is presented here for the following spiral scan functions: Archimedean, Fermat, and constant linear velocity spirals, which were tested for STEM imaging. The quality of spiral scan STEM images is generally comparable with STEM images from conventional raster scans, and the dose uniformity can be improved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Variable Saturation Hydraulic Conductivity Method for Improving Soil Water Content Simulation in EPIC and APEX Models

Core Ideas We propose VSHC for calculating soil water percolation in continuous models. VSHC relates permeability to daily hydraulic properties to estimate hydraulic conductivity. VSHC performed well at field scale and improved estimates of peak streamflows. Soil water percolation is a key process in the life cycle of water in fields, watersheds, and river basins. The Environmental Policy Integrated Climate (EPIC) and the Agricultural Policy/Environmental eXtender (APEX) are continuous models developed for evaluating the environmental effects of agricultural management. Traditionally, these models have simulated soil water percolation processes using a tipping‐bucket approach, with the rate of flow limited by the saturated hydraulic conductivity. This simple approach often leads to inaccuracy in simulating elevated soil water conditions where soil water content (SWC) levels may remain above field capacity under prolonged wet weather periods or limited drainage. To overcome this deficiency, a new submodel, the variable saturation hydraulic conductivity (VSHC) method, was developed for simulating soil water percolation processes using a nonlinear equation to estimate the effective hydraulic conductivity as a function of the SWC and soil properties. The VSHC method was evaluated at three sites in the United States and two sites in Europe. In addition, a numerical solution of the Richards equation was used as a benchmark for SWC comparison. Results show that the VSHC method substantially improves the accuracy of the SWC simulation in long‐term simulations, particularly during wet periods. At the watershed scale, results on the Riesel Y2 watershed indicate that the VSHC method enhances model performance in the high‐flow regime of channel peak flows because of the improved estimation of SWC, which implies that the improved SWC simulation at the field scale is beneficial to hydrologic modeling at the watershed scale.

Doro, Luca↗

THE ROLE OF NITROGEN IN TITAN’S UPPER ATMOSPHERIC HYDROCARBON CHEMISTRY OVER THE SOLAR CYCLE

Titan’s thermospheric photochemistry is primarily driven by solar radiation. Similarly to other planetary atmospheres, such as Mars’, Titan’s atmospheric structure is also directly affected by variations in the solar extreme-UV/UV output in response to the 11-year-long solar cycle. Here, we investigate the influence of nitrogen on the vertical production, loss, and abundance profiles of hydrocarbons as a function of the solar cycle. Our results show that changes in the atmospheric nitrogen atomic density (primarily in its ground state N({sup 4}S)) as a result of photon flux variations have important implications for the production of several minor hydrocarbons. The solar minimum enhancement of CH{sub 3}, C{sub 2}H{sub 6}, and C{sub 3}H{sub 8}, despite the lower CH{sub 4} photodissociation rates compared with solar maximum conditions, is explained by the role of N({sup 4}S). N({sup 4}S) indirectly controls the altitude of termolecular versus bimolecular chemical regimes through its relationship with CH{sub 3}. When in higher abundance during solar maximum at lower altitudes, N({sup 4}S) increases the importance of bimolecular CH{sub 3} + N({sup 4}S) reactions producing HCN and H{sub 2}CN. The subsequent remarkable CH{sub 3} loss and decrease in the CH{sub 3} abundance at lower altitudes during solar maximum affects the overall hydrocarbon chemistry.

79 ASTRONOMY AND ASTROPHYSICS↗

Flux divergence of thermal radiation within stratiform clouds

A longwave radiative transfer model based on the narrow-band transmission functions of Lowtran 6 has been developed to investigate the profile of radiative flux divergence at the tops of stratiform clouds. The model has a vertical resolution of 1 m and a spectral resolution of 20/cm. These features are shown to permit modeling of broadband radiative transfer in the presence of a cloud top inversion and finite liquid water gradient. Radiative cooling rates in excess of 40 K/hr are shown to be possible for extreme conditions, with values of 10 K/hr being representative of more typical conditions. The values obtained are shown to be strongly influenced by the magnitude of liquid water concentration, by the gradient of liquid water in the top 50 m, and by the strength of the temperature inversion.

Davies, Roger↗

Effects of heat stress on baroreflex function in humans

INTRODUCTION: Heat stress significantly reduces orthostatic tolerance in humans. The mechanism(s) causing this response remain unknown. The purpose of this review article is to present data pertaining to the hypothesis that reduced orthostatic tolerance in heat stressed individuals is a result of heat stress induced alterations in baroflex function. METHODS: In both normothermic and heat stressed conditions baroreflex responsiveness was assessed via pharmacological and non-pharmacological methods. In addition, the effects of heat stress on post-synaptic vasoconstrictor responsiveness were assessed. RESULTS: Generally, whole body heating did not alter baroreflex sensitivity defined as the gain of the linear portion of the baroreflex curve around the operating point. However, whole body heating shifted the baroreflex curve to the prevailing (i.e. elevated) heart rate and muscle sympathetic nerve activity. Finally, the heat stress impaired vasoconstrictor responses to exogenous administration of adrenergic agonists. CONCLUSION: Current data do not support the hypothesis that reduced orthostatic tolerance associated with heat stress in humans is due to impaired baroreflex responsiveness. This phenomenon may be partially due to the effects of heat stress on reducing vasoconstrictor responsiveness.

