Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Significance and complications of drilling fluid rheology in geothermal drilling: A review

The harsh downhole conditions of high pressure and high temperature (HPHT) encountered in geothermal wells make the drilling operation challenging. Drilling in such environments requires a special drilling mud formulation with high thermal stability and good rheological properties to fulfill the drilling fluid functions. Therefore, great efforts should be put into selecting the suitable drilling fluid, optimize and monitor the drilling fluid properties throughout drilling operations, and predicting its performance under downhole conditions. Rheological properties significantly impact many drilling parameters such as hole cleaning, fluid and wellbore stability, wellbore hydraulics, torque and drag, and other drilling issues. This paper discusses water-based drilling fluids' flow behavior under HPHT conditions and highlights the significance of fluid rheology in geothermal drilling. The common challenges and complications related to fluid rheology encountered in geothermal drilling are addressed in this paper, such as hole cleaning, wellbore hydraulics, and drilling fluid stability. This article also reviews the recent advances in drilling mud systems, rheology enhancement, and rheological properties measurements at surface and subsurface conditions. Furthermore, the rheology models of drilling fluid at elevated temperatures are reviewed to fully understand their flow behavior and establish a method for drilling engineers to optimize fluid formulations for geothermal drilling.

58 GEOSCIENCES↗

Assessing mechanical response of CO 2 storage into a depleted carbonate reef using a site-scale geomechanical model calibrated with field tests and InSAR monitoring data

Geomechanical risks of injection have raised concerns regarding secure CO 2 storage. In this work, a combined monitoring and modeling approach is used to assess the stress changes and surface uplift associated with CO 2 injection into a depleted carbonate reef of the Michigan basin. A site-scale geomechanical model is built by assigning mechanical properties of formations using well-log and experimental data. Gravity load is applied to the model to estimate the vertical component of stress as well as different lateral boundary displacement scenarios to estimate horizontal stresses. We used a poroelastic pressure-dependent model (instead of a linear elastic mechanical earth model) to calibrate initial stresses using hydraulic fracture test data measured at depleted reservoir status. Multi-phase fluid flow-geomechanical simulations are performed to estimate the poroelastic response during (1) primary depletion (2) field-scale CO 2 injection phase (3) a hypothetical forecast scenario in which well bottom hole pressure (BHP) reach 45000 KPa. The predicted surface uplift is less than 1 mm at the end of the field-scale CO 2 injection phase which is in good agreement with Interferometric Synthetic Aperture Radar (InSAR) uplift measurement. Although the InSAR data shows an insignificant uplift, hydromechanical modeling of injection shows that CO 2 injection still causes reservoir deformation emphasizing the role of carbonate overburden and reservoir formation mechanical properties and limited size of reef on diminishing the surface deformation. Modeling indicates poroelastic response of caprock matters to estimate uplift. The lower permeability of the top two layers provides additional barrier to large uplift. Also, history of subsidence due to production should be accounted to predict uplift due to a follow up injection correctly. This report shows the significance of combining a calibrated geomechanical model with field measured stresses and monitoring data to be used as a tool to ensure the safety of CO 2 storage.

42 ENGINEERING↗

Reduction of hexavalent chromium by fasted and fed human gastric fluid. I. Chemical reduction and mitigation of mutagenicity

