Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

FY12 Summary Report on Liquid-Liquid Contactor Experiments for CFD Model Validation

This report presents a summary of preliminary experiments performed in the latter half of FY12 using the capability of the Contactor Electrical Resistance Tomography (CERT) Facility. This facility includes the capability for multiphase measurements of flow in liquid–liquid contactors using ERT as well as high-speed imaging with the current test focus on an instrumented engineering-scale annular centrifugal contactor having a 5 inch rotor (CINC-V5). In addition, a smaller CINC-V2 (2 inch rotor) contactor was also added to the facility and made possible the exploration of equipment scaling for liquid–liquid operation. The purpose of the efforts during this current FY were to explore a range of flow conditions for multiphase operation to gain broad insight into observable trends and quantities after which detailed measurements will be made for specific controlled test conditions to provide data for validation of advanced computational fluid dynamics models which are being developed under a separate work package (FT-12AN030901). In FY13, this project and the CFD modeling project are to be combined into a single Work Package named “Contactor Modeling and Validation Data”.

42 ENGINEERING↗

Investigating the Influence of Regional Stress on Fault and Fracture Permeability at Pahute Mesa, Nevada National Security Site

Regional stress may exert considerable control on the permeability and hydraulic function (i.e., barrier to and/or conduit for fluid flow) of faults and fractures at Pahute Mesa, Nevada National Security Site (NNSS). In-situ measurements of the stress field are sparse in this area, and short period earthquake focal mechanisms are used to delineate principal horizontal stress orientations. Stress field inversion solutions to earthquake focal mechanisms indicate that Pahute Mesa is located within a transtensional faulting regime, represented by oblique slip on steeply dipping normal fault structures, with maximum horizontal stress ranging from N29°E to N63°E and average of N42°E. Average horizontal stress directions are in general agreement with large diameter borehole breakouts from Pahute Mesa analyzed in this study and with stress measurements from other locations on the NNSS.

54 ENVIRONMENTAL SCIENCES↗

Machine Learning Approaches to Predicting Induced Seismicity and Imaging Geothermal Reservoir Properties

This project developed machine learning (ML) methods, lab data sets, and field data to advance geothermal exploration and geothermal energy production. The work had three focus areas. One involved the development of ML methods to use microearthquakes (MEQs) for imaging geothermal reservoir properties and improving subsurface characterization – most importantly the evolution of permeability within the evolving reservoir. This part of the work included development of ML approaches for automated MEQ location, focal mechanism determination and identification of earthquake precursors. The second area focused on using MEQ signals generated by geothermal exploration and production to predict the relationship between fluid injection and seismicity. Here, we extended to reservoir scale our success in using ML to predict laboratory earthquakes and fault zone stress state. The third focus area was on lab experiments. Here, we developed new ML models for lab earthquake prediction and identification of precursors to failure to improve earthquake forecasting and early warning in geothermal settings. Major outcomes of our work include ML models that learn from MEQ signals during geothermal exploration and production to predict induced seismicity. MEQs occur naturally in connection with drilling and energy production. We developed ML methods to use the seismic waves from these events to characterize the elastic, hydraulic and poromechanical properties of reservoirs. Our work illuminated fracture geometry and the evolution of fracture permeability by incorporating seismic coda wave analysis and ML methods to relate fluid injection and seismicity. We significantly expanded laboratory earthquake prediction to include methods that use both passive measurements of microearthquakes within the lab fault zones and also active source acoustic measurements of fault zone elastic properties. These methods can now predict fault zone stress state, time to failure and the magnitude of lab earthquakes. Our work showed that repetitive stick- slip failure events during frictional sliding (the lab equivalent of earthquakes) are preceded by a cascade of micro-failure events that radiate energy in a manner that foretells unstable failure – manifest as laboratory MEQs. We documented a mapping between fracture properties and statistical attributes of elastic radiation. We extended existing works to geothermal reservoir scale and developed ML methods to determine reservoir permeability, fracture properties, and their evolution during geothermal energy production. An attractive feature of ML algorithms is their ability to handle big datasets and reveal patterns and correlations that may remain invisible to conventional analyses. Our work connected data from field, laboratory and intermediate scales to study permeability, stress, strength, fracture stiffness and geometry. At the field scale we used data from the Newberry Volcano field site, UtahFORGE, EGS Collab, and also the Bedretto underground research lab in Switzerland. These data sets are bridging the gap between the lab scale, theory, and reservoir scale. Our work produced plain language summaries to improve public understanding of DOE research. We also developed openly distributed ML and seismicity datasets for use by all researchers and we published connections between induced seismicity in geothermal areas and reservoir properties including permeability, fracture properties, and stress state. Our models are designed for the large data sets of induced seismicity typically associated with geothermal sites. We produced labeled event catalogs and used them on geothermal data to assess how ML can facilitate geothermal production and exploration. All datasets are available on the GDR Productivity: The project produced 32 publications in peer reviewed journals (two are in review). It supported the work of 6 PhD students, 40 conference presentations, 6 keynote talks at national meetings, and mentoring and professional development for 4 postdoctoral fellows.

