Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inverter Controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Electrical Manipulation of Topological Phases in a Quantum Anomalous Hall Insulator

Quantum anomalous Hall phases arising from the inverted band topology in magnetically doped topological insulators have emerged as an important subject of research for quantization at zero magnetic fields. Though necessary for practical implementation, sophisticated electrical control of molecular beam epitaxy (MBE)-grown quantum anomalous Hall matter have been stymied by growth and fabrication challenges. Here, in this study, a novel procedure is demonstrated, employing a combination of thin-film deposition and 2D material stacking techniques, to create dual-gated devices of the MBE-grown quantum anomalous Hall insulator, Cr-doped (Bi,Sb) 2 Te 3 . In these devices, orthogonal control over the field-induced charge density and the electric displacement field is demonstrated. A thorough examination of material responses to tuning along each control axis is presented, realizing magnetic property control along the former and a novel capability to manipulate the surface exchange gap along the latter. Through electrically addressing the exchange gap, the capabilities to either strengthen the quantum anomalous Hall state or suppress it entirely and drive a topological phase transition to a trivial state are demonstrated. The experimental result is explained using first principle theoretical calculations, and establishes a practical route for in situ control of quantum anomalous Hall states and topology.

36 MATERIALS SCIENCE↗

Supplementary Investigation in the Langley Free-Spinning Tunnel of a 1/20-Scale Model of the Douglas XF4D-1 Airplane Including Spin-Recovery Parachute Tests of the Model Loaded to Simulate the Douglas F5D-1 Airplane

A supplementary investigation has been conducted in the Langley 20-foot free-spinning tunnel of a l/20-scale model of the Douglas XF4D-1 airplane to determine the effect of only neutralizing the rudder for recovery from an inverted spin, and the effect of partial aileron deflection with the spin for recovery from an erect spin. An estimation of the size parachute required for satisfactory recovery from a spin with the model ballasted to represent the Douglas F5D-1 (formerly the Douglas XF4D-2) airplane was also made. Results of the original investigation on the XF4D-1 design are presented in NACA RM SL50K30a. The results indicated that satisfactory recoveries from inverted spins of the airplane should be obtained by rudder neutralization when the longitudinal stick position is neutral or forward. Recoveries from erect spins from the normal-spin control configuration should be satisfactory by full rudder reversal with simultaneous movement of the ailerons to two-thirds with the spin. For the parachute tests with the model loaded to represent the F5D-1 airplane, the tests indicated that a 16.7-foot-diameter hemispherical-tail parachute (drag coefficient of 1.082 based on the projected area) with a towline 20.0 feet long (full- scale values) should be satisfactory for an emergency spin-recovery device during demonstration spins of the airplane.

Klinar, Walter J.↗

Commissioning of the new AGS MMPS transformers

The Brookhaven AGS Main Magnet Power Supply (MMPS) is a thyristor control supply rated at 5500 Amps. +/-9000 Volts. The peak magnet power is 50 MWatts. The power supply is fed from a motor/generator manufactured by Siemens. During rectify and invert operation the P Bank power supplies are used. During the flattops the F Bank power supplies are used. The P Bank power supplies are fed from two 23 MVA transformers and the F Bank power supplies are fed from two 5.3 MYA transformers. The fundamental frequency of the F Bank power supplies is 1440 Hz, however the fundamental frequency of the P banks was 720 Hz. It was very important to reduce the ripple during rectify to improve polarized proton operations. For this reason and also because the original transformers were 45 years old we replaced these transformers with new ones and we made the fundamental frequency of both P and F banks 1440 Hz. This paper will highlight the major hurdles that were involved during the installation of the new transformers. It will present waveforms while running at different power levels up to 6MW full load. It will show the transition from the F-Bank power supplies to the P-Banks and also show the improvements in ripple made on the P-Bank power supplies.

