Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Progress In Developing Laser Based Post Irradiation Examination Infrastructure

To be able to understand the performance of reactor fuels and materials, irradiated materials must be characterized effectively and efficiently in a high rad environment. The characterization work must be performed remotely and in an environment hostile to instrumentation. Laser based characterization techniques provide the ability to be remote and robust in a hot-cell environment. Laser based instrumentation also can provide high spatial resolution suitable for scanning and imaging large areas. The INL is currently developing three laser based Post Irradiation Examination (PIE) stations for the Hot Fuel Examination Facility at the INL. These laser based systems will characterize irradiated materials and fuels. The characterization systems are the following: Laser Shock Laser based ultrasonic C-scan system Gas Assay, Sample, and Recharge system (GASR, up-grade to an existing system). The laser shock technique will characterize material properties and failure loads/mechanisms in various materials such as LWR fuel, plate fuel, and next generation fuel forms, for PIE in high radiation areas. The laser shock-technique induces large amplitude shock waves to mechanically characterize interfaces such as the fuel-clad bond. The shock wave travels as a compression wave through the material to the free (unconfined) back surface and reflects back through the material under test as a rarefaction (tensile) wave. This rarefaction wave is the physical mechanism that produces internal de-lamination failure. As part of the laser shock system, a laser-based ultrasonic C-scan system will be used to detect and characterize debonding caused by the laser shock technique. The laser ultrasonic system will be fully capable of performing classical non-destructive evaluation testing and imaging functions such as microstructure characterization, flaw detection and dimensional metrology in complex components. The purpose of the GASR is to measure the pressure/volume of the plenum of an irradiated fuel element and obtain fission gas samples for analysis. The study of pressure and volume in the plenum of an irradiated fuel element and the analysis of fission gases released from the fuel is important to understanding the performance of reactor fuels and materials. This system may also be used to measure the pressure/volume of other components (such as control blades) and obtain gas samples from these components for analysis. The main function of the laser in this application is to puncture the fuel element to allow the fission gas to escape and if necessary to weld the spot close. The GASR station will have the inherent capability to perform cutting welding and joining functions within a hot-cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aluminum Stabilized NbTi Conductor Test Coil Design, Fabrication, and Test Results

A new generation of precision muon conversion experiments is planned at both Fermilab and KEK. These experiments will depend upon a complex set of solenoid magnets for the production, momentum selection and transport of a muon beam to a stopping target, and for tracking detector momentum analysis of candidate conversion electrons from the target. Baseline designs for the production and detector solenoids use NbTi cable that is heavily stabilized by an extruded high RRR aluminum jacket. A U.S.-Japan research collaboration has begun whose goal is to advance the development of optimized Al-NbTi conductors, gain experience with the technology of winding coils from this material, and test the conductor performance as modest length samples become available. For this purpose, a 'conductor test' solenoid with three coils was designed and built at Fermilab. A sample of the RIKEN Al-NbTi conductor from KEK was wound into a 'test' coil; this was sandwiched between two 'field' coils wound from doubled SSC cable, to increase the peak field on the RIKEN test coil. All three solenoid coils were epoxy impregnated, and utilized aluminum outer bandage rings to apply preload to the coils when cold. The design and fabrication details, and results of the magnet quench performance tests are presented and discussed.

43 PARTICLE ACCELERATORS↗

FABRICATION AND TESTING OF MICROWAVE SINTERED SOL-GEL SPRAY-ON BISMUTH TITANATE-LITHIUM NIOBATE BASED PIEZOELECTRIC COMPOSITE FOR USE AS A HIGH TEMPERATURE (>500 deg. C) ULTRASONIC TRANSDUCER

Bismuth titanate-lithium niobate based ultrasonic transducers have been fabricated using a sol-gel spray-on deposition technique. These transducers were then tested to determine their potential as high temperature ultrasonic transducers. Fabricated transducers were capable of operating to 1000 deg. C in pulse-echo mode; however, the exposure to such extreme temperatures appears to be destructive to the transducers.

