Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instruments & Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Performance Evaluation of Clouds and the Earth’s Radiant Energy System (CERES) Instruments in Generating A Stable Earth Radiation Budget Multi-Decadal Data Record

Clouds and the Earth’s Radiant Energy System (CERES) instrument is designed to measure the earth-reflected solar and earth-emitted longwave radiances, two components of the Earth Radiation Budget. CERES instrument measure radiances in 0.3 to 5.0 micron region with Shortwave (SW) sensor, 0.3 to >100 microns with Total (TOT) sensor, and either 8 - 12 micron with Window (WN) sensor or 5 – 35 micron with longwave (LW) sensor. The on-board internal calibration module (ICM) is used to monitor the stability of the sensors and to correct the pre-launch determined sensor gains for radiance calculations. Corrections for spectral changes occurring in different wavelength regions observed through vicarious studies were applied to sensor response function used in radiance determination. The resulting global flux long term trends from each instrument have shown consistent behavior and provided a stable global record of Top of the Atmosphere (TOA) shortwave and longwave fluxes for the Earth radiation budget climate data record.

Earth Radiation Budget↗

Towards an Optimal Estimation Retrieval of Cirrus Cloud Optical and Microphysical Properties Using Hyperspectral Shortwave Instruments and A Fast Radiative Transfer Algorithm

Cirrus cloud retrieval products (here, cloud optical depth, effective particle size, and cloud top height) are important inputs into numerical weather and climate models. Uncertainties in such retrieval products, as a matter of course, propagate downstream, impacting model calculations. Improvements in high-quality global cirrus cloud optical and microphysical data products from satellite observations are needed to understand and reduce retrieval uncertainties. Hyperspectral instruments produce high-resolution and information-dense radiance spectra, thus offering the opportunity to reduce uncertainties in retrieval products. An optimal estimation-based cirrus cloud optical and microphysical product retrieval is under development for the NASA Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) and the Earth Surface Mineral Dust Source Investigation (EMIT) instruments, and the forthcoming Climate Absolute Radiance and Refractivity Observatory Pathfinder (CLARREO-Pathfinder). The spectral coverage of all three instruments includes the ultraviolet, visible, and near-infrared. In this study a very fast radiative transfer model, the Principal Component-based Radiative Transfer Model in the solar spectral region (PCRTM-Solar), is used for forward modeling computations. This will reduce the computational burden in the forward radiance and Jacobian calculations as the cost function is minimized, enabling the entire AVIRIS, EMIT, and CLARREO-Pathfinder spectral range to be used in the optimal estimation framework. Using the entire spectrum will maximize the information content, resulting in a more robust and more accurate retrieval. As a first step, the retrieval is being designed for single layer ice clouds over open ocean water. Preliminary results will be shown.

Jeffrey Mast↗

Towards an Optimal Estimation Retrieval of Cirrus Cloud Optical and Microphysical Properties Using Hyperspectral Shortwave Instruments and A Fast Radiative Transfer Algorithm

Cirrus cloud retrieval products (here, cloud optical depth, effective particle size, and cloud top height) are important inputs into numerical weather and climate models. Uncertainties in such retrieval products, as a matter of course, propagate downstream, impacting model calculations. Improvements in high-quality global cirrus cloud optical and microphysical data products from satellite observations are needed to understand and reduce retrieval uncertainties. Hyperspectral shortwave instruments produce high-resolution and information-dense spectra, thus offering the opportunity to reduce uncertainties in retrieval products. We are in the process of developing a retrieval that uses the very fast Principal Component Radiative Transfer Model in the solar spectral region (PCRTM-Solar) in the forward model calculations. This retrieval will use measured reflectances from the NASA Earth Surface Mineral Dust Source Investigation (EMIT) and the forthcoming Climate Absolute Radiance and Refractivity Observatory Pathfinder (CLARREO-Pathfinder) instruments. In this manuscript we present progress towards a reference retrieval employing a widely used, verified, accurate, yet computationally slower radiative transfer modeling technique. The reference retrieval, while too slow for using the complete hyperspectral measurement, will allow us to study the behavior of retrieval products and help us verify results from our in-development fast retrieval. Both retrievals will use the optimal estimation retrieval framework. In this manuscript we present results from an uncertainty analysis considering three uncertainty sources for a cirrus cloud retrieval in the form of error covariance matrices: reflectance uncertainty due to water vapor, the reflectance uncertainty due to ice crystal scattering assumptions, and the instrument measurement uncertainty. Results show that the uncertainty due to habit selection is the largest, while that due to water vapor is at most 0.6% relative to channel reflectance. As a first step, the retrieval is being designed for single layer ice clouds over open ocean water.