43 PARTICLE ACCELERATORS↗

Distribution Feeder-Scale Fast Frequency Response via Optimal Coordination of Net-load Resources Part II: Large-Scale Demonstration

This work is the second of a two-part series in which we develop and experimentally demonstrate a hierarchical control solution for optimally coordinating thousands of deferrable loads and distributed energy resources (DERs) to provide fast frequency response (FFR) from an entire distribution feeder. In Part I, we developed and proved practical algorithms for fast, cost-based optimal dispatch and for determining the optimal amount of headroom to operate solar inverters with to support FFR dispatch while minimizing opportunity cost. Simulation results in Part I demonstrated the advantages of the hierarchical dispatch approach in being able to maintain fast solution times needed for FFR even when the problem size increases. In Part II, we implement the algorithms developed in Part I in a novel, large-scale power hardware-in-the-loop experiment including embedded controllers and more than 100 powered appliance loads and DER connected to a simulated real-world distribution system with more than 10,000 controlled devices. Experimental results from multiple scenarios confirm that the optimal FFR dispatch approach scales well and can optimally coordinate more than 10,000 net-load resources across a distribution network while achieving hardware response times within 500 ms, which is not possible using state-of-the-art optimal coordination approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Solar-assisted Voltage Optimization Method for Transmission Solar Network Power System

This paper proposes a new formulation and solution algorithm that uses transmission level solar inverters to address the security-constrained optimal power flow (SCOPF) problem. The goal is to stabilize voltage fluctuations in transmission networks in base case and contingency scenarios, by using bulk solar power plant with a minimal number of post-contingency corrections. To achieve this goal, a two-stage volt/var optimization method is proposed to first correct all voltage violations with the volt-var alternating current optimal power flow (ACOPF) algorithm for a base case. Then a linearized SCOPF volt-var control algorithm is proposed to identify the corrective actions for all potential voltage violations in all contingency scenarios. The proposed method was tested and validated on a modified IEEE 118-bus system with solar photovoltaic (PV) data.

Photovoltaic, Volt/Var Control↗

Role of Inverter-Based Resources (IBRs) in Energizing Remote Generating Stations

The increasing integration of Inverter-Based Resources (IBRs) into the system has brought significant focus on their role in blackstart and restoration procedures. Their advantageous features, such as low startup power requirements, operational flexibility across a wide range of power factors, rapid controllability, and the ability to energize a network at lower voltage levels necessitate a reassessment of existing restoration protocols. This paper seeks to showcase how IBRs can utilize their grid-forming capabilities to provide power to a remote generating station through detailed EMT simulation studies using data collected from an existing portion of a network.

blackstart procedure↗

Investigation Of Prandtl-Ishlinskii Hysteresis Compensation for Deep Space Optical Communications Pointing Control

This paper studies the simulated performance of the Deep Space Optical Communication (DSOC) laser downlink pointing control system that has a pointing requirement at the sub-microradian scale. To achieve the required pointing precision, the DSOC Flight Laser Transceiver (FLT) point-ahead mirror (PAM) employs piezoelectric actuators, which are widely used in precision applications due to their high motion resolution, rapid response, and high output forces. However, a piezoelectric actuator's performance is often limited by nonlinearities in their response, most significantly hysteresis. To study the effect of hysteresis on our simulated pointing performance, an invertible hysteresis model is developed using the Classical Prantdl-Ishlinskii (CPI) method. The simulation includes models of DSOC hardware and electronic system components based on key parameters (bias, frequency response, noise), with the hysteresis modeled in the PAM piezo actuator dynamics. A Proportional-Integral controller provides feedback with measurements from two potential sources: strain gauge sensors or a photon-counting camera. To compensate for hysteresis behavior, a feedforward inverse CPI hysteresis model is implemented in the control system. Two CPI models are built using different sampling methods (uniform sampling and cosine spacing) and controller performance is compared. For the maximum command range of ±400 μrad at 1 mHz, results show that the feedforward combined with feedback control reduces output tracking error by 50% or 58% (to 0.20 or 0.38 μrad) compared to feedback control alone (from 0.40 or 0.90 μrad), corresponding to the uniform-sampled and cosine-sampled CPI models, respectively.