Evaluation of the reducing capacity of human gastric fluid from healthy individuals, under fasted and fed conditions, is critical for assessing the cancer hazard posed by ingested hexavalent chromium [Cr(VI)] and for developing quantitative physiologically-based pharmacokinetic models used in risk assessment. In the present study, the patterns of Cr(VI) reduction were evaluated in 16 paired pre- and post-meal gastric fluid samples collected from 8 healthy volunteers. Human gastric fluid was effective both in reducing Cr(VI), as measured by using the s-diphenylcarbazide colorimetric method, and in attenuating mutagenicity in the Ames test. The mean (± SE) Cr(VI)-reducing ability of post-meal samples (20.4 ± 2.6 μg Cr(VI)/mL gastric fluid) was significantly higher than that of pre-meal samples (10.2 ± 2.3 μg Cr(VI)/mL gastric fluid). When using the mutagenicity assay, the decrease of mutagenicity produced by pre-meal and post-meal samples corresponded to reduction of 13.3 ± 1.9 and 25.6 ± 2.8 μg Cr(VI)/mL gastric fluid, respectively. These data are comparable to parallel results conducted by using speciated isotope dilution mass spectrometry. Cr(VI) reduction was rapid, with > 70% of total reduction occurring within 1 min and 98% of reduction is achieved within 30 min with post-meal gastric fluid at pH 2.0. pH dependence was observed with decreasing Cr(VI) reducing capacity at higher pH. Attenuation of the mutagenic response is consistent with the lack of DNA damage observed in the gastrointestinal tract of rodents following administration of ≤ 180 ppm Cr(VI) for up to 90 days in drinking water. Quantifying Cr(VI) reduction kinetics in the human gastrointestinal tract is necessary for assessing the potential hazards posed by Cr(VI) in drinking water. - Highlights: • Cr(VI) reduction capacity was greater in post-meal than paired pre-meal samples. • Cr(VI) reduction was rapid, pH dependent, and due to heat stable components. • Gastric fluid attenuates the mutagenicity of Cr(VI) and reduces risk of GI cancer. • The results are useful to quantitatively evaluate the fate of ingested Cr(VI).

60 APPLIED LIFE SCIENCES↗

Pressure drop and temperature rise in He II flow in round tubes, Venturi flowmeters and valves

Pressure drops in highly turbulent He II flow were measured in round tubes, valves, and Venturi flowmeters. Results are in good agreement with single-phase flow correlations for classical fluids. The temperature rise in flow in a round tube was measured, and found to agree well with predictions for isenthalpic expansion. Cavitation was observed in the venturis under conditions of low back pressure and high flow rate. Metastable superheating of the helium at the venturi throat was observed before the helium made a transition to saturation pressure.

Walstrom, P. L.↗

Turbulent Mixing of Primary and Secondary Flow Streams in a Rocket-Based Combined Cycle Engine

This viewgraph presentation gives an overview of the turbulent mixing of primary and secondary flow streams in a rocket-based combined cycle (RBCC) engine. A significant RBCC ejector mode database has been generated, detailing single and twin thruster configurations and global and local measurements. On-going analysis and correlation efforts include Marshall Space Flight Center computational fluid dynamics modeling and turbulent shear layer analysis. Potential follow-on activities include detailed measurements of air flow static pressure and velocity profiles, investigations into other thruster spacing configurations, performing a fundamental shear layer mixing study, and demonstrating single-shot Raman measurements.

Cramer, J. M.↗

Dispersion Validation for Flow Involving a Large Structure Revisited: 45 Degree Rotation

The atmospheric dispersion of contaminants in the wake of a large urban structure is a challenging fluid mechanics problem of interest to the scientific and engineering communities. Magnetic Resonance Velocimetry (MRV) and Magnetic Resonance Concentration (MRC) are relatively new techniques that leverage diagnostic equipment used primarily by the medical field to make 3D engineering measurements of flow and contaminant dispersal. SIERRA/Fuego, a computational fluid dynamics (CFD) code at Sandia National Labs is employed to make detailed comparisons to the dataset to evaluate the quantitative and qualitative accuracy of the model. This work is the second in a series of scenarios. In the prior work, a single large building in an array of similar buildings was considered with the wind perpendicular to a building face. In this work, the geometry is rotated by 45 degrees and improved studies are performed for simulation credibility. The comparison exercise shows conditionally good comparisons between the model and experiment. Model uncertainties are assessed through parametric variations. Various methods of quantifying the accuracy between experiments and data are examined Three-dimensional analysis of accuracy is performed. The effort helped identify deficiencies in the techniques used to make these comparisons, and further methods development therefore becomes one of the main recommendations for follow-on work.

