Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Magnetically Ordered Electrolytic Coatings in Hydraulic Systems

The application of wear-resistant coatings in the presence of a magnetic field is proposed for components of hydraulic systems. A method is developed for controlling the residual stress and mechanical properties by means of crystallographic anisotropy.

36 MATERIALS SCIENCE↗

Improved operation of magnetic bearings for flywheel energy storage system

Analysis and operation of prototype 500-Wh flywheel at low speeds have shown that many factors affect the correct functioning of the magnetic bearings. An examination is made of a number of these, including magnetic bearing control system nonlinearities and displacement transducer positioning, and their effects upon the successful operation of the suspension system. It is observed that the bearing control system is extremely sensitive to actuator parameters such as coil inductance. As a consequence of the analysis of bearing relaxation oscillations, the bearing actuator design methodology which has previously been used, where coil parameter selection is based upon static considerations, has been revised. Displacement transducer sensors which overcome the collocation problem are discussed.

Zmood, R. B.↗

Magnetic bearings for a spaceflight optical disk recorder

The development and testing of a magnetic bearing system for the translator of the read/write head in a magneto-optic disk drive are discussed. The asymmetrical three-pole actuators with permanent magnet bias support the optical head, and its tracking and focusing servos, through their radial excursion above the disk. The specifications for the magnetic bearing are presented, along with the configuration of the magnetic hardware. Development of a five degree of freedom collision model is examined which allowed assessment of the system response during large scale transients. Experimental findings and the results of performance testing are presented, including the roll-off of current-to-force due to eddy current loss in the magnetic materials.

Hockney, Richard↗

The 3SPACE digitizer: A new input device for solid geometry modeling

The 3SPACE Digitizer is a derivation of SPASYN, which is a patented magnetic transducing system offering an accurate method of calculating the location of one object relative to another. SPASYN uses low-frequency magnetic fields to measure both the position and orientation of its sensor relative to its transmitter. The 3SPACE Digitizer unit consists of a system's electronics unit, a model table, a stylus, and a keypad. In operation, the 3SPACE Digitizer determines the X, Y, Z coordinates of any point located on a low-conductive, three-dimensional model. This data, along with the orientation of the Digitizer's stylus, is immediately available for transmission to a host computer or graphics terminal. Digitization is effected by touching the point to be measured with the tip of a handheld stylus. The 3SPACE Digitizer presents new opportunities for interacting with computers in a large number of engineering and scientific applications. Developed from proven military technology, the 3SPACE Digitizer significantly simplifies three-dimensional digitization and overcomes many of the problems that once plagued such procedures. Its ability to digitize solid objects makes it a valuable new tool for computer-aided design and manufacturing.

Scully, J.↗

Probing the interplay between lattice dynamics and short-range magnetic correlations in CuGeO 3 with femtosecond RIXS

Investigations of magnetically ordered phases on the femtosecond timescale have provided significant insights into the influence of charge and lattice degrees of freedom on the magnetic sub-system. However, short-range magnetic correlations occurring in the absence of long-range order, for example in spin-frustrated systems, are inaccessible to many ultrafast techniques. Here, we show how time-resolved resonant inelastic X-ray scattering (trRIXS) is capable of probing such short-ranged magnetic dynamics in a charge-transfer insulator through the detection of a Zhang–Rice singlet exciton. Utilizing trRIXS measurements at the O K-edge, and in combination with model calculations, we probe the short-range spin correlations in the frustrated spin chain material CuGeO 3 following photo-excitation, revealing a strong coupling between the local lattice and spin sub-systems.

36 MATERIALS SCIENCE↗

First and subsequent return stroke properties of cloud-to-ground lightning

Lightning properties obtained by a network of magnetic direction finders and by electric field measurements for distances from 50 to 500 km are compared for three summer thunderstorms in Sweden. The data from direct field recordings indicate 31, 17, and 26 pcts. of negative subsequent return strokes with peak current (as inferred from the peak electric field) higher than the first. Electric fields from first strokes are compared with normalized amplitudes registered by the magnetic direction finding system. The efficiency of detection by the magnetic direction finding system is discussed in terms of the percentage of lightning flashes observed by electric field measurements that are not localized. Statistics of the number of strokes per flash and the interstroke time intervals are presented.

