Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrument Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Mic-hackathon 2024: hackathon on machine learning for electron and scanning probe microscopy

Microscopy is one of the primary sources of information on materials structure and functionality at the nanometer and atomic scales. The data generated through microscopy is often contained in well-structured datasets, enriched with extensive metadata and sample histories, although not always with the same level of detail or storage format. The broad incorporation of data management plans by major funding agencies ensures the preservation and accessibility of this data. However, deriving insights from these rich datasets remains challenging due to the lack of established code ecosystems, standardized benchmarks, and integration strategies. Correspondingly, the efficiency of data usage is very low, and time expenditures at the analysis stage are enormous. In addition to post-acquisition data analysis, the emergence of application programming interfaces by major microscope manufacturers now creates opportunities for real-time ML-based data analytics to enable automated decision making, and particularly ML-agent controlled real-time microscope operation. Despite these opportunities, there is a significant gap in integrating the ML community with the broader microscopy community, limiting the value that these methods bring to physics and materials discovery and materials optimization. Hackathons address these challenges by fostering collaboration between ML experts and microscopy professionals, encouraging the development of innovative solutions that leverage ML for microscopy and preparing the workforce of the future both for microscopy-intensive domains areas, instrument manufacturers, and ML scientists interested in real world applications for fundamental research, materials optimization, and manufacturing. The hackathon generated benchmark datasets and digital twins of microscopes that further contribute to the development of the field and establish data analysis ecosystems. All the codes can be found at GitHub(https://github.com/KalininGroup/Mic-hackathon-2024-codes-publication/tree/1.0.0.1) and Zenodo (https://zenodo.org/records/15579940).

97 MATHEMATICS AND COMPUTING↗

An instrument combining an electrospray ionization source and a velocity-map imaging spectrometer for studying delayed electron emission of polyanions

An instrument combining an electrospray ionization source and a velocity-map imaging (VMI) spectrometer has been developed in order to study the delayed electron emission of molecular anions and especially of polyanions. It operates at a high repetition rate (kHz) in order to increase the acquisition speed. The VMI spectrometer has been upgraded for nanosecond time resolution by gating the voltages applied on the position-sensitive detector. Kinetic energy release distribution of thermionic emission (without any contribution from direct detachment) can be recorded for well-defined delays after the nanosecond laser excitation. The capability of the instrument is demonstrated by recording photodetachment spectra of the benchmark C{sub 60}{sup −} anion and C{sub 84}{sup 2−} dianion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fission Batteries: Definition, Key Attributes and Research and Development Needs

The term battery was first introduced by the American scientist and inventor Benjamin Franklin in 1749, followed by invention of the first true battery in 1800 by Alessandro Volta. Today, batteries are a ubiquitous source of portable electric power across different applications. Batteries are widely used across a range of scales from consumer products to grid-scale energy storage. There are different types of batteries, but they can be broadly classified as chemical or electric batteries [1], atomic batteries, nuclear batteries, tritium batteries or radioisotope generators [2, 3]. Atomic batteries, nuclear batteries, tritium batteries, and radioisotope generators have gained significant attention for applications requi-ing long-term power supply and high-power density, including the space power reactor [4]. While a number of reactor systems, particularly micro-reactors, are referred to as fission batteries, this paper defines key attributes required for a fission reactor to achieve capabilities comparable with the characteristics of batteries that enable their wide-spread use. Achieving this full vision of a fission battery will enable broad deployment of fission reactors that function like batteries. The research and development (R&D) activities needed to achieve the desired fission battery attributes are discussed below.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Non-visual analysis of miniaturized melt wire arrays for in-pile measurement of peak irradiation temperature

As a part of the in-pile instrumentation program, the Idaho National Laboratory (INL) has established in-house capabilities to fabricate and test new advanced manufactured printed sensors for measurement of peak temperature inside the harsh environment of a nuclear test reactor. Although nuclear test reactors may use standard methods that can provide real-time temperature information, such as thermocouples, the need for feedthroughs for real-time measurements greatly increases the cost of the experiment. Some experiments also present the problem of limited space available for instrumentation. To address this need, INL is working to improve temperature detection options for such applications. The lab is developing advanced manufactured melt wire arrays to determine peak temperatures in experiments with limited space. Furthermore, capabilities to print multiple melt wires with different melting properties on a single miniaturized unit is being established. Recent results and knowledge from this ongoing work have made it possible to develop unique temperature sensors that can accomplish user specific temperature ranges inside the harsh environments experienced during radiation testing.

