Search NASA⌕ Search

SEARCH · Search NASA

Results for “MULTIPLE SCATTERING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Verification of the 2D Finite Element SP3 Solutions

Method(FEM) is the free geometry handling. However many of the geometries of the nuclear engineering problems are not unstructured but rather structured, such as a hexahedral, or triangular prism. Thus, the need for the use of FEM has less portion in nuclear engineering. However it is also certain that it is very hard to exclude the possibility for use of an unstructured geometry such as a PBMR core problem, fusion blanket analysis of the source problem, another design issue with an unstructured geometry. In addition, research regarding the acceleration scheme such as Coarse Mesh Finite Difference (CMFD) showed up in nuclear engineering in recent years. By considering these facts, the FEM cannot be totally exclusive. To utilize the FEM for nuclear engineering problems, several types of assistance are needed. The first is parallelization because of its slow calculation speed. The second is an acceleration scheme. With these two types of assistance the FEM can be utilized freely in the nuclear engineering field. In this research, before conducting parallelization and acceleration, the final verification for the implementation of the up-scattering treatment with an arbitrary geometry conducted through a comparison with the McCARD solution through the well-known C5G7 2D benchmark problem. Note that the earlier work for verification of the FEM for the multi-group problem without up-scattering and with a structured geometry including a mathematical formulation has already been done. The main points that will be tested here are as follows. The first is a check of the right implementation for the multi-group problem with an up-scattering cross section from the perspectives of the multiplication factor and power. The second is the transport effect for this problem by comparing the solutions from P{sub 1} and Simplified P{sub 3}(SP{sub 3}). The third is the effectiveness of the higher order basis function for the same number of unknowns. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutron and Gamma Correlations using CGM in MCNP 6.2.0

The general-purpose Monte Carlo radiation-transport code MCNP6{sup TM} came from the integration of MCNP5{sup TM} and MCNPX{sup TM}. The most recent release of MCNP, version 6.2.0, is scheduled for release in early 2017, which includes a variety of bug fixes and new features to the code. MCNP traditionally models nuclear reactions using Monte Carlo sampling techniques on measured and modeled cross-sectional data contained within ACE (A Compact Evaluated Nuclear Data File) libraries. In addition to reaction cross-sections, ACE libraries contain information relating to the production of secondary particles, such as secondary neutrons and photons. For example, an incident neutron on a nucleus can produce a nuclear reaction in the form (n, M{sub n}n'), where n is the incident neutron and M{sub n} is the number of secondary neutrons n' produced. Using this notation, different reactions can be described based on their neutron multiplicity, such as neutron capture (M{sub n} = 0), elastic and inelastic scattering (M{sub n} = 1), and reactions with multiple secondary neutrons (M{sub n} > 1). Accounting for secondary γ-rays emitted from the residual nuclei, this reaction can further be generalized as n, Mnn'M to describe a reaction producing M{sub n} neutrons and M -rays. These values M{sub n} and M are referred to as the neutron and multiplicities, respectively. ACE libraries contain the cross-sectional data for each reaction, and their corresponding statistically averaged multiplicities for neutrons and photons, M-bar{sub n} and M-bar{sub γ}. However, there are several limitations to reaction sampling using ACE libraries. First, the data contained within ACE libraries is limited by the accuracy of the model and/or experiment, which out of necessity can greatly simplify the true physics behind a reaction. For example, the value M{sub γ} in a (n, M{sub n}n'M{sub γ}γ) reaction is determined by the statistically averaged multiplicity M-bar{sub γ} instead of a distribution. Consequently, MCNP, unable to produce a continuous distribution, will utilizes a binary sampling around M-bar{sub γ}. While this sampling method provides a statistically average M{sub γ} over a large simulation, it is an inaccurate representation of an individual reaction and its corresponding secondary particles. Secondary neutrons are affected in a similar manner, such that different kinds of secondary neutrons can be sampled from the same interaction (eg., an inelastic neutron with an [n, 2n] neutron). Lastly, the random sampling technique for secondary particles remains completely independent of the sampled reaction, eliminating the ability to correlate secondary particles for a given reaction. To supplement these data libraries, additional codes and models describing certain nuclear reactions are employed. These codes can fill in the information missing from ACE, provide a better model to the true physics distribution, and can provide true correlated secondary particles, which has many useful applications in research and industry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Total thermal neutron cross section measurements of yttrium hydride from 0.0005 - 3 eV

