Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed Power Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Bimodal particle distributions with increased thermal conductivity for solid particles as heat transfer media and storage materials

Solid particles are being considered in several high temperature thermal energy storage systems and as heat transfer media in a variety of advanced power generation systems, particularly in concentrated solar power plants. The downside of such an approach is the low overall heat transfer coefficients caused by the inherently low thermal conductivity values of the low-cost solid media when coupled to heat exchanger for the power cycle working fluid. Choosing the right particle size distribution, emittance, and material of the solid media can all make a substantial difference in packed bed thermal conductivity. Current research though exclusively focuses on continuous unimodal distributions of particles. Here, in this work, we propose the use of a binary particle system with a bimodal size distribution to significantly increase packed bed thermal conductivity by reducing packed bed porosity. This is the first study related to ceramic solid particle heat transfer that has considered the thermal conductivity of non-unimodal size distributions at room and elevated temperatures. The following study found that for the binary particle system using Carbo particles CP 16/30 – CP 70/140 where the large particle volume fraction was 50% there was an 17–47% increase in packed bed thermal conductivity when compared with a nearly unimodal particle size distribution of CP 16/30 between 50 and 300 °C. Two different porosity and effective thermal conductivity models were studied, with one providing better prediction of porosity but both effective thermal conductivity models providing less predictive capacity. Importantly this approach can have a substantial impact of thermal performance, with little to no impact on the particle cost.

36 MATERIALS SCIENCE↗

Photovoltaic Inverter Momentary Cessation: Recovery Process is Key

Momentary cessation refers to an inverter control mode. When the inverter terminal voltage falls below (or exceeds) a certain level, the inverter ceases to output any current, but attempts to maintain (or quickly regain) phase-locked loop synchronization to allow for quick reinjection of current when the voltage recovers to a certain point. This paper presents a photovoltaic (PV) momentary cessation model developed in PSS/E. Simulations are presented for a high voltage transmission line fault contingency in the Hawaiian island of Oahu power system on a validated PSS/E model, modified to include a custom distributed PV inverter model, and different near-future distributed PV penetration levels. Simulations for the island power system include different penetration levels of PV, and different recovery times (ramp rates and delays) after momentary cessation. The results indicate that during low voltage events, such as faults, momentary cessation can produce severe under frequency events, causing significant load shed and shortly thereafter, in some cases, over frequency events that cause generation to trip offline. The problem is exacerbated with higher penetration levels of PV. If momentary cessation is used (as is typically the case for distribution-connected resources), the recovery process after momentary cessation should be carefully considered to minimize impacts to bulk power system stability.

14 SOLAR ENERGY↗

Data efficiency assessment of generative adversarial networks in energy applications

This study investigates the data requirements of generative artificial intelligence (AI), particularly generative adversarial networks (GANs), for reliable data augmentation in energy applications. Generative AI, though seen as a solution to data limitations, requires substantial data to learn meaningful distributions—a challenge often overlooked. This study addresses the challenge through synthetic data generation for critical heat flux (CHF) and power grid demand, focusing on renewable and nuclear energy. Two variants of GAN employed are conditional GAN (cGAN) and Wasserstein GAN (wGAN). Our findings include the strong dependency of GAN on data size, with performance declining on smaller datasets and varying performance when generalizing to unseen experiments. Mass flux and heated length significantly influence CHF predictions. wGAN is more robust to feature exclusion, making it suitable for constrained synthetic data generation. In energy demand forecasting, wGAN performed well for solar, wind, and load predictions. Longer lookback hours and larger datasets improved predictions, especially for load power. Seasonal variations posed challenges, with wGAN achieving a relatively high error of Root Mean Squared Error (RMSE) of 0.32 for load power prediction, compared to RMSE of 0.07 under same-season conditions. Feature exclusions impacted cGAN the most, while wGAN showed greater robustness. This study concludes that, while generative AI is effective for data augmentation, it requires substantial data and careful training to generate realistic synthetic data and generalize to new experiments in engineering applications.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Life Cycle Emissions Factors for Electricity Generation Technologies

This dataset consists of a table containing the distribution of literature estimates of greenhouse gas emissions for the following electricity generation and storage technologies: biopower, coal, concentrating solar power, geothermal, hydrogen storage, hydropower, lithium-ion battery storage, natural gas, nuclear, ocean, oil, photovoltaic, pumped-storage hydropower, and wind. Quartile estimates of life cycle emissions factors in units of grams of carbon dioxide equivalent per kilowatt hour of generation (g CO2e/kWh) are provided for the following life cycle stages: one-time upstream, ongoing combustion, ongoing non-combustion, one-time downstream, and total. Literature estimates were compiled by the LCA Harmonization study and subsequent updates, as detailed in the factsheet which accompanies this dataset, https://www.nlr.gov/docs/fy21osti/80580.pdf .

