Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material point method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Molecular dynamics simulations of radiation cascade evolution near cellular dislocation structures in additively manufactured stainless steels

The dislocation dense cellular structures observed in additively manufactured (AM) stainless steels can allow these materials to have enhanced strength and ductility compared to conventionally manufactured materials. Effective design of radiation resistant materials often necessitates creating microstructures containing of a high density of dislocations that act as sinks for radiation induced defects. This work uses molecular dynamics simulations to study the impact of pre-existing defects on radiation damage in stainless steel 316L fabricated by the laser powder bed fusion process. The evolution of synthetically generated dislocations in a crystal system in response to multiple radiation collision cascades suggest that dislocation dense regions reduce the probability of surviving point defects forming clusters. This finding seems to result from the dislocation cores’ ability to absorb point defects, thereby limiting the formation of clusters during the recombination phase. However, after successive cascades, the ability of the dislocation entanglement to prevent defect formation is diminished and defect cluster formation trends to an equilibrium. Accordingly, it is hypothesized that in an experimental setting the dislocation cells will initially act as neutral sinks for point defects, potentially delaying the onset of radiation damage effects; but, these structures will be degraded due to radiation-enhanced diffusion and lose their effectiveness at doses above 1.5–2 displacements per atom. Nevertheless, the ability to produce complex and feature-specific microstructures suggests promise for the design of radiation tolerant materials using AM methods.

36 MATERIALS SCIENCE↗

A photoactive titanate with a stereochemically active Sn lone pair: Electronic and crystal structure of Sn{sub 2}TiO{sub 4} from computational chemistry

TiO{sub 2} remains the most widely studied metal oxide for photocatalytic reactions. The standard approach to reduce the band gap of titania, for increasing the absorption of visible light, is anion modification. For example the formation of an oxynitride compound, where the nitrogen 2p states decrease the binding energy of the valence band. We demonstrate that cation modification can produce a similar effect through the formation of a ternary oxide combining Ti and an ns{sup 2} cation, Sn(II). In Sn{sub 2}TiO{sub 4}, the underlying Ti 3d conduction states remain largely unmodified and an electronic band gap of 2.1 eV (590 nm) is predicted by hybrid density functional theory. Our analysis indicates a strong potential for Sn{sub 2}TiO{sub 4} in visible-light driven photocatalysis, which should prove superior to the alternative (SnO{sub 2}){sub 1-x}(TiO{sub 2}){sub x} solid-solution. - Graphical abstract: Sn{sub 2}TiO{sub 4} is predicted to be a semiconductor with potential for bipolar conductivity and visible-light photocatalysis. Highlights: Black-Right-Pointing-Pointer Tin titanate adopts the Pb{sub 3}O{sub 4} crystal structure with a sterically active Sn(II) lone pair. Black-Right-Pointing-Pointer Tin titanate is thermodynamically stable with respect to TiO{sub 2} and SnO. Black-Right-Pointing-Pointer Tin titanate is predicted have a band gap of 590 nm, ideal for photocatalytic applications.

36 MATERIALS SCIENCE↗

Score-based denoising for atomic structure identification

We propose an effective method for removing thermal vibrations that complicate the task of analyzing complex dynamics in atomistic simulation of condensed matter. Our method iteratively subtracts thermal noises or perturbations in atomic positions using a denoising score function trained on synthetically noised but otherwise perfect crystal lattices. The resulting denoised structures clearly reveal underlying crystal order while retaining disorder associated with crystal defects. Purely geometric, agnostic to interatomic potentials, and trained without inputs from explicit simulations, our denoiser can be applied to simulation data generated from vastly different interatomic interactions. The denoiser is shown to improve existing classification methods, such as common neighbor analysis and polyhedral template matching, reaching perfect classification accuracy on a recent benchmark dataset of thermally perturbed structures up to the melting point. Demonstrated here in a wide variety of atomistic simulation contexts, the denoiser is general, robust, and readily extendable to delineate order from disorder in structurally and chemically complex materials.

36 MATERIALS SCIENCE↗

Characterization of a semicrystalline polyimidesulfone powder

A semicrystalline polyimidesulfone (PISO2) material has been synthesized and characterized. Characterization methods include thermal analysis by DSC and measurements of inherent viscosities, wide-angle X-ray diffraction, and viscoelasticity. The melt flow properties of both amorphous and semicrystalline samples were also investigated by means of a parallel plate plastometer. This material was found to be not readily recrystallizable at temperatures above its initial peak melting point of 225 C, when compared to other crystalline thermoplastics. This semicrystalline PISO2 demonstrated a flow about 5 times greater than the amorphous one as characterized by the plastometer. Such enhanced melt flow properties could be of great benefit in the adhesive and composite lamination processes.