Yttrium hydride serves as a neutron moderator material that enables compact, high temperature nuclear reactors. However, in order to accurately design and simulate a nuclear system relying upon yttrium hydride, the fundamental nuclear data of yttrium hydride must be well understood. Thermal neutron scattering law (TSL) evaluations represent an important aspect of nuclear data as thermal scattering can drastically alter the neutron multiplication factor of a system. Therefore, to support evaluation and validation of thermal neutron scattering for yttrium hydride, researchers at Rensselaer Polytechnic Institute (RPI) performed total thermal neutron cross section measurements for YH 1.68 and YH 1.85 over the energy range of 0.0005 - 3 eV. Further, these measurements represent the first total cross section measurements for yttrium hydride that encompass the entire thermal region. Comparisons were made against the ENDF-B/VIII.0, Zerkle & Holmes and Oak Ridge National Laboratory TSL evaluations, where generally good agreement was found.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Structures of glasses created by multiple kinetic arrests

X-ray scattering has been used to characterize glassy itraconazole (ITZ) prepared by cooling at different rates. Faster cooling produces ITZ glasses with lower (or zero) smectic order with more sinusoidal density modulation, larger molecular spacing, and shorter lateral correlation between the rod-like molecules. We find that each glass is characterized by not one, but two fictive temperatures T f (the temperature at which a chosen order parameter is frozen in the equilibrium liquid). The higher T f is associated with the regularity of smectic layers and lateral packing, while the lower T f with the molecular spacings between and within smectic layers. This indicates that different structural features are frozen on different timescales. The two timescales for ITZ correspond to its two relaxation modes observed by dielectric spectroscopy: the slower δ mode (end-over-end rotation) is associated with the freezing of the regularity of molecular packing and the faster α mode (rotation about the long axis) with the freezing of the spacing between molecules. Finally, our finding suggests a way to selectively control the structural features of glasses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SNS Sample Activation Calculator Experimental Validation - Paper 79

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) uses the Sample Activation Calculator (SAC) to calculate the activation of all samples after they have been exposed to the neutron beam in any of the neutron scattering instruments at the SNS beamlines. The SAC web page takes user inputs (choice of beamline, the mass, composition and area of the sample, irradiation time, decay time, etc.) and then calculates the activation for the sample. In recent years, the SAC has been incorporated into the user proposal and sample handling process, and beamline scientists and users have noticed discrepancies in the predicted activation of their samples. As a part of the Neutronics Analysis Group at SNS, we were tasked with validating the SAC tool and diagnosing the origin of the discrepancies seen by the beamline scientists and the users. In the process of performing these measurements, we additionally found that several aspects of realistic neutron scattering operations, and thus sample exposure, cannot be captured with current configuration of the SAC tool. Typical neutron scattering samples are irradiated for multiple periods with different neutron energy ranges; the realities of accelerator operation indicate that not all of those periods will be at the same accelerator power, and scattering samples are frequently not fully illuminated by the well-collimated neutron beam. Finally, we will explore whether neutron beams, as modified by neutron guide systems with energy-dependent intensity modifications and by precise energy-band defining mechanical choppers, are suitably analyzed with multigroup cross section libraries in which there are typically very few energy groups below one eV. (authors)

43 PARTICLE ACCELERATORS↗

Insights into hyperbolic phonon polaritons in h – BN using Raman scattering from encapsulated transition metal dichalcogenide layers