36 MATERIALS SCIENCE↗

Quality appraisal of clinical practice guidelines for the management of Dysphagia after acute stroke

Objectives Dysphagia is a common complication in stroke patients, widely affecting recovery and quality of life after stroke. The objective of this systematic review is to identify the gaps that between evidence and practice by critically assessing the quality of clinical practice guidelines (CPGs) for management of dysphagia in stroke. Methods We systematically searched academic databases and guideline repositories between January 1, 2014, and August 1, 2023. The Appraisal of Guidelines for Research and Evaluation (AGREE II) instrument was used by two authors to independently assess CPG quality. Results In a total of 14 CPGs included, we identified that three CPGs obtained a final evaluation of “high quality,” nine CPGs achieved “moderate quality” and two CPGs received “low quality.” The domain of “scope and purpose” achieved the highest mean score (91.1%) and the highest median (IQR) of 91.7% (86.1, 94.4%), while the domain of “applicability” received the lowest mean score (55.8%) and the lowest median (IQR) of 55.4% (43.2, 75.5%). Conclusion The CPG development group should pay more attention to improving the methodological quality according to the AGREE II instrument, especially in the domain of “applicability” and “stakeholder involvement;” and each item should be refined as much as possible.

Gao, Shi-Lin↗

RD53A: A large-scale prototype chip for the phase II upgrade in the serially powered HL-LHC pixel detectors

The phase II upgrade of the HL-LHC experiments within the LHC intends to deepen the studies of the Higgs boson and to allow the discovery of further particles by adding an integrated luminosity of about 4000 fb -1 over 10 years of operation. This upgrade would overwhelm the installed pixel detector readout chips with higher hit rates and radiation levels than ever before. To match these extreme requirements the RD53 collaboration, a joint effort between ATLAS and CMS, developed RD53A, a new generation pixel detector readout chip prototype manufactured in a 65 nm CMOS technology. It is half the size of the final pixel chips and designed to meet requirements in the face of 3 GHz/cm 2 hit rate after irradiation to 500 Mrad. The detector is able to use 50×50 μm 2 or 25×100 μm 2 pixels with high readout speed of up to 4 links per chip with 1.28 Gbit/s each. Shunt–LDO regulators integrated on the bottom of the chip provide the required voltages to the two power domains, analog and digital. These regulators enable serial powering of the pixel modules, which is the only feasible, radiation hard scheme to ensure acceptable power cable losses and to stay within the material budget for the future pixel detectors. Finally, an overview of the status and challenges of serial powering and the Shunt–LDO regulator development will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact laser diode array based on epitaxially integrated AlGaAs/GaAs heterostructures

The main results of the development of compact laser diode mini-arrays operating under 875-nm pulsed pumping are presented and the instrumental characteristics of these arrays are studied. Specific features of these sources, in addition to a high output power (∼1.5 kW), are a narrow directional pattern (angular divergence 21° × 8°) and a small emitting area (less than 1 mm{sup 2}). The use of serially integrated AlGaAs/GaAs MOCVD heterostructures with three emitting regions to develop laser diode arrays allowed us to improve their working parameters. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SESAME and beyond

Last week, Cyprus, Egypt, Iran, Israel, Jordan, Pakistan, the Palestinian Authority, and Turkey, as well as other nations and international organizations, gathered in Jordan to inaugurate the Synchrotron-light for Experimental Science and Applications in the Middle East (SESAME) project. Having persevered through two decades of political and financial challenges, this complex machine is poised to run its first experiments this year. Indeed, SESAME represents the power of science in bringing together countries—even those with frayed relations—under a common goal of advancing knowledge for the benefit of all humankind. The triumph of SESAME, and the outpouring of research results from other light sources around the world, have spurred interest in building synchrotrons in developing countries.