15 GEOTHERMAL ENERGY↗

Portable sample preparation and analysis system for micron and sub-micron particle characterization using light scattering and absorption spectroscopy

There is provided a method and device for remote sampling, preparation and optical interrogation of a sample using light scattering and light absorption methods. The portable device is a filtration-based device that removes interfering background particle material from the sample matrix by segregating or filtering the chosen analyte from the sample solution or matrix while allowing the interfering background particles to be pumped out of the device. The segregated analyte is then suspended in a diluent for analysis. The device is capable of calculating an initial concentration of the analyte, as well as diluting the analyte such that reliable optical measurements can be made. Suitable analytes include cells, microorganisms, bioparticles, pathogens and diseases. Sample matrixes include biological fluids such as blood and urine, as well as environmental samples including waste water.

47 OTHER INSTRUMENTATION↗

Tools Assessing Performance (FY2022 Quarter 4 Report)

We were finally successful in acquiring TTU’s 200-meter tower data for the duration of the Isolated Building Wake Experiment (IBWE). This data will provide an independent measurement of the undisturbed wind profile including heights far above those that are typical of meteorological sensor networks. These measurements will characterize the mean and turbulence throughout the atmospheric surface layer, which will be particularly useful for validation of highfidelity computational fluid dynamics models. This dataset can be shared freely among the TAP team but not outside of it as TTU sells this data to the wind power industry. The journal article overview has been submitted to LANL’s publication review and will be submitted to the Journal of Wind Engineering and Industrial Aerodynamics once the review is complete. We are nearing completion on another two articles. The first discusses analyses of the evolution of the measurements of mean wind speed along the centerline of the building as a function of atmospheric stability. Rather than using individual time steps, all of the wind speed measurements are normalized using the upwind measurement at 2 building heights (H) and filtered by wind direction and atmospheric stability. The second discusses the development of the diffusive wake model and uses the averaged profiles from the first article to validate the behavior of the model. The portion of the section below on the diffusive wake model discussing comparisons with the averaged profiles, will be included in the validation section of this paper.

17 WIND ENERGY↗

Direct thrust measurement of a permanent magnet helicon double layer thruster

Direct thrust measurements of a permanent magnet helicon double layer thruster have been made using a pendulum thrust balance and a high sensitivity laser displacement sensor. At the low pressures used (0.08 Pa) an ion beam is detected downstream of the thruster exit, and a maximum thrust force of about 3 mN is measured for argon with an rf input power of about 700 W. The measured thrust is proportional to the upstream plasma density and is in good agreement with the theoretical thrust based on the maximum upstream electron pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of interfacial structures in horizontal air-water bubbly flows