Hou, T. H.↗

Structural analysis of an NDE-inspected carbon-carbon component

In this research, it is demonstrated that the integration of nondestructive evaluation with the finite element method (a quantitative NDE/FEM approach) can be used for analysis and behavior prediction of advanced materials, such as fiber composites, after processing and during in-service testing. First, stress, strain, and energy data were calculated by the finite element method for square plates with a 10 percent difference in the material properties between specified segments, i.e., between the center and the outside section or between two halves of the plate. This demonstrated the efficiency of the method in predicting variations in the structural behavior based on small material property differences. Then, finite element analyses and actual axial compression tests were performed on a Space Shuttle brake stator made from woven carbon-carbon composites. The material properties used in the numerical modeling of the stator were previously characterized at a large number of points on the component by quantitative NDE-procedures, i.e., ultrasonics and radiography. The results from the experimental compressive loading tests were used to verify the NDE/FEM results. Good agreement was found for most parameters.

Striz, A. G.↗

Nondestructive evaluation of a ceramic matrix composite material

Monolithic ceramic materials have proven their usefulness in many applications, yet, their potential for critical structural applications is limited because of their sensitivity to small imperfections. To overcome this extreme sensitivity to small imperfections, ceramic matrix composite materials have been developed that have the ability to withstand some distributed damage. A borosilicate glass reinforced with several layers of silicon-carbide fiber mat has been studied. Four-point flexure and tension tests were performed not only to determine some of the material properties, but also to initiate a controlled amount of damage within each specimen. Acousto-ultrasonic (AU) measurements were performed periodically during mechanical testing. This paper will compare the AU results to the mechanical test results and data from other nondestructive methods including acoustic emission monitoring and X-ray radiography. It was found that the AU measurements were sensitive to the damage that had developed within the material.

Grosskopf, Paul P.↗

Method and apparatus for maximizing throughput of indirectly heated rotary kilns

An apparatus and method for achieving improved throughput capacity of indirectly heated rotary kilns used to produce pyrolysis products such as shale oils or coal oils that are susceptible to decomposition by high kiln wall temperatures is disclosed. High throughput is achieved by firing the kiln such that optimum wall temperatures are maintained beginning at the point where the materials enter the heating section of the kiln and extending to the point where the materials leave the heated section. Multiple high velocity burners are arranged such that combustion products directly impact on the area of the kiln wall covered internally by the solid material being heated. Firing rates for the burners are controlled to maintain optimum wall temperatures.

47 OTHER INSTRUMENTATION↗

Method and apparatus for maximizing throughput of indirectly heated rotary kilns

An apparatus and method for achieving improved throughput capacity of indirectly heated rotary kilns used to produce pyrolysis products such as shale oils or coal oils that are susceptible to decomposition by high kiln wall temperatures is disclosed. High throughput is achieved by firing the kiln such that optimum wall temperatures are maintained beginning at the point where the materials enter the heating section of the kiln and extending to the point where the materials leave the heated section. Multiple high velocity burners are arranged such that combustion products directly impact on the area of the kiln wall covered internally by the solid material being heated. Firing rates for the burners are controlled to maintain optimum wall temperatures.

01 COAL, LIGNITE, AND PEAT↗

Magnetoelectric coupling study in multiferroic Pb(Fe{sub 0.5}Nb{sub 0.5})O{sub 3} ceramics through small and large electric signal standard measurements

Multifunctional multiferroic materials such as the single phase compound Pb(Fe{sub 0.5}Nb{sub 0.5})O{sub 3} (PFN), where ferroelectric and antiferromagnetic order coexist, are very promising and have great interest from the academic and technological points of view. In this work, coupling of the ferroelectric and magnetic moments is reported. For this study, a combination of the small signal response using the impedance spectroscopy technique and the electromechanical resonance method with the large signal response through standard ferroelectric hysteresis measurement, has been used with and without an applied magnetic field. The measurements to determine the electrical properties of the ceramic were performed as functions of the bias and poling electric fields. A simultaneous analysis of the complex dielectric constant {epsilon}-tilde, impedance Z-tilde, electric modulus M-tilde, admittance Y-tilde, and the electromechanical parameters and coupling factors is presented. The results are correlated with a previous study of structural, morphological, small signal dielectric frequency-temperature response, and the ferroelectric hysteretic, magnetic and magnetodielectric behaviors. The observed shifts of the resonance and antiresonance frequency values can be associated with change of the ferroelectric domain size favored by the readjustment of the oxygen octahedron when the magnetic field is applied. From P-E hysteresis loops obtained without and with an external applied magnetic field, a dc magnetoelectric coupling effect with maximum value of 4 kV/cm T (400 mV/cm Oe) was obtained.

