Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear Technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

High resolution x-ray Thomson scattering measurements from cryogenic hydrogen jets using the linac coherent light source

We present the first spectrally resolved measurements of x-rays scattered from cryogenic hydrogen jets in the single photon counting limit. The 120 Hz capabilities of the LCLS, together with a novel hydrogen jet design [J. B. Kim et al., Rev. Sci. Instrum. (these proceedings)], allow for the ability to record a near background free spectrum. Such high-dynamic-range x-ray scattering measurements enable a platform to study ultra-fast, laser-driven, heating dynamics of hydrogen plasmas. This measurement has been achieved using two highly annealed pyrolytic graphite crystal spectrometers to spectrally resolve 5.5 keV x-rays elastically and inelastically scattered from cryogenic hydrogen and focused on Cornell-SLAC pixel array detectors [S. Herrmann et al., Nucl. Instrum. Methods Phys. Res., Sect. A 718, 550 (2013)].

43 PARTICLE ACCELERATORS↗

DESC: A stellarator equilibrium solver

In this paper, the new code DESC is presented to solve for fixed-boundary ideal magnetohydrodynamic equilibria in stellarators. The approach directly solves the equilibrium force balance as a system of nonlinear equations in the form f(x) = 0. The independent variables x represent nested magnetic flux surfaces expressed in the inverse representation with toroidal flux coordinates, and the equations f(x) quantify equilibrium force balance errors at discrete points in real space. Discretizing with global Fourier–Zernike basis functions properly treats the magnetic axis and minimizes the number of coefficients needed to describe the flux surfaces. The pseudospectral method provides great flexibility in where the errors are evaluated, and the system of equations is efficiently solved with a Newton–Raphson iteration. Equilibria are computed and compared against VMEC for both axisymmetric and non-axisymmetric examples. The results show fast convergence rates and solutions with low errors throughout the plasma volume.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The science case for an intermediate energy advanced and novel accelerator linear collider facility

It is widely accepted that the next lepton collider beyond a Higgs factory would require center-of-mass energy of the order of up to 15 TeV. Since, given reasonable space and cost restrictions, conventional accelerator technology reaches its limits near this energy, high-gradient advanced acceleration concepts are attractive. Advanced and novel accelerators (ANAs) are leading candidates due to their ability to produce acceleration gradients on the order of 1–100 GV/m, leading to compact acceleration facilities. However, intermediate energy facilities (IEF) are required to test the critical technology elements on the way towards multi-TeV-class colliders. Here a science case for a 20–100 GeV center-of-mass energy ANA-based lepton collider that can be a candidate for an intermediate energy facility is presented. The IEF can provide numerous opportunities for high energy physics studies including precision Quantum Chromodynamics and Beyond the Standard Model physics measurements, investigation of charged particle interactions with extreme electromagnetic fields, and exploring muon and proton beam acceleration. Possible applications of this collider include the studies of γγ and electron beam-fixed target/beamdump collider designs. Thus, the goal of the proposed IEF is to both carry out particle physics measurements in the 20-100 GeV ranges as well as to serve as an ANA demonstrator facility.

43 PARTICLE ACCELERATORS↗

Endocervical ultrasound applicator for integrated hyperthermia and HDR brachytherapy in the treatment of locally advanced cervical carcinoma