Namasivayam, S.↗

A magnetospheric magnetic field model with flexible current systems driven by independent physical parameters

A tilt-dependent magnetic field model of the Earth's magnetosphere with variable magnetopause standoff distance is presented. Flexible analytic representations for the ring and cross-tail currents, each composed of the elements derived from the Tsyganenko and Usmanov (1982) model, are combined with the fully shielded vacuum dipole configurations of Voigt (1981). Although the current sheet does not warp in the y-z plane, changes in the shape and position of the neutral sheet with dipole tilt are consistent with both MHD equilibrium theory and observations. In addition, there is good agreement with observed Delta B profiles and the average equatorial contours of magnetic field magnitude. While the dipole field is rigorously shielded within the defined magnetopause, the ring and cross-tails currents are not similarly confined, consequently, the model's region of validity is limited to the inner magnetosphere. The model depends on four independent external parameters. We present a simple but limited method of simulating several substorm related magnetic field changes associated with the disrupion of the near-Earth cross-tail current sheet and collapse of the midnight magnetotail field region. This feature further facilitates the generation of magnetic field configuration time sequences useful in plasma convection simulations of real magnetospheric events.

Hilmer, Robert V.↗

Thermal to electricity conversion using thermal magnetic properties

A system for the generation of Electricity from Thermal Energy using the thermal magnetic properties of a Ferromagnetic, Electrically Conductive Material (FECM) in one or more Magnetic Fields. A FECM is exposed to one or more Magnetic Fields. Thermal Energy is applied to a portion of the FECM heating the FECM above its Curie Point. The FECM, now partially paramagnetic, moves under the force of the one or more Magnetic Fields. The movement of the FECM induces an electrical current through the FECM, generating Electricity.

30 DIRECT ENERGY CONVERSION↗

High energy electron diffraction instrument with tunable camera length

Ultrafast electron diffraction (UED) stands as a powerful technique for real-time observation of structural dynamics at the atomic level. In recent years, the use of MeV electrons from radio frequency guns has been widely adopted to take advantage of the relativistic suppression of the space charge effects that otherwise limit the temporal resolution of the technique. Nevertheless, there is not a clear choice for the optimal energy for a UED instrument. Scaling to beam energies higher than a few MeV does pose significant technical challenges, mainly related to the inherent increase in diffraction camera length associated with the smaller Bragg angles. In this study, we report a solution by using a compact post-sample magnetic optical system to magnify the diffraction pattern from a crystal Au sample illuminated by an 8.2 MeV electron beam. Our method employs, as one of the lenses of the optical system, a triplet of compact, high field gradients (>500 T/m), small-gap (3.5 mm) Halbach permanent magnet quadrupoles. Shifting the relative position of the quadrupoles, we demonstrate tuning the magnification by more than a factor of two, a 6× improvement in camera length, and reciprocal space resolution better than 0.1 Å –1 in agreement with beam transport simulations.

47 OTHER INSTRUMENTATION↗

Cryogen-free modular scanning tunneling microscope operating at 4-K in high magnetic field on a compact ultra-high vacuum platform

One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen-free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high magnetic field (HF), and compatibility with μm-sized samples, pose additional challenges to an already ambitious build. We present the design, construction, and performance of a cryogen-free, UHV, low temperature, and high magnetic field system for modular STM operation. An internal vibration isolator reduces vibrations in this system, allowing for atomic resolution STM imaging while maintaining a low base temperature of ∼4 K and magnetic fields up to 9 T. Samples and tips can be conditioned in situ utilizing a heating stage, an ion sputtering gun, an e-beam evaporator, a tip treater, and sample exfoliation. In situ sample and tip exchange and alignment are performed in a connected UHV room temperature stage with optical access. Multisite operation without breaking vacuum is enabled by a unique quick-connect STM head design. A novel low-profile vertical transfer mechanism permits transferring the STM between room temperature and the low temperature cryostat.

Instruments & Instrumentation↗

A precision pointing system for Shuttle experiment payloads

This paper describes the Annular Suspension and Pointing System (ASPS) being developed to support NASA Shuttle payloads in the 1980s. The ASPS employs a unique magnetic suspension system to isolate Shuttle payloads from Orbiter disturbances and provide vernier control of the payload's attitude, thereby allowing extremely accurate and stable pointing. A description of the system design, configurations, and performance goals is given. Component and system development testing of the full-size ASPS Engineering Development Model is described, and hardware photographs and test configurations are presented.

Van Riper, R.↗

Magnetic fields, plasmas, and coronal holes - The inner solar system

Recent results concerning streams and magnetic fields in the inner solar system are reviewed. Observations have shown that MHD streams are bounded by thin shear layers within 1 AU, probably because they originate in coronal holes which have sharp boundaries. The properties of Alfvenic fluctuations in streams cannot be fully explained on the basis of the hypothesis that they are plane, transverse Alfven waves. A more complete and accurate description might be that they represent nonplanar general Alfven waves weakly coupled to a compressive mode and moving through a medium containing tangential discontinuities and other convected inhomogeneities.