36 MATERIALS SCIENCE↗

Optimizing non-Pb radiation shielding materials using bilayers

Purpose: The objective of this study was to demonstrate that the weight of non-Pb radiation shielding materials can be minimized by structuring the material as a bilayer composed of different metal-powder-embedded elastomer layers. Methods: Measurements and Monte Carlo (MC) calculations were performed to study the attenuation properties of several non-Pb metal bilayers over the x-ray energy range 30-150 keV. Metals for the layers were chosen on the basis of low cost, nontoxicity, and complementary photoelectric absorption characteristics. The EGSnrc user code cavity.cpp was used to calculate the resultant x-ray fluence spectra after attenuation by these metal layers. Air kerma attenuation was measured using commercially manufactured metal/elastomer test layers. These layers were irradiated using the primary standard calibration beams at the Institute for National Measurement Standards in Ottawa, Canada utilizing the six x-ray beam qualities recommended in the German Standard DIN 6857. Both the measurements and the calculations were designed to approximate surface irradiation as well as penetrating radiation at 10 mm depth in soft tissue. The MC modeling point and the position of the measurement detector for surface irradiation were both directly against the downstream face of the attenuating material, as recommended in DIN 6857. Results: The low-Z upstream/high-Z downstream ordering of the metal bilayers provided substantially more attenuation than the reverse order. Optimal percentages of each metal in each bilayer were determined for each x-ray radiation beam quality. Conclusions: Depending on the x-ray quality, appropriate choices of two complementary metal-embedded elastomer layers can decrease the weight of radiation shielding garments by up to 25% compared to Pb-based elastomer garments while providing equivalent attenuation.

61 RADIATION PROTECTION AND DOSIMETRY↗

The removal of Zn2+, Pb2+, and As(V) ions by lime activated fly ash and valorization of the exhausted adsorbent

This study focuses on the use of raw fly ash (FA) and modified fly ash – activated by lime (MFA), as effective and low-cost adsorbents for the removal of heavy metals (Zn2+, Pb2+and As(V)), followed by the revalorization of the exhausted adsorbent. The granulometric, elemental analysis, point of zero charge (pHPZC), radiochemical and structural characterization were conducted using X-ray diffraction (XRD), Brunauer–Emmett–Teller (BET), scanning electron microscopy (SEM), Fourier transform infrared (FTIR) and gamma spectrometry techniques. The optimal conditions and key factors influencing the adsorption process were assessed using the response surface method (RSM). The adsorption capacity of the MFA adsorbent for Zn2+, Pb2+and As(V) removal, calculated by the Langmuir model, was found to be 33.13, 26.06, and 29.71 mg g−1, respectively. The kinetic and thermodynamic parameters indicated that the adsorption process is spontaneous and endothermic. Due to their low desorption potential of the exhausted adsorbents, their effective reuse was established to be feasible. For this reason, the valorization of this material as an additive in construction materials was thereafter studied, where testing its toxicity leaching (TCLP) as well as the mechanical properties of construction material containing exhausted MFA confirmed its safe use. Hence, this study points to a possible “two-in-one” reuse of coal ash, initially as an adsorbent and later as an additive in a construction material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Acoustic travel time gauges for in-situ determination of pressure and temperature in multi-anvil apparatus

In this study, we developed a new method for in-situ pressure determination in multi-anvil, high-pressure apparatus using an acoustic travel time approach within the framework of acoustoelasticity. The ultrasonic travel times of polycrystalline Al{sub 2}O{sub 3} were calibrated against NaCl pressure scale up to 15 GPa and 900 °C in a Kawai-type double-stage multi-anvil apparatus in conjunction with synchrotron X-radiation, thereby providing a convenient and reliable gauge for pressure determination at ambient and high temperatures. The pressures derived from this new travel time method are in excellent agreement with those from the fixed-point methods. Application of this new pressure gauge in an offline experiment revealed a remarkable agreement of the densities of coesite with those from the previous single crystal compression studies under hydrostatic conditions, thus providing strong validation for the current travel time pressure scale. The travel time approach not only can be used for continuous in-situ pressure determination at room temperature, high temperatures, during compression and decompression, but also bears a unique capability that none of the previous scales can deliver, i.e., simultaneous pressure and temperature determination with a high accuracy (±0.16 GPa in pressure and ±17 °C in temperature). Therefore, the new in-situ Al{sub 2}O{sub 3} pressure gauge is expected to enable new and expanded opportunities for offline laboratory studies of solid and liquid materials under high pressure and high temperature in multi-anvil apparatus.