42 ENGINEERING↗

Electric Field Measurements to Investigate Sheath Formation in a Nanosecond Pulsed Discharge

The objective of the research was to study the temporally and spatially resolved dynamics of sheath formation in a nanosecond pulsed plasma generated in a parallel plate electrode geometry at near atmospheric pressures. We have performed LIF dip measurements at the Sandia Low-Temperature Plasma Research Facility showing the capability to measure electric fields in near atmospheric pressure plasmas although with insufficient spatial resolution near the electrodes. Stark polarization spectroscopy implemented at the University of Minnesota was shown to be able to probe the formation of the sheaths in nanosecond pulsed plasmas. Within 30 ns, a reduction of the sheath thickness to about 250 μm is observed, coinciding with a gradual increase of the discharge current and proportional increase in electric field at the cathode. The electric field evolution as obtained by the fluid model is in excellent agreement with the measurements and shows that an enhanced ionization near the cathode is causing the space charge formation responsible for the increase in electric field. High resolution Stark polarization spectroscopy showed sheaths with dimensions of the order of 50 μm underlining the need of micrometer spatial resolution for sheath characterization in near atmospheric pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using 3D Measurements from MRI to Improve VVUQ

Magnetic resonance velocimetry (MRV) is a diagnostic that can measure 3D, three-component turbulent velocity fields in arbitrarily complex flow configurations. The approach uses magnetic resonance imaging (MRI), which is a system commonly available in radiology departments or medical research centers. MRV acquires signal from hydrogen protons in water channel flows. Despite the obvious utility of the measurements for investigating a variety of flows, comparisons with computational fluid dynamic (CFD) simulations largely retain traditional metrics, comparing velocity profiles and planes at discrete regions within the flow rather than using the 3D nature of the measured field. In this effort, MRV was conducted in a simple water channel with six spanwise-centered periodic obstacles roughly shaped as cubes. At a fully turbulent Reynolds number of 15,000, the channel includes two flows: a main streamwise flow and, in the wake of the second obstacle, an injected flow oriented perpendicular to the streamwise flow. The flow geometry includes partial obstacles on the side walls and is inherently 3D because of the interaction of the two streams and the wake features, making the flow challenging to completely measure with traditional optical techniques. Aside from line profiles and planar comparisons, two 3D metrics are used to compare the data with a steady Reynolds-averaged Navier–Stokes (RANS) simulation result. A brief discussion about the comparison is provided, including comments about uncertainty.

Benson, Mike [ORNL] (ORCID:000000023210116X)↗

The Dynamics of Miscible Interfaces: A Space Flight Experiment

This report presents experiments of a less viscous liquid displaced by a more viscous, miscible liquid in a vertical tube of small diameter. The liquids used are silicone oils of various viscosities. The more viscous fluid has a higher density than the less viscous fluid. The experiments showed that the interface between the liquids can be unstable and exhibits an asymmetric, sinuous shape for downward displacement. The Reynolds number is negligibly small in these experiments and the Peclet number for mass transfer is O(50)-0(l0(exp 5)). The influence of gravity is characterized by the dimensionless parameter F=g(Delta)(rho)d(sup 2)/(mu)U where g is the acceleration due to gravity, Delta(rho) is the density difference between the fluids, d is the tube diameter, mu is the viscosity of the more viscous fluid, and U is the displacement speed. Visualization and PIV measurement of the unstable linger are reported. Experiments were also conducted to study immiscible displacements in tubes in order to compare with previously obtained results for miscible fluids.

Maxworthy, Tony↗

Shock Location Dominated Transonic Flight Loads on the Active Aeroelastic Wing

During several Active Aeroelastic Wing research flights, the shadow of the over-wing shock could be observed because of natural lighting conditions. As the plane accelerated, the shock location moved aft, and as the shadow passed the aileron and trailing-edge flap hinge lines, their associated hinge moments were substantially affected. The observation of the dominant effect of shock location on aft control surface hinge moments led to this investigation. This report investigates the effect of over-wing shock location on wing loads through flight-measured data and analytical predictions. Wing-root and wing-fold bending moment and torque and leading- and trailing-edge hinge moments have been measured in flight using calibrated strain gages. These same loads have been predicted using a computational fluid dynamics code called the Euler Navier-Stokes Three Dimensional Aeroelastic Code. The computational fluid dynamics study was based on the elastically deformed shape estimated by a twist model, which in turn was derived from in-flight-measured wing deflections provided by a flight deflection measurement system. During level transonic flight, the shock location dominated the wing trailing-edge control surface hinge moments. The computational fluid dynamics analysis based on the shape provided by the flight deflection measurement system produced very similar results and substantially correlated with the measured loads data.