In order to predict multi-dimensional phenomena in nuclear reactor systems, methods relying on computational fluid dynamics (CFD) codes are essential. However, to be applicable in assessing thermal-hydraulic safety, these codes must be able to accurately predict the development of two-phase flows. Therefore, before practical application these codes must be assessed using experimental databases that capture multi-dimensional phenomena. While a large database exists that can be employed to assess predictions in vertical flows, the available database for horizontal flows is significantly lacking. Therefore, the current work seeks to develop an additional database in air-water horizontal bubbly flow through a 38.1 mm ID test section with a total development length of approximately 250 diameters. The experimental conditions are chosen to cover a wide range of the bubbly flow regime based upon flow visualization using a high-speed video camera. A database of local time-averaged void fraction, bubble velocity, interfacial area concentration, and bubble Sauter mean diameter are acquired throughout the pipe cross-section using a four-sensor conductivity probe. To investigate the evolution of the flow, measurements are made at axial locations of 44, 116, and 244 diameters downstream of the inlet. In the current work, only measurements obtained at L/D = 244 are presented. It is found that increasing the liquid superficial velocity tends to reduce both the bubble size and the degree of bubble packing near the upper wall. However, it is observed that the position of the maximum void fraction value remains nearly constant and is located approximately one bubble diameter away from the upper wall. It is also found that the bubble velocity exhibits a power law behavior resembling a single phase liquid turbulent velocity profile. Moreover, the local bubble velocity tends to decrease as the local void fraction increases. Conversely, increasing the gas superficial velocity is found to have little effect on the bubble size or velocity, but increases the bubble packing near the upper pipe wall. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Produced Fluid Induced Mineralogy and Elemental Alterations of Caney Shale, Southern Oklahoma

ABSTRACT This study involves batch reactor experiments and subsequent analyses of samples from Caney Shale in the Ardmore Basin of South-Central Oklahoma. Samples include mainly rock cores and cuttings recovered from two wells respectively drilled vertically through and horizontally across the Caney Shale. Mineralogical compositions are obtained by X-Ray Diffraction (XRD) measurements whilst microstructure and elemental distribution are acquired by Scanning Electron Microscopy/Energy Dispersive Spectroscopy (SEM/EDS) respectively. Batch experiments are then conducted using selected rock samples and produced fluid from the Caney Formation. Deionized water is also reacted with some samples to serve as standard. Experiments are conducted at 95°C and ambient pressure for 7 and 30 days to assess the geochemical rock-fluid interactions. Results show rock mineralogical compositions are predominantly quartz, feldspar, carbonates, and clay with minor pyrite. Post-experimental mineralogical changes observed in samples include increased amorphous entities especially within the clay portions of XRD plots and dissolution of feldspar and carbonate minerals and formation of new mineral phases, mostly clays and salts. These are corroborated by EDS elemental analyses which show decreased elemental compositions. The implications of reactions mentioned above include but not limited to, scale formation, clay fines migration and shale softening all of which pose significant permeability impairment on formation over time. INTRODUCTION Shale reservoirs account for a large share of unconventional reservoirs in the world (Lyu et al., 2015). However, ultra-low permeability and high clay compositions pose significant challenges when producing from these reservoirs (Dawuda and Srinivasan, 2022, 2023). Producing from these reservoirs therefore requires horizontal drilling and hydraulic fracturing technologies which have proven their efficacy in generating substantial permeability in reservoirs to ensure production (Fujian et al., 2019; Liu et al., 2018). Even after expensive horizontal drilling and hydraulic fracturing, geochemical reactions between engineered fluids and formation leads to fracture constriction and adversely impact petrophysical properties (permeability and porosity) of the reservoir. These technologies are therefore under constant development and improvement in various aspects to ensure fine tuning for specific reservoirs. Under present conditions, much of the hydrocarbon reserves in unconventional shale reservoirs are left unproduced due to rapid decline in permeability following resumption to production after hydraulic fracturing. It is therefore essential to understand the range of geochemical reactions that cause rapid depletion of permeability after hydraulic fracturing and apply these to each shale reservoir to ensure substantial recovery rates.

