Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE ALIGNMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Alignment of the Grating Wheel Mechanism for a Ground-Based, Cryogenic, Near-Infrared Astronomy Instrument

We describe the population, optomechanical alignment, and alignment verification of near-infrared gratings on the grating wheel mechanism (GWM) for the Infrared Multi-Object Spectrometer (IRMOS). IRMOS is a cryogenic (80 K), principle investigator-class instrument for the 2.1 m and Mayall 3.8 m telescopes at Kitt Peak National Observatory, and a MEMS spectrometer concept demonstrator for the James Webb Space Telescope. The GWM consists of 13 planar diffraction gratings and one flat imaging mirror (58 x 57 mm), each mounted at a unique compound angle on a 32 cm diameter gear. The mechanism is predominantly made of Al 6061. The grating substrates are stress relieved for enhanced cryogenic performance. The optical surfaces are replicated from off-the-shelf masters. The imaging mirror is diamond turned. The GWM spans a projected diameter of approx. 48 cm when fully assembled, utilizes several flexure designs to accommodate potential thermal gradients, and is controlled using custom software with an off-the-shelf controller. Under ambient conditions, each grating is aligned in six degrees of freedom relative to a coordinate system that is referenced to an optical alignment cube mounted at the center of the gear. The local tip/tilt (Rx/Ry) orientation of a given grating is measured using the zero-order return from an autocollimating theodolite. The other degrees of freedom are measured using a two-axis cathetometer and rotary table. Each grating's mount includes a one-piece shim located between the optic and the gear. The shim is machined to fine align each grating. We verify ambient alignment by comparing grating difractive properties to model predictions.

Gutkowski, Sharon M.↗

Multipoint Observations of Dispersive Scale Alfvénic Field‐Line Resonances Associated With Substorm Auroral Beads

We present a case study of the field-aligned current (FAC) systems that transpire within the high-altitude auroral acceleration region of an “auroral bead” initiated double oval substorm observed on 23 February 2001 by the Cluster fleet. Conjunctive Cluster measurements and auroral images from IMAGE reveal that auroral bead current system formation and evolution is a multi-scale, injection-mediated process. The FACs at large scales vary on substorm evolution time scales (~minutes) in response to the injection and evolution of hotter denser magnetospheric plasma. Embedded within the large-scale FACs are intense short-scale (≲ few 10s of km) currents comprising dispersive scale Alfvén wave (DAW) fluctuations. The DAWs are a complex mixture of ingoing and reflected components that regularly interfere to form a broad spectrum of kinetic (dispersive) scale Alfvénic field-line resonances (KFLRs). The Alfvénic currents appear as a nested series of upward and downward FAC densities with amplitudes reaching a few 100 nA/m 2 . Energized field-aligned or counterstreaming electrons near keV energies and below are observed with parallel skews that vary in concert with variations in the DAW current sense. Positive correlations between DAW electric field energy densities and the energies of energized H + , He + , and O + outflow are observed, indicative of ion energization within the DAW fields. Due to their L-shell location (L~5.8–7.0) and associations with injections, the KFLRs are interpreted as the high-altitude auroral zone analog of KFLRs observed in the equatorial inner magnetosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-44: A Novel Approach to Quantify Patient Setup and Target Motion for Real-Time Image-Guided Radiotherapy (IGRT)

