Search NASA⌕ Search

SEARCH · Search NASA

Results for “EVAPORATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Development of a household waste treatment subsystem, volume 1

The domestic waste treatment subsystem was developed to process the daily liquid and non-metallic solid wastes provided by a family of four people. The subsystem was designed to be connected to the sewer line of a household which contained water conservation features. The system consisted of an evaporation technique to separate liquids from solids, an incineration technique for solids reduction, and a catalytic oxidizer for eliminating noxious gases from evaporation and incineration processes. All wastes were passed through a grinder which masticated the solids and deposited them in a settling tank. The liquids were transferred through a cleanable filter into a holding tank. From here the liquids were sprayed into an evaporator and a spray chamber where evaporation occurred. The resulting vapors were processed by catalytic oxidation. Water and latent energy were recovered in a combination evaporator/condenser heat exchanger. The solids were conveyed into an incinerator and reduced to ash while the incineration gases were passed through the catalytic oxidizer along with the processed water vapor.

Gresko, T. M.↗

A comparative study of the effects of albedo change on drought in semi-arid regions

Numerical simulation studies of the effects of changes in albedo on rainfall involve comparisons of semiarid areas, lying at the boundary between a major desert and an adjacent monsoonal region, with areas of the same size located within the monsoonal region itself. The sensitivity of the rainfall to the ground hydrology was determined by performing the albedo simulations with two different evapotranspiration parameterizations, one giving too high evaporation over land and the other giving negligible evaporation over land. The evaporation rate is, in general, found to have as important an effect as changes in albedo. The mechanism by which an increase of albedo reduces the rainfall during conditions of high evaporation is considered.

Charney, J.↗

Survey of ion plating sources

Ion plating is a plasma deposition technique where ions of the gas and the evaporant have a decisive role in the formation of a coating in terms of adherence, coherence, and morphological growth. The range of materials that can be ion plated is predominantly determined by the selection of the evaporation source. Based on the type of evaporation source, gaseous media and mode of transport, the following will be discussed: resistance, electron beam sputtering, reactive and ion beam evaporation. Ionization efficiencies and ion energies in the glow discharge determine the percentage of atoms which are ionized under typical ion plating conditions. The plating flux consists of a small number of energetic ions and a large number of energetic neutrals. The energy distribution ranges from thermal energies up to a maximum energy of the discharge. The various reaction mechanisms which contribute to the exceptionally strong adherence - formation of a graded substrate/coating interface are not fully understood, however the controlling factors are evaluated. The influence of process variables on the nucleation and growth characteristics are illustrated in terms of morphological changes which affect the mechanical and tribological properties of the coating.

Spalvins, T.↗

HCMM satellite follow-on investigation no. 25. Soil moisture and heat budget evalution in selected European zones of agricultural and environmental interest (TELLUS project)

A simple procedure to evaluate actual evaporation was derived by linearizing the surface energy balance equation, using Taylor's expansion. The original multidimensional hypersurface could be reduced to a linear relationship between evaporation and surface temperature or to a surface relationship involving evaporation, surface temperature and albedo. This procedure permits a rapid sensitivity analysis of the surface energy balance equation as well as a speedy mapping of evaporation from remotely sensed surface temperatures and albedo. Comparison with experimental data yielded promising results. The validity of evapotranspiration and soil moisture models in semiarid conditions was tested. Wheat was the crop chosen for a continuous measurement campaign made in the south of Italy. Radiometric, micrometeorologic, agronomic and soil data were collected for processing and interpretation.

Source record↗

Liquid spray cooling of a heated surface

The lowest surface temperature possible for the existance of spray evaporative cooling is determined experimentally to be a linear function of the impinging spray mass flux. A conduction-controlled analytical model of droplet evaporation gives fairly good agreement with experimental measurements at atmospheric pressure. At reduced pressures droplet evaporation rates are decreased significantly such that an optimum operating pressure exists for each desired surface heat flux. The initiation of the 'Leidenfrost state' provides the upper surface temperature bound for spray evaporative cooling.

Grissom, W. M.↗

Solar cell contacts

Two experimental contact systems were examined and compared to a baseline contact system consisting of evaporated layers of titanium, palladium, and silver and an electroplated layer of copper. The first experimental contact system consisted of evaporated layers of titanium, nickel, and copper and an electroplated layer of copper. This system performed as well as the baseline system in all respects, including its response to temperature stress tests, to a humidity test, and to an accelerated aging test. In addition, the cost of this system is estimated to be only 43 percent of the cost of the baseline system at a production level of 25 MW/year. The second experimental contact system consisted of evaporated layers of nickel and copper and an electroplated layer of copper. Cells with this system show serious degradation in a temperature stress test at 350 C for 30 minutes. Auger electron spectroscopy was used to show that the evaporated nickel layer is not an adequate barrier to copper diffusion even at temperatures as low as 250 C. This fact brings into question the long-term reliability of this contact system.