Purpose: The clinical success of hyperthermia adjunct to radiotherapy depends on adequate temperature elevation in the tumor with minimal temperature rise in organs at risk. Existing technologies for thermal treatment of the cervix have limited spatial control or rapid energy falloff. The objective of this work is to develop an endocervical applicator using a linear array of multisectored tubular ultrasound transducers to provide 3-D conformal, locally targeted hyperthermia concomitant to radiotherapy in the uterine cervix. The catheter-based device is integrated within a HDR brachytherapy applicator to facilitate sequential and potentially simultaneous heat and radiation delivery. Methods: Treatment planning images from 35 patients who underwent HDR brachytherapy for locally advanced cervical cancer were inspected to assess the dimensions of radiation clinical target volumes (CTVs) and gross tumor volumes (GTVs) surrounding the cervix and the proximity of organs at risk. Biothermal simulation was used to identify applicator and catheter material parameters to adequately heat the cervix with minimal thermal dose accumulation in nontargeted structures. A family of ultrasound applicators was fabricated with two to three tubular transducers operating at 6.6-7.4 MHz that are unsectored (360 deg.), bisectored (2x180 deg.), or trisectored (3x120 deg.) for control of energy deposition in angle and along the device length in order to satisfy anatomical constraints. The device is housed in a 6 mm diameter PET catheter with cooling water flow for endocervical implantation. Devices were characterized by measuring acoustic efficiencies, rotational acoustic intensity distributions, and rotational temperature distributions in phantom. Results: The CTV in HDR brachytherapy plans extends 20.5{+-}5.0 mm from the endocervical tandem with the rectum and bladder typically <8 mm from the target boundary. The GTV extends 19.4{+-}7.3 mm from the tandem. Simulations indicate that for 60 min treatments the applicator can heat to 41 deg. C and deliver >5EM{sub 43 Degree-Sign C} over 4-5 cm diameter with T{sub max}<45 deg. C and 1 kg m{sup -3} s{sup -1} blood perfusion. The 41 deg. C contour diameter is reduced to 3-4 cm at 3 kg m{sup -3} s{sup -1} perfusion. Differential power control to transducer elements and sectors demonstrates tailoring of heating along the device length and in angle. Sector cuts are associated with a 14-47 deg. acoustic dead zone, depending on cut width, resulting in a {approx}2-4 deg. C temperature reduction within the dead zone below T{sub max}. Dead zones can be oriented for thermal protection of the rectum and bladder. Fabricated devices have acoustic efficiencies of 33.4%-51.8% with acoustic output that is well collimated in length, reflects the sectoring strategy, and is strongly correlated with temperature distributions. Conclusions: A catheter-based ultrasound applicator was developed for endocervical implantation with locally targeted, 3-D conformal thermal delivery to the uterine cervix. Feasibility of heating clinically relevant target volumes was demonstrated with power control along the device length and in angle to treat the cervix with minimal thermal dose delivery to the rectum and bladder.

60 APPLIED LIFE SCIENCES↗

On the Nonlinear Dynamics and Quasi-Statics of Tape Joined Structures

Tape joints have been a key tool in assembly of nuclear weapons for almost 40 years. In that time sufficient experience has been gained to have confidence on the robustness of this technology within established design constraints; the structural dynamics of systems assembled by tape joints are much less well understood. Though there is lore that tape joined structures behave linearly in the axial direction, even that is contradicted by the literature, where such structures are found to be bi-linear (nonlinear) in axial modes. Experimental results presented here show much more significant nonlinearity when such systems vibrate in such a way that there is bending across the joint cross-section. In addition, it will be difficult to understand the nonlinear structural dynamics before the pre-loads on the tape joints is known. Therefore, a strategy to deduce the joint pre-loads from surface strain measurements has been developed. This technique exploits finite element analysis to generate an approximate Green’s function to map tape loads to surface strain and employs numerical optimization to solve an inverse problem. This technique is demonstrated on the same test specimen employed in the dynamics experiments.

Segalman, Daniel Joseph↗

Beam Diagnostics Report for the Thermal Test Conducted on 3/9/2016

The thermal test OTR data revealed several issues with the beam focus and the target window itself. The oxidation of the target window and the prominence of a scratch across the center of the window makes it impossible to accurately measure the beam profile and size.

43 PARTICLE ACCELERATORS↗

Advanced Materials and Technologies for Resilient Infrastructure Systems

Infrastructure is largely unnoticed until it breaks down and services fail. This includes water supplies, gas pipelines, bridges and highways, phone lines and cell towers, and the electric grid — all of the complex systems that keep our societies and economies running. The secure and reliable functioning of our nation’s critical infrastructure is required; however, U.S. infrastructures face a rising frequency and severity of natural disasters (Figure 1), and a growing number and sophistication of physical and cyber attacks. With increasing technological and economic progress, infrastructures are growing more interconnected, necessitating new considerations for their security. Recent disasters such as Superstorm Sandy provide profound insights into how non-linear interactions combine with network effects to trigger a cascade of events across interdependent systems.