Marinello, Lindsey A.↗

Advanced Accessory Power Supply Topologies

This Cooperative Research and Development Agreement (CRADA) began December 8, 2000 and ended September 30, 2009. The total funding provided by the Participant (General Motors Advanced Technology Vehicles [GM]) during the course of the CRADA totaled $1.2M enabling the Contractor (UT-Battelle, LLC [Oak Ridge National Laboratory, a.k.a. ORNL]) to contribute significantly to the joint project. The initial task was to work with GM on the feasibility of developing their conceptual approach of modifying major components of the existing traction inverter/drive to develop low cost, robust, accessory power. Two alternate methods for implementation were suggested by ORNL and both were proven successful through simulations and then extensive testing of prototypes designed and fabricated during the project. This validated the GM overall concept. Moreover, three joint U.S. patents were issued and subsequently licensed by GM. After successfully fulfilling the initial objective, the direction and duration of the CRADA was modified and GM provided funding for two additional tasks. The first new task was to provide the basic development for implementing a cascaded inverter technology into hybrid vehicles (including plug-in hybrid, fuel cell, and electric). The second new task was to continue the basic development for implementing inverter and converter topologies and new technology assessments for hybrid vehicle applications. Additionally, this task was to address the use of high temperature components in drive systems. Under this CRADA, ORNL conducted further research based on GM’s idea of using the motor magnetic core and windings to produce bidirectional accessory power supply that is nongalvanically coupled to the terminals of the high voltage dc-link battery of hybrid vehicles. In order not to interfere with the motor’s torque, ORNL suggested to use the zero-sequence, highfrequency harmonics carried by the main fundamental motor current for producing the accessory power. Two studies were conducted at ORNL. One was to put an additional winding in the motor slots to magnetically link with the high frequency of the controllable zero-sequence stator currents that do not produce any zero-sequence harmonic torques. The second approach was to utilize the corners of the square stator punching for the high-frequency transformers of the dc/dc inverter. Both approaches were successful. This CRADA validated the feasibility of GM’s desire to use the motor’s magnetic core and windings to produce bidirectional accessory power supply. Three joint U.S. patents with GM were issued to ORNL and GM by the U.S. Patent Office for the research results produced by this CRADA.

30 DIRECT ENERGY CONVERSION↗

A Modular Multilevel Converter with Power Mismatch Control for Grid-Connected Photovoltaic Systems

A modular multilevel power converter configuration for grid connected photovoltaic (PV) systems is proposed. The converter configuration replaces the conventional bulky line frequency transformer with several high frequency transformers, potentially reducing the balance of systems cost of PV systems. The front-end converter for each port is a neutral-point diode clamped (NPC) multi-level dc-dc dual-active bridge (ML-DAB) which allows maximum power point tracking (MPPT). The integrated high frequency transformer provides the galvanic isolation between the PV and grid side and also steps up the low dc voltage from PV source. Following the ML-DAB stage, in each port, is a NPC inverter. N number of NPC inverters’ outputs are cascaded to attain the per-phase line-to-neutral voltage to connect directly to the distribution grid (i.e., 13.8 kV). The cascaded NPC (CNPC) inverters have the inherent advantage of using lower rated devices, smaller filters and low total harmonic distortion required for PV grid interconnection. The proposed converter system is modular, scalable, and serviceable with zero downtime with lower foot print and lower overall cost. A novel voltage balance control at each module based on power mismatch among N-ports, have been presented and verified in simulation. Analysis and simulation results are presented for the N-port converter. The converter performance has also been verified on a hardware prototype.

14 SOLAR ENERGY↗

Power Hardware-in-the-Loop Interfaces for Inverter-Based Microgrid Experiments Including Transitions: Preprint

Microgrids continue to proliferate, particularly those that rely on inverter-based resources as the microgrid's voltage and frequency leader. Hardware-in-the-loop (HIL) simulations can de-risk microgrid deployments, and therefore we need power-hardware-in-the-loop (PHIL) interfaces for grid-forming (GFM) inverters to enable simulations of seamless transitions between islanded and grid-connected operation. Such microgrid interfaces are particularly challenging to model when the inverters need to switch modes, i.e., between grid-following (GFL) and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents two PHIL interfaces for such microgrids and the preliminary experimental results: One interface is suitable for those who have access to a power amplifier that can operate as a controllable current source, and the other is for those who need a solution that uses a voltage-mode power amplifier.