Alternative techniques for probing hyperbolic phonon polaritons (HPPs) in two-dimensional materials will support the development of the emerging technologies in this field. Previous reports have shown that it is possible for W Se 2 monolayers in contact with the hexagonal boron nitride (h– BN) to generate HPPs in the h– BN via Raman scattering. In this paper, we set out our results on HPP Raman scattering induced in h– BN by W Se 2 and Mo Se 2 monolayers including multiple resonances at which the Raman scattering is enhanced. Analysis of the observed Raman line shapes demonstrates that Raman scattering allows HPPs with wave vectors with magnitudes significantly in excess of 15 000 cm –1 to be probed. Finally, we present evidence that the Raman scattering can probe HPPs with frequencies less than the expected lower bound on the reststrahlen band, suggesting new HPP physics still waits to be discovered.

2-dimensional systems↗

Scatter gather using key-value store

Scatter gather operation(s) are performed by accessing a shared memory that is shared amongst nodes interconnected through network(s) and having a CNS shared amongst the nodes. Data is gathered from multiple processes at corresponding multiple nodes into location(s) in the CNS, and tuple(s) having a same tuple name are created in the CNS. The tuple(s) have information referencing the gathered data in the location(s). Alternatively, data that has been gathered using the same tuple name is scattered to multiple processes participating in the CNS. The scattering uses the tuple(s) in the CNS, and is performed from the location(s) into other location(s) at one or multiple nodes for one or multiple processes at the corresponding one or multiple nodes. Both the gathering data and the scattering data may also be performed.

Jacob, Philip↗

Collision Tracking in OpenMC: Methods and Applications in Neutron Noise, Neutron Imaging, Time-of-Flight, and Multiplicity Counting

We present the development and application of a collision tracking feature within the OpenMC Monte Carlo particle transport code, designed for diverse applications such as neutron spectroscopy, scatter camera system, neutron noise, and multiplicity counting simulations. This feature enables the tracking of individual particle collisions, with potential applications in nuclear nonproliferation, reactor physics, and nuclear security. Additionally, the feature holds potential for the calibration of neutron detectors, specifically in converting light output into energy deposited within the detectors. The implementation consists of a set of filters—such as reaction type, energy, cell, and material—that constrain the set of collisions that are tracked, extensions to the Python API to enable simple input specification, and support for writing either OpenMC’s native HDF5-based format or the Monte Carlo particle list format. This feature was added to the official OpenMC release in version 0.15.3. In this work, the feature will be applied to showcase scenarios such as time-of-flight simulations, scatter-camera imaging for neutron source localization, neutron-noise analysis to extract integral kinetic parameters such as the prompt decay constant α, and multiplicity counting to estimate the mass of special nuclear materials. Ultimately, this feature aims to expand the application scope of open-source Monte Carlo particle transport codes such as OpenMC.

Monte Carlo code↗

X-ray scattering based scanning tomography for imaging and structural characterization of cellulose in plants

X-ray and neutron scattering have long been used for structural characterization of cellulose in plants. Due to averaging over the illuminated sample volume, these measurements traditionally overlooked the compositional and morphological heterogeneity within the sample. Here, a scanning tomographic imaging method is described, using contrast derived from the X-ray scattering intensity, for virtually sectioning the sample to reveal its internal structure at a resolution of a few micrometres. This method provides a means for retrieving the local scattering signal that corresponds to any voxel within the virtual section, enabling characterization of the local structure using traditional data-analysis methods. This is accomplished through tomographic reconstruction of the spatial distribution of a handful of mathematical components identified by non-negative matrix factorization from the large dataset of X-ray scattering intensity. Joint analysis of multiple datasets, to find similarity between voxels by clustering of the decomposed data, could help elucidate systematic differences between samples, such as those expected from genetic modifications, chemical treatments or fungal decay. The spatial distribution of the microfibril angle can also be analyzed, based on the tomographically reconstructed scattering intensity as a function of the azimuthal angle.