Cirrus cloud↗

Geodetic Reference Instrument Transponder for Small Satellites

The local ties between Satellite Laser Ranging stations and other collocated geodetic stations are an important component of the realization of the International Terrestrial Reference Frame but the survey accuracies are limited due to the inaccessibility of the instrument reference points. The NASA Geodetic Reference Instrument Transponder for Small Satellites (GRITSS) technology demonstration mission is designed to overcome this limitation by using a small satellite as a space-based reference point for tying together the measurement points of collocated geodetic stations. The GRITSS instrument upconverts the Global Positioning System (GPS) signals received at the satellite in real-time to S and X band and transmits them to a VLBI Global Observing System (VGOS) antenna ground station. The measurement observables do not require the satellite to be in view of more than one VLBI station at a time. The GRITSS demonstration mission utilizes a 12-UL CubeSat in a Low Earth, Sun Synchronous orbit. Tracking by the global ILRS network throughout the life of the mission is critical to establishing the space-based reference along with the precision orbit determination required by the measurement concept. Due to limitations in spacecraft power and other constraints, the initial phase of the mission will only broadcast the GRITSS VLBI signals twice a day to each of the NASA VGOS stations in Maryland, Hawaii, and Texas, but other international VGOS stations may be added during the second half of the mission. An overview of the GRITSS mission and measurement concept will be presented.

Stephen M Merkowitz↗

Observed Correlation Between Local Topography and Passive Neutron Measurements from the Dynamic Albedo of Neutrons (DAN) Instrument on the Mars Science Laboratory (MSL) Rover

The Dynamic Albedo of Neutrons (DAN) instrument on the Mars Science Laboratory Curiosity rover primarily measures neutrons that have undergone interactions with rocks and materials in the rover's local environment. As the rover ascends Aeolis Mons, it may encounter more extreme local topography (e.g., cliffs, gullies, canyons). We present three parts of the rover's traverse in which local topography, expressed as the average local relief relative to the rover, is moderately to strongly correlated with an increase in passive thermal neutron count rates. These increases in count rates are consistent with results from radiation transport models of the instrument's performance near simulated topographic features. Additional DAN measurements in areas of high average local relief (>0.25 m) within 5 m of the instrument could bolster this correlation. DAN's sensitivity to topography in its passive mode could be utilized as a new measurement capability and has implications for the operation of future landed missions carrying neutron spectrometers (e.g., VIPER, MoonRanger, Lunar-VISE).

Steven D Dibb↗

On the Characterization and Mitigation of Noise in Space-borne Microwave Sounding Instruments

Space-borne microwave sounding instruments have become vital data sources for weather prediction and climate change studies. Among the various radiometer configurations, the total power microwave radiometer is particularly appealing for current and future operational satellites due to its superior sensitivity and simple design. However, its performance is vulnerable to degradation caused by receiver gain fluctuations, electronic 1/f noise, and other time varying receiver characteristics. For Numerical Weather Prediction (NWP) users, 1/f noise introduces inter-channel correlations, complicating the assimilation of affected observations and reducing their accuracy. Addressing this noise issue in ground data processing system is essential to enhance the utility of microwave sounding data. This paper focuses on the characterization and mitigation of noise in current and future microwave sounding instruments, with particular emphasis on the impact of 1/f noise. Various methods are applied to quantitatively characterize noise features in both frequency and time domains. Additionally, the influence of calibration parameters on 1/f noise are analyzed. Based on these findings, we propose a mitigation algorithm for reducing noise during the on-orbit calibration of microwave sounding instruments, aiming to improve the quality of retrieved data for operational use.

calibration↗

Passive Tomography for Spent Fuel Verification: Analysis Framework and Instrument Design Study