36 MATERIALS SCIENCE↗

Comparison of plastic, high density carbon, and beryllium as indirect drive NIF ablators

Detailed radiation hydrodynamic simulations calibrated to experimental data have been used to compare the relative strengths and weaknesses of three candidate indirect drive ablator materials now tested at the NIF: plastic, High Density Carbon (HDC) or diamond, and beryllium. We apply a common simulation methodology to several currently fielded ablator platforms to benchmark the model and extrapolate designs to the full NIF envelope to compare on a more equal footing. This paper focuses on modeling of the hohlraum energetics which accurately reproduced measured changes in symmetry when changes to the hohlraum environment were made within a given platform. Calculations suggest that all three ablator materials can achieve a symmetric implosion at a capsule outer radius of 1100 m, laser energy of 1.8 MJ, and DT ice mass of 185 g. However, there is more uncertainty in the symmetry predictions for the plastic and beryllium designs. Scaled diamond designs had the most calculated margin for achieving symmetry and the highest fuel absorbed energy at the same scale compared to plastic or beryllium. A comparison of the relative hydrodynamic stability was made using ultra-high resolution capsule simulations and the two dimensional radiation fluxes described in this work. These simulations, which include low and high mode perturbations, suggest that diamond is currently the most promising for achieving higher yields in the near future followed by plastic and more data required to understand beryllium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of gas–wall interactions on measurements of semivolatile compounds and small polar molecules

Recent work has quantified the delay times in measurements of volatile organic compounds (VOCs) caused by the partitioning between the gas phase and the surfaces of the inlet tubing and instrument itself. In this study we quantify wall partitioning effects on time responses and transmission of multifunctional, semivolatile, and intermediate-volatility organic compounds (S/IVOCs) with saturation concentrations ( C * ) between 10 0 and 10 4 µg m -3 . The instrument delays of several chemical ionization mass spectrometer (CIMS) instruments increase with decreasing C * , ranging from seconds to tens of minutes, except for the NO 3 - CIMS where it is always on the order of seconds. Six different tubing materials were tested. Teflon, including PFA, FEP, and conductive PFA, performs better than metals and Nafion in terms of both delay time and transmission efficiency. Analogous to instrument responses, tubing delays increase as C * decreases, from less than a minute to >100 min . The delays caused by Teflon tubing vs. C * can be modeled using the simple chromatography model of Pagonis et al. (2017). The model can be used to estimate the equivalent absorbing mass concentration ( C w ) of each material, and to estimate delays under different flow rates and tubing dimensions. We also include time delay measurements from a series of small polar organic and inorganic analytes in PFA tubing measured by CIMS. Small polar molecules behave differently than larger organic ones, with their delays being predicted by their Henry's law constants instead of their C * , suggesting the dominance of partitioning to small amounts of water on sampling surfaces as a result of their polarity and acidity properties. PFA tubing has the best performance for gas-only sampling, while conductive PFA appears very promising for sampling S/IVOCs and particles simultaneously. The observed delays and low transmission both affect the quality of gas quantification, especially when no direct calibration is available. Improvements in sampling and instrument response are needed for fast atmospheric measurements of a wide range of S/IVOCs (e.g., by aircraft or for eddy covariance). These methods and results are also useful for more general characterization of surface–gas interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

COMPARATIVE ANALYSIS OF SELECTED EDDY CURRENT TRANSDUCERS FOR TITANIUM ALLOY EVALUATION

Titanium alloy based details due to their mechanical properties continue to be in extensive use in various structures (mainly aerospace, automotive and petro-chemical industrial applications). In this paper comparative study of various types of eddy current NDT transducers for testing titanium elements was done. Probes of absolute, differential and array configurations were constructed and analyzed. Two and three dimensional numerical analysis (FEM) were done in order to find the best type and configuration of the proposed transducers.

36 MATERIALS SCIENCE↗

Laser Driven Hydrothermal Processing (LDHP) for Rapid Dissolution of Glassy Nuclear Debris