36 MATERIALS SCIENCE↗

Quality assurance of proton beams using a multilayer ionization chamber system

Purpose: The measurement of percentage depth-dose (PDD) distributions for the quality assurance of clinical proton beams is most commonly performed with a computerized water tank dosimetry system with ionization chamber, commonly referred to as water tank. Although the accuracy and reproducibility of this method is well established, it can be time-consuming if a large number of measurements are required. In this work the authors evaluate the linearity, reproducibility, sensitivity to field size, accuracy, and time-savings of another system: the Zebra, a multilayer ionization chamber system.Methods: The Zebra, consisting of 180 parallel-plate ionization chambers with 2 mm resolution, was used to measure depth-dose distributions. The measurements were performed for scattered and scanned proton pencil beams of multiple energies delivered by the Hitachi PROBEAT synchrotron-based delivery system. For scattered beams, the Zebra-measured depth-dose distributions were compared with those measured with the water tank. The principal descriptors extracted for comparisons were: range, the depth of the distal 90% dose; spread-out Bragg peak (SOBP) length, the region between the proximal 95% and distal 90% dose; and distal-dose fall off (DDF), the region between the distal 80% and 20% dose. For scanned beams, the Zebra-measured ranges were compared with those acquired using a Bragg peak chamber during commissioning.Results: The Zebra demonstrated better than 1% reproducibility and monitor unit linearity. The response of the Zebra was found to be sensitive to radiation field sizes greater than 12.5 × 12.5 cm; hence, the measurements used to determine accuracy were performed using a field size of 10 × 10 cm. For the scattered proton beams, PDD distributions showed 1.5% agreement within the SOBP, and 3.8% outside. Range values agreed within −0.1 ± 0.4 mm, with a maximum deviation of 1.2 mm. SOBP length values agreed within 0 ± 2 mm, with a maximum deviation of 6 mm. DDF values agreed within 0.3 ± 0.1 mm, with a maximum deviation of 0.6 mm. For the scanned proton pencil beams, Zebra and Bragg peak chamber range values demonstrated agreement of 0.0 ± 0.3 mm with a maximum deviation of 1.3 mm. The setup and measurement time for all Zebra measurements was 3 and 20 times less, respectively, compared to the water tank measurements.Conclusions: Our investigation shows that the Zebra can be useful not only for fast but also for accurate measurements of the depth-dose distributions of both scattered and scanned proton beams. The analysis of a large set of measurements shows that the commonly assessed beam quality parameters obtained with the Zebra are within the acceptable variations specified by the manufacturer for our delivery system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simplified spin dependence in dark matter direct detection

The interactions of dark matter with Standard Model particles can be systematically studied in the language of effective field theories. We investigate dark matter interactions with Standard Model particles, including spin-dependent interactions, for direct detection experiments and demonstrate that, although the scattering rate generally depends on multiple types of material response functions, certain linear combinations of these material response functions vanish if the initial and final electronic states share the same Hamiltonian. We also find that several other response functions vanish in parity-symmetric materials, making these systems as simple as isotropic detectors in some respects. Finally, we present the scattering rate for an anisotropic, possibly chiral detector, for generic dark matter-electron spin interactions. These relations reduce the number of independent response functions needed, thereby simplifying the computational complexity for a broad class of dark matter models. Our results provide a complete and efficient toolkit for analyzing electron recoil signals in diverse detector materials.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A CRITICAL ASSESSMENT OF PHOTOMETRIC REDSHIFT METHODS: A CANDELS INVESTIGATION