47 OTHER INSTRUMENTATION↗

Low-Frequency Magnetic Field Sensor Analytics

Narrowband and broadband low frequency magnetic field sensors have applications in EMI/EMC measurements and atmospheric and space research. This report gives analytical development of such sensors.

47 OTHER INSTRUMENTATION↗

Development of INL Ultrasonic Thermometer

This document summarizes the development at Idaho National Laboratory of an ultrasonic thermometer. The ultrasonic thermometer is a temperature sensor capable of multi-point measurements at very high temperatures with a high level of radiation tolerance. All of the components of the ultrasonic thermometer have been improved over the course of this work. The base technology, a magnetosrictive transducer, has been shown to be highly radiation tolerant. The solenoidal coil used in the transducer has been redesigned to operate at higher frequencies that previously possible. Materials used for the acoustic waveguide (the sensing portion of the device) have been tested and ideal candidates identified. Finally, a solution to the sticking issue (diffusion bonding between the waveguide and a protective sheath) has been developed and tested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative Assessment of Experimental Testing of Instrument with an Embedded Digital Device Using Model-Based and Conventional Methods

The use of digital equipment has not been widespread in U.S. nuclear facilities. A major contributing factor to this situation arises from regulatory concerns about common cause failures (CCFs) stemming from the use of identical software in redundant systems, questions as to how to quantify the reliability of software-based products, validity of tools that are used for software verification and validation (V&V), and the effectiveness of software QA procedures. Compounding the concerns are sporadic incidents of digital equipment malfunctions in nuclear power plants, including lockups resulting from software memory leaks, feedwater control malfunctions due to excessive traffic on Ethernet networks, software logic errors, and other problems leading to plant trips. Additionally, the limited amount of demonstrated research and a lack of industry consensus on quantitative software reliability methodologies has hindered the widespread adoption of digital I&C in the nuclear industry. In a recent Regulatory Issue Summary (RIS), the U.S. Nuclear Regulatory Commission (NRC) identified concerns about the impact of greater use of instrumentation and control (I&C) equipment with an embedded digital device (EDD) [1]. Specifically, the NRC staff states that increased use of such devices “may increase a facility’s vulnerability to a CCF” (i.e., common-cause failure). The prevailing NRC guidance regarding software CCF (SCCF) identifies two design attributes that are acceptable for eliminating CCF concerns: (1) diversity or (2) testability (specifically, 100% testability). Either solution can result in high costs and remaining licensing uncertainty (i.e., how much diversity is enough? how to ensure test coverage of every possible sequence of device states?). Consequently, many utilities and reactor designers have limited or avoided more extensive use of digital technology to minimize licensing, scheduling, and financial risk. Without development of cost effective qualification methods to satisfy regulatory requirements and address the potential for CCF vulnerability associated with EDDs, the nuclear power industry may not be able to realize the benefits of digital technology achieved by other industries. In order to address these challenges, the U.S. Department of Energy (DOE) is sponsoring this research to assess the prospect of CCF in digital I&C equipment. The purpose of the current research is to develop an effective approach employing science-based methods to resolve concerns about CCF vulnerability that serve to inhibit deployment of advanced instrumentation (e.g., sensors, actuators, microcontrollers) with EDDs in nuclear power applications. The research objectives address the challenge of establishing high levels of safety and reliability assurance needed for the qualification of EDDs (e.g., microprocessors, programmable logic devices) that are subject to software design faults, complex failure modes, and CCF vulnerability. Specific objectives are: (1) assess the regulatory context for treatment of CCF vulnerability a graded approach to their qualification, (3) develop and extend model-based testing methods to enable effective demonstration of whether devices are subject to CCF, which may arise from vulnerabilities introduced at any stage of the design lifecycle, (4) establish a cost-effective testing framework that incorporates automation and test scenario prioritization, and (5) demonstrate the qualification approach through selection and testing of candidate digital device(s). This report documents an assessment of the results from experimental testing of a representative instrument with an embedded digital device. The experiment serves as a proof-of-concept demonstration of a model-based testing (MBT) framework. The objective of MBT is to ensure that an EDD undergoes suitably comprehensive testing to establish that it is not subject to SCCF. The approach by which MBT accomplishes this objective is through development and application of an effective test suite that provides the appropriate coverage to detect the full range of postulated faults that may arise at the requirements, design, and code (implementation) level of the EDD software. The findings of the experiment involve the application of the MBT framework by Ohio State University (OSU) through testing of the selected demonstration instrument (i.e., the prototype smart pressure sensor developed by Virginia Commonwealth University, VCU). In addition, the experiment findings also involve application of a more conventional black-box testing approach that serves as a baseline against which the MBT methodology can be compared. The primary outcome documented in this report is the comparative analysis of the capabilities demonstrated for each method. The results of the analysis demonstrate clear benefits that arise from the MBT methodology. The comparison indicates greater effectiveness from the more comprehensive evidence available through MBT and enhanced efficiency achieved through automation within the MBT framework. The structure of the report addresses the approach and application of each test method as well as the comparative analysis of the experimental results. Chapter 2 gives a summary overview of the demonstration approach. Chapter 3 covers the baseline testing and Chapter 4 documents the model-based testing. Chapter 5 describes the findings of the comparative analysis and presents the conclusions that can be drawn about the effectiveness and efficiency of the MBT methodology.

