Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrode Engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Hybrid Power Management (HPM)

The NASA Glenn Research Center s Avionics, Power and Communications Branch of the Engineering and Systems Division initiated the Hybrid Power Management (HPM) Program for the GRC Technology Transfer and Partnership Office. HPM is the innovative integration of diverse, state-of-the-art power devices in an optimal configuration for space and terrestrial applications. The appropriate application and control of the various power devices significantly improves overall system performance and efficiency. The advanced power devices include ultracapacitors and fuel cells. HPM has extremely wide potential. Applications include power generation, transportation systems, biotechnology systems, and space power systems. HPM has the potential to significantly alleviate global energy concerns, improve the environment, and stimulate the economy. One of the unique power devices being utilized by HPM for energy storage is the ultracapacitor. An ultracapacitor is an electrochemical energy storage device, which has extremely high volumetric capacitance energy due to high surface area electrodes, and very small electrode separation. Ultracapacitors are a reliable, long life, maintenance free, energy storage system. This flexible operating system can be applied to all power systems to significantly improve system efficiency, reliability, and performance. There are many existing and conceptual applications of HPM.

Eichenberg, Dennis J.↗

Microelectromechanical (MEMS) manipulators for control of nanoparticle coupling interactions

A nanopositioning system for producing a coupling interaction between a first nanoparticle and a second nanoparticle. A first MEMS positioning assembly includes an electro-static comb drive actuator configured to selectively displace a first nanoparticle in a first dimension and an electrode configured to selectively displace the first nanoparticle in a second dimensions. Accordingly, the first nanoparticle may be selectively positioned in two dimensions to modulate the distance between the first nanoparticle and a second nanoparticle that may be coupled to a second MEMS positioning assembly. Modulating the distance between the first and second nanoparticles obtains a coupling interaction between the nanoparticles that alters at least one material property of the nanoparticles applicable to a variety of sensing and control applications.

42 ENGINEERING↗

Bismuth Subcarbonate Decorated Reduced Graphene Oxide Nanocomposite for the Sensitive Stripping Voltammetry Analysis of Pb(II) and Cd(II) in Water

In this paper, bismuth subcarbonate (BiO)2CO3-reduced graphene oxide nanocomposite incorporated in Nafion matrix ((BiO)2CO3-rGO-Nafion) was synthesized and further applied, for the first time, in the sensitive detection of Pb(II) and Cd(II) by square-wave anodic stripping voltammetry (SWASV). The as-synthesized nanocomposites were characterized by energy-dispersive spectroscopy (EDS), Raman spectroscopy, scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). (BiO)2CO3 composite plays a key role in the improvement of the detection sensitivity, which can form multicomponent alloy with cadmium and lead. Additionally, the unique structure of rGO can enlarge the surface area and provide abundant active sites. Moreover, Nafion incorporation in the nanocomposite can effectively increase the adhesion and mechanical strength of the film, and further improve the preconcetration ability due to the cation-exchange capacity of its abundant sulfonate groups. As expected, the (BiO)2CO3-rGO/Nafion nanocomposite-modified glassy carbon electrode ((BiO)2CO3-rGO-Nafion/GCE) achieved low detection limits of 0.24 μg/L for Pb(II) and 0.16 μg/L for Cd(II), in the linear range of 1.0–60 μg/L, and showed some excellent performance, such as high stability, good selectivity, and sensitivity. Finally, synthetic water samples were prepared and further used to verify the practicability of the (BiO)2CO3-rGO-Nafion/GCE with satisfactory results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Membraneless seawater desalination

Disclosed are microfluidic devices and systems for the desalination of water. The devices and systems can include an electrode configured to generate an electric field gradient in proximity to an intersection formed by the divergence of two microfluidic channels from an inlet channel. Under an applied bias and in the presence of a pressure driven flow of saltwater, the electric field gradient can preferentially direct ions in saltwater into one of the diverging microfluidic channels, while desalted water flows into second diverging channel. Also provided are methods of using the devices and systems described herein to decrease the salinity of water.