Discovered in 2009 on the SLAB laser system at LLNL, Laser-Driven Hydrothermal Processing (LDHP) both spalls and transiently dissolves a wetted surface (e.g., rock, concrete, paint) when that surface is struck by a laser beam pulse under specific conditions. Previous projects have explored the application of LDHP to expediting sample dissolution for post-detonation nuclear forensics. Early results were very promising, indicating that this method could decrease material dissolution time by a factor of 10 or more. However, the large and complicated lasers previously used are impractical for this application. Under the R^3 venture we aimed to benchmark the LDHP capabilities of turn-key commercial off-the-shelf (COTS) lasers, and to establish how this process could be integrated into an analytical workflow for nuclear forensic analysis. We demonstrated that geological rock standards could be quickly processed into fine powder by LDHP followed by complete acid digestion in 15 minutes, without elemental fractionation that would skew analytical results. We determined that the COTS laser can be used for LDHP that could potentially reduce dissolution time for solid nuclear debris samples in post detonation nuclear forensics. One downside to this approach, however, is that the laser interactions are different with every material, so extensive method validation would be required for all likely material compositions. The LDHP processing rates of several materials were tested and determined to be favorable in the beginning with significant slowdown due to particulate scattering. This could be mitigated either by stopping and centrifuging the sample at specific intervals, or through design of a continuous solvent flow through mechanism.

36 MATERIALS SCIENCE↗

Influence of pre-hydriding and quench on embrittlement of E110 alloy under LOCA conditions

The aims of present work were to investigate the corrosion behavior and residual ductility of pre-hydrided E110 alloy under LOCA conditions including the influence of cooling rate. The fragments of unirradiated and pre-hydrided cladding (9,5*8,33 mm with a 10 mm length) were used as samples. The claddings were made from an E110 sponge based alloy (finish polishing). The hydrogen concentration varied from 5 (as received) to 800 wppm. As a result of pre-hydriding δ- hydrides of zirconium have been formed into cladding material. Corrosion tests were carried out at temperatures 1100 and 1200 C. degrees in a steam (80 mg/s) and argon (25 ml/s) mixture flow. The samples were cooled by 2 regimes: the first one is cooling in the cold zone of test facility with rate about 20 C. degrees/s, the second is cooling in the cold zone of test facility with rate about 20 C. degrees/s from test temperature to 800 C. degrees and quench by dropping in to the water. The change of a sample mass was determined as a difference between initial sample mass and its mass after oxidation. The mechanical tests of oxidized claddings in a diametrical direction were carried out with the use of a universal tension testing machine at a steady deformation rate of 1 mm/min at 135 C. degrees. The investigations have established the following. The initial concentration of hydrogen has no effects on the oxidation kinetics, while the oxidation kinetics are parabolic and the breakaway oxidation is not observed. The oxide films on cladding surfaces are black and shining. There are no cracks, visual spots and peelings. The residual ductility of oxidized samples decreases with the increase of hydrogen concentration. The residual ductility of slow cooled claddings is higher than residual ductility of quenched claddings. The limiting value of ECR (Equivalent Cladding Reacted) corresponding to ductile-brittle transition as function of initial hydrogen content was evaluated. The value of residual ductility 2% was used as a ductile-brittle threshold. The limiting value of ECR for as-received E110 alloy is 18% and it decreases slowly to 15% with hydrogen content rising to 350 wppm. At hydrogen content of about 350 - 400 wppm there is a rapid change of limiting value of ECR from 15% to 8 %. At hydrogen content from 400 to 800 wppm the limiting value of ECR decreases from 8% to 3%. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Expanded Use of ISOCS Characterization Techniques for WIPP Certification at the Idaho Clean-up Project - 19623