Awejori, G. A.↗

Application of a Geochemically Informed Leak Detection (GILD) Model to CO 2 Injection Sites on the United States Gulf Coast

The Gulf Coast region possesses great potential for CO 2 enhanced oil recovery (EOR) and CO 2 storage. A geochemically informed leak detection (GILD) model has been applied to CO 2 injection sites on the Gulf Coast with considerations of measurement variability. The Jasper aquifer in Montgomery County, Texas, was chosen to demonstrate the method. Based on background data from wells in the area, combinations of mineral and fluid compositions were used to create 23 scenarios for the geochemical model. The output from the geochemical model was used to identify sensitive monitoring species, and response functions were generated for these as a function of the CO 2 leakage concentration. The sources of measurement variability for background conditions were characterized from the Jasper aquifer background data, and then normalized using the coefficient of variation of each species across the monitoring wells. Bayesian belief network (BBN) models were constructed, and measurement variability of different levels were added to compare leak detection probabilities. Increasing measurement variability decreased the power to detect a leak of a given size. For a moderately high CO 2 concentration of 0.2 mol/kg, the probability of detecting this leakage effect using pH as the monitoring variable in an aquifer with calcite decreases from 98% (no measurement variability) to 61% (medium variability) to 33% (high variability). The loss in power of the sampling protocol with increasing measurement variability is similar in magnitude when Ca 2+ or HCO 3 - is used as the monitoring parameter, but only for aquifers with calcite.

58 GEOSCIENCES↗

Λ polarization from vortex rings as the medium response for jet thermalization

We performed a systematic study on the formation of vorticity rings as the process for jet thermalization in the medium created in high-energy nuclear collisions. In this work, we expanded our previous analysis to a more realistic framework by considering noncentral events and fluctuations in the initial condition. We simulate the formation and evolution of the flow vortex structure in a relativistic viscous hydrodynamic model and study the sensitivity of the proposed “ring observable” (ℛ$^{𝑡}_{Λ}$) that can be measured experimentally through the polarization of Λ hyperons. We show that this observable is robust with respect to fluctuating initial conditions to capture the jet-induced vortex flow signal and further study its dependence on different model parameters, such as the jet's velocity, position, the fluid's shear viscosity, and the collision centrality. The proposed observable is associated with the formation of vorticity in a quark-gluon plasma, showing that the measurement of particle polarization can be a powerful tool to probe different properties of jet-medium interactions and to understand better the polarization induced by the transverse and longitudinal expansions of the medium.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigations into the feasibility of optical-CT 3D dosimetry with minimal use of refractively matched fluids

Purpose: In optical-CT, the use of a refractively matched polyurethane solid-tank in place of a fluid bath has the potential to greatly increase practical convenience, reduce cost, and possibly improve the efficacy of flood corrections. This work investigates the feasibility of solid-tank optical-CT imaging for 3D dosimetry through computer simulation. Methods: A MATLAB ray-tracing simulation platform, ScanSim, was used to model a parallel-source telecentric optical-CT imaging system through a polyurethane solid-tank containing a central cylindrical hollow into which PRESAGE radiochromic dosimeters can be placed. A small amount of fluid fills the 1–5 mm gap between the dosimeter and the walls of the tank. The use of the solid-tank reduces the required amount of fluid by approximately 97%. To characterize the efficacy of solid-tank, optical-CT scanning simulations investigated sensitivity to refractive index (RI) mismatches between dosimeter, solid-tank, and fluid, for a variety of dosimeter (RI = 1.5–1.47) and fluid (RI = 1.55–1.0) combinations. Efficacy was evaluated through the usable radius (r{sub u}) metric, defined as the fraction of the radius of the dosimeter where measured dose is predicted to be within 2% of the ground truth entered into the simulation. Additional simulations examined the effect of increasing gap size (1–5 mm) between the dosimeter and solid-tank well. The effects of changing the lens tolerance (0.5°–5.0°) were also investigated. Results: As the RI mismatch between the dosimeter and solid-tank increased from 0 to 0.02, the usable radius decreased from 97.6% to 50.2%. The optimal fluid RI decreased nonlinearly from 1.5 to 1.34 as the mismatch increased and was up to 9% lower than the tank. Media mismatches between the dosimeter and solid-tank also exacerbate the effects of changing the gap size, with no easily quantifiable relationship with usable radius. Generally, the optimal fluid RI value increases as gap size increases and is closely matched to the dosimeter at large gap sizes (>3 mm). Increasing the telecentric lens tolerance increases the usable radius for all refractive media combinations and improves the maximum usable radius of mismatched media to that of perfectly matched media for tolerances >5.0°. The maximum usable radius can be improved up to a factor of 2 when lens tolerances are small (<1.0°). Conclusions: Dry solid-tank optical-CT imaging in a telecentric system is feasible if the dosimeter RI is a close match with the solid-tank (<0.01 difference), providing accurate dose measurements within ±2% of true dose to over 80% of the dosimeter volume. In order to achieve accurate measurements over 96% of the dosimeter volume (representing out to 2 mm from the dosimeter edge), the dosimeter-tank RI mismatch must be less than 0.005. Optimal results occur when the RI of the dosimeter and tank is the same, in which case the fluid will have the same RI. If mismatches between the tank and dosimeter RI occur, the RI of the matching fluid needs to be fine tuned to achieve the highest usable radius.