Burlaga, L. F.↗

Determination of broken KAM surfaces for particle orbits in toroidal confinement systems

Here, the destruction of Kolmogorov–Arnold–Moser surfaces in a Hamiltonian system is an important topic in nonlinear dynamics, and in particular in the theory of particle orbits in toroidal magnetic confinement systems. Analytic models for transport due to mode-particle resonances are not sufficiently correct to give the effect of these resonances on transport. In this paper we compare three different methods for the detection of the loss of stability of orbits in the dynamics of charged particles in a toroidal magnetic confinement device in the presence of time dependent magnetic perturbations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Topological kinetic crossover in a nanomagnet array

Ergodic kinetics, which are critical to equilibrium thermodynamics, can be constrained by a system’s topology. Here, we studied a model nanomagnetic array in which such constraints visibly affect the behavior of the magnetic moments. In this system, magnetic excitations connect into thermally active one-dimensional strings whose motion can be imaged in real time. At high temperatures, our data showed the merging, breaking, and reconnecting of strings, resulting in the system transitioning between topologically distinct configurations. Below a crossover temperature, the string motion is dominated by simple changes in length and shape. In this low-temperature regime, the system is energetically stable because of its inability to explore all possible topological configurations. This kinetic crossover suggests a generalizable conception of topologically broken ergodicity and limited equilibration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic Field Response Measurement Acquisition System

This paper presents a measurement acquisition method that alleviates many shortcomings of traditional measurement systems. The shortcomings are a finite number of measurement channels, weight penalty associated with measurements, electrical arcing, wire degradations due to wear or chemical decay and the logistics needed to add new sensors. Wire degradation has resulted in aircraft fatalities and critical space launches being delayed. The key to this method is the use of sensors designed as passive inductor-capacitor circuits that produce magnetic field responses. The response attributes correspond to states of physical properties for which the sensors measure. Power is wirelessly provided to the sensing element by using Faraday induction. A radio frequency antenna produces a time-varying magnetic field used to power the sensor and receive the magnetic field response of the sensor. An interrogation system for discerning changes in the sensor response frequency, resistance and amplitude has been developed and is presented herein. Multiple sensors can be interrogated using this method. The method eliminates the need for a data acquisition channel dedicated to each sensor. The method does not require the sensors to be near the acquisition hardware. Methods of developing magnetic field response sensors and the influence of key parameters on measurement acquisition are discussed. Examples of magnetic field response sensors and the respective measurement characterizations are presented. Implementation of this method on an aerospace system is discussed.

Woodard, Stanley E.↗

Element-specific first order reversal curves measured by magnetic transmission x-ray microscopy

The first-order reversal curve (FORC) method is a macroscopic measurement technique that can be used to extract quantitative and microscopic properties of hysteretic systems. Using magnetic transmission x-ray microscopy (MTXM), local element-specific FORC measurements are performed on a 20 nm thick film of CoTb. The FORCs measured with microscopy reveal a step-by-step domain evolution under the magnetic field cycling protocol and provide a direct visualization of the mechanistic interpretation of FORC diagrams. They are compared with magnetometry FORCs and show good quantitative agreement. Furthermore, the high spatial resolution and element-specific sensitivity of MTXM provide new capabilities to measure FORCs in small regions or specific phases within multicomponent systems, including buried layers in heterostructures. The ability to perform FORCs on very small features is demonstrated with the MTXM-FORC measurement of a rectangular microstructure with vortex-like Landau structures. This work demonstrates the confluence of two uniquely powerful techniques to achieve quantitative insight into nanoscale magnetic behavior.

36 MATERIALS SCIENCE↗

Magnetic Field Response Measurement Acquisition System

A measurement acquisition method that alleviates many shortcomings of traditional measurement systems is presented in this paper. The shortcomings are a finite number of measurement channels, weight penalty associated with measurements, electrical arcing, wire degradations due to wear or chemical decay and the logistics needed to add new sensors. The key to this method is the use of sensors designed as passive inductor-capacitor circuits that produce magnetic field responses. The response attributes correspond to states of physical properties for which the sensors measure. A radio frequency antenna produces a time-varying magnetic field used to power the sensor and receive the magnetic field response of the sensor. An interrogation system for discerning changes in the sensor response is presented herein. Multiple sensors can be interrogated using this method. The method eliminates the need for a data acquisition channel dedicated to each sensor. Methods of developing magnetic field response sensors and the influence of key parameters on measurement acquisition are discussed.

Woodard, Stanley E.↗