Lokos, William A.↗

CFD Simulations of the IHF Arc-Jet Flow: Compression-Pad/Separation Bolt Wedge Tests

This paper reports computational analyses in support of two wedge tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using two different wedge models, each placed in a free jet downstream of a corresponding different conical nozzle in the Ames 60-MW Interaction Heating Facility. Panel test articles included a metallic separation bolt imbedded in the compression-pad and heat shield materials, resulting in a circular protuberance over a flat plate. As part of the test calibration runs, surface pressure and heat flux measurements on water-cooled calibration plates integrated with the wedge models were also obtained. Surface heating distributions on the test articles as well as arc-jet test environment parameters for each test configuration are obtained through computational fluid dynamics simulations, consistent with the facility and calibration measurements. The present analysis comprises simulations of the non-equilibrium flow field in the facility nozzle, test box, and flow field over test articles, and comparisons with the measured calibration data.

TPS↗

CFD Simulations of the IHF Arc-Jet Flow: Compression-Pad/Separation Bolt Wedge Tests

This paper reports computational analyses in support of two wedge tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using two different wedge models, each placed in a free jet downstream of a corresponding different conical nozzle in the Ames 60-MW Interaction Heating Facility. Each panel test article included a metallic separation bolt imbedded in Orion compression-pad and heatshield materials, resulting in a circular protuberance over a flat plate. The protuberances produce complex model flowfields, containing shock-shock and shock-boundary layer interactions, and multiple augmented heating regions on the test plate. As part of the test calibration runs, surface pressure and heat flux measurements on water-cooled calibration plates integrated with the wedge models were also obtained. Surface heating distributions on the test articles as well as arc-jet test environment parameters for each test configuration are obtained through computational fluid dynamics simulations, consistent with the facility and calibration measurements. The present analysis comprises simulations of the nonequilibrium flowfield in the facility nozzle, test box, and flowfield over test articles, and comparisons with the measured calibration data.

CFD↗

CFD Simulations of the IHF Arc-Jet Flow: Compression-Pad Separation Bolt Wedge Tests

This paper reports computational analyses in support of two wedge tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using two different wedge models, each placed in a free jet downstream of a corresponding different conical nozzle in the Ames 60-MW Interaction Heating Facility. Each panel test article included a metallic separation bolt imbedded in Orion compression-pad and heatshield materials, resulting in a circular protuberance over a flat plate. The protuberances produce complex model flowfields, containing shock-shock and shock-boundary layer interactions, and multiple augmented heating regions on the test plate. As part of the test calibration runs, surface pressure and heat flux measurements on water-cooled calibration plates integrated with the wedge models were also obtained. Surface heating distributions on the test articles as well as arc-jet test environment parameters for each test configuration are obtained through computational fluid dynamics simulations, consistent with the facility and calibration measurements. The present analysis comprises simulations of the non-equilibrium flow field in the facility nozzle, test box, and flow field over test articles, and comparisons with the measured calibration data.