We present results from the Cosmic Assembly Near-infrared Deep Extragalactic Legacy Survey (CANDELS) photometric redshift methods investigation. In this investigation, the results from 11 participants, each using a different combination of photometric redshift code, template spectral energy distributions (SEDs), and priors, are used to examine the properties of photometric redshifts applied to deep fields with broadband multi-wavelength coverage. The photometry used includes U-band through mid-infrared filters and was derived using the TFIT method. Comparing the results, we find that there is no particular code or set of template SEDs that results in significantly better photometric redshifts compared to others. However, we find that codes producing the lowest scatter and outlier fraction utilize a training sample to optimize photometric redshifts by adding zero-point offsets, template adjusting, or adding extra smoothing errors. These results therefore stress the importance of the training procedure. We find a strong dependence of the photometric redshift accuracy on the signal-to-noise ratio of the photometry. On the other hand, we find a weak dependence of the photometric redshift scatter with redshift and galaxy color. We find that most photometric redshift codes quote redshift errors (e.g., 68% confidence intervals) that are too small compared to that expected from the spectroscopic control sample. We find that all codes show a statistically significant bias in the photometric redshifts. However, the bias is in all cases smaller than the scatter; the latter therefore dominates the errors. Finally, we find that combining results from multiple codes significantly decreases the photometric redshift scatter and outlier fraction. We discuss different ways of combining data to produce accurate photometric redshifts and error estimates.

79 ASTRONOMY AND ASTROPHYSICS↗

Charged hadron multiplicities at the HERMES experiment

The HERMES collaboration has measured charge-separated pion and kaon multiplicities in semi-inclusive deep inelastic scattering using a 27.6 GeV electron or positron beam scattering off a hydrogen or deuterium target. The results are presented as a function of the Bjorken variable x {sub B }, the negative squared four-momentum transfer Q {sup 2}, the hadron fractional energy z and it’s transverse momentum P {sub h ⊥}. These data will be very useful to understand the quark-fragmentation process in deep-inelastic hadron electro-production and will serve as crucial input in the understanding of spin asymmetries in polarized semi-inclusive deep-inelastic scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of the energy dependence of the underlying event in proton-antiproton collisions

We study charged particle production (p(T) > 0.5 GeV/c, vertical bar eta vertical bar < 0.8) in proton-antiproton collisions at total center-of-mass energies root s = 300 GeV, 900 GeV, and 1.96 TeV. We use the direction of the charged particle with the largest transverse momentum in each event to define three regions of eta - phi space: "toward", "away", and "transverse." The average number and the average scalar pT sum of charged particles in the transverse region are sensitive to the modeling of the "underlying event." The transverse region is divided into a MAX and MIN transverse region, which helps separate the "hard component" (initial and final-state radiation) from the "beam-beam remnant" and multiple parton interaction components of the scattering. The center-of-mass energy dependence of the various components of the event is studied in detail. The data presented here can be used to constrain and improve QCD Monte Carlo models, resulting in more precise predictions at the LHC energies of 13 and 14 TeV.

Aaltonen, T.↗

Modeling of the Molten Salt Reactor Experiment with SCALE

A SCALE model was developed for the Molten Salt Reactor Experiment (MSRE) benchmark that was recently added to the International Handbook of Evaluated Reactor Physics Benchmark Experiments. This SCALE model served as a basis for criticality calculations and nuclear data sensitivity and uncertainty analyses with the Monte Carlo code Shift and the TSUNAMI computational capabilities in the SCALE code system. The focus of this work is the assessment of the impact of nuclear data on the calculated eigenvalue results in support of the discussion of differences between the calculated and the experimental eigenvalue result. The differences in the eigenvalues obtained using the ENDF/B-VII.0, ENDF/B-VII.1, and ENDF/B-VIII.0 nuclear data libraries cover a relatively small range of ~230 pcm. Since eigenvalue sensitivity of the MSRE is dominated by the neutron multiplicity and neutron capture of 235 U and elastic scattering in graphite, relevant changes in the ENDF/B libraries for nuclear reactions (such as carbon capture) that caused large differences in other graphite-moderated systems did not have a significant impact. Propagation of nuclear data uncertainty results in an eigenvalue uncertainty of ~700 pcm with the major contributors being 235 U neutron multiplicity, graphite elastic scattering, and 7Li neutron capture. All calculations resulted in large differences of ~2000 pcm in eigenvalue compared to the benchmark experimental value. Several potential contributors to this difference—including uncertainties and gaps in the knowledge of the material, geometry, and nuclear data—were identified. Simplified models of the full MSRE core were developed, and similarity assessments were conduced with the full MSRE core model. It was found that simplified models can serve as adequate surrogates of the full-core model such that they can be used for performing selected nuclear data performance assessments with a lower computational burden.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TH-C-19A-01: Analytic Design Method to Make a 2D Planar, Segmented Ion Chamber Water-Equivalent for Proton Dose Measurements

