Search NASA⌕ Search

SEARCH · Search NASA

Results for “MicroED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Structural hysteresis in dragline spider silks induced by supercontraction: an X-ray fiber micro-diffraction study

Interaction with water causes shrinkage and significant changes in the structure of spider dragline silks, which has been referred to as supercontraction in the literature. Preferred orientation or alignment of protein chains with respect to the fiber axis is extensively changed during this supercontraction process. Synchrotron X-ray micro-fiber diffraction experiments have been performed on Nephila clavipes and Argiope aurantia major and minor ampullate dragline spider fibers in the native dry, contracted (by immersion in water) and restretched (from contracted) states. Changes in the orientation of β-sheet nanocrystallites and the oriented component of the amorphous network have been determined from wide-angle X-ray diffraction patterns. While both the crystalline and amorphous components lose preferred orientation on wetting with water, the nano-crystallites regain their orientation on wet-restretching, whereas the oriented amorphous components only partially regain their orientation. Dragline major ampullate silks in both the species contract more than their minor ampullate silks.

36 MATERIALS SCIENCE↗

High-rate in-plane micro-supercapacitors scribed onto photo paper using in situ femtolaser-reduced graphene oxide/Au nanoparticle microelectrodes

Direct laser-reduction of graphene oxide (GO), as a lithography-free approach, has been proven effective in manufacturing in-plane micro-supercapacitors (MSCs) with fast ion diffusion. However, the power density and the charge/discharge rate are still limited by the relatively low conductivity of electrodes. Here, we report a facile approach by exploiting femtolaser in situ reduction of the hydrated GO and chloroauric acid (HAuCl 4 ) nanocomposite simultaneously, which incorporates both the patterning of rGO electrodes and the fabrication of Au current collectors in a single step. These flexible MSCs boast achievements of one-hundred fold increase in electrode conductivities of up to 1.1 × 10 6 S m –1 , which provide superior rate capability (50% for the charging rate increase from 0.1 V s –1 to 100 V s –1 ), sufficiently high frequency responses (362 Hz, 2.76 ms time constant), and large specific capacitances of 0.77 mF cm –2 (17.2 F cm –3 for volumetric capacitance) at 1 V s –1 , and 0.46 mF cm –2 (10.2 F cm –3 ) at 100 V s –1 . The use of photo paper substrates enables the flexibility of this fabrication protocol. Moreover, proof-of-concept 3D MSCs are demonstrated with enhanced areal capacitance (up to 3.84 mF cm –2 at 1 V s –1 ) while keeping high rate capabilities. As a result, this prototype of all solid-state MSCs demonstrates the broad range of potentials of thin-film based energy storage device applications for flexible, portable, and wearable electronic devices that require a fast charge/discharge rate and high power density.

36 MATERIALS SCIENCE↗

Design of a multi-functional gel polymer electrolyte with a 3D compact stacked polymer micro-sphere matrix for high-performance lithium metal batteries

We report lithium metal batteries (LMBs) are considered as promising high energy density batteries. However, they still suffer from poor cyclability due to the instability of solid electrolyte interphases (SEIs) and Li dendrite issues. Herein, a novel 3D densely packed multifunctional crosslinked gel polymer electrolyte (PHGPE) has been synthesized by in situ copolymerization of pentaerythritol tetraacrylate and 2-hydroxyethyl acrylate in a liquid electrolyte via a thermal initiation method. Due to intermolecular hydrogen bonding in the frameworks, the PHGPE exhibits a 3D compact-stacked and crosslinked micro-sphere structure, which benefits the construction of homogeneous Li + flux, enabling uniform Li plating/stripping and formation of robust SEIs onto the lithium electrode. Benefiting from the above advantages, symmetric Li cells in the PHGPE deliver excellent cyclabilities of 6000 h at a current density of 1 mA cm -2 (1 mA h cm -2 ) and 7700 h at 0.5 mA cm -2 (2 mA h cm -2 ). Moreover, the PHGPE has such a wide electrochemical window that it is compatible with both high-voltage LiNi 0.8 Co 0.1 Mn 0.1 O 2 and sulfur cathodes to realize long cycle life. Additionally, a LiFePO 4 based pouch size LMB also presents promising performance. Therefore, this study of the PHGPE has opened a new avenue for high-performance LMBs with excellent versatility and practicality.

25 ENERGY STORAGE↗

Spin dynamics of [1,2- 13 C 2 ]pyruvate hyperpolarization by parahydrogen in reversible exchange at micro Tesla fields

Hyperpolarization of 13 C-pyruvate via Signal Amplification By Reversible Exchange (SABRE) is an important recent discovery because of both the relative simplicity of hyperpolarization and the central biological relevance of pyruvate as a biomolecular probe for in vitro or in vivo studies. Here, we analyze the [1,2- 13 C 2 ]pyruvate-SABRE spin system and its field dependence theoretically and experimentally. We provide first-principles analysis of the governing 4-spin dihydride- 13 C 2 Hamiltonian and numerical spin dynamics simulations of the 7-spin dihydride- 13 C 2 –CH 3 system. Furthermore, the analytical and the numerical results are compared to matching systematic experiments. With these methods we unravel the observed spin state mixing of singlet states and triplet states at microTesla fields and we also analyze the dynamics during transfer from micro-Tesla field to high field for detection to understand the resulting spectra from the [1,2- 13 C 2 ]pyruvate-SABRE system.