Review, Tutorial↗

Analytical and Experimental Studies of Leak Location and Environment Characterization for the International Space Station

The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to detect NH3 coolant leaks in the ISS thermal control system. An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performance to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations ("directionality"). The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lb-mass/yr. to about 1 lb-mass/day. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ram/wake flows and structural shadowing within low Earth orbit.

000000↗

Using Mylar-Insulated Cryopumping Panels to Improve Vacuum Level During Warm Temperature Testing at JSC's Large Thermal Vacuum Facilities

Johnson Space Center’s Space Environment Simulation Lab (SESL) has both Chamber A, the world’s largest purpose-built thermal vacuum chamber capable of creating deep space conditions, and Chamber B, the largest human rated thermal vacuum chamber. A unique design feature of these chambers is the gaseous helium cryopumping panels within the liquid nitrogen shroud. This shroud is used to bring the chamber to cryogenic temperatures while the cryopumping panels trap gasses on its surface area to create a high vacuum environment of 5*10-6 Torr. In preparation for the James Webb Space Telescope (JWST) flight test, a series of functionals required the chamber to run at higher temperatures, and therefore did not need active cooling from the liquid nitrogen shroud. During testing, cryopumping panels were used to mitigate contamination during this main shroud warm-up. One of the cryopumping panels in Chamber A was covered with several layers of aluminized mylar to thermally protect the zone from the warmed shroud. This strategy was effective and became part of operations during JWST testing. Currently, Chamber B has requests for both commercial and NASA space suit tests at both high and low temperatures to validate thermal models. High temperature tests could benefit from reduced heater demand with an insulated shroud while still sustaining the high vacuum environment provided by the cryopumping panels. This paper will quantitatively define the thermal loads on the panels used in previous Chamber A warm up sequences. Additionally, this report will perform thermal analyses to assess the feasibility of adding layers of aluminized mylar to the cryopumping panels of Chamber B.

Cryogenics↗

Atmospheric turbulence affects wind turbine nacelle transfer functions

Despite their potential as a valuable source of individual turbine power performance and turbine array energy production optimization information, nacelle-mounted anemometers have often been neglected because complex flows around the blades and nacelle interfere with their measurements. This work quantitatively explores the accuracy of and potential corrections to nacelle anemometer measurements to determine the degree to which they may be useful when corrected for these complex flows, particularly for calculating annual energy production (AEP) in the absence of other meteorological data. Using upwind meteorological tower measurements along with nacelle-based measurements from a General Electric (GE) 1.5sle model, we calculate empirical nacelle transfer functions (NTFs) and explore how they are impacted by different atmospheric and turbulence parameters. This work provides guidelines for the use of NTFs for deriving useful wind measurements from nacelle-mounted anemometers. Corrections to the nacelle anemometer wind speed measurements can be made with NTFs and used to calculate an AEP that comes within 1% of an AEP calculated with upwind measurements. We also calculate unique NTFs for different atmospheric conditions defined by temperature stratification as well as turbulence intensity, turbulence kinetic energy, and wind shear. During periods of low stability as defined by the Bulk Richardson number ( R B ), the nacelle-mounted anemometer underestimates the upwind wind speed more than during periods of high stability at some wind speed bins below rated speed, leading to a steeper NTF during periods of low stability. Similarly, during periods of high turbulence, the nacelle-mounted anemometer underestimates the upwind wind speed more than during periods of low turbulence at most wind bins between cut-in and rated wind speed. Based on these results, we suggest different NTFs be calculated for different regimes of atmospheric stability and turbulence for power performance validation purposes.

17 WIND ENERGY↗

Injection data analysis using material balance time for CO 2 storage capacity estimation in deep closed saline aquifers