The potential for gamma emission tomography (GET) to detect partial defects within a spent nuclear fuel assembly is being assessed through a collaboration of Support Programs to the International Atomic Energy Agency (IAEA). In the first phase of this study, two safeguards verification objectives have been identified. The first is the independent determination of the number of active pins that are present in the assembly, in the absence of a priori information. The second objective is to provide quantitative measures of pin-by-pin properties, e.g. activity of key isotopes or pin attributes such as cooling time and relative burnup, for the detection of anomalies and/or verification of operator-declared data. The efficacy of GET to meet these two verification objectives will be evaluated across a range of fuel types, burnups, and cooling times, and with a target interrogation time of less than 60 minutes. The evaluation of GET viability for safeguards applications is founded on a modelling and analysis framework applied to existing and emerging GET instrument designs. Monte Carlo models of different fuel types are used to produce simulated tomographer responses to large populations of “virtual” fuel assemblies. Instrument response data are processed by a variety of tomographic-reconstruction and image-processing methods, and scoring metrics specific to each of the verification objectives are defined and used to evaluate the performance of the methods. This paper will provide a description of the analysis framework and evaluation metrics, example performance-prediction results, and describe the design of a “universal” GET instrument intended to support the full range of verification scenarios envisioned by the IAEA.

spent nuclear fuel assemblies, partial defect veri↗

Cross-instrument Analysis Correlation Software

This program has been designed to assist with the tracking of a sample from one analytical instrument to another such as SEM, microscopes, micro x-ray diffraction and other instruments where particular positions/locations on the sample are examined, photographed, etc. The software is designed to easily enter the position of fiducials and locations of interest such that in a future session in the same of different instrument the positions of interest can be re-found through using the known location fiducials in the current and reference session to transform the point into the current sessions coordinate system. The software is dialog box driven guiding the user through the necessary data entry and program choices. Information is stored in a series of text based extensible markup language (XML) files.

McJunkin, Timothy R.↗

BeyondPlanck I. Global Bayesian analysis of the Planck Low Frequency Instrument data

We describe the BeyondPlanck project in terms of motivation, methodology and main products, and provide a guide to a set of companion papers that describe each result in fuller detail. Building directly on experience from ESA's Planck mission, we implement a complete end-to-end Bayesian analysis framework for the Planck Low Frequency Instrument (LFI) observations. The primary product is a joint posterior distribution P(omega|d), where omega represents the set of all free instrumental (gain, correlated noise, bandpass etc.), astrophysical (synchrotron, free-free, thermal dust emission etc.), and cosmological (CMB map, power spectrum etc.) parameters. Some notable advantages of this approach are seamless end-to-end propagation of uncertainties; accurate modeling of both astrophysical and instrumental effects in the most natural basis for each uncertain quantity; optimized computational costs with little or no need for intermediate human interaction between various analysis steps; and a complete overview of the entire analysis process within one single framework. As a practical demonstration of this framework, we focus in particular on low-l CMB polarization reconstruction, paying special attention to the LFI 44 GHz channel. We find evidence of significant residual systematic effects that are still not accounted for in the current processing, but must be addressed in future work. These include a break-down of the 1/f correlated noise model at 30 and 44 GHz, and scan-aligned stripes in the Southern Galactic hemisphere at 44 GHz. On the Northern hemisphere, however, we find that all results are consistent with the LCDM model, and we constrain the reionization optical depth to tau = 0.067 +/- 0.016, with a low-resolution chi-squared probability-to-exceed of 16%. The marginal CMB dipole amplitude is 3359.5 +/- 1.9 uK. (Abridged.)

Andersen, KJ↗

2.3.3.404 - National Lab and University Collaboration for MHK Instrumentation and Data Processing Tools

Field and laboratory validation, testing, demonstration, and operation are critical steps for increasing the technology readiness level of marine energy (ME) converters because they provide high-quality testing and performance data that are critical information used to feed all aspects of technology development. This project, in partnership with industry, enables the marine and hydrokinetic energy (MHK) community to reliably and efficiently collect, process, manage, and share quality data by facilitating access to and development of instrumentation, guidelines and data processing/QA tools. Under this project, open-source data processing code (MHKiT) and tools (ME Data Pipeline, MRE Code Hub, PRIMRE Code Catalog), instrumentation (loads measurements), data acquisition systems (miniDAQ), and measurement guidance tools (Telesto, high EMI guidance) were developed to facilitate the collection and processing of quality laboratory and field data. Overall, this project is intended to improve the quality of the data collected during laboratory and field demonstration projects by standardizing the collection and processing techniques, as well as by improving access to instrumentation, code, and measurement guidance. Quality data will, in turn, lead to improved knowledge capture following ME device testing.