36 MATERIALS SCIENCE↗

Understanding and reducing deleterious defects in the metastable alloy GaAsBi

Technological applications of novel metastable materials are frequently inhibited by abundant defects residing in these materials. Using first-principles methods, we investigate the defect thermodynamics and phase segregation in the technologically important metastable alloy GaAsBi. Our calculations predict defect energy levels in good agreement with those from numerous previous experiments and clarify the defect structures giving rise to these levels. We find that vacancies in some charge states become metastable or unstable with respect to antisite formation, and this instability is a general characteristic of zincblende semiconductors with small ionicity. The dominant point defects that degrade the electronic and optical performances are predicted to be As Ga , Bi Ga , As Ga +Bi As , Bi Ga +Bi As , V Ga and V Ga +Bi As , of which the first four and last two defects are minority-electron and minority-hole traps, respectively. V Ga is also observed to have a critical role in controlling metastable Bi supersaturation by mediating Bi diffusion and clustering. To reduce the influences of these deleterious defects, we suggest shifting the growth away from an As-rich condition and/or using hydrogen passivation to reduce the minority-carrier traps. In conclusion, we expect this work to aid in the applications of GaAsBi for novel electronic and optoelectronic devices and to illuminate the control of deleterious defects in other metastable materials.

36 MATERIALS SCIENCE↗

Four-Week Neoadjuvant Intensity-Modulated Radiation Therapy With Concurrent Capecitabine and Oxaliplatin in Locally Advanced Rectal Cancer Patients: A Validation Phase II Trial

Purpose: To validate tolerance and pathological complete response rate (pCR) of a 4-week preoperative course of intensity-modulated radiation therapy (IMRT) with concurrent capecitabine and oxaliplatin (CAPOX) in patients with locally advanced rectal cancer. Methods and Materials: Patients with T3 to T4 and/or N+ rectal cancer received preoperative IMRT (47.5 Gy in 19 fractions) with concurrent capecitabine (825 mg/m{sup 2} b.i.d., Monday to Friday) and oxaliplatin (60 mg/m{sup 2} on Days 1, 8, and 15). Surgery was scheduled 4 to 6 weeks after the completion of chemoradiation. Primary end points were toxicity and pathological response rate. Local control (LC), disease-free survival (DFS), and overall survival (OS) were also analyzed. Results: A total of 100 patients were evaluated. Grade 1 to 2 proctitis was observed in 73 patients (73%). Grade 3 diarrhea occurred in 9% of the patients. Grade 3 proctitis in 18% of the first 50 patients led to reduction of the dose per fraction to 47.5 Gy in 20 treatments. The rate of Grade 3 proctitis decreased to 4% thereafter (odds ratio, 0.27). A total of 99 patients underwent surgery. A pCR was observed in 13% of the patients, major response (96-100% of histological response) in 48%, and pN downstaging in 78%. An R0 resection was performed in 97% of the patients. After a median follow-up of 55 months, the LC, DFS, and OS rates were 100%, 84%, and 87%, respectively. Conclusions: Preoperative CAPOX-IMRT therapy (47.5 Gy in 20 fractions) is feasible and safe, and produces major pathological responses in approximately 50% of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Incidental Prophylactic Nodal Irradiation and Patterns of Nodal Relapse in Inoperable Early Stage NSCLC Patients Treated With SBRT: A Case-Matched Analysis

Purpose: Reported rates of non-small cell lung cancer (NSCLC) nodal failure following stereotactic body radiation therapy (SBRT) are lower than those reported in the surgical series when matched for stage. We hypothesized that this effect was due to incidental prophylactic nodal irradiation. Methods and Materials: A prospectively collected group of medically inoperable early stage NSCLC patients from 2004 to 2010 was used to identify cases with nodal relapses. Controls were matched to cases, 2:1, controlling for tumor volume (ie, same or greater) and tumor location (ie, same lobe). Reference (normalized to equivalent dose for 2-Gy fractions [EQD2]) point doses at the ipsilateral hilum and carina, demographic data, and clinical outcomes were extracted from the medical records. Univariate conditional logistical regression analyses were performed with variables of interest. Results: Cases and controls were well matched except for size. The controls, as expected, had larger gross tumor volumes (P=.02). The mean ipsilateral hilar doses were 9.6 Gy and 22.4 Gy for cases and controls, respectively (P=.014). The mean carinal doses were 7.0 Gy and 9.2 Gy, respectively (P=.13). Mediastinal nodal relapses, with and without ipsilateral hilar relapse, were associated with mean ipsilateral hilar doses of 3.6 Gy and 19.8 Gy, respectively (P=.01). The conditional density plot appears to demonstrate an inverse dose-effect relationship between ipsilateral hilar normalized total dose and risk of ipsilateral hilar relapse. Conclusions: Incidental hilar dose greater than 20 Gy is significantly associated with fewer ipsilateral hilar relapses in inoperable early stage NSCLC patients treated with SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Results From the Imaging and Radiation Oncology Core Houston's Anthropomorphic Phantoms Used for Proton Therapy Clinical Trial Credentialing