36 MATERIALS SCIENCE↗

50 MW Segmented Ultralight Morphing Rotors for Wind Energy

A multi-institutional team designed a 50 Megawatt (MW) rated wind turbine featuring downwind aeroelastic morphing to reduce blade loads and allow an ultralight segmented rotor (mass reduction of about 25% compared to a conventional upwind rotor). The team used a control co-design approach with state-of-the art simulations including for the rotor and tower design using non-linear fluid-structure interactions and control algorithms, and the team also designed, built, and field-tested an aeroelastically-scaled downwind rotor to demonstrate this novel technology and validate the design tool fidelity. In a follow-on phase, these results were used along with an updated Levelized Cost Of Energy (LCOE) methodology to co-design a more detailed set of 25 MW rated turbine designs (including individual pitch control) based on minimum LCOE with highly flexible blades for an Atlantic Ocean offshore fixed-bottom design targeted towards market technology evaluation. A set of upwind and downwind designs at 25 MW rated scales were found to provide the best LCOE, with strong improvements over all previous offshore reference turbines (NREL 5MW, DTU 10 MW and IEA 15 MW). The optimized design would represent the world’s largest offshore turbine design, which combines several state-of-the-art structural, aerodynamic, and control technologies into a new and optimized system concept.

17 WIND ENERGY↗

RF Frontiers for Particle Physics, the US View

In this talk I provide an update on the RF research for future colliders in the U.S., through the prism of Snowmass and P5 report. During Snowmass, we considered various applications of RF technology to the proposed future colliders and other accelerator- and non-accelerator-based experiments. P5 narrowed down the choices of future machines. The colliders include circular and linear $e^+ e^-$ Higgs factories, and longer-term options such as muon and hadron high energy colliders. I will start with Snowmass and P5 recommendations. As it is impossible to cover all possible RF R&D topics, I will discuss only three critical topics relevant to future colliders: efficiency of RF power sources, cold normal conducting RF, and cavities for ionization channel of muon collider. Progress on SRF accelerating cavities for future colliders will be covered in a separate talk. The choice of topics reflects my preference and in some cases ignorance, which I think is inevitable when one tries to cover such a broad subject.

43 PARTICLE ACCELERATORS↗

LDRD23-0730: Invoking Multilayer Networks to Develop a Paradigm for Security Science—Summary Report

Current approaches to securing high consequence facilities (HCF) and critical assets are linear and static and therefore struggle to adapt to emerging threats (e.g., unmanned aerial systems) and changing environmental conditions (e.g., decreasing operational control). The pace of change in technological, organizational, societal, and political dynamics necessitates a move toward codifying underlying scientific principles to better characterize the rich interactions observed between HCF security technology, infrastructure, digital assets, and human or organizational components. The promising results of Laboratory Directed Research and Development (LDRD) 20-0373—“Developing a Resilient, Adaptive, and Systematic Paradigm for Security Analysis”—suggest that when compared to traditional security analysis, invoking multilayer network (MLN) modeling for HCF security system components captures unexpected failure cases and unanticipated interactions.

97 MATHEMATICS AND COMPUTING↗

Fracture mechanics technology for optimum pressure vessel design.

A technique has been developed to design a maximum efficiency reliable pressure vessel of given geometry and service life. The technique for ensuring reliability of the minimum weight vessel relies on the application of linear elastic fracture mechanics and fracture mechanics concepts. The resultant design incorporates potential fatigue and stress corrosion crack extension during service of a worst case initial flaw. Maximum stress for safe life is specified by the design technique, thereby minimizing weight. Ratios of pressure and toughness parameters are employed to avoid arbitrary specification of design stress level which would lead to a suboptimum design.

Bjeletich, J. G.↗

NASA's mobile satellite communications program; ground and space segment technologies

This paper describes the Mobile Satellite Communications Program of the United States National Aeronautics and Space Administration (NASA). The program's objectives are to facilitate the deployment of the first generation commercial mobile satellite by the private sector, and to technologically enable future generations by developing advanced and high risk ground and space segment technologies. These technologies are aimed at mitigating severe shortages of spectrum, orbital slot, and spacecraft EIRP which are expected to plague the high capacity mobile satellite systems of the future. After a brief introduction of the concept of mobile satellite systems and their expected evolution, this paper outlines the critical ground and space segment technologies. Next, the Mobile Satellite Experiment (MSAT-X) is described. MSAT-X is the framework through which NASA will develop advanced ground segment technologies. An approach is outlined for the development of conformal vehicle antennas, spectrum and power-efficient speech codecs, and modulation techniques for use in the non-linear faded channels and efficient multiple access schemes. Finally, the paper concludes with a description of the current and planned NASA activities aimed at developing complex large multibeam spacecraft antennas needed for future generation mobile satellite systems.