data processing↗

Fiber optic instrumentation for nuclear fuels and materials irradiations

The ability to predict the safety and reliability of new and advanced nuclear fuels and materials requires high-fidelity measurements during instrumented irradiation experiments. Optical fiber-based sensors are promising candidates for instrumentation in high-temperature (300-1200 C. degrees) irradiation environments, provided that signal attenuation due to radiation damage and/or high-temperature operation is not prohibitively large. To determine the feasibility of using silica optical fibers in instrumented irradiation capsules, a computational model has been developed to predict broadband optical attenuation in fused silica fiber materials as a function of time, temperature, and dose. Defect concentrations are calculated using a set of 11 coupled differential equations that include neutron-induced displacement, radiation-induced bond cleavage at precursor sites, and thermally-assisted molecular diffusion and defect recombination at elevated temperatures. Defect concentrations are coupled with the known optical properties of the various defects in fused silica to predict optical attenuation. The effects of radiation-induced compaction (i.e., formation of the 'metamict' phase) on the optical attenuation are also included. Results show that elevated temperatures significantly reduce attenuation resulting from defect centers (attenuation below ∼750 nm) as well as attenuation resulting from radiation-induced compaction (attenuation above ∼800 nm). The predicted attenuation is acceptable for most fiber optic-based sensor systems with a dynamic range on the order of 20-50 dB for a reasonable length (1-2 meters) of fiber in the high-flux region. Many optical components use a wavelength of 850 nm, which lies in the low-attenuation window. An irradiation campaign has been initiated to provide temperature-dependent optical attenuation data at high dose to validate the predictive model. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analog neutron transport for nuclear instrumentation applications with the Monte-Carlo code TRIPOLI-4 - Paper 3

Monte-Carlo codes simulating particle transport usually make use of well-known variance reduction techniques, leading to more efficient simulations. Even in configurations which do not deal with deep-penetration, some of these techniques, such as the implicit capture, are actually often used by default. The statistical weight of the simulated particles is then modified in order to take into account the modification of the sampling without introducing any bias in the estimation process. For instance, the implicit capture decreases the statistical weight of the particles at each collision, whereas the sampling of a single outgoing particle increases this statistical weight in case of scattering reactions producing multiple neutrons. In addition, Russian roulette and splitting operations, which are usually also played at each collision, lead to other modifications of the statistical weights. As a result, Monte-Carlo codes provide particle histories that are valid on average, but collect statistical weights which differ from 1, when tallying the estimation of the quantities of interest. Yet, some nuclear instrumentation calculations inherently need to work with statistical weights equal to 1, since either individual events have to be collected (such as the arrival of a particle at a detector, the measurement of a time of flight, etc), or the coincidence of events or also correlations between individual events have to be taken into account. To address these specific applications with Monte-Carlo simulation codes, users need a full analog simulation mode. The continuous-energy Monte-Carlo code TRIPOLI4{sup R} is mainly dedicated to shielding, reactor physics and criticality safety calculations. Its capabilities have recently been extended to widen its use to nuclear instrumentation with the possibility of γ-spectrometry calculations and the simulation of photonuclear reactions for instance. Other features needed by nuclear instrumentation applications have been available in TRIPOLI-4 for a long time, such as the sampling of the time variable and the possibility of tallying in a time grid for most of the available tallies (fluxes, reaction rates, dose equivalent rates, energy depositions, etc). In TRIPOLI-4, the transport between two consecutive collisions is analog if no variance reduction technique is requested by the user to handle deep-penetration configurations. However, up to the version 9 of the code, the collision itself is sampled in a non-analog way. This paper presents a first implementation of a full analog neutron transport mode in TRIPOLI-4, preliminary verification results and an application of this functionality to the simulation of the Nucifer detector located in Saclay, France. It should be noted that only neutron transport is dealt with in this work and that all nuclear data come from JEFF-3.1.1 or ENDF/B-VII.0 evaluations, including fission data when needed. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Total Integrated Dose to Spent Fuel Pool Level Instrument Probes and Refueling Floor Personnel Dose Rates Meeting NRC Order EA-12-051 for a Typical Boiling Water Reactor - Paper 22