Purpose: The purpose of this study was to summarize the findings of anthropomorphic proton phantom irradiations analyzed by the Imaging and Radiation Oncology Core Houston QA Center (IROC Houston). Methods and Materials: A total of 103 phantoms were irradiated by proton therapy centers participating in clinical trials. The anthropomorphic phantoms simulated heterogeneous anatomy of a head, liver, lung, prostate, and spine. Treatment plans included those for scattered, uniform scanning, and pencil beam scanning beam delivery modalities using 5 different treatment planning systems. For every phantom irradiation, point doses and planar doses were measured using thermoluminescent dosimeters (TLD) and film, respectively. Differences between measured and planned doses were studied as a function of phantom, beam delivery modality, motion, repeat attempt, treatment planning system, and date of irradiation. Results: The phantom pass rate (overall, 79%) was high for simple phantoms and lower for phantoms that introduced higher levels of difficulty, such as motion, multiple targets, or increased heterogeneity. All treatment planning systems overestimated dose to the target, compared to TLD measurements. Errors in range calculation resulted in several failed phantoms. There was no correlation between treatment planning system and pass rate. The pass rates for each individual phantom are not improving over time, but when individual institutions received feedback about failed phantom irradiations, pass rates did improve. Conclusions: The proton phantom pass rates are not as high as desired and emphasize potential deficiencies in proton therapy planning and/or delivery. There are many areas for improvement with the proton phantom irradiations, such as treatment planning system dose agreement, range calculations, accounting for motion, and irradiation of multiple targets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observer Evaluation of a Metal Artifact Reduction Algorithm Applied to Head and Neck Cone Beam Computed Tomographic Images

Purpose and Objectives: To quantify, through an observer study, the reduction in metal artifacts on cone beam computed tomographic (CBCT) images using a projection-interpolation algorithm, on images containing metal artifacts from dental fillings and implants in patients treated for head and neck (H&N) cancer. Methods and Materials: An interpolation-substitution algorithm was applied to H&N CBCT images containing metal artifacts from dental fillings and implants. Image quality with respect to metal artifacts was evaluated subjectively and objectively. First, 6 independent radiation oncologists were asked to rank randomly sorted blinded images (before and after metal artifact reduction) using a 5-point rating scale (1 = severe artifacts; 5 = no artifacts). Second, the standard deviation of different regions of interest (ROI) within each image was calculated and compared with the mean rating scores. Results: The interpolation-substitution technique successfully reduced metal artifacts in 70% of the cases. From a total of 60 images from 15 H&N cancer patients undergoing image guided radiation therapy, the mean rating score on the uncorrected images was 2.3 ± 1.1, versus 3.3 ± 1.0 for the corrected images. The mean difference in ranking score between uncorrected and corrected images was 1.0 (95% confidence interval: 0.9-1.2, P<.05). The standard deviation of each ROI significantly decreased after artifact reduction (P<.01). Moreover, a negative correlation between the mean rating score for each image and the standard deviation of the oral cavity and bilateral cheeks was observed. Conclusion: The interpolation-substitution algorithm is efficient and effective for reducing metal artifacts caused by dental fillings and implants on CBCT images, as demonstrated by the statistically significant increase in observer image quality ranking and by the decrease in ROI standard deviation between uncorrected and corrected images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Method for measuring multiple scattering corrections between liquid scintillators

In this study, a time-of-flight method is proposed to experimentally quantify the fractions of neutrons scattering between scintillators. An array of scintillators is characterized in terms of crosstalk with this method by measuring a californium source, for different neutron energy thresholds. The spectral information recorded by the scintillators can be used to estimate the fractions of neutrons multiple scattering. With the help of a correction to Feynman's point model theory to account for multiple scattering, these fractions can in turn improve the mass reconstruction of fissile materials under investigation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