Meier, D. L.↗

A thermomechanical model for energy propagation in a solid-fluid-solid system with one boundary in relative motion

A model is developed to predict the behavior of a thin fluid film in the wake of a tool in relative motion with respect to the table. Computational procedures are developed and limitations of the model are discussed. In general the fluid-interface temperature is controlled by conduction into the table. From the numerical results four regimes are identified: convective cooling, partial evaporation of the fluid film, extended evaporation due to a limiting evaporative heat flux, and surface dryout due to total evaporation of the fluid layer. These regimes are qualitatively illustrated in terms of the parameters film thickness, viscosity, and relative velocity.

Braun, M. J.↗

Functional and performance tests of two capillary pumped loop engineering models

This paper presents the results of the functional and performance tests for two capillary pumped loop (CPL) engineering models. Both CPL systems are aluminum/ammonia transport systems which contain eight parallel evaporators and six parallel condensers in a single loop. Tests conducted include the transport limit, heat load shearing between evaporators, liquid inventory/temperature control by the reservoir, pressure priming under heat load, diode function of condensers, and isolation of a single deprimed evaporator. Consistent performance results were obtained for both systems. Transport capabilities of up to 70 kw-m with individual evaporators managing up to 1.7 kw, with a corresponding input heat flux of 15w/sq cm, were demonstrated. These tests demonstrated the ability of a CPL system to operate over a wide range of conditions and thus established the viability of these systems for high power thermal management of large spacecraft, such as the NASA Space Station.

Ku, J.↗

Chromospheric explosions

Three issues relative to chromospheric explosions were debated. (1) Resolved: The blue-shifted components of x-ray spectral lines are signatures of chromospheric evaporation. It was concluded that the plasma rising with the corona is indeed the primary source of thermal plasma observed in the corona during flares. (2) Resolved: The excess line broading of UV and X-ray lines is accounted for by a convective velocity distribution in evaporation. It is concluded that the hypothesis that convective evaporation produces the observed X-ray line widths in flares is no more than a hypothesis. It is not supported by any self-consistent physical theory. (3) Resolved: Most chromospheric heating is driven by electron beams. Although it is possible to cast doubt on many lines of evidence for electron beams in the chromosphere, a balanced view that debaters on both sides of the question might agree to is that electron beams probably heat the low corona and upper chromosphere, but their direct impact on evaporating the chromosphere is energetically unimportant when compared to conduction. This represents a major departure from the thick-target flare models that were popular before the Workshop.

Doschek, G. A.↗

Model for determining vapor equilibrium rates in the hanging drop method for protein crystal growth

An engineering analysis of the rate of evaporation of solvent in the hanging drop method of protein crystal growth is presented. Results are applied to 18 drop and well arrangements commonly encountered in the laboratory. The chemical nature of the salt, drop size and shape, drop concentration, well size, well concentration, and temperature are taken into account. The rate of evaporation increases with temperature, drop size, and the salt concentration difference between the drop and the well. The evaporation in this model possesses no unique half-life. Once the salt in the drop achieves 80 percent of its final concentration, further evaporation suffers from the law of diminishing returns.

Baird, James K.↗

Experimental and theoretical analysis of the rate of solvent equilibration in the hanging drop method of protein crystal growth

The principles of the hanging-drop method of crystal growth are discussed, and the rate of water evaporation in a water droplet (containing protein, buffer, and a precipitating agent) suspended above a well containing a double concentration of precipitating agent is investigated theoretically. It is shown that, on earth, the rate of evaporation may be determined from diffusion theory and the colligative properties of solutions. The parameters affecting the rate of evaporation include the temperature, the vapor pressure of water, the ionization constant of the salt, the volume of the drop, the contact angle between the droplet and the coverslip, the number of moles of salt in the droplet, the number of moles of water and salt in the well, the molar volumes of water and salt, the distance from the droplet to the well, and the coefficient of diffusion of water vapor through air. To test the theoretical equations, hanging-drop experiments were conducted using various reagent concentrations in 25-microliter droplets and measuring the evaporation times at 4 C and 25 C. The results showed good agreement with the theory.

Fowlis, William W.↗

Effects Of Turbulence On Ignition

Report presents theoretical study of effects of turbulence on ignition of drops of single-component liquid fuel. Closely related to article, "Turbulence and Evaporation in Clusters of Drops" (NPO-17323). Uses theoretical model for evaporation and model for ignition developed previously. Radial velocity, va, of gas at surface of sphere of influence taken as algebraic combination of rate of evaporation and speed with which radius changes. Weighting factors of algebraic combination are such that in dilute spray, all new vapor coming from drops trapped in cluster, whereas in dense spray where evaporation strong, maximum new vapor escapes to ambient.