CFD↗

Asynchronous In Situ Connected-Components Analysis for Complex Fluid flows, In: ISAV '16 Proceedings of the 2nd Workshop on In Situ Infrastructures for Enabling Extreme-scale Analysis and Visualization

The simulation of multiscale physics is an important challenge for scientific computing. For this class of problem, large three-dimensional simulations are performed to advance scientific inquiry. On massively parallel computing systems, the volume of data generated by such approaches can become a productivity bottleneck if the raw data generated from the simulation is analyzed in a post-processing step. To address this, we present a physics-based framework for in situ data reduction that is theoretically grounded in multiscale averaging theory. We show how task parallelism can be exploited to concurrently perform a variety of analysis tasks with data-dependent costs, including the generation of iso-surfaces, morphological analyses, and connected components analysis. All analyses are performed in parallel using distributed memory and use the same domain decomposition as the simulation. A task management framework is constructed to leverage available parallelism within a node for analysis. The capabilities of the framework are to launch asynchronous analysis threads, manage dependencies between different tasks, promote data locality and minimize the impact of data transfers. The framework is applied to analyze GPU-based simulations of two-fluid-phase flow in porous media, generating a set of averaged measures that represents the overall system behavior. We demonstrate how the approach can be applied to perform physically-consistent analysis over fluid sub-regions determined from connected components analysis. Simulations performed on Oak Ridge National Lab's Titan supercomputer are profiled to demonstrate the performance of the associated multi-threaded in situ analysis approach for typical production simulation of two-fluid-phase flow.

Computer Science↗

Studies of the intermediate and deep circulation in the western equatorial Atlantic

This proposal concerns the preparation and design of an experiment, the objective of which is to improve our knowledge of the intermediate and deep circulation in the western equatorial Atlantic Ocean. We shall focus on the description of the western boundary currents, of their crossing with the equator, on the estimation of their mass and heat fluxes, and their seasonal and interannual variations. We will use satellite altimetric data, tomographic measurements, and in situ observations (current measurements, hydrology, and floaters). We propose a feasibility study and the definition of a strategy based on a high-resolution Geophysical Fluid Dynamics Laboratory (GFDL) numerical model to define which in situ measurements are necessary to optimally complete the altimetric observations.

Desaubies, Yves↗

Measurement of Meteor Impact Experiments Using Three-Component Particle Image Velocimetry

The study of hypervelocity impacts has been aggressively pursued for more than 30 years at Ames as a way to simulate meteoritic impacts. Development of experimental methods coupled with new perspectives over this time has greatly improved the understanding of the basic physics and phenomenology of the impact process. These fundamental discoveries have led to novel methods for identifying impact craters and features in craters on both Earth and other planetary bodies. Work done at the Ames Vertical Gun Range led to the description of the mechanics of the Chicxualub crater (a.k.a. K-T crater) on the Yucatan Peninsula, widely considered to be the smoking gun impact that brought an end to the dinosaur era. This is the first attempt in the world to apply three-component particle image velocimetry (3-D PIV) to measure the trajectory of the entire ejecta curtain simultaneously with the fluid structure resulting from impact dynamics. The science learned in these experiments will build understanding in the entire impact process by simultaneously measuring both ejecta and atmospheric mechanics.

Heineck, James T.↗

Blood Vessel Tension Tester

In the photo, a medical researcher is using a specially designed laboratory apparatus for measuring blood vessel tension. It was designed by Langley Research Center as a service to researchers of Norfolk General Hospital and Eastern Virginia Medical School, Norfolk, Virginia. The investigators are studying how vascular smooth muscle-muscle in the walls of blood vessels-reacts to various stimulants, such as coffee, tea, alcohol or drugs. They sought help from Langley Research Center in devising a method of measuring the tension in blood vessel segments subjected to various stimuli. The task was complicated by the extremely small size of the specimens to be tested, blood vessel "loops" resembling small rubber bands, some only half a millimeter in diameter. Langley's Instrumentation Development Section responded with a miniaturized system whose key components are a "micropositioner" for stretching a length of blood vessel and a strain gage for measuring the smooth muscle tension developed. The micropositioner is a two-pronged holder. The loop of Mood vessel is hooked over the prongs and it is stretched by increasing the distance between the prongs in minute increments, fractions of a millimeter. At each increase, the tension developed is carefully measured. In some experiments, the holder and specimen are lowered into the test tubes shown, which contain a saline solution simulating body fluid; the effect of the compound on developed tension is then measured. The device has functioned well and the investigators say it has saved several months research time.

Source record↗