Purpose Isocenter shifts and rotations to correct patient setup errors and organ motion cannot remedy some shape changes of large targets. We are investigating new methods in quantification of target deformation for realtime IGRT of breast and chest wall cancer. Methods Ninety-five patients of breast or chest wall cancer were accrued in an IRB-approved clinical trial of IGRT using 3D surface images acquired at daily setup and beam-on time via an in-room camera. Shifts and rotations relating to the planned reference surface were determined using iterative-closest-point alignment. Local surface displacements and target deformation are measured via a ray-surface intersection and principal component analysis (PCA) of external surface, respectively. Isocenter shift, upper-abdominal displacement, and vectors of the surface projected onto the two principal components, PC1 and PC2, were evaluated for sensitivity and accuracy in detection of target deformation. Setup errors for some deformed targets were estimated by superlatively registering target volume, inner surface, or external surface in weekly CBCT or these outlines on weekly EPI. Results Setup difference according to the inner-surface, external surface, or target volume could be 1.5 cm. Video surface-guided setup agreed with EPI results to within < 0.5 cm while CBCT results were sometimes (∼20%) different from that of EPI (>0.5 cm) due to target deformation for some large breasts and some chest walls undergoing deep-breath-hold irradiation. Square root of PC1 and PC2 is very sensitive to external surface deformation and irregular breathing. Conclusion PCA of external surfaces is quick and simple way to detect target deformation in IGRT of breast and chest wall cancer. Setup corrections based on the target volume, inner surface, and external surface could be significant different. Thus, checking of target shape changes is essential for accurate image-guided patient setup and motion tracking of large deformable targets. NIH grant for the first author as cionsultant and the last author as the PI.

60 APPLIED LIFE SCIENCES↗

Fiber orientation effects on ultra-high performance concrete formed by 3D printing

Despite the growing interest in 3D concrete printing, its current progress is limited by reinforcing methods. Inclusion of steel fibers is a potential reinforcing solution; however, the effect of printing process on orientation of the fibers is still unknown. This study aims to quantitatively investigate the orientation distribution of steel fibers in 3D printed ultra-high performance concrete. The effects of extrusion nozzle size, Cartesian print speed, and fiber volume fraction on the orientation of fibers were evaluated using digital image analysis. The consequent effects of the fiber orientation on the mechanical properties of the 3D-printed specimens were also determined. The results were compared with those of the conventionally mold-cast specimens. The results revealed that the smaller nozzle size and higher fiber volume fraction significantly enhanced the fiber alignment parallel to the printing direction. This preferential fiber alignment led to superior mechanical performance of the printed specimens to the mold-cast specimens.

36 MATERIALS SCIENCE↗

Gamma-ray imaging and holdup assays of 235-F PuFF cells 1 & 2

Savannah River National Laboratory (SRNL) Nuclear Measurements (L4120) was tasked with performing enhanced characterization of the holdup in the PuFF shielded cells. Assays were performed in accordance with L16.1-ADS-2460 using two high-resolution gamma-ray detectors. The first detector, an In Situ Object Counting System (ISOCS)-characterized detector, was used in conjunction with the ISOCS Geometry Composer software to quantify grams of holdup. The second detector, a Germanium Gamma-ray Imager (GeGI), was used to visualize the location and relative intensity of the holdup in the cells. Carts and collimators were specially designed to perform optimum assays of the cells. Thick, pencil-beam tungsten collimators were fabricated to allow for extremely precise targeting of items of interest inside the cells. Carts were designed with a wide range of motion to position and align the detectors. A total of 24 measurements were made, each typically 24 hours or longer to provide sufficient statistical precision. This report presents the results of the enhanced characterization for cells 1 and 2. The measured gram values agree very well with results from the 2014 study. In addition, images were created using both the 2014 data and the new GeGI data. The GeGI images of the cells walls reveal significant Pu-238 holdup on the surface of the walls in cells 1 and 2. Additionally, holdup is visible in the two pass-throughs from cell 1 to the wing cabinets. This report documents the final element (exterior measurements coupled with gamma-ray imaging and modeling) of the enhanced characterization of cells 1-5 (East Cell Line).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility of Multimodal Deformable Registration for Head and Neck Tumor Treatment Planning

Purpose: To investigate the feasibility of using deformable registration in clinical practice to fuse MR and CT images of the head and neck for treatment planning. Method and Materials: A state-of-the-art deformable registration algorithm was optimized, evaluated, and compared with rigid registration. The evaluation was based on manually annotated anatomic landmarks and regions of interest in both modalities. We also developed a multiparametric registration approach, which simultaneously aligns T1- and T2-weighted MR sequences to CT. This was evaluated and compared with single-parametric approaches. Results: Our results show that deformable registration yielded a better accuracy than rigid registration, without introducing unrealistic deformations. For deformable registration, an average landmark alignment of approximatively 1.7 mm was obtained. For all the regions of interest excluding the cerebellum and the parotids, deformable registration provided a median modified Hausdorff distance of approximatively 1 mm. Similar accuracies were obtained for the single-parameter and multiparameter approaches. Conclusions: This study demonstrates that deformable registration of head-and-neck CT and MR images is feasible, with overall a significanlty higher accuracy than for rigid registration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unraveling the Mechanism of Interfacial Charge Transfer and Photoresponsivity of WS 2 Quantum Dots/MoS 2 (0D–2D) Heterostructure-Based Transistors