The Advanced Mixed Waste Treatment Project (AMWTP) has been retrieving, treating, characterizing, and shipping legacy Transuranic (TRU) waste for disposal since 2003 as part of the overall Idaho Cleanup Project (ICP) in support of the US Department of Energy. As the ICP has progressed, over 700 containers have been identified that cannot be successfully assayed using the current suite of non-destructive assay (NDA) instruments. To meet this challenge, Fluor Idaho, LLC, and Mirion Technologies (formerly Canberra Industries) have teamed to deploy the In-Situ Object Counting System (ISOCS) to supplement the current NDA capabilities. ISOCS has long been used in various radioactive waste management applications, but never has the ISOCS ability to perform intrinsic efficiency modeling of discrete waste containers been employed to characterize and certify TRU waste for disposal at the Waste Isolation Pilot Plant (WIPP), near Carlsbad, New Mexico. Since the primary disposal facility for this waste is the WIPP, the characterization processes for determining the quantity of radioactive material entrained in the waste are subject to WIPP Waste Acceptance Criteria (WAC) quality requirements and associated performance criteria. Until now, the Carlsbad Field Office (CBFO) WIPP-certified NDA equipment has utilized pre-defined efficiency calibrations for fixed geometries. However, due to the radioactive material content, activity levels, waste stream matrix, and/or the geometries of various size drums, boxes and other-odd-shaped containers or container integrity issues, it may not be suitable to characterize these containers with any of the existing WIPP-certified NDA equipment located at the AMWTP. Therefore, advanced technologies are needed to complete characterization of these problematic waste containers. The July 5, 2016 release of the WIPP WAC, DOE/WIPP-02-3122, Revision 8.0, Appendix A, 'Radioassay Requirements for Transuranic Waste,' was expanded to include several newer concepts such as American Society for Testing and Materials (ASTM) approved methods for efficiency-based calibrations and the use of mathematical computer modeling techniques for calibration. This change prompted AMWTP to pursue obtaining WIPP certification authority for expanded ISOCS techniques to deal with the remaining challenging waste containers and the development and implementation of Mirion's Figures of Merit (FOM) evaluations. These vital FOM evaluations enhance the ISOCS's modeling capabilities by optimizing the dynamic efficiency calibration for each object and reducing the assay's Total Measurement Uncertainty (TMU) budget. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An investigation to the effect of deformation-heat treatment cycle on the eutectic morphology and mechanical properties of a Thixocast A356 alloy

The influences of deformation, heat treatment temperature and holding time on morphology and size distribution of Si containing eutectic phases of Thixocast Al-7Si-0.4 Mg alloy were investigated. The novel thermo-mechanical treatment consisted of initial cold working practice followed by a solution heat treatment at 540 deg. C for durations ranging from 2 min to 120 min followed by water quenching. Optical and scanning electron microscopes were used to study the influence of process parameters on microstructure evolution. Also, final mechanical properties were investigated using hardness test. The results indicate that, under appropriate conditions it is possible to achieve an ultrafine grain microstructure with the eutectic Si fibers fragmented and spheroidized in the entire microstructure. It was also found that, an agglomeration of sphrodized particles occurs and is governed by Ostwald ripening mechanism.

36 MATERIALS SCIENCE↗

SU-E-T-373: Evaluation and Reduction of Contralateral Skin /subcutaneous Dose for Tangential Breast Irradiation

Purpose: Tangential breast irradiation is a standard treatment technique for breast cancer therapy. One aspect of dose delivery includes dose delivered to the skin caused by electron contamination. This effect is especially important for highly oblique beams used on the medical tangent where the electron contamination deposits dose on the contralateral breast side. This work aims to investigate and predict as well as define a method to reduce this dose during tangential breast radiotherapy. Methods: Analysis and calculation of breast skin and subcutaneous dose is performed using a Varian Eclipse planning system, AAA algorithm for 6MV x-ray treatments. Measurements were made using EBT3 Gafchromic film to verify the accuracy of planning data. Various materials were tested to assess their ability to remove electron contamination on the contralateral breast. Results: Results showed that the Varian Eclipse AAA algorithm could accurately estimate contralateral breast dose in the build-up region at depths of 2mm or deeper. Surface dose was underestimated by the AAA algorithm. Doses up to 12% of applied dose were seen on the contralateral breast surface and up to 9 % at 2mm depth. Due to the nature of this radiation, being mainly low energy electron contamination, a bolus material could be used to reduce this dose to less than 3%. This is accomplished by 10 mm of superflab bolus or by 1 mm of lead. Conclusion: Contralateral breast skin and subcutaneous dose is present for tangential breast treatment and has been measured to be up to 12% of applied dose from the medial tangent beam. This dose is deposited at shallow depths and is accurately calculated by the Eclipse AAA algorithm at depths of 2mm or greater. Bolus material placed over the contralateral can be used to effectively reduce this skin dose.