42 ENGINEERING↗

Nano Sensors for Gas Detection in Space and Ground Support Applications

Personnel living in a space environment as well as technicians and engineers preparing spacecraft for launch can potentially be exposed to small amounts of hazardous gases. It is therefore important to be able to detect, identify and quantify the presence of a gas especially when its presence could lead to a fatal situation. The use of small and sensitive sensors can allow for the placement of these devices over a large area, thus allowing for a more precise and timely determination of a gas leak. ASRC Aerospace and its research partners are developing nano sensors for detection of various gases, including but not limited to: H2, NH3, N2O4, hydrazine and others. Initial laboratory testing has demonstrated the capability to detect the gases in concentrations lower than parts per million. Testing and development is continuing to improve the response and recovery times, to increase the sensitivity of the devices. Different coatings and electrodes are currently being evaluated to determine the optimum configuration of a variety of gases. The small footprint of the Nano sensors allows for several devices, each responsive in a different way to different gases, to be placed into a single substrate. Multiple devices embedded into a single substrate results in increased reliability and in a decrease for periodic calibrations. The use of different coatings will result in a small electronic nose capable of distinguishing between different gases. A multi-channel signal conditioner amplifier built on a small multi chip module is used to process the output of the sensors and to deliver a signal that can be remotely monitored. All the data is digitized and transmitted over the same cable pair used to power the amplifier. Multiple outputs can be connected to a single cable pair in order to minimize the added weight and expense associated with cabling in a spacecraft. The sensors will be run through a qualification process to evaluate their suitability for space applications we are expecting to have fully functional sensors available for initial field deployment and testing by the end of the year 2006.

Medelius, Pedro J.↗

An engineered lactate oxidase based electrochemical sensor for continuous detection of biomarker lactic acid in human sweat and serum

Lactate levels in humans reveal intensity and duration of exertion and provide a critical readout for the severity of life-threatening illnesses such as pediatric sepsis. Using the lactate oxidase enzyme (Lox) from Aerococcus viridians, we demonstrated its functionality for lactate electrochemical sensing in physiological fluids in a lab setting. The structure and dynamics of LOx were validated by crystallography, X-ray scattering, and hydroxyl radical protein footprinting. This provided a validated protein template for understanding and designing an enzyme-based electrochemical sensing elements. Using this template, LOx enzyme variants were generated and compared. Comparison of the variants demonstrates that one exhibits effective lactate sensing at significantly reduced operating voltages. Additionally, we demonstrate that the four hexahistidine-tags on each enzyme tetramer are sufficient for immobilization to create a durable, functional sensor, with no need for a covalent attachment, enabling self-immobilization and eliminating the need for additional immobilization steps. The functionality of the LOx enzyme variants was verified at physiological lactate concentrations in both human serum (0–4 mM) and artificial sweat (0–100 mM) using 3-electrode setups for analysis of the three variants in parallel. Accuracy of measurement in both artificial sweat and human serum were high. Employing a microfluidic flow cell, we successfully monitored varying lactate levels in physiological fluids continuously over a 2h period. Overall, this optimized LOx enzyme, which self-immobilizes onto gold sensing electrodes, facilitates efficient and reliable lactate detection and continuous monitoring at reduced operating voltages suitable for further development towards commercial use.

60 APPLIED LIFE SCIENCES↗

Thermodynamic properties of Gd-Bi alloys determined by emf measurements in LiCl-KCl-GdCl 3 electrolyte