Naderi, F.↗

HOLLOTRON switch for megawatt lightweight space inverters

The feasibility of satisfying the switching requirements for a megawatt ultralight inverter system using HOLLOTRON switch technology was determined. The existing experimental switch hardware was modified to investigate a coaxial HOLLOTRON switch configuration and the results were compared with those obtained for a modified linear HOLLOTRON configuration. It was concluded that scaling the HOLLOTRON switch to the current and voltage specifications required for a megawatt converter system is indeed feasible using a modified linear configuration. The experimental HOLLOTRON switch operated at parameters comparable to the scaled coaxial HOLLOTRON. However, the linear HOLLOTRON data verified the capability for meeting all the design objectives simultaneously including current density (greater than 2 A/sq cm), voltage (5 kV), switching frequency (20 kHz), switching time (300 ns), and forward voltage drop (less than or equal to 20 V). Scaling relations were determined and a preliminary design was completed for an engineering model linear HOLLOTRON switch to meet the megawatt converter system specifications.

Poeschel, R. L.↗

Multiple beam antenna/switch system study

In the study of the Multiple Beam Antenna/Switch for the space to ground link (SGL) uplink and downlink services, several issues related to system engineering, antenna, transmit/receive, and switch systems were addressed and the results are provided. Bandwidth allocation at Ku band is inadequate to serve the data rate requirements for the forward and return services. Rain and depolarization effects at EHF, especially at Ka band, pose a significant threat to the link availabilities at heavy rain areas. Hardware induced effects such as the nonlinear characteristics of the power amplifier may necessitate the use of linearizers and limiters. It is also important to identify the components that are susceptible to the space radiation effects and shield or redesign them with rad-hard technologies for meeting the requirements of the space environment.

Source record↗

Spacecraft On-Board Information Extraction Computer (SOBIEC)

The Jet Propulsion Laboratory is the Technical Monitor on an SBIR Program issued for Irvine Sensors Corporation to develop a highly compact, dual use massively parallel processing node known as SOBIEC. SOBIEC couples 3D memory stacking technology provided by nCUBE. The node contains sufficient network Input/Output to implement up to an order-13 binary hypercube. The benefit of this network, is that it scales linearly as more processors are added, and it is a superset of other commonly used interconnect topologies such as: meshes, rings, toroids, and trees. In this manner, a distributed processing network can be easily devised and supported. The SOBIEC node has sufficient memory for most multi-computer applications, and also supports external memory expansion and DMA interfaces. The SOBIEC node is supported by a mature set of software development tools from nCUBE. The nCUBE operating system (OS) provides configuration and operational support for up to 8000 SOBIEC processors in an order-13 binary hypercube or any subset or partition(s) thereof. The OS is UNIX (USL SVR4) compatible, with C, C++, and FORTRAN compilers readily available. A stand-alone development system is also available to support SOBIEC test and integration.

Eisenman, David↗

Reusable Launch Vehicle Control in Multiple Time Scale Sliding Modes

A reusable launch vehicle control problem during ascent is addressed via multiple-time scaled continuous sliding mode control. The proposed sliding mode controller utilizes a two-loop structure and provides robust, de-coupled tracking of both orientation angle command profiles and angular rate command profiles in the presence of bounded external disturbances and plant uncertainties. Sliding mode control causes the angular rate and orientation angle tracking error dynamics to be constrained to linear, de-coupled, homogeneous, and vector valued differential equations with desired eigenvalues placement. The dual-time scale sliding mode controller was designed for the X-33 technology demonstration sub-orbital launch vehicle in the launch mode. 6DOF simulation results show that the designed controller provides robust, accurate, de-coupled tracking of the orientation angle command profiles in presence of external disturbances and vehicle inertia uncertainties. It creates possibility to operate the X-33 vehicle in an aircraft-like mode with reduced pre-launch adjustment of the control system.