To assess the efficacy of a mixed-dimensional van der Waals (vdW) heterostructure in modulating the optoelectronic responses of nanodevices, the charge transport properties of the transition-metal dichalcogenide (TMD)-based heterostructure comprising zero-dimensional (0D) WS 2 quantum dots (QDs) and two-dimensional (2D) MoS 2 flakes are critically analyzed. Herein, a facile strategy was materialized in developing an atomically thin phototransistor assembled from mechanically exfoliated MoS 2 and WS 2 QDs synthesized using a one-pot hydrothermal route. The amalgamated photodetectors exhibited a high responsivity of ∼8000 A/W at an incident power of 0.05 nW of white light, surpassing that of the pristine MoS 2 devices. Furthermore, the detectivity of pristine MoS 2 , which was on the order of 10 10 , increased to 10 12 Jones for the WS 2 QDs/MoS 2 heterostructure photodetector, outperforming other WS 2 -based materials. The quasiparticle band gap and density of states (DOS) are further analyzed to elucidate the photophysics of the WS 2 QD/MoS 2 hybrid assembly. The difference in the work function between MoS 2 and WS 2 QDs gives rise to an electric field across the 0D–2D interface, facilitating effective charge separation and migration and contributing to the enhancement of photoresponsivity. The analysis of optical responses using density functional theory (DFT) revealed stronger absorption and less reflection over a broader spectrum of wavelengths for the heterostructure compared to the pristine materials. The estimated optical conductivity aligns well with the experimentally predicted maximum photoresponsivity under visible light, which is attributed to the high absorbance of 2D MoS 2 . In conclusion, combining diverse spectroscopic and imaging techniques with quantum simulation provides insights that clarify the pertinence of 0D–2D TMDs in designing phototransistors.

WS2 QDs/MoS2 heterostructure↗

Nuclear imaging to diagnose and correct target-driver registration at high-repetition-rate for improved reactor efficiency

Inertial Confinement Fusion produces energy from a burning plasma lasting a fraction of a nanosecond. Power plant designs based on Inertial Fusion Energy (IFE) will need to ignite targets 1-10 times a second, fired as projectiles into a chamber and delivering the driver to the target location. Driver asymmetry is known to impact ICF experiments at gain near unity and remains a candidate for primary yield degradation, and therefore fusion power plant energy output, for high-gain target designs. For a Fusion Power Plant (FPP), continuous and real-time monitoring of target performance provides an opportunity to stabilize or correct the target-driver registration. This requires x-ray and neutron imaging with a large field-of-view, sufficiently high resolution, fast analysis and to subtend a minimal solid angle. We introduce design criteria for such an imaging system that uses a coded aperture and time-gated, lens-coupled scintillators as a viable solution and outline the research steps required to field such a system. Integrating the imaging system into an IFE power plant as part of an active feedback loop could increase average power output by reducing the failure rate due to mis-aligned drivers with respect to the target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental test of magnetospheric models.

The barium cloud injection deep into the magnetosphere of Sept. 21, 1971, has revealed that the quiet-time near-equatorial nightside magnetic field is significantly different from that predicted by existing quite-time models. The influence of currents flowing on or near the geomagnetic equator gives the field a more tail-like structure at a distance as close as 5 earth radii. Several models have been tried out to obtain a best fit to the experimental observations of the shape of the field-aligned ion cloud. Although this method does not lead to a unique solution, the most acceptable option emerging from this analysis is a quiet-time tilted image-dipole model with a Williams-Mead tail field and a disclike ring current on the geomagnetic equator.