61 RADIATION PROTECTION AND DOSIMETRY↗

Precise relative magnitude measurement improves fracture characterization during hydraulic fracturing

SUMMARY Microseismic monitoring is an important technique to obtain detailed knowledge of in-situ fracture size and orientation during stimulation to maximize fluid flow throughout the rock volume and optimize production. Furthermore, considering that the frequency of earthquake magnitudes empirically follows a power law (i.e. Gutenberg–Richter), the accuracy of microseismic event magnitude distributions is potentially crucial for seismic risk management. In this study, we analyse microseismicity observed during four hydraulic fracture treatments of the legacy Cotton Valley experiment in 1997 at the Carthage gas field of East Texas, where fractures were activated at the base of the sand-shale Upper Cotton Valley formation. We perform waveform cross-correlation to detect similar event clusters, measure relative amplitude from aligned waveform pairs with a principal component analysis, then measure precise relative magnitudes. The new magnitudes significantly reduce the deviations between magnitude differences and relative amplitudes of event pairs. This subsequently reduces the magnitude differences between clusters located at different depths. Reduction in magnitude differences between clusters suggests that some attenuation-related biases could be effectively mitigated with relative magnitude measurements. The maximum likelihood method is applied to understand the magnitude frequency distributions and quantify the seismogenic index of the clusters. Statistical analyses with new magnitudes suggest that fractures that are more favourably oriented for shear failure have lower b-value and higher seismogenic index, suggesting higher potential for relatively larger earthquakes, rather than fractures subparallel to maximum horizontal principal stress orientation.

58 GEOSCIENCES↗

Thermodiffusion in concentrated ferrofluids: Experimental and numerical results on magnetic thermodiffusion

Ferrofluids consist of magnetic nanoparticles dispersed in a carrier liquid. Their strong thermodiffusive behaviour, characterised by the Soret coefficient, coupled with the dependency of the fluid's parameters on magnetic fields is dealt with in this work. It is known from former experimental investigations on the one hand that the Soret coefficient itself is magnetic field dependent and on the other hand that the accuracy of the coefficient's experimental determination highly depends on the volume concentration of the fluid. The thermally driven separation of particles and carrier liquid is carried out with a concentrated ferrofluid (φ = 0.087) in a horizontal thermodiffusion cell and is compared to equally detected former measurement data. The temperature gradient (1 K/mm) is applied perpendicular to the separation layer. The magnetic field is either applied parallel or perpendicular to the temperature difference. For three different magnetic field strengths (40 kA/m, 100 kA/m, 320 kA/m) the diffusive separation is detected. It reveals a sign change of the Soret coefficient with rising field strength for both field directions which stands for a change in the direction of motion of the particles. This behaviour contradicts former experimental results with a dilute magnetic fluid, in which a change in the coefficient's sign could only be detected for the parallel setup. An anisotropic behaviour in the current data is measured referring to the intensity of the separation being more intense in the perpendicular position of the magnetic field: S{sub T‖} = −0.152 K{sup −1} and S{sub T⊥} = −0.257 K{sup −1} at H = 320 kA/m. The ferrofluiddynamics-theory (FFD-theory) describes the thermodiffusive processes thermodynamically and a numerical simulation of the fluid's separation depending on the two transport parameters ξ{sub ‖} and ξ{sub ⊥} used within the FFD-theory can be implemented. In the case of a parallel aligned magnetic field, the parameter can be determined to ξ{sub ‖} = (2.8; 9.1; 11.2) × 10{sup −11} · D{sub ‖} kg/(A{sup 2}m) for the different field strengths and in dependence on the magnetic diffusion coefficient D{sub ‖}. An adequate fit in the perpendicular case is not possible, by ξ{sub ⊥} = 1 × 10{sup −17} kg/(Am{sup 2}) a rather good agreement between numerical and experimental data can be found for a field strength of 40 kA/m, a change in the coefficient's sign in the perpendicular setup is not numerically determinable via this theory. The FFD-theory is only partly applicable to calculate the concentration profile in concentrated magnetic fluids established due to a temperature gradient and magnetic field applied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validation of Pronghorn for Natural-Circulation Molten Salt Loops