Shtessel, Yuri↗

Ultra Stable Microwave Radiometers for Future Sea Surface Salinity Missions

The NASA Earth Science System Pathfinder (ESSP) mission Aquarius will measure global sea surface salinity with 100-km spatial resolution every 8 days with an average monthly salinity accuracy of 0.2 psu (parts per thousand). This requires an L-band low-noise radiometer with the long-term calibration stability of less than 0.1 K over 8 days. This three-year research program on ultra stable radiometers has addressed the radiometer requirements and configuration necessary to achieve this objective for Aquarius and future ocean salinity missions. The system configuration and component performance have been evaluated with radiometer testbeds at both JPL and GSFC. The research has addressed several areas including component characterization as a function of temperature, a procedure for the measurement and correction for radiometer system non-linearity, noise diode calibration versus temperature, low noise amplifier performance over voltage, and temperature control requirements to achieve the required stability. A breadboard radiometer, utilizing microstrip-based technologies, has been built to demonstrate this long-term stability. This report also presents the results of the radiometer test program, a detailed radiometer noise model, and details of the operational switching sequence optimization that can be used to achieve the low noise and stability requirements. Many of the results of this research have been incorporated into the Aquarius radiometer design and will allow this instrument to achieve its goals.

sea surface salinity↗

Metrology of Large Parts

As discussed in the first chapter of this book, there are many different methods to measure a part using optical technology. Chapter 2 discussed the use of machine vision to measure macroscopic features such as length and position, which was extended to the use of interferometry as a linear measurement tool in chapter 3, and laser or other trackers to find the relation of key points on large parts in chapter 4. This chapter looks at measuring large parts to optical tolerances in the sub-micron range using interferometry, ranging, and optical tools discussed in the previous chapters. The purpose of this chapter is not to discuss specific metrology tools (such as interferometers or gauges), but to describe a systems engineering approach to testing large parts. Issues such as material warpage and temperature drifts that may be insignificant when measuring a part to micron levels under a microscope, as will be discussed in later chapters, can prove to be very important when making the same measurement over a larger part. In this chapter, we will define a set of guiding principles for successfully overcoming these challenges and illustrate the application of these principles with real world examples. While these examples are drawn from specific large optical testing applications, they inform the problems associated with testing any large part to optical tolerances. Manufacturing today relies on micrometer level part performance. Fields such as energy and transportation are demanding higher tolerances to provide increased efficiencies and fuel savings. By looking at how the optics industry approaches sub-micrometer metrology, one can gain a better understanding of the metrology challenges for any larger part specified to micrometer tolerances. Testing large parts, whether optical components or precision structures, to optical tolerances is just like testing small parts, only harder. Identical with what one does for small parts, a metrologist tests large parts and optics in particular to quantify their mechanical properties (such as dimensions, mass, etc); their optical prescription or design (i.e. radius of curvature, conic constant, vertex location, size); and their full part shape. And, just as with small parts, a metrologist accomplishes these tests using distance measuring instruments such as tape measures, inside micrometers, coordinate measuring machines, distance measuring interferometers; angle measuring instruments such as theodolites, autocollimators; and surface measuring instruments including interferometers, stylus profilers, interference microscopes, photogrammetric cameras, or other tools. However, while the methodology may be similar, it is more difficult to test a large object for the simple reason that most metrologists do not have the necessary intuition. The skills used to test small parts or optics in a laboratory do not extrapolate to testing large parts in an industrial setting any more than a backyard gardener might successfully operate a farm. But first, what is a large part? A simple definition might be the part's size or diameter. For optics and diffuse surface parts alike, the driving constraint is ability to illuminate the part's surface. For reflective convex mirrors, large is typically anything greater than 1 meter. But, for refractive optics, flats or convex mirrors, large is typically greater than 0.5 meter. While a size definition is simple, it may be less than universal. A more nuanced definition might be that a large part is any component which cannot be easily tested in a standard laboratory environment, on a standard vibration isolated table using standard laboratory infrastructure. A micro-switch or a precision lens might be easily measured to nanometer levels under a microscope in a lab, but a power turbine spline or a larger telescope mirror will not fit under that microscope and may not even fit on the table.

Stahl, H. Philip↗