Bellan, Josette↗

H-alpha redshifts as a diagnostic of solar flare heating

The dynamics of chomospheric condensations formed during chromospheric evaporation are studied using coordinated X-ray and H-alpha observations of five solar flares. It is shown that the peak downflow velocity of condensations predicted by simple hydrodynamic compression of the chromosphere is in good agreement with empirical downflow velocities implied by impulsive phase H-alpha red wing Doppler shifts. It is found that the H-alpha wing redshift provides a diagnostic of the pressure excess in the evaporating region and the coronal energy flux driving chromospheric evaporation. Because preflare coronal pressures derived for each of the flares are high, it is suggested that the chromosphere succeeds in radiating excess flare heat energy without undergoing explosive chromospheric evaporation.

Zarro, Dominic M.↗

Transient characteristics of a grooved water heat pipe with variable heat load

The transient characteristics of a grooved water heat pipe were studied by using variable heat load. First, the effects of the property variations of the working fluid with temperature were investigated by operating the water heat pipe at several different temperatures. The experimental results show that, even for the same heat input profile and heat pipe configuration, the heat pipe transports more heat at higher temperature within the tested temperature range. Adequate liquid return to the evaporator due to decreasing viscosity of the working fluid permits continuous vaporization of water without dry-out. Second, rewetting of the evaporator was studied after the evaporator had experienced dry-out. To rewet the evaporator, the elevation of the condenser end was the most effective way. Without elevating the condenser end, rewetting is not straight-forward even with power turned off unless the heat pipe is kept at isothermal condition for sufficiently long time.

Jang, Jong Hoon↗

Sources of Sahel precipitation for simulated drought and rainy seasons

The sources of sub-Saharan precipitation are studied using diagnostic procedures integrated into the code of the GISS climate model. Water vapor evaporating from defined source regions is 'tagged', allowing the determination of the relative contributions of each evaporative source to the simulated July rainfall in the Sahel. Two June-July simulations are studied to compare the moisture sources, moisture convergence patterns and the spatial variations of precipitation for rainy and drought conditions. Results for this case study indicate that patterns of moisture convergence and divergence over northern Africa had a stronger influence on model rainfall over the sub-Sahara than did evaporation rates over the adjacent oceans or moisture advection from ocean to continent. While local continental evaporation contributed significant amounts of water to Sahelian precipitation in the'rainy' simulation, moisture from the Indian Ocean did not precipitate over the Sahel in either case.

Druyan, Leonard M.↗

Numerical analysis of natural convection in liquid droplets by phase change

A numerical analysis is performed on thermocapillary buoyancy convection induced by phase change in a liquid droplet. A finite-difference code is developed using an alternating-direction implicit (ADI) scheme. The intercoupling relation between thermocapillary force, buoyancy force, fluid property, heat transfer, and phase change, along with their effects on the induced flow patterns, are disclosed. The flow is classified into three types: thermocapillary, buoyancy, and combined convection. Among the three mechanisms, the combined convection simulates the experimental observations quite well, and the basic mechanism of the observed convection inside evaporating sessile drops is thus identified. It is disclosed that evaporation initiates unstable convection, while condensation always brings about a stable density distribution which eventually damps out all fluid disturbances. Another numerical model is presented to study the effect of boundary recession due to evaporation, and the 'peeling-off' effect (the removal of the surface layer of fluid by evaporation) is shown to be relevant.

Duh, J. C.↗

Transient analysis of a capillary pumped loop heat pipe

A bench-top Capillary Pumped Loop (CPL) test system has been developed and tested to investigate the transient mode operation of this system by applying a step power input to the evaporators. Tests were conducted at several power input and evaporator inlet subcooling combinations. In addition, a lumped-heat-capacity model of the CPL test system has been presented which is used for predicting qualitatively the transient operation characteristics. Good agreement has been obtained between the predicted and the measured temperature variations. A simple evaporator inlet subcooler model has also been developed to study effects of inlet subcooling on the steady-state evaporator wall temperature. Results were compared with the test data collected.

Kiper, A. M.↗

Understanding land surface evapotranspiration with satellite multispectral measurements

Quantitative use of remote multispectral measurements to study and map land surface evapotranspiration has been a challenging issue for the past 20 years. Past work is reviewed against process physics. A simple two-layer combination-type model is used which is applicable to both vegetation and bare soil. The theoretic analysis is done to show which land surface properties are implicitly defined by such evaporation models and to assess whether they are measurable as a matter of principle. Conceptual implications of the spatial correlation of land surface properties, as observed by means of remote multispectral measurements, are illustrated with results of work done in arid zones. A normalization of spatial variability of land surface evaporation is proposed by defining a location-dependent potential evaporation and surface temperature range. Examples of the application of remote based estimates of evaporation to hydrological modeling studies in Egypt and Argentina are presented.

Menenti, M.↗