Purpose: Quality Assurance (QA) measurements of proton therapy fields must accurately measure steep longitudinal dose gradients as well as characterize the dose distribution laterally. Currently, available devices for two-dimensional field measurements perturb the dose distribution such that routine QA measurements performed at multiple depths require multiple field deliveries and are time consuming. Methods: A design procedure for a two-dimensional detector array is introduced whereby the proton energy loss and scatter are adjusted so that the downstream dose distribution is maintained to be equivalent to that which would occur in uniform water. Starting with the design for an existing, functional two-dimensional segmented ion chamber prototype, a compensating material is introduced downstream of the detector to simultaneously equate the energy loss and lateral scatter in the detector assembly to the values in water. An analytic formalism and procedure is demonstrated to calculate the properties of the compensating material in the general case of multiple layers of arbitrary material. The resulting design is validated with Monte Carlo simulations. Results: With respect to the specific prototype design considered, the results indicate that a graphite compensating layer of the proper dimensions can yield proton beam range perturbation less than 0.1mm and beam sigma perturbation less than 2% across the energy range of therapeutic proton beams. Conclusion: We have shown that, for a 2D gas-filled detector array, a graphite-compensating layer can balance the energy loss and multiple Coulomb scattering relative to uniform water. We have demonstrated an analytic formalism and procedure to determine a compensating material in the general case of multiple layers of arbitrary material. This work was supported by the US Army Medical Research and Materiel Command under Contract Agreement No. DAMD17-W81XWH-04-2-0022. Opinions, interpretations, conclusions and recommendations are those of the author and are not necessarily endorsed by the US Army.

07 ISOTOPE AND RADIATION SOURCES↗

Ratioed scatter diagrams - An erotetic method for phase identification on complex surfaces using scanning Auger microscopy

By ratioing multiple Auger intensities and plotting a two-dimensional occupational scatter diagram while digitally scanning across an area, the number and elemental association of surface phases can be determined. This can prove a useful tool in scanning Auger microscopic analysis of complex materials. The technique is illustrated by results from an anomalous region on the reaction zone of a SiC/Ti-6Al-4V metal matrix composite material. The anomalous region is shown to be a single phase associated with sulphur and phosphorus impurities. Imaging of a selected phase from the ratioed scatter diagram is possible and may be a useful technique for presenting multiple scanning Auger images.

Browning, R.↗

Diagnosing collisions of magnetized, high energy density plasma flows using a combination of collective Thomson scattering, Faraday rotation, and interferometry (invited)

A suite of laser based diagnostics is used to study interactions of magnetised, supersonic, radiatively cooled plasma flows produced using the Magpie pulse power generator (1.4 MA, 240 ns rise time). Collective optical Thomson scattering measures the time-resolved local flow velocity and temperature across 7–14 spatial positions. The scattering spectrum is recorded from multiple directions, allowing more accurate reconstruction of the flow velocity vectors. The areal electron density is measured using 2D interferometry; optimisation and analysis are discussed. The Faraday rotation diagnostic, operating at 1053 nm, measures the magnetic field distribution in the plasma. Measurements obtained simultaneously by these diagnostics are used to constrain analysis, increasing the accuracy of interpretation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