01 COAL, LIGNITE, AND PEAT↗

On the origin of the infrared and X-ray continua of active galactic nuclei

The continuum spectra of radio-quiet active galactic nuclei, which are steeper in the near-IR and flatter in the X-ray regime, can be produced in a synchrotron self-Compton model with a broken power law electron distribution that is flat at low, and steep at large, Lorentz factor values. While the steeper part generates the IR spectrum via synchrotron process, both parts together produce the flatter X-ray spectrum via Compton scattering. The intersection of the two spectra corresponds to equipartition between the magnetic field and synchrotron photon energy densities, giving approximately the same luminosities in the synchrotron and Compton components. The photon spectra are self-consistently computed here, taking the effects of cooling, e(+)e(-) pair production, and higher order Compton scattering into account.

Zdziarski, A. A.↗

Space station automation of common module power management and distribution

The purpose is to automate a breadboard level Power Management and Distribution (PMAD) system which possesses many functional characteristics of a specified Space Station power system. The automation system was built upon 20 kHz ac source with redundancy of the power buses. There are two power distribution control units which furnish power to six load centers which in turn enable load circuits based upon a system generated schedule. The progress in building this specified autonomous system is described. Automation of Space Station Module PMAD was accomplished by segmenting the complete task in the following four independent tasks: (1) develop a detailed approach for PMAD automation; (2) define the software and hardware elements of automation; (3) develop the automation system for the PMAD breadboard; and (4) select an appropriate host processing environment.

Miller, W.↗

Paths to Sustainable Distributed Generation through 2050: Matching Local Waste Biomass Resources with Grid, Industrial, and Community Needs

This project identifies and evaluates current and future organic waste fuel types and matches these wastes with local grid, industrial, building power, and thermal energy needs. The team developed data on organic waste streams and thermal energy needs, and then constructed a techno-economic analysis model that can process the data and compute viable production of electricity, waste heat, biogas, and/or biomethane for a range of energy price points. Scenarios generated by the model include allocation of local organic waste streams to existing or new conversion infrastructure and are evaluated in a life-cycle assessment model to determine local and global environmental impacts. The project’s webbased tool provides rapid evaluation of potential waste-to-energy sites, including retrofits/expansions of existing facilities or entirely new construction, on the basis of resource availability, potential for waste heat use, and economic and environmental metrics.

09 BIOMASS FUELS↗

Distributed Learning of Mode Shapes in Power System Models

We address the problem of distributed estimation of eigenvectors for power system models using online phasor measurements. The power system is considered to be divided into a set of non-overlapping areas, each of which is equipped with a local estimator. Online measurements of bus voltage and current phasors are first used to generate estimates of the generator states in each area using decentralized Kalman filters. Thereafter, these estimates are used for identifying a reduced-order model of the system in a completely distributed way by sharing state information between the estimators over a strongly connected communication graph. The identified model is then utilized to estimate its right eigenvectors over the same distributed graph. Results are validated using a 50-bus power system model with four areas.

Gusrialdi, Azwirman↗

Distributed Solar Quality and Safety in India: Key Challenges and Potential Solutions

The quality and safety of solar systems and their installation has become a concern for investors, regulators, consumers, and Discoms in India. The push for low prices and lack of quality standards are driving project developers to install low quality products, with poor system design and execution on-site. Existing literature and stakeholder interviews point to the rampant use of low quality, sub-standard solar products in India. These products deliver less energy than expected, or have high detrition rates, or have lower product life–all of which are serious issues for developers whose return on investment depend on the amount of power generation from these solar systems for the expected life of the project. Equipment which does not conform to the minimum quality standards also creates safety risks for the distribution network. Performance and safety concerns lower investor and consumer confidence in solar products with the potential to threaten market development. This report formulates a set of recommendations to concerned authorities in India to improve the quality and safety of rooftop solar systems. Primary and secondary sources are employed to understand the current solar quality and safety scenario in India to provide the basis for future recommendations. An overview of international experiences and lessons learned on solar quality and safety issues is also conducted to understand potential solutions for India.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical Energy Storage Factual Status Document: Resource Document for the Workshop on Basic Research Needs for Next Generation Electrical Energy Storage, March 2017