47 OTHER INSTRUMENTATION↗

Improving Lidar Turbulence Estimates for Wind Energy

Remote sensing devices (e.g., lidars) are quickly becoming a cost-effective and reliable alternative to meteorological towers for wind energy applications. Although lidars can measure mean wind speeds accurately, these devices measure different values of turbulence intensity (TI) than an instrument on a tower. In response to these issues, a lidar TI error reduction model was recently developed for commercially available lidars. The TI error model first applies physics-based corrections to the lidar measurements, then uses machine-learning techniques to further reduce errors in lidar TI estimates. The model was tested at two sites in the Southern Plains where vertically profiling lidars were collocated with meteorological towers. This presentation primarily focuses on the physics-based corrections, which include corrections for instrument noise, volume averaging, and variance contamination. As different factors affect TI under different stability conditions, the combination of physical corrections applied in L-TERRA changes depending on the atmospheric stability during each 10-minute time period. This stability-dependent version of L-TERRA performed well at both sites, reducing TI error and bringing lidar TI estimates closer to estimates from instruments on towers. However, there is still scatter evident in the lidar TI estimates, indicating that there are physics that are not being captured in the current version of L-TERRA. Two options are discussed for modeling the remainder of the TI error physics in L-TERRA: machine learning and lidar simulations. Lidar simulations appear to be a better approach, as they can help improve understanding of atmospheric effects on TI error and do not require a large training data set.

17 WIND ENERGY↗

The SuperCam Instrument Suite on the NASA Mars 2020 Rover: Body Unit and Combined System Tests