Barish, F. D.↗

Mesoscale waves as a probe of Jupiter's deep atmosphere

Images from the Voyager north/south mapping sequences were searched for waves. A remarkable class of mesoscale waves was identified, with the following features: (1) the wavetrains are usually aligned zonally, i.e., wavecrests are north-south; (2) the average wavelength is 300 km with a standard deviation of only 20%; (3) the wavetrains are long; (4) the waves occur within 25 degrees of the equator, the bulk being at the equator itself; (5) the waves are centered at the extrema (in latitude) of the zonal flow; and (6) the meridional extent of the waves is typically 1 degree of latitude. These observations are interpreted as evidence of gravity waves propagating vertically within a leaky duct. A three-level model is assumed composed of a stable duct which extends up to the base of the NH3 cloud deck near 600 mb. Above this is a thin wave-trapping region characterized by a Richardson number Ri less than 1/4 and containing a critical level, where the local value of the zonal flow velocity equals the phase speed of the wave. This in turn is overlain by a stable region, representing the tropopause region and stratosphere.

Flaser, F. M.↗

Ultrasonic and radiographic evaluation of advanced aerospace materials: Ceramic composites

Two conventional nondestructive evaluation techniques were used to evaluate advanced ceramic composite materials. It was shown that neither ultrasonic C-scan nor radiographic imaging can individually provide sufficient data for an accurate nondestructive evaluation. Both ultrasonic C-scan and conventional radiographic imaging are required for preliminary evaluation of these complex systems. The material variations that were identified by these two techniques are porosity, delaminations, bond quality between laminae, fiber alignment, fiber registration, fiber parallelism, and processing density flaws. The degree of bonding between fiber and matrix cannot be determined by either of these methods. An alternative ultrasonic technique, angular power spectrum scanning (APSS) is recommended for quantification of this interfacial bond.

Generazio, Edward R.↗

Monitoring of the Greenland Ice Sheet using ERS-1 synthetic aperture radar imagery

ERS-1 Synthetic Aperture Radar (SAR) imagery is shown to be suitable for monitoring the climate of the Greenland ice sheet and for measuring changes in its marginal position. Four distinct hydrologic zones are easily recognized. Zone boundaries align closely with elevation. Seasonal changes in at least one of these zones indicate that late Winter is a better time than late Summer for the collection of images intended for long term monitoring. Subtle variations of the backscatter intensity from the highest portions of the ice sheet where melting never occurs are believed to indicate surface topography.

Bindschadler, Robert↗

SOHO-Ulysses Coordinated Studies During the Two Extended Quadratures and the Radial Alignment of 2007-2008

During quadrature, plasma seen on the limb of the Sun, along the radi al direction to Ulysses, by SOHO or STEREO can be sampled in situ as lt later passes Ulysses. A figure shows a coronagraph image, the rad ial towards Ulysses at 58 deg. S. and the SOHO/UVCS slit positions d uring one set of observations. A CME subsequently occurred and passed Ulysses (at 3/4 AU) 15 days later.

Suess, S. T.↗

Pattern-Recognition System for Approaching a Known Target

A closed-loop pattern-recognition system is designed to provide guidance for maneuvering a small exploratory robotic vehicle (rover) on Mars to return to a landed spacecraft to deliver soil and rock samples that the spacecraft would subsequently bring back to Earth. The system could be adapted to terrestrial use in guiding mobile robots to approach known structures that humans could not approach safely, for such purposes as reconnaissance in military or law-enforcement applications, terrestrial scientific exploration, and removal of explosive or other hazardous items. The system has been demonstrated in experiments in which the Field Integrated Design and Operations (FIDO) rover (a prototype Mars rover equipped with a video camera for guidance) is made to return to a mockup of Mars-lander spacecraft. The FIDO rover camera autonomously acquires an image of the lander from a distance of 125 m in an outdoor environment. Then under guidance by an algorithm that performs fusion of multiple line and texture features in digitized images acquired by the camera, the rover traverses the intervening terrain, using features derived from images of the lander truss structure. Then by use of precise pattern matching for determining the position and orientation of the rover relative to the lander, the rover aligns itself with the bottom of ramps extending from the lander, in preparation for climbing the ramps to deliver samples to the lander. The most innovative aspect of the system is a set of pattern-recognition algorithms that govern a three-phase visual-guidance sequence for approaching the lander. During the first phase, a multifeature fusion algorithm integrates the outputs of a horizontal-line-detection algorithm and a wavelet-transform-based visual-area-of-interest algorithm for detecting the lander from a significant distance. The horizontal-line-detection algorithm is used to determine candidate lander locations based on detection of a horizontal deck that is part of the lander.