In reviewing the events after the March 11, 2011 Fukushima accident, the Nuclear Regulatory Commission (NRC) issued Order EA-12-051, Reference 1, requiring new reliable spent fuel pool (SFP) instrumentation for pool level determination under beyond design basis event conditions. In 2013, URS prepared a calculation for a typical Boiling Water Reactor to determine the Total Integrated Dose (TID) potentially to be imparted to radiation sensitive underwater probes (one primary and one backup) planned for meeting this Order. Additionally, URS calculated the radiological dose rates to an individual standing on the refueling floor for various SFP fill levels. NEI 12-02, Reference 2, defines the levels at which SFP condition identification is necessary as the following: Level 1 - level that is adequate to support operation of the normal fuel pool cooling system. Level 1 represents the higher of the following two points: - The level at which reliable suction loss occurs due to uncovering of the coolant inlet pipe, weir or vacuum breaker (depending on the design), or - The level at which the water height, assuming saturated conditions, above the centerline of the cooling pump suction provides the required net positive suction head specified by the pump manufacturer or engineering analysis. Level 2 - level that is adequate to provide substantial radiation shielding for a person standing on the spent fuel pool operating deck. Level 2 is based on either of the following: - 10 feet (+/- 1 foot) above the highest point of any fuel rack seated in the spent fuel pools, or - A designated level that provides adequate radiation shielding to maintain personnel radiological dose levels within acceptable limits while performing local operations in the vicinity of the pool. This level shall be based on either plant-specific or appropriate generic shielding calculations, considering the emergency conditions that may apply at the time and the scope of necessary local operations, including installation of portable SFP instrument channel components. Level 3 - level where fuel remains covered and actions to implement make-up water addition should no longer be deferred. Level 3 corresponds nominally (i.e. +/- 1 foot) to the highest point of any fuel rack seated in the spent fuel pool. The URS calculation did not define these levels or determine instrumentation setpoints. However, it determined refueling floor dose rates that could be used as a tool to determine the appropriate water depths for these levels. In determining the TID for the SFP probes and the radiological dose rates to the individual, the following radioactive sources were considered: 1. Spent Nuclear Fuel (SNF) stored in the spent fuel storage racks, 2. Local Power Range Monitors (LPRMs) stored above the top of the racks on hangers on the SFP walls 3. Radioactive material laden filters stored on platforms on top of the racks, and 4. Control Rod Blades (CRBs) stored above the top of the racks on hangers on the SFP walls. The TID for the SFP probes includes both the dose from normal operation (pool full of water) for the remaining plant life (an assumed 40 years, conservatively including an allowance for lifetime extension SFP loading) and, consistent with the NEI 12-02 guidelines, Reference 2, the assumed drop in elevation of the pool water level to the top of the spent fuel racks for a 6 hour period. The acceptable TID for the radiation-sensitive probe as defined by the manufacturer was 2x10{sup 9} rad. The individual on the pool deck was assumed to be standing on the edge of the pool with an unobstructed view of its contents, as a worst case scenario. Dose rates to this individual determined from direct shine from the same 4 sources were determined for SFP water levels varying from 1 ft above the SNF racks to 21 ft above the racks in one foot increments. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Feasibility study of a compact neutron resonance transmission analysis instrument

Neutron Resonance Transmission Analysis (NRTA) uses resonant absorption of neutrons to infer the absolute isotopic composition of a target object, enabling applications in a broad range of fields such as archaeology, enrichment analysis of nuclear fuel, and arms control treaty verification. In the past, NRTA involved large user facilities and complex detector systems. However, recent advances in the intensity of compact neutron sources have made compact neutron imaging designs increasingly feasible. This work describes the Monte Carlo (MC) based design of a compact epithermal NRTA radiographic instrument which uses a moderated, compact deuterium-tritium (DT) neutron source and an epithermal neutron detector. Such an instrument would have a wide range of applications, and would be especially impactful for such scenarios as nuclear inspection and arms control verification exercises, where system complexity and mobility may be of critical importance. The MC simulations presented in this work demonstrate accurate time-of-flight (TOF) reconstructions for transmitted neutron energies, capable of differentiating isotopic compositions of nuclear material with high levels of accuracy. A new generation of miniaturized and increasingly more intense neutron sources will allow this technique to achieve measurements with greater precision and speed, with significant impact on a variety of engineering and societal problems.