Thermodynamic properties of binary Gd-Bi alloys (mole fraction, x Gd = 0.02–0.35) were determined using electromotive force (emf) measurements in molten LiCl-KCl-GdCl 3 electrolyte in complement with structural, microstructural, and thermal characterization. X-ray diffractometry (XRD) and scanning electron microscopy (SEM) identified the phase constituents of Gd-Bi alloys (x Gd = 0.02–0.35) as Bi matrix and GdBi compound. According to differential scanning calorimetry (DSC) measurements up to 1250 K, a eutectic transition [L = Bi + GdBi] was observed at 543 K but the reported peritectic transition [L + GdBi = GdBi 2 ] was not detected, suggesting the absence of the GdBi 2 compound. Based on structural, microstructural, and thermal characterization of Gd-Bi alloys (x Gd = 0.02–0.35), the GdBi 2 compound was not detected, and its thermodynamic stability is questionable. The emf of Gd-Bi alloy (x Gd = 0.16) at 700–1048 K relative to Gd(s) was measured by electrodepositing pure Gd metal at 25 K increments. Further, the emf values of Gd-Bi alloys were determined via coulometric titration of Gd into liquid Bi using a two-phase [L + GdBi] alloy as a reference electrode at 773–973 K. The solubility of Gd in liquid Bi was also estimated to be 0.50 mol% (773 K), 0.99 mol% (873 K), and 2.21 mol% (973 K) and the excess partial molar Gibbs energy (Δ$\mathrm{\bar{G}^{ex}_{Gd}}$) of liquid Gd-Bi alloys was as low as 65 kJ mol –1 , indicating strong chemical interactions between Gd and Bi.

36 MATERIALS SCIENCE↗

Toward Polarization-Switched Molecular Pumps

Pumping of fluids is universally performed by using mechanical or thermal compressors. We demonstrate for the first time a new solid-state molecular pumping mechanism induced by switching the adsorption affinity for a gas through polarization of a chromophore under an applied electric field. Mass spectrometry was used to trace refrigerant gas (difluoromethane) uptake on a chromophore-coated capacitor under applied voltage and subsequent desorption when the voltage and electrode polarization was removed showing an exchange capacity of 0.11 mol of refrigerant per liter of chromophore. Calorimetry confirmed a reversible enthalpy change of 9 Kcal/mol in the polarization-induced sorption-desorption process. Here, the present work establishes the principle and feasibility of non-mechanical molecular pumping, which can be exploited for refrigeration, catalysis, gas separation, among many other potential applications.

42 ENGINEERING↗

Thickness-independent scalable high-performance Li-S batteries with high areal sulfur loading via electron-enriched carbon framework

Abstract Increasing the energy density of lithium-sulfur batteries necessitates the maximization of their areal capacity, calling for thick electrodes with high sulfur loading and content. However, traditional thick electrodes often lead to sluggish ion transfer kinetics as well as decreased electronic conductivity and mechanical stability, leading to their thickness-dependent electrochemical performance. Here, free-standing and low-tortuosity N, O co-doped wood-like carbon frameworks decorated with carbon nanotubes forest (WLC-CNTs) are synthesized and used as host for enabling scalable high-performance Li-sulfur batteries. EIS-symmetric cell examinations demonstrate that the ionic resistance and charge-transfer resistance per unit electro-active surface area of S@WLC-CNTs do not change with the variation of thickness, allowing the thickness-independent electrochemical performance of Li-S batteries. With a thickness of up to 1200 µm and sulfur loading of 52.4 mg cm −2 , the electrode displays a capacity of 692 mAh g −1 after 100 cycles at 0.1 C with a low E/S ratio of 6. Moreover, the WLC-CNTs framework can also be used as a host for lithium to suppress dendrite growth. With these specific lithiophilic and sulfiphilic features, Li-S full cells were assembled and exhibited long cycling stability.

36 MATERIALS SCIENCE↗

Microelectromechanical (MEMS) manipulators for control of nanoparticle coupling interactions

A nanopositioning system for producing a coupling interaction between a first nanoparticle and a second nanoparticle. A first MEMS positioning assembly includes an electrostatic comb drive actuator configured to selectively displace a first nanoparticle in a first dimension and an electrode configured to selectively displace the first nanoparticle in a second dimensions. Accordingly, the first nanoparticle may be selectively positioned in two dimensions to modulate the distance between the first nanoparticle and a second nanoparticle that may be coupled to a second MEMS positioning assembly. Modulating the distance between the first and second nanoparticles obtains a coupling interaction between the nanoparticles that alters at least one material property of the nanoparticles applicable to a variety of sensing and control applications.