Huntsberger, Terrance↗

NASA Tech Briefs, October 2010

Topics covered include: Hybrid Architecture Active Wavefront Sensing and Control; Carbon-Nanotube-Based Chemical Gas Sensor; Aerogel-Positronium Technology for the Detection of Small Quantities of Organic and/or Toxic Materials; Graphene-Based Reversible Nano-Switch/Sensor Schottky Diode; Inductive Non-Contact Position Sensor; High-Temperature Surface-Acoustic-Wave Transducer; Grid-Sphere Electrodes for Contact with Ionospheric Plasma; Enabling IP Header Compression in COTS Routers via Frame Relay on a Simplex Link; Ka-Band SiGe Receiver Front-End MMIC for Transponder Applications; Robust Optimization Design Algorithm for High-Frequency TWTs; Optimal and Local Connectivity Between Neuron and Synapse Array in the Quantum Dot/Silicon Brain; Method and Circuit for In-Situ Health Monitoring of Solar Cells in Space; BGen: A UML Behavior Network Generator Tool; Platform for Post-Processing Waveform-Based NDE; Electrochemical Hydrogen Peroxide Generator; Fabrication of Single, Vertically Aligned Carbon Nanotubes in 3D Nanoscale Architectures; Process to Create High-Fidelity Lunar Dust Simulants; Lithium-Ion Electrolytes Containing Phosphorous-Based, Flame-Retardant Additives; InGaP Heterojunction Barrier Solar Cells; Straight-Pore Microfilter with Efficient Regeneration; Determining Shear Stress Distribution in a Laminate; Self-Adjusting Liquid Injectors for Combustors; Handling Qualities Prediction of an F-16XL-Based Reduced Sonic Boom Aircraft; Tele-Robotic ATHLETE Controller for Kinematics - TRACK; Three-Wheel Brush-Wheel Sampler; Heterodyne Interferometer Angle Metrology; Aligning Astronomical Telescopes via Identification of Stars; Generation of Optical Combs in a WGM Resonator from a Bichromatic Pump; Large-Format AlGaN PIN Photodiode Arrays for UV Images; Fiber-Coupled Planar Light-Wave Circuit for Seed Laser Control in High Spectral Resolution Lidar Systems; On Calculating the Zero-Gravity Surface Figure of a Mirror; Optical Modification of Casimir Forces for Improved Function of Micro- and Nano-Scale Devices; Analysis, Simulation, and Verification of Knowledge-Based, Rule-Based, and Expert Systems; Core and Off-Core Processes in Systems Engineering; Digital Reconstruction Supporting Investigation of Mishaps; and Template Matching Approach to Signal Prediction.