The SuperCam instrument suite provides the Mars 2020 rover, Perseverance, with a number of versatile remote-sensing techniques that can be used at long distance as well as within the robotic-arm workspace. These include laser-induced breakdown spectroscopy (LIBS), remote time-resolved Raman and luminescence spectroscopies, and visible and infrared (VISIR; separately referred to as VIS and IR) reflectance spectroscopy. A remote micro-imager (RMI) provides high-resolution color context imaging, and a microphone can be used as a stand-alone tool for environmental studies or to determine physical properties of rocks and soils from shock waves of laser-produced plasmas. SuperCam is built in three parts: The mast unit (MU), consisting of the laser, telescope, RMI, IR spectrometer, and associated electronics, is described in a companion paper. The on-board calibration targets are described in another companion paper. Here we describe SuperCam’s body unit (BU) and testing of the integrated instrument. The BU, mounted inside the rover body, receives light from the MU via a 5.8 m optical fiber. The light is split into three wavelength bands by a demultiplexer, and is routed via fiber bundles to three optical spectrometers, two of which (UV and violet; 245–340 and 385–465 nm) are crossed Czerny-Turner reflection spectrometers, nearly identical to their counterparts on ChemCam. The third is a high-efficiency transmission spectrometer containing an optical intensifier capable of gating exposures to 100 ns or longer, with variable delay times relative to the laser pulse. This spectrometer covers 535–853 nm ( $105\text{--}7070~\text{cm}^{-1}$ Raman shift relative to the 532 nm green laser beam) with $12~\text{cm}^{-1}$ full-width at half-maximum peak resolution in the Raman fingerprint region. The BU electronics boards interface with the rover and control the instrument, returning data to the rover. Thermal systems maintain a warm temperature during cruise to Mars to avoid contamination on the optics, and cool the detectors during operations on Mars.Results obtained with the integrated instrument demonstrate its capabilities for LIBS, for which a library of 332 standards was developed. Examples of Raman and VISIR spectroscopy are shown, demonstrating clear mineral identification with both techniques. Luminescence spectra demonstrate the utility of having both spectral and temporal dimensions. Finally, RMI and microphone tests on the rover demonstrate the capabilities of these subsystems as well.

47 OTHER INSTRUMENTATION↗

Instrumentation for the In-Core Real-Time Mechanical Testing of Structural Materials (INCREASE) Project

Idaho National Laboratory (INL), in collaboration with the Electric Power Research Institute (EPRI), the Nuclear Regulatory Commission (NRC), the French Atomic and Alternative Energies Commission (CEA), the Joint Research Center (JRC), the Nuclear Research and Consultancy Group (NRG), and the Research Center Rez (CVR), started a Joint Experimental Program (JEEP) project that operates within the Nuclear Energy Agency’s Framework for Irradiation Experiments (FIDES II) program in order to develop capabilities for the in-core real-time mechanical testing of structural materials. This effort will focus on designing a shared capsule capable of housing a variety of in-core mechanical testing instrumentation allowing enhanced experiments for the material science community. The outcome of the project would be high-priority, stress relaxation data for stainless-steel-based materials provided by EPRI and CEA. Stress relaxation is a major phenomenon that contributes to material degradation in nuclear reactor components. Currently, nuclear material stress relaxation is assessed both before and after irradiation, using complex and costly post-irradiation examination (PIE) activities. In-situ data would support the development of precision modeling and simulation of this degradation phenomena and would provide validation and benchmarking for existing models using the PIE data. As part of the U.S. Department of Energy Advanced Sensor and Instrumentation (ASI) program, INL has fabricated and tested out-of-core mechanical test instrumentation. This instrumentation was designed for easy adaptation to the irradiation capsule proposed under this JEEP, and can be deployed to measure real-time stress relaxation under pressurized-water reactor (PWR) conditions. This initial effort will partially serve to replace the testing capabilities lost because of shutting down the Halden Boiling Water Reactor (HBWR). The project would provide these capabilities to the international community via a shared capsule design that is easily adaptable to additional material test reactors. The design features will incorporate expansion to PWR and non-light-water reactor (LWR) environments that will be developed in future work. The capsule and instrumentation will be demonstrated in the Massachusetts Institute of Technology Reactor (MITR) for phase I and the Petten High Flux Reactor (HFR) for phase II irradiations to deliver real-time stress relaxation data on high priority stainless steel structural materials.

36 MATERIALS SCIENCE↗

An upgraded frequency-selectable laser source (FLS) calibrator for CMB bandpass characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from the uncertainty in instrument bandpass calibration. Uncertainties in bandpass can limit foreground removal and spectral fitting, which are critical for inflationary and galaxy cluster measurements. CMB experiments currently use Fourier Transform Spectrometers (FTSes) to measure instrument bandpasses. However, FTS systems are currently systematics-limited, so significant improvements in bandpass measurements require novel calibrators. To this end, we developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency coupled to a system that allows for laser power attenuation. Following initial testing with the first FLS prototype, we developed an upgraded version of the calibrator with improved performance. We present the upgrades to the FLS calibrator, the characterization of the upgraded calibrator and new laser source, and plans for testing with microwave instruments in the field.