This paper presents the development and validation of a high-fidelity thermal-hydraulic model of a molten salt natural circulation flow loop, designed for integration within a digital twin framework. The study evaluates the performance of Idaho National Laboratory’s Pronghorn against experimental data from Texas A&M University Molten Salt Flow Loop (MSFL) four Hitec-salt test benchmark data. Natural circulation of high-Prandtl-number fluids exhibits complex, counter-intuitive flow patterns that make pointwise thermocouple readings unreliable. Experimental work at TAMU’s MSFL provides benchmark data, including flow visualization at a test-section and centerline steady-state temperature measurements along the loop. Validation includes four single-phase natural circulation test cases with Hitec salt. Key metrics include flow profile agreement and steady-state temperature accuracy. Pronghorn results for two-dimensional single-phase agree qualitatively with the experimental flow profile. This paper illustrates the importance of Computational Fluid Dynamics (CFD) in elucidating the behavior of high-Prandtl-number thermal-hydraulics, along with how misleading centerline temperature measurements can be. Pronghorn reproduces the axial and radial stratification that makes single thermocouple readings unreliable. Future research will focus on reduced-order modeling techniques to enable rapid simulation suitable for real-time digital twin applications. The validated cases provide a basis for developing reduced-order surrogates aimed at real-time digital-twin applications.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental Poroviscoelasticity of Common Sedimentary Rocks

The success of geoenergy applications such as petroleum recovery or geological storage of CO 2 depends on properly addressing the physical coupling between the pore fluid diffusion and mechanical deformation of the subsurface rock. Constitutive models should include short-term hydromechanical interactions and long-term behavior and should incorporate the principles behind the mathematical models for poroelastic and poroviscoelastic responses. However, the viscous parameters in constitutive relationships still need to be validated and estimated. In this work, we experimentally quantify the time-dependent response of fluid-filled sedimentary rocks at room temperature and isotropic stress states. Drained, undrained, and unjacketed geomechanical tests are performed to measure the poroelastic parameters for Berea sandstone, Apulian limestone, clay-rich material, and Opalinus clay (shale). A poroviscous model parameter, the bulk viscosity, is included in the constitutive relationships. The bulk viscosity is estimated under constant isotropic stress conditions from time-dependent deformation of rock in the drained regime for timescales ~10 5 s and from observations of the pore pressure growth under undrained conditions at timescales of ~10 4 s. The bulk viscosity is on the order of 10 15 –10 16 Pa s for sandstone, limestone, and shale and ~10 13 Pa s for clay-rich material, and it decreases with an increase in pore pressure despite a corresponding decrease in the effective stress. In the long term, fluid pressure can asymptotically approach minimum principal stress, which in natural reservoirs may lead to liquefaction or rock embrittlement, causing slip instabilities and earthquakes and creating high-permeability channels in low-permeable rock.