36 MATERIALS SCIENCE↗

Atomically Dispersed Ni‐N‐C Catalysts for Electrochemical CO 2 Reduction

Abstract The atomic dispersion of nickel in Ni‐N‐C catalysts is key for the selective generation of carbon monoxide through the electrochemical carbon dioxide reduction reaction (CO 2 RR). Herein, the study reports a highly selective, atomically dispersed Ni 1.0% ‐N‐C catalyst with reduced Ni loading compared to previous reports. Extensive materials characterization fails to detect Ni crystalline phases, reveals the highest concentration of atomically dispersed Ni metal, and confirms the presence of the proposed Ni‐N x active site at this reduced loading. The catalyst shows excellent activity and selectivity toward CO generation, with a faradaic efficiency for CO generation (FE CO ) of 97% and partial current density for CO (j co ) of ‐9.0 mA cm −2 at ‐0.9 V in an electrochemical H‐type cell. CO 2 RR activity and selectivity are also studied by rotating disk electrode (RDE) measurements where transport limitations can be suppressed. It is expected that the utility of these Ni‐N‐C catalysts will lie with tandem CO 2 RR reaction schemes to multi‐carbon (C 2+ ) products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiscale operando X-ray investigations provide insights into electro-chemo-mechanical behavior of lithium intercalation cathodes

The electrochemical performance and cycle life of lithium-ion batteries (LIBs) depend on the electrochemical, chemical, and mechanical behavior of electrodes and electrolytes. Despite extensive studies conducted previously, challenges exist to decouple these behaviors, capture the evolution of electro-chemo-mechanical behavior in realistic conditions, and correlate atomic-scale stress evolution to micro-scale bulk mechanical degradation. Here, we report multiscale operando techniques to investigate polydisperse battery electrodes by integrating volume-averaged quantitative synchrotron X-ray scattering with high-resolution transmission X-ray microscopy (TXM). The former provides us information spanning a wide spatial range, from Angstrom-level atomic structures to micrometer-level particle scales, while the latter provides time-resolved 2D images of the particles during cycling. The complementarity of the two operando techniques is demonstrated by an over-lithiation test of LiCoO 2 electrodes, where particles crack and eventually pulverize. Additionally, the techniques are applied to study LiCoO 2 cycling stability from 3.0 V to 4.5 V. Operando X-ray scattering result shows nanometer-scale features keep forming in LiCoO 2 electrodes during cycling, resulting in an increased projected area observed by the TXM experiment. The formation of such features is inhibited by a polymer coating on the electrode, leading to vastly improved cycling stability. The polymer coating alleviates LiCoO 2 surface deterioration, reduces side product generation, and inhibits LiCoO 2 particles volume expansion during the cycling test. These operando multimodal X-ray techniques presented herein thus offer a novel, multiscale diagnostic modality for studying existing and emerging battery materials, aiding the development of next-generation LIBs.

25 ENERGY STORAGE↗

Stress- and interface-compatible red phosphorus anode for high-energy and durable sodium-ion batteries

Sodium-ion battery is a promising candidate for energy storage application, but the absence of high-capacity and low-cost anode materials significantly limit their practical specific energy and cost. Red phosphorus (RP) possesses a high theoretical specific capacity but suffers from large volume change, low electronic conductivity and unstable solid-electrolyte interphase (SEI). Herein, a hierarchical micro/nanostructured antimony-doped RP/carbon anode was developed, which demonstrate extraordinary electrochemical performance with high initial Coulombic efficiency of ~90%, high areal (~1.7 mAh cm-2) capacity together with good cycle stability and rate capability. Combined experimental and computational studies consistently revealed that such a unique structural design can dramatically accommodate the mechanical stress and moreover effectively restrain the undesired decomposition of electrolyte solvents regardless of electrolytes formulation, resulting in superior structural integrity and thin/robust SEI formation during cycling. The present finding has offered an alternative strategy for stress management and interface engineering on high-capacity alloying-based anode materials.