Electrical energy storage is of growing importance to energy – with increasing use in transportation and on the electrical grid. Batteries are used in all types of vehicles, but have increased in importance with the growth of hybrid and all-electric powered vehicles. For the electrical grid, batteries have a wide diversity of applications from grid stability to storage of electricity generated when the load is low so it is available when there is more demand. Distributed generation of electricity by solar panels and wind generation are also drivers for enhanced energy storage. In both industries, a key enabler will be low-cost batteries with long life, excellent safety, and superior performance. In addition to these two big markets, consumer electronics powered by rechargeable batteries continues to grow into new areas with the advent of wearable technology, internet-of-things, and virtual reality. Today’s energy storage technologies fall far short of the requirements for many of these growing applications. Because of these technology gaps, advances in energy storage are expected to play a critical role for a secure energy future. This document was produced in preparation for a Department of Energy (DOE) Office of Basic Energy Sciences Workshop titled “Basic Research Needs for Next Generation Electrical Energy Storage.” This workshop will identify key basic research directions that could provide revolutionary breakthroughs needed for meeting future requirements for electrical energy storage. This document was intended to provide a high-level assessment of current technologies used for electrical storage—focusing specifically on batteries and electrochemical capacitors—and to define requirements that are foreseen for the future application of these technologies in transportation vehicles, stationary storage applications, and consumer electronics. Thus, it provides a common background for the workshop participants and sets the technological basis for the workshop.

25 ENERGY STORAGE↗

REopt/Microgrid Analysis (CRADA Final Report)

NREL is the only DOE national laboratory solely dedicated to advancing energy efficiency (EE) and renewable energy (RE) technologies and applications. Since its inception, NREL has supported both the public and the private sectors in implementing EE and RE systems and strategies to lower energy use and to meet remaining energy needs with resources having minimal environmental impact. NREL is now a sought-after resource for EE, RE, and energy systems integration expertise. CU Boulder is a public university located in Boulder, Colorado, with over 30,000 students. CU is committed to environmental sustainability and is interested in partnering with NREL to explore opportunities for RE on campus and evaluate an RE microgrid. The goal of this project is to assess the technical and economic potential for RE generation at CU and evaluate how RE may be incorporated as part of a microgrid to increase energy resiliency on campus.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced Distributed Solar Photovoltaic Deployment via Barrier Mitigation or Removal in the Western Interconnection (Final Technical Report)

In 2017, the Western Electricity Coordinating Council (WECC) 2026 Common Case projected that distributed solar PV deployment in the Western U.S. would meet or exceed 16,106 MW of installed capacity by 2026. Of this total, 12,218 MW was projected to be deployed in California and another 3,888 MW was projected to be deployed across Arizona, Colorado, Idaho, Montana, Nevada, New Mexico, Oregon, Utah, Washington, and Wyoming. However, WIEB recognized that barriers to distributed solar PV deployment could cause the region to fall short of these projections. WIEB identified three types of perceived barriers that might interfere with the deployment of distributed solar PV generation in the West, including: (1) interconnection barriers; (2) utility rate-design barriers; and (3) reliability barriers.

14 SOLAR ENERGY↗

Solar Radiation Research Laboratory (SRRL) Core Project Final Report: Fiscal Years 2022-2024

The Solar Radiation Research Laboratory (SRRL) at the National Laboratory of the Rockies (NLR) is a world-leading solar calibration and measurement facility and maintains and disseminates the World Radiation Reference (essentially the W/m2) for the United States that is essential for traceable and accurate measurements of solar radiation at all solar generation facilities. SRRL operates two calibration facilities that meet International Standards Organization-17025 (ISO-17025) standards and provide unique high-quality calibrations to NREL and other U.S. Department of Energy laboratories. The Baseline Measurement System (BMS) at SRRL provides a high-quality record of solar irradiance and surface meteorological conditions. SRRL capabilities are used to develop (1) improved methods for the calibration of solar radiometers; (2) new standards through the ISO, the International Electrotechnical Commission (IEC), and the American Standards for Testing of Materials (ASTM) International; (c) solar radiation and meteorological models; and (d) advanced instrumentation and methods for operating solar measurement stations. The SRRL datasets are also critical for the validation of new models and datasets, such as the National Solar Radiation Database (NSRDB). The research and development of solar radiation measurement systems and resource modeling techniques are essential for advancing the scientific basis for producing reliable resource data. Specifically, the spatial, temporal, and spectral (wavelength dependency) characteristics of the solar resource are required in several different time frames for various project phases.