Source record↗

Stroboscopic Interferometer for Measuring Mirror Vibrations

Stroboscopic interferometry is a technique for measuring the modes of vibration of mirrors that are lightweight and, therefore, unavoidably flexible. The technique was conceived especially for modal characterization of lightweight focusing mirror segments to be deployed in outer space; however, the technique can be applied to lightweight mirrors designed for use on Earth as well as the modal investigation of other optical and mechanical structures. To determine the modal structure of vibration of a mirror, it is necessary to excite the mirror by applying a force that varies periodically with time at a controllable frequency. The excitation can utilize sinusoidal, square, triangular, or even asynchronous waveforms. Because vibrational modes occur at specific resonant frequencies, it is necessary to perform synchronous measurements and sweep the frequency to locate the significant resonant modes. For a given mode it is possible to step the phase of data acquisition in order to capture the modal behavior over a single cycle of the resonant frequency. In order to measure interferometrically the vibrational response of the mirror at a given frequency, an interferometer must be suitably aligned with the mirror and adjustably phase-locked with the excitation signal. As in conventional stroboscopic photography, the basic idea in stroboscopic interferometry is to capture an image of the shape of a moving object (in this case, the vibrating mirror) at a specified instant of time in the vibration cycle. Adjusting the phase difference over a full cycle causes the interference fringes to vary over the full range of motion for the mode at the excitation frequency. The interference-fringe pattern is recorded as a function of the phase difference, and, from the resulting data, the surface shape of the mirror for the given mode is extracted. In addition to the interferometer and the mirror to be tested, the equipment needed for stroboscopic interferometry includes an arbitrary-function generator (that is, a signal generator), an oscilloscope, a trigger filter, and an advanced charge-coupled-device (CCD) camera. The optical components are positioned to form a pupil image of the mirror under test on the CCD chip, so that the interference pattern representative of the instantaneous mirror shape is imaged on the CCD chip.

Stahl, H. Philip↗

Evidence for Two Separate but Interlaced Components of the Chromospheric Magnetic Field

Chromospheric fibrils are generally thought to trace out horizontal magnetic fields that fan out from flux concentrations in the photosphere. A high-resolution (0.2") image taken in the core of the Ca IJ854.2 nm line shows the dark fibrils within an active region remnant as fine, loop-like features that are aligned parallel to each other and have lengths on the order of a supergranular diameter (approx.30 Mm). Comparison with a line-of-sight magnetogram confirms that the fibrils are centered above intranetwork areas, with one end rooted just inside the neighboring plage or strong unipolar network but the other endpoint less clearly defined. Focusing on a particular arcade-like structure lying entirely on one side of a filament channel (large-scale polarity inversion), we find that the total amount of positive-polarity flux underlying this "fibril arcade' is 50 times greater than the total amount of negative-polarity flux. Thus, if the fibrils represent closed loops, they must consist of very weak fields (in terms of flux density), which are interpenetrated by a more vertical field that contains most of the flux. This surprising result suggests that the fibrils in unipolar regions connect the network to the nearby intranetwork flux, while the bulk of the network flux is diverted upward into the corona and connects to remote regions of the opposite polarity. We conclude that the chromospheric field near the edge of the network has an interlaced structure resembling that in sunspot penumbrae, with the fibrils representing the low-lying horizontal flux that remains trapped within the highly nonpotential chromospheric layer.

Muglach, K.↗

Hubble Space Telescope Observations of the HD 202628 Debris Disk

A ring-shaped debris disk around the G2V star HD 202628 (d = 24.4 pc) was imaged in scattered light at visible wavelengths using the coronagraphic mode of the Space Telescope Imaging Spectrograph on the Hubble Space Telescope. The ring is inclined by approx.64deg from face-on, based on the apparent major/minor axis ratio, with the major axis aligned along PA = 130deg. It has inner and outer radii (> 50% maximum surface brightness) of 139 AU and 193 AU in the northwest ansae and 161 AU and 223 AU in the southeast ((Delta)r/r approx. = 0.4). The maximum visible radial extent is approx. 254 AU. With a mean surface brightnesses of V approx. = 24 mag arcsec.(sup -2), this is the faintest debris disk observed to date in reflected light. The center of the ring appears offset from the star by approx.28 AU (deprojected). An ellipse fit to the inner edge has an eccentricity of 0.18 and a = 158 AU. This offset, along with the relatively sharp inner edge of the ring, suggests the influence of a planetary-mass companion. There is a strong similarity with the debris ring around Fomalhaut, though HD 202628 is a more mature star with an estimated age of about 2 Gyr. We also provide surface brightness limits for nine other stars in our study with strong Spitzer excesses around which no debris disks were detected in scattered light (HD 377, HD 7590, HD 38858, HD 45184, HD 73350, HD 135599, HD 145229, HD 187897, and HD 201219).

Krist, John E.↗