Liu, Xiang↗

Time‐Dependent Cation Selectivity of Titanium Carbide MXene in Aqueous Solution

Abstract Electrochemical ion separation is a promising technology to recover valuable ionic species from water. Pseudocapacitive materials, especially 2D materials, are up‐and‐coming electrodes for electrochemical ion separation. For implementation, it is essential to understand the interplay of the intrinsic preference of a specific ion (by charge/size), kinetic ion preference (by mobility), and crystal structure changes. Ti 3 C 2 T z MXene is chosen here to investigate its selective behavior toward alkali and alkaline earth cations. Utilizing an online inductively coupled plasma system, it is found that Ti 3 C 2 T z shows a time‐dependent selectivity feature. In the early stage of charging (up to about 50 min), K + is preferred, while ultimately Ca 2+ and Mg 2+ uptake dominate; this unique phenomenon is related to dehydration energy barriers and the ion exchange effect between divalent and monovalent cations. Given the wide variety of MXenes, this work opens the door to a new avenue where selective ion‐separation with MXene can be further engineered and optimized.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Glove-based sensors for multimodal monitoring of natural sweat

Sweat sensors targeting exercise or chemically induced sweat have shown promise for noninvasive health monitoring. Natural thermoregulatory sweat is an attractive alternative as it can be accessed during routine and sedentary activity without impeding user lifestyles and potentially preserves correlations between sweat and blood biomarkers. We present simple glove-based sensors to accumulate natural sweat with minimal evaporation, capitalizing on high sweat gland densities to collect hundreds of microliters in just 30 min without active sweat stimulation. Sensing electrodes are patterned on nitrile gloves and finger cots for in situ detection of diverse biomarkers, including electrolytes and xenobiotics, and multiple gloves or cots are worn in sequence to track overarching analyte dynamics. Direct integration of sensors into gloves represents a simple and low-overhead scheme for natural sweat analysis, enabling sweat-based physiological monitoring to become practical and routine without requiring highly complex or miniaturized components for analyte collection and signal transduction.

42 ENGINEERING↗

Redox Potential Measurements of Cr(II)/Cr Ni(II)/Ni and Mg(II)/Mg in Molten MgCl 2 –KCl–NaCl Mixture

The redox potential of Ni(II)/Ni, Cr(II)/Cr, and Mg(II)/Mg in MgCl 2 –KCl–NaCl (Magnak chloride) were studied utilizing chronopotentiometry (CP) method in a three-electrode electrochemical cell. Four different CrCl 2 concentrations from 873 K to 1073 K, three NiCl 2 concentrations from 773 K to 1073 K, and two MgCl 2 concentrations from 823 K to 1073 K have been measured. The activity coefficients were calculated referring to a supercooled potential accordingly. The empirical equation of formal potential will be of great significance for the fundamental thermodynamic prediction in high-temperature Magnak chloride systems where corrosion product impurities are present.

14 SOLAR ENERGY↗

Multi-modal characterization of nitrate reduction nano-catalysts with periodic strain distribution

Strain engineering serves as a pivotal strategy to optimize catalytic activity in electrocatalysis. However, the catalyst sizes under industrial conditions are usually large and even beyond nanometer regime. The critical methodological limitations on strain imaging of such catalysts with both large field of view and high spatial resolution obscure the mechanistic understanding of strain-performance correlations. Here, we present an optimized four-dimensional scanning transmission electron microscopy (4D-STEM) method to acquire strain mapping of both bulk and surface across particles up to 500 nm with 0.6 nm spatial resolution and 0.55% precision. We observe the ripple-like periodic strain coupled with elemental fluctuations inside a perovskite-type hydroxide CuCoSn(OH) 6 and find it correlated to electrocatalytic nitrate reduction (NO 3 – RR) absorption energy to achieve the 92.6% Faradaic efficiency and long-term test over 1000 h at membrane electrode assembly (MEA) for ammonia electrosynthesis. This universal framework design offers a practical method that not only develops an advanced measurement combining multi-modal characterization techniques but also reveals the intrinsic structure-property constitutive law of industry-level catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