14 SOLAR ENERGY↗

Guest Editorial High Performance Computing (HPC) Applications for a More Resilient and Efficient Power Grid

The power grid has been evolving over the last 120 years, but it is seeing more changes in this decade and next than it has seen over the past century. In particular, the widespread deployment of intermittent renewable generation, smart loads and devices, hierarchical and distributed control technologies, phasor measurement units, energy storage, and widespread usage of electric vehicles will require fundamental changes in methods and tools for the operation and planning of the power grid. The resulting new dynamic and stochastic behaviors will demand the inclusion of more complexity in modeling the power grid. Solving such complex models in the traditional computing environment will be a major challenge. Along with the increasing complexity of power system models, the increasing complexity of smart grid data further adds to the prevailing challenges. In this environment, the myriad of smart sensors and meters in the power grid increase by multiple orders of magnitude, so do the volume and speed of the data. The information infrastructure will need to drastically change to support the exchange of enormous amounts of data as smart grid applications will need the capability to collect, assimilate, analyze and process the data, to meet real-time grid functions. High performance computing (HPC) holds the promise to enhance these functions, but it is a great resource that has not been fully explored and adopted for the power grid domain.

Huang, Zhenyu Henry↗

Performance Evaluation of Next-Generation Grid Automation and Controls with High PV Penetration

This paper presents a hardware-in-the-loop (BIL) simulation to evaluate the performance of an advanced grid automation architecture, referred to as data-enhanced hierarchical control (DEHC), in achieving voltage regulation and conservation voltage reduction (CVR) in distribution networks with very high photovoltaic (PV) generation. This architecture comprises an advanced distribution management system (ADMS), a distributed energy resource management system (DERMS), and grid-edge devices working synergistically to provide the grid benefits. The HIL setup used for the evaluation includes ADMS, DERMS, and grid-edge devices. The DEHC performance is evaluated in two representative scenarios considering loose and tight constraints of the power factor at the substation. The results show that the DEHC architecture is effective in achieving voltage regulation and CVR and thus enables the grid integration of high levels of PV generation.

ADMS↗

Distributed Intrusion Detection System using Semantic-based Rules for SCADA in Smart Grid

Cyber-physical system (CPS) security for the smart grid enables secure communication for the SCADA and wide-area measurement system data. Power utilities world-wide use various SCADA protocols, namely DNP3, Modbus, and IEC 61850, for the data exchanges across substation field devices, remote terminal units (RTUs), and control center applications. Adversaries may exploit compromised SCADA protocols for the reconnaissance, data exfiltration, vulnerability assessment, and injection of stealthy cyberattacks to affect power system operation. In this paper, we propose an efficient algorithm to generate robust rule sets. We integrate the rule sets into an intrusion detection system (IDS), which continuously monitors the DNP3 data traffic at a substation network and detects intrusions and anomalies in real-time. To enable CPS-aware wide-area situational awareness, we integrated the methodology into an open-source distributed-IDS (D-IDS) framework. The D-IDS facilitates central monitoring of the detected anomalies from the geographically distributed substations and to the control center. The proposed algorithm provides an optimal solution to detect network intrusions and abnormal behavior. Different types of IDS rules based on packet payload, packet flow, and time threshold are generated. Further, IDS testing and evaluation is performed with a set of rules in different sequences. The detection time is measured for different IDS rules, and the results are plotted. All the experiments are conducted at Power Cyber Lab, Iowa State University, for multiple power grid models. After successful testing and evaluation, knowledge and implementation are transferred to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault Response of Distributed Energy Resources Considering the Requirements of IEEE 1547-2018

Inverter-based DER responses to faults on the electric power system are different than those of conventional generators and are often poorly understood. Inverter fault responses are largely software-defined, within physics-based constraints. DERs are regulated by standards and grid codes that also constrain their responses. Though fault response of DERs will vary widely, for any DER following any particular standard, a pattern of fault response can be synthesized by observing that particular standard. In this paper, the recently published IEEE 1547-2018 is examined to explore the general fault response of any DER that follows IEEE 1547-2018. Additionally, an IEEE 1547-2018 compliant inverter model is developed and tested in simulation to find the fault response, and that response is compared with the fault response of a commercial off-the-shelf inverter.

41 EE - Solar Energy Technologies Office (EE-4S)↗