Estimating the ultimate storage capacity of deep saline aquifers is important to address the formation potential to store the envisioned large volumes of CO 2 . Injection data (i.e. injection rate, bottomhole pressure, and cumulative injected volume of CO 2 ) are routinely recorded during storage operations. These data contain valuable information on the subsurface (e.g. the reservoir pore volume and the formation storage capacity) that can be extracted. In this paper, we present a two-step graphical technique to infer the pore volume and the ultimate storage capacity of closed saline aquifers by analyzing the available injection data. First, the pore volume is inferred through adapting the concept of the material balance time. Material balance time is an approximate superposition time function developed to interpret production data from oil and gas wells operating at variable pressure/rate conditions during the boundary-dominated flow period. Using material balance techniques, the ultimate storage capacity is then estimated through linear extrapolation of the average pressure trend to the maximum allowable pressure the formation can withstand. The average pressure is not available in practice, but is can be obtained from the injection data. Two approaches are presented in this study to calculate the average pressure; namely the rigorous and the approximate approaches. Unlike the rigorous approach, the approximate approach does not require a prior knowledge of some reservoir properties (e.g. relative permeability, absolute permeability, formation porosity and thickness) to calculate the average pressure. To investigate its potential and reliability in analyzing CO 2 injection data, the proposed technique is applied to four synthetic cases representing different well operating conditions. Results indicate that the approximate approach consistently overestimates the actual (simulated) storage capacity as compared to the rigorous approach. The agreement - between the inferred and the simulated reservoir pore volume, and between the analytical and numerical estimates of storage capacity - validates the potential application of the technique to CO 2 storage in closed saline aquifers. The technique is further substantiated through application to a field data set utilized from a commercial-scale geological storage (CGS) project. Finally, field data interpretation shows that the proposed technique can be utilized to identify the degree of hydraulic continuity and reservoir compartmentalization within a target formation by interpreting the corresponding pressure and rate responses.

02 PETROLEUM↗

Single-Molecule Interfacial Electron Transfer

This project is focused on the use of single-molecule high spatial and temporal resolved techniques to study molecular dynamics in condensed phase and at interfaces, especially, the complex reaction dynamics associated with electron and energy transfer rate processes. The complexity and inhomogeneity of the interfacial ET dynamics often present a major challenge for a molecular level comprehension of the intrinsically complex systems, which calls for both higher spatial and temporal resolutions at ultimate single-molecule and single-particle sensitivities. Combined single-molecule spectroscopy and electrochemical atomic force microscopy approaches are unique for heterogeneous and complex interfacial electron transfer systems because the static and dynamic inhomogeneities can be identified and characterized by studying one molecule at a specific nanoscale surface site at a time. The goal of our project is to integrate and apply these spectroscopic imaging and topographic scanning techniques to measure the energy flow and electron flow between molecules and substrate surfaces as a function of surface site geometry and molecular structure. We have been primarily focusing on studying interfacial electron transfer under ambient condition and electrolyte solution involving both single crystal and colloidal TiO 2 and related substrates. The resulting molecular level understanding of the fundamental interfacial electron transfer processes will be important for developing efficient light harvesting systems and broadly applicable to problems in fundamental chemistry and physics. We have made significant advancement on deciphering the underlying mechanism of the complex and inhomogeneous interfacial electron transfer dynamics in dyesensitized TiO 2 nanoparticle systems that strongly involves with and regulated by molecule-surface interactions. We have studied interfacial electron transfer on TiO 2 nanoparticle surfaces by using ultrafast single-molecule spectroscopy and electrochemical AFM metal tip scanning microscopy, focusing on understanding the interfacial electron transfer dynamics at specific nanoscale electron transfer sites with high-spatially and temporally resolved topographic-and-spectroscopic characterization at individual molecule basis, characterizing single-molecule rate processes, reaction driving force, and molecule-substrate electronic coupling. One of the most significant characteristics of our new approach is that we are able to interrogate the complex interfacial electron transfer dynamics by actively pin-point energetic manipulation of the surface interaction and electronic couplings, beyond the conventional excitation and observation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Comprehensive Understanding of the Aging Effects of Extreme Fast Charging on High Ni NMC Cathode

As the battery industry shifts toward high Ni content cathodes, such as LiNi 0.8 Mn 0.1 Co 0.1 O 2 [NMC811], a complete understanding of the degradation mechanisms of NMC811 under extreme fast charging (XFC) (XFC, ≤10–15 min charging) conditions is needed. Such comprehensive understanding would identify the most critical materials gaps that need to be addressed for enabling XFC long-life cells for electric vehicles. This study maps out the key aging mechanisms for NMC811 cycled at different XFC conditions (between 1C and 9C) for up to 1000 cycles. To acquire a fundamental understanding of utilization and degradation, cells are evaluated using a range of electrochemical techniques, and multimodal and multiscale microscopy techniques to quantify chemical, structural, and crystallographic degradation as a function of cycling conditions for the NMC cathode. When comparing NMC811 to NMC532, it is observed that NMC811 has a greater subsurface crystallographic degradation and displays a similar magnitude of subparticle cracking. However, the NMC811 maintains superior performance despite those advanced degradations. Here, the superior cycle life performance is attributed to the NMC811 particles having radially oriented grains and improved transport properties. NMC811 shows between 4.6× and 3.15× reduction in capacity fade than NMC532 for charging rates between 4C (e.g., 15-min charging) and 6C (10-min charging).

25 ENERGY STORAGE↗