60 APPLIED LIFE SCIENCES↗

POTENTIAL USE OF ACTIVATED CARBON TO RECOVER TC-99 FROM 200 WEST AREA GROUNDWATER AS AN ALTERNATIVE TO MORE EXPENSIVE RESINS HANFORD SITE RICHLAND WASNINGTON

Recent treatability testing performed on groundwater at the 200-ZP-1 Operable Unit at the Hanford Site in Richland, Washington, has shown that Purolite{reg_sign} A530E resin very effectively removes Tc-99 from groundwater. However, this resin is expensive and cannot be regenerated. In an effort to find a less expensive method for removing Tc-99 from the groundwater, a literature search was performed. The results indicated that activated carbon may be used to recover technetium (as pertechnetate, TCO{sub 4}{sup -}) from groundwater. Oak Ridge National Laboratory used activated carbon in both batch adsorption and column leaching studies. The adsorption study concluded that activated carbon absorbs TCO{sub 4}{sup -} selectively and effectively over a wide range of pH values and from various dilute electrolyte solutions (< 0.01 molarity). The column leaching studies confirmed a high adsorption capacity and selectivity of activated carbon for TCO{sub 4}{sup -}. Since activated carbon is much less expensive than Purolite A530E resin, it has been determined that a more extensive literature search is warranted to determine if recent studies have reached similar conclusions, and, if so, pilot testing of 200-ZP-1 groundwater wi11 likely be implemented. It is possible that less expensive, activated carbon canisters could be used as pre-filters to remove Tc-99, followed by the use of the more expensive Purolite A530E resin as a polishing step.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of Concepts for Mulitiple Application Thermal Reactor for Irradiation eXperiments (MATRIX)

The Advanced Test Reactor (ATR) is a high power density test reactor specializing in fuel and materials irradiation. For more than 45 years, the ATR has provided irradiations of materials and fuels testing along with radioisotope production. Originally operated primarily in support of the Offcie of Naval Reactors (NR), the mission has gradually expanded to cater to other customers, such as the DOE Office of Nuclear Energy (NE), private industry, and universities. Unforeseen circumstances may lead to the decommissioning of ATR, thus leaving the U.S. Government without a large-scale materials irradiation capability to meet the needs of its nuclear energy and naval reactor missions. In anticipation of this possibility, work was performed under the Laboratory Directed Research and Development (LDRD) program to investigate test reactor concepts that could satisfy the current missions of the ATR along with an expanded set of secondary missions. This work can be viewed as an update to a project from the 1990’s called the Broad Application Test Reactor (BATR). In FY 2012, a survey of anticipated customer needs was performed, followed by analysis of the original BATR concepts with fuel changed to low-enriched uranium. Departing from these original BATR designs, four concepts were identified for further analysis in FY2013. The project informally adopted the acronym MATRIX (Multiple-Application Thermal Reactor for Irradiation eXperiments). This report discusses analysis of the four MATRIX concepts along with a number of variations on these main concepts. Designs were evaluated based on their satisfaction of anticipated customer requirements and the “Cylindrical” variant was selected for further analysis of options. This downselection should be considered preliminary and the backup alternatives should include the other three main designs. The baseline Cylindrical MATRIX design is expected to be capable of higher burnup than the ATR (or longer cycle length given a particular batch scheme). The volume of test space in IPTs is larger in MATRIX than in ATR with comparable magnitude of neutron flux. In addition to the IPTs, the Cylindrical MATRIX concept features test spaces at the centers of fuel assemblies where very high fast flux can be achieved. This magnitude of fast flux is similar to that achieved in the ATR A-positions, however, the available volume having these conditions is greater in the MATRIX design than in the ATR. From the analyses performed in this work, it appears that the Cylindrical MATRIX design can be designed to meet the anticipated needs of the ATR replacement reactor. However, this statement must be qualified by acknowledging that this design is quite immature, and therefore any requirements currently met must be re-evaluated as the design matures. Also, some of the requirements were not strictly met, but are believed to be achievable once features to be added later are designed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of a pepper-pot emittance meter for diagnostics of low-energy multiply charged heavy ion beams extracted from an ECR ion source

Several fluorescent materials were tested for use in the imaging screen of a pepper-pot emittance meter that is suitable for investigating the beam dynamics of multiply charged heavy ions extracted from an ECR ion source. SiO{sub 2} (quartz), KBr, Eu-doped CaF{sub 2}, and Tl-doped CsI crystals were first irradiated with 6.52-keV protons to determine the effects of radiation damage on their fluorescence emission properties. For such a low-energy proton beam, only the quartz was found to be a suitable fluorescent material, since the other materials suffered a decay in fluorescence intensity with irradiation time. Subsequently, quartz was irradiated with heavy {sup 12}C{sup 4+}, {sup 16}O{sup 4+}, and {sup 40}Ar{sup 11+} ions, but it was found that the fluorescence intensity decreased too rapidly to measure the emittance of these heavy-ion beams. These results suggest that a different energy loss mechanism occurs for heavier ions and for protons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Re-establishment of Sandia National Labs super-critical carbon dioxide testing autoclave capability for exposure of metal alloys and polymers (Level 4 Milestone Report)