battery energy storage system↗

A hybrid architecture for volt-var control in active distribution grids

Modern active distribution grids are characterized by the increasing penetration of distributed energy resources (DERs). The proper coordination and scheduling of a large numbers of these small-scale and spatially distributed DERs is necessary, and warrants the use of novel distributed approaches. In this paper, we propose a hybrid volt-var control architecture for the distribution grid, which leverages existing centralized and local approaches to planning, decision making, and control, and augments it with distributed optimization and distributed control for DER management. First, we propose a convex model to describe the power physics of distribution grids of meshed topology and unbalanced structure, based on current injection and McCormick Envelopes. Second, we employ the distributed proximal atomic coordination (PAC) algorithm to coordinate DERs to provide voltage support. We implement volt-var optimization by optimally coordinating DERs including PV smart inverters and demand response. We present results using the IEEE-34 bus network, using real data from a distribution feeder in Hawaii, to model load and PV generation. Different levels of DER penetration and objective functions are simulated. Finally, our results show the need for the coordination of DERs to improve voltage profiles, even in networks with existing voltage control devices. Further, we show the need for flexible reactive power capabilities to achieve desired grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BIL GRID-READY WIND: Reliable and Economical Grid Services Design, Implementation, and Demonstration at the Great Pathfinder Wind Power Plant

The GRID-READY WIND project aimed to demonstrate the ability of utility-scale wind power plants (WPPs) to deliver traditional and emerging grid services (GSs) in both grid-following (GFL) and grid-forming (GFM) modes through a centralized control framework, supplemented by local control adjustments at the wind turbine generator as needed. Throughout the project, the team offered recommendations on how the grid services demonstrated with WPPs could be applied to other inverter-based resources (IBRs), such as photovoltaic (PV) systems and battery energy storage systems (BESS), while considering the unique dynamics of these resources arising from their energy generation characteristics. The project sought to enhance the confidence of system operators (SOs) and planners in utilizing WPPs, alongside other IBRs such as PV plants and BESS, to provide essential grid services over extended periods under diverse operating conditions, thereby supporting their integration into the bulk power system.

17 WIND ENERGY↗

Steady-state and dynamic characteristics of a 20-kHz spacecraft power system - Control of harmonic resonance

A detailed computer simulation was used to illustrate the steady-state and dynamic operating characteristics of a 20-kHz resonant spacecraft power system. The simulated system consists of a parallel-connected set of DC-inductor resonant inverters (drivers), a 440-V cable, a node transformer, a 220-V cable, and a transformer-rectifier-filter (TRF) AC-to-DC receiver load. Also included in the system are a 1-kW 0.8-pf RL load and a double-LC filter connected at the receiving end of the 20-kHz AC system. The detailed computer simulation was used to illustrate the normal steady-state operating characteristics and the dynamic system performance following, for example, TRF startup. It is shown that without any filtering the given system exhibits harmonic resonances due to an interaction between the switching of the source and/or load converters and the AC system. However, the double-LC filter at the receiving-end of the AC system and harmonic traps connected in series with each of the drivers significantly reduce the harmonic distortion of the 20-kHz bus voltage. Significant additional improvement in the waveform quality can be achieved by including a double-LC filter with each driver.

Wasynczuk, O.↗

Water and vapor transport in algal‐fungal lichen: Modeling constrained by laboratory experiments, an application for Flavoparmelia caperata

ABSTRACT Algal‐fungal symbionts share water, nutrients, and gases via an architecture unique to lichens. Because lichen activity is controlled by moisture dynamics, understanding water transport is prerequisite to understand their fundamental biology. We propose a model of water distributions within foliose lichens governed by laws of fluid motion. Our model differentiates between water stored in symbionts, on extracellular surfaces, and in distinct morphological layers. We parameterize our model with hydraulic properties inverted from laboratory measurements of Flavoparmelia caperata and validate for wetting and drying. We ask: (1) Where is the bottleneck to water transport? (2) How do hydration and dehydration dynamics differ? and (3) What causes these differences? Resistance to vapor flow is concentrated at thallus surfaces and acts as the bottleneck for equilibrium, while internal resistances are small. The model captures hysteresis in hydration and desiccation, which are shown to be controlled by nonlinearities in hydraulic capacitance. Muting existing nonlinearities slowed drying and accelerated wetting, while exaggerating nonlinearities accelerated drying and slowed wetting. The hydraulic nonlinearity of F. caperata is considerable, which may reflect its preference for humid and stable environments. The model establishes the physical foundation for future investigations of transport of water, gas, and sugar between symbionts.