47 OTHER INSTRUMENTATION↗

TMI-2 – A Case Study for PWR Instrumentation Performance During a Severe Accident

The accident at the Three Mile Island Unit 2 (TMI-2) reactor provided a unique opportunity to evaluate sensors exposed to severe accident conditions. Conditions associated with the release of coolant and the hydrogen burn that occurred during this accident exposed instrumentation to harsh conditions, including direct radiation, radioactive contamination, and high humidity with elevated temperatures and pressures. As part of a program initiated in 2012 by the Department of Energy Office of Nuclear Energy (DOE-NE), a review was completed to gain insights from prior TMI-2 sensor survivability and data qualification efforts. This new effort focussed upon a set of sensors that provided critical data to TMI-2 operators for assessing the condition of the plant and the effects of mitigating actions taken by these operators. In addition, the effort considered sensors providing data required for subsequent accident simulations. Over 100 references related to instrumentation performance and post-accident evaluations of TMI-2 sensors and measurements were reviewed. Insights gained from this review are summarized within this report. For each sensor, a description is provided with the measured data and conclusions related to the sensor’s survivability, and the basis for conclusions about its survivability. As noted within this document, several techniques were invoked in the TMI-2 post-accident evaluation program to assess sensor status, including comparisons with data from other sensors, analytical calculations, laboratory testing, and comparisons with sensors subjected to similar conditions in large-scale integral tests and with sensors that were similar in design but more easily removed from the TMI-2 plant for evaluations. Conclusions from this review provide important insights related to sensor survivability and enhancement options for improving sensor performance. In addition, this document provides recommendations related to the sensor survivability and data evaluation process that could be implemented in upcoming Fukushima Daiichi recovery efforts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TMI-2 - A Case Study for PWR Instrumentation Performance during a Severe Accident

The accident at the Three Mile Island Unit 2 (TMI-2) reactor provided a unique opportunity to evaluate sensors exposed to severe accident conditions. Conditions associated with the release of coolant and the hydrogen burn that occurred during this accident exposed instrumentation to harsh conditions, including direct radiation, radioactive contamination, and high humidity with elevated temperatures and pressures. As part of a program initiated in 2012 by the Department of Energy Office of Nuclear Energy (DOE-NE), a review was completed to gain insights from prior TMI-2 sensor survivability and data qualification efforts. This new effort focused upon a set of sensors that provided critical data to TMI-2 operators for assessing the condition of the plant and the effects of mitigating actions taken by these operators. In addition, the effort considered sensors providing data required for subsequent accident simulations. Over 100 references related to instrumentation performance and post-accident evaluations of TMI-2 sensors and measurements were reviewed. Insights gained from this review are summarized within this report. For each sensor, a description is provided with the measured data and conclusions related to the sensor’s survivability, and the basis for conclusions about its survivability. As noted within this document, several techniques were invoked in the TMI-2 post-accident evaluation program to assess sensor status, including comparisons with data from other sensors, analytical calculations, laboratory testing, and comparisons with sensors subjected to similar conditions in large-scale integral tests and with sensors that were similar in design but more easily removed from the TMI-2 plant for evaluations. Conclusions from this review provide important insights related to sensor survivability and enhancement options for improving sensor performance. In addition, this document provides recommendations related to the sensor survivability and data evaluation process that could be implemented in upcoming Fukushima Daiichi recovery efforts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrumentation for Monitoring around Marine Renewable Energy Converters: Workshop Final Report

To better understand the state of instrumentation and capabilities for monitoring around marine energy converters, the U.S. Department of Energy directed Pacific Northwest National Laboratory and the Northwest National Marine Renewable Energy Center at the University of Washington to convene an invitation-only workshop of experts from around the world to address instrumentation needs.

16 TIDAL AND WAVE POWER↗

In-Pile Instrumentation Multi- Parameter System Utilizing Photonic Fibers and Nanovision

An advanced in-pile multi-parameter reactor monitoring system is being proposed in this funding opportunity. The proposed effort brings cutting edge, high fidelity optical measurement systems into the reactor environment in an unprecedented fashion, including in-core, in-cladding and in-fuel pellet itself. Unlike instrumented leads, the proposed system provides a unique solution to a multi-parameter monitoring need in core while being minimally intrusive in the reactor core. Detector designs proposed herein can monitor fuel compression and expansion in both the radial and axial dimensions as well as monitor linear power profiles and fission rates during the operation of the reactor. In addition to pressure, stress, strain, compression, neutron flux, neutron spectra, and temperature can be observed inside the fuel bundle and fuel rod using the proposed system. The proposed research aims at developing radiation-hard, harsh-environment multi-parameter systems for insertion into the reactor environment. The proposed research holds the potential to drastically increase the fidelity and precision of in-core instrumentation with little or no impact in the neutron economy in the reactor environment while providing a measurement system capable of operation for entire operating cycles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