58 GEOSCIENCES↗

Pool boiling heat transfer evaluation of next-generation dielectric fluid: Opteon™ 2P50

The growing use of artificial intelligence has led to heavy thermal loads and high heat dissipation rates in data centers. Conventional air-cooled technologies are not able to fulfill these requirements. To overcome these challenges, two-phase immersion cooling (2PIC) has emerged as one of the leading technologies for high power-density chips. 2PIC increases the heat dissipation rate and efficiency of the system while reducing the footprint of the cooling equipment. A fluid with adequate dielectric properties, a suitable normal boiling temperature to maintain chip temperatures, and good material compatibility, is desired for 2PIC system. In this study, the pool boiling heat transfer of a new developmental dielectric fluid, Opteon™ 2P50, was experimentally investigated. The heat transfer coefficients at various heat fluxes (20–150 kW/m 2 ) and the critical heat flux were measured using a smooth aluminum surface. Compared with HFE-7100, Opteon™ 2P50 shows higher heat transfer coefficient (up to 59% higher) and a slightly lower value of critical heat flux (around 5.9% lower). The modified Cooper correlation with the optimized leading constant resulted in reliable prediction accuracy with a 5.3% mean absolute error percentage. Overall, these results indicate that the new dielectric fluid provides similar thermal performance to some legacy fluids.

2P50↗

Interpretation of Ground Temperature Anomalies in Hydrothermal Discharge Areas

Abstract Researchers have long noted the potential for shallow hydrothermal fluids to perturb near‐surface temperatures. Several investigators have made qualitative or semiquantitative use of elevated surface temperatures; for example, in snowfall calorimetry, or for tracing subsurface flow paths. However, a quantitative framework connecting surface temperature observations with conditions in the subsurface is currently lacking. Here, we model an area of shallow subsurface flow at Burgdorf Hot Springs, a rustic commercial resort in the Payette National Forest, north of McCall, ID, USA. We calibrate the model using shallow (0.2 m depth) ground temperature measurements and overburden thickness estimates from seismic refraction studies. The calibrated model predicts negligible loss of heat energy from the laterally migrating fluids at the Burgdorf site, in spite of the fact that thermal anomalies are observed in the unconsolidated near‐surface alluvium. Although elevated near‐surface ground temperatures are commonly assumed to result from locally high heat flux, this conflicts with the small apparent heat loss during lateral flow inferred at the Burgdorf site. We hypothesize an alternative explanation for near‐surface temperature anomalies that is only weakly dependent on heat flux, and more strongly controlled by the Biot number, a dimensionless parameter that compares the rate at which convection carries heat away from the land surface to the rate at which it is supplied by conduction to the interface.

Price, Adam N.↗

SU-E-T-294: Simulations to Investigate the Feasibility of ‘dry’ Optical-CT Imaging for 3D Dosimetry

Purpose: To perform simulations investigating the feasibility of “dry” optical-CT, and determine optimal design and scanning parameters for a novel dry tank telecentric optical-CT 3D dosimetry system. Such a system would have important advantages in terms of practical convenience and reduced cost. Methods: A Matlab based ray-tracing simulation platform, ScanSim, was used to model a telecentric system with a polyurethane dry tank, cylindrical dosimeter, and surrounding fluid. This program's capabilities were expanded for the geometry and physics of dry scanning. To categorize the effects of refractive index (RI) mismatches, simulations were run for several dosimeter (RI = 1.5−1.48) and fluid (RI = 1.55−1.33) combinations. Additional simulations examined the effect of increasing gap size (1–5mm) between the dosimeter and tank wall, and of changing the telecentric lens tolerance (0.5°−5°). The evaluation metric is the usable radius; the distance from the dosimeter center where the measured and true doses differ by less than 2%. Results: As the tank/dosimeter RI mismatch increases from 0–0.02, the usable radius decreases from 97.6% to 50.2%. The fluid RI for matching is lower than either the tank or dosimeter RI. Changing gap sizes has drastic effects on the usable radius, requiring more closely matched fluid at large gap sizes. Increasing the telecentric tolerance through a range from 0.5°–5.0° improved the usable radius for every combination of media. Conclusion: Dry optical-CT with telecentric lenses is feasible when the dosimeter and tank RIs are closely matched (<0.01 difference), or when data in the periphery is not required. The ScanSim tool proved very useful in situations when the tank and dosimeter have slight differences in RI by enabling estimation of the optimal choice of RI of the small amount of fluid still required. Some spoiling of the telecentric beam and increasing the tolerance helps recover the usable radius.

07 ISOTOPE AND RADIATION SOURCES↗