Saunders, Lauren J. [Fermilab] (ORCID:000000016367↗

Coherent diffraction of single Rice Dwarf virus particles using hard X-rays at the Linac Coherent Light Source

Single particle diffractive imaging data from Rice Dwarf Virus (RDV) were recorded using the Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS). RDV was chosen as it is a well-characterized model system, useful for proof-of-principle experiments, system optimization and algorithm development. RDV, an icosahedral virus of about 70 nm in diameter, was aerosolized and injected into the approximately 0.1 μm diameter focused hard X-ray beam at the CXI instrument of LCLS. Diffraction patterns from RDV with signal to 5.9 Ångström were recorded. Here, the diffraction data are available through the Coherent X-ray Imaging Data Bank (CXIDB) as a resource for algorithm development, the contents of which are described here.

59 BASIC BIOLOGICAL SCIENCES↗

Secure Collaborative Environment for Seamless Sharing of Scientific Knowledge

In a secure collaborative environment, tera-bytes of data generated from powerful scientific instruments are used to train secure machine learning (ML) models on exascale computing systems, which are then securely shared with internal or external collaborators as cloud-based services. Devising such a secure platform is necessary for seamless scientific knowledge sharing without compromising individual, or institute-level, intellectual property and privacy details. By enabling new computing opportunities with sensitive data, we envision a secure collaborative environment that will play a significant role in accelerating scientific discovery. Several recent technological advancements have made it possible to realize these capabilities. In this paper, we present our efforts at ORNL toward developing a secure computation platform. We present a use case where scientific data generated from complex instruments, like those at the Spallation Neutron Source (SNS), are used to train a differential privacy enabled deep learning (DL) network on Summit, which is then hosted as a secure multi-party computation (MPC) service on ORNL’s Compute and Data Environment for Science (CADES) cloud computing platform for third-party inference. In this feasibility study, we discuss the challenges involved, elaborate on leveraged technologies, analyze relevant performance results and present the future vision of our work to establish secure collaboration capabilities within and outside of ORNL.

Yoginath, Srikanth↗

Secure environment establishment for FPGA-based safety-critical systems: quality management system context - 159

The paper discusses importance of secure development and operational environment establishment process, its particular stages, including security-oriented analysis and assessment of safety-critical instrumentation and control (I and C) systems. Two particular aspects are covered - security assessment and security assurance related to processes established by Quality Management System (QMS). One of the underlying ideas for the security assessment approach is in performance of gap analysis. Such analysis considers influence of all different factors within I and C system development process, and further application of Intrusion Modes and Effect Criticality Analysis (IMECA) technique. It makes the approach applicable to various safety-critical systems, considering underlying technologies (for example, Field-Programmable Gate Arrays (FPGA). Nowadays FPGA technology is often used in wide spectrum of hardware devices - from personal devices to complex I and C systems for Nuclear Power Plants (NPPs). The problem of cyber security assessment and assurance for FPGA technology in general and its application in safety-critical I and C systems in particular is not completely solved due to several reasons that cover regulations, QMS processes, implementation of development and verification activities, etc. The paper overviews existing regulations, which cover various aspects of NPP I and C systems development and operation, FPGA technology implementation, and secure development and operational environment establishment and assurance. The paper also emphasizes that complex approach should be used to identify and mitigate all specific vulnerabilities thorough the whole life cycle on the basis on Intrusion Modes, Effect and Criticality Analysis technique. The paper also proposes approach to the development of safety-critical I and C systems in the scope of cyber security assurance process at developer site. Secure development environment is described as a key factor during the development process and the paper also discusses establishment and maintenance of such environment as a part of company's Nuclear Quality Assurance's QMS. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