Potkay, Aaron↗

Stability Analysis and Control of a Rotary Transformer-Based Synchronous Motor Field Excitation System

This paper analyses the stability and control of a rotary transformer-based field excitation system. Rotary transformers enable wireless and contactless power transfer to rotating components of a system such as the rotor of a wound field synchronous motor. Their use in the field excitation of synchronous motor for electric vehicle and similar applications overcomes the disadvantages associated with the traditional slip rings-brushes arrangement such as frequent maintenance requirement, significant friction losses at high speed, contact cooling issues, increased overall motor weight and size and reduced reliability and life. The rotary transformer studied in this paper is series-series compensated with the transmitter coil supplied from a single-phase inverter, and the receiver coil connected to a full bridge diode rectifier that feeds the rotor field winding. Harmonic balance technique is used to obtain a complex variable dynamic model of the system. Using this model and the concept of the bimatrix, the controllability and observability of the rotary transformer is analyzed for different output variables. The controllability and observability matrices are not of full rank indicating the existence of states which are unaffected by the control input. The concept of zero dynamics of the system is used to determine these states and the condition for the stability of the zero dynamics is determined.

Haruna, Josiah↗

Magnetic field control of the neutral and charged exciton fine structure in single quantum dashes emitting at 1.55 μm

We investigated the neutral and charged exciton fine structure in single InAs/InGaAlAs/InP quantum dashes emitting at 1.55 μm using polarization-resolved microphotoluminescence in a magnetic field. Inverted spin configuration of horizontally [1–10] and vertically [110] polarized transitions has been observed. An in-plane magnetic field of up to 5 Tesla has been applied to tailor the fine structure, and eventually to reduce the splitting of the bright exciton states down to zero. This inverted structure has been observed for all the investigated excitons, making it a characteristic feature for this class of nanostructures with the largest splitting reduction of 170 μeV.

36 MATERIALS SCIENCE↗

Distonic radical anion species in cysteine oxidation processes

Oxidation of cysteine residues constitutes an important regulatory mechanism in the function of biological systems. Much of this behavior is controlled by the specific chemical properties of the thiol side-chain group, where reac-tions with reactive oxygen species take place. Herein, we in-vestigated the entire cysteine oxidation cycle Cys-SH ? Cys-SOnH (n = 1, 2, 3) using cryogenic negative ion photoelectron spectroscopy and quantum-chemical calculations. The conven-tional view on the first reversible oxidation step (n = 1) is as-sociated with sulfinate species. Yet our results indicate that an alternative option exists in the form of novel distonic radical anion •OS-CH2CH(NH2)-COO- with an unpaired electron on the thiol group and excess negative charge on the carboxylate. Higher order oxidation states (n = 2, 3) are thought to be asso-ciated with irreversible oxidative damage, and our results show that excess negative charge in those cases migrates to -SOn- group. Furthermore, these species are stable towards 1e oxidation, as opposed to the n = 1 case that undergoes intra-molecular proton transfer. The molecular level insights report-ed in this work provide direct spectroscopic evidences towards unique chemical versatility of Cys-sulfenic acid (Cys-SOH) in post-translational modifications of protein systems. This research was supported by the U.S. Department of Energy (DOE), Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences and Biosciences (X.-B. W. and M. V.) and was performed at the EMSL, a national scientific user facility sponsored by DOE's Office of Biological and Environmental Research and located at the Pacific Northwest National Laboratory. Z. B. Q. acknowledges additional support from the National Natural Science Foundation of China (Grant No. 21873003 and 21503003) and the Special Program for Applied Research on Super Computation of the NSFC-Guangdong Joint Fund (the second phase) (Grant No. U1501501) and Super Computation of Shenzhen.

Qin, Zhengbo↗