The sCO 2 system located in 916/160A, Sandia National Laboratories, CA, was constructed in 2014, for testing of materials in the presence of supercritical carbon dioxide (sCO 2 ) at high pressures (up to 3500 psi) and temperatures (up to 650°C). The basic design of the system consists of a thermally insulated IN625 autoclave, a high-pressure supercritical CO 2 compressor, autoclave heaters, temperature controllers, gas manifold, and temperature and pressure diagnostics. This system was modified in 2016 (sCO 2 compressor was removed) to enable corrosion studies with metal alloys in gaseous CO 2 at lower pressure (up to 300 psi) at 500°C. The capability was not used much afterwards until 2020, when preliminary tests using this capability (again without the supercritical CO 2 compressor) involved the exposure of fatigue and tensile specimens of HN 230 and 800H alloys to CO 2 gas for 168 hours in gaseous CO 2 . Using this capability, we finished experiments with low pressure (450 psi/ 3 MPa), high temperature (650°C) exposure of fatigue and tensile specimens of HN 230 and 800H alloys to CO 2 gas for 168 hours. The data from these experiments will be compared to that gathered from experiments performed in 2020 using the tube furnace and presented in a future report. It is to be noted that the tube furnace experiments ran 500-1500 hours, unlike the 168 hours of exposure in the recent experiment. This can help validate the use of the sCO 2 autoclave for both CO 2 and sCO 2 experiments.

36 MATERIALS SCIENCE↗

Correlations Between Crystal Defects and Performance of CdZnTe Detectors

Poor crystallinity remains a major problem affecting the availability and cost of CdZnTe (CZT) detectors. Point defects are responsible for small gradual charge loss and correlated with the electron clouds' drift times, which allows electronic correction of the output signals to achieve high spectral-resolution even with large-volume CZT detectors. In contrast, extended defects causes significant charge losses, which typically are uncorrelated, and, thus, result in much greater fluctuations of the output signals that cannot be corrected. Although extended defects do not affect all the interaction events, their fraction rapidly increases with the crystal's thickness and volume. In this paper, we summarize our recent results from testing CZT material and detectors that emphasize the particular roles of two types of extended defects, and their contributions to the device's overall performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

JCESR Scientific Sprints – Better Polymers for Better Batteries

Argonne National Laboratory leads the Joint Center for Energy Storage Research (JCESR), a major collaborative research partnership with the goal of developing next-generation energy storage technologies. JCESR supplements its traditional project management approach with scientific “Sprints.” The Sprint described in this video involved a multidisciplinary team from Argonne, the University of Illinois at Urbana-Champaign, Massachusetts Institute of Technology, and the University of Michigan. As they studied how polymers in solution can react electrochemically to store energy, the team solved a crucial battery problem: “crossover,” which is caused by molecules mixing together when they should not, resulting in reduced performance. Many possible materials were tested, and a set of candidate polymers were chosen that are stable, cheap to make, and suitable for conditions required in batteries. The collaboration allowed timely development that would have taken much longer had the groups been working independently.

25 ENERGY STORAGE↗

Measurement of carrier lifetime in micron-scaled materials using resonant microwave circuits

The measurement of minority carrier lifetimes is vital to determining the material quality and operational bandwidth of a broad range of optoelectronic devices. Typically, these measurements are made by recording the temporal decay of a carrier-concentration-dependent material property following pulsed optical excitation. Such approaches require some combination of efficient emission from the material under test, specialized collection optics, large sample areas, spatially uniform excitation, and/or the fabrication of ohmic contacts, depending on the technique used. In contrast, here we introduce a technique that provides electrical readout of minority carrier lifetimes using a passive microwave resonator circuit. We demonstrate >10 5 improvement in sensitivity, compared with traditional photoemission decay experiments and the ability to measure carrier dynamics in micron-scale volumes, much smaller than is possible with other techniques. The approach presented is applicable to a wide range of 2D, micro-, or nano-scaled materials, as well as weak emitters or non-radiative materials.

36 MATERIALS SCIENCE↗