13C pyruvate↗

Systematic improvement of redox potential calculation of Fe(III)/Fe(II) complexes using a three-layer micro-solvation model

Electrochemical transformations of metal ions in aqueous media are challenging to model accurately due to the dynamic solvation structure surrounding ions at different charge states. Predictive modeling at the atomistic scale is essential for understanding these solvation architectures but is often computationally prohibitive. In this contribution, we present a simple, fast, and accurate three-layer micro-solvation model to evaluate the redox potential of metal ions in aqueous solutions. Our model, developed and validated for Fe 3+ /Fe 2+ redox potentials, combines the DFT-based geometry optimizations of the octahedral Fe complex with two layers of explicit water molecules to capture solute–solvent interactions and an implicit solvation model to account for bulk solvent effects. This approach yields accurate predictions for Fe 3+ /Fe 2+ redox potentials in water, achieving errors of 0.02 V with ωB97X-V, 0.01 V with ωB97X-D3, 0.04 V with ωB97M-V, and 0.02 V with B3LYP-D3 functionals. We further demonstrate the generality of our model by applying it to additional metal complexes, including the challenging Fe(CN) 6 3−/4− system, where our model successfully achieves close agreement with experimental values, with an error of 0.07 V and an average error of 0.21 V for all five systems. In summary, the presented simple solvation model has broad applicability and potential for enhancing computational efficiency in redox potential predictions across various chemical and industrial processes of metal ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High temperature superconductor micro-superconducting-quantum-interference-device magnetometer for magnetization measurement of a microscale magnet

We have developed a high temperature superconductor (HTS) micrometer-sized dc superconducting quantum interference device (SQUID) magnetometer for high field and high temperature operation. It was fabricated from YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} of 92 nm in thickness with photolithography techniques to have a hole of 4x9 {mu}m{sup 2} and 2 {mu}m wide grain boundary Josephson junctions. Combined with a three dimensional magnetic field coil system, the modulation patterns of critical current I{sub c} were observed for three different field directions. They were successfully used to measure the magnetic properties of a molecular ferrimagnetic microcrystal (23x17x13 {mu}m{sup 3}), [Mn{sub 2}(H{sub 2}O){sub 2}(CH{sub 3}COO)][W(CN){sub 8}]{center_dot}2H{sub 2}O. The magnetization curve was obtained in magnetic field up to 0.12 T between 30 and 70 K. This is the first to measure the anisotropy of hysteresis curve in the field above 0.1 T with an accuracy of 10{sup -12} J T{sup -1} (10{sup -9} emu) with a HTS micro-SQUID magnetometer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of Essential Element Distribution in the Equine Metacarpophalangeal Joint using a Synchrotron Radiation Micro X-Ray Fluorescence Technique

In articular cartilage, Ca, P, K and S are among some of the well known co-factors of the metalloproteinases enzymatic family, the latter playing a pivotal role in the growth and degeneration of the collagenous bone-cartilage interface of articulating joints. Current study forms part of a larger investigation concerning the distribution of these and other key elements in such media. For the purpose of evaluating these low atomic number elements (Z{<=}20), use was made of the capabilities of the LUCIA Station, located at the synchrotron facility of the Paul Scherrer Institute (PSI). Using an incident radiation energy of 4.06 keV, a synchrotron radiation micro x-ray fluorescence (SR-{mu}XRF) technique was applied in examining the distribution of the essential elements Ca, P, K and S in the bone-cartilage interface of both healthy and diseased (osteoarthritic) areas of an equine metacarpophalangeal joint. The SR-{mu}XRF mappings and line profile patterns have revealed remarkable changes in both the pattern and absolute distributions of these elements, agreeing with the findings of others. The elemental presence shown in the individual area scans encompassing the lesion each reflect the visibly abraded outer surface of the cartilage and change in shape of the bone surface. One of the area scans for the bone-cartilage interface shows a marked change in both the pattern and absolute elemental presence for all three elements compared to that observed at two other scan sites. The observation of change in bone cartilage composition around the surface of the articulating joint is thought to be novel, the variation being almost certainly due to the differing weight-bearing role of the subchondral bone at each locati0008.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observation of Ultra-Slow Antiprotons using Micro-channel Plate

Our group ASACUSA-MUSASHI has succeeded in accumulating several million antiprotons and extracting them as monochromatic ultra-slow antiproton beams (10 eV-1 keV) at CERN AD. We have observed ultra-slow antiprotons using micro-channel plates (MCP). The integrated pulse area of the output signals generated when the MCP was irradiated by ultra-slow antiprotons was 6 times higher than that by electrons. As a long-term effect, we also observed an increase in the background rate presumably due to the radioactivation of the MCP surface. Irradiating the antiproton beams on the MCP induces antiproton-nuclear annihilations only on the first layer of the surface. Low-energy and short-range secondary particles like charged nuclear fragments caused by the 'surface nuclear reactions' would be the origin of our observed phenomena.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Micro-Particles As Thermal Probes In Plasmas

Temperature sensitive 'thermographic' phosphors are utilized for measuring the temperature of micro-particles levitated in a plasma.The equilibrium temperature of particles T{sub p} in a plasma is determined by the sum of the energy fluxes between their surface and the surrounding plasma. By variation of gas composition and plasma parameters the different contributions to the total energy flux can be influenced. By measurement of the temperature of the microscopic probe particles, valuable information about the physics of plasma-particle interaction can be obtained. This is particularly of interest for dusty plasma research and the improvement of technical plasmas.Preliminary measurements of T{sub p} in the plasma-reactor PULVA-INP are presented, which show quite promising results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Q-Switched Nd: YAG Laser Micro-Machining System

In this paper, we present the design of a low cost Q-switched Nd: YAG laser micro-machining system for photo masks fabrication. It consists of: Nd:YAG laser source, beam delivery system, X-Y table, PC, The CCD camera and TV monitor. The synchronization between the laser source and the X-Y table is realised by NI PCI-7342, the two axis MID-7602 and LabVIEW based program. The first step of this work consists of engraving continuous and discontinuous lines on a thin film metal with a 100 {mu}m resolution by using the YG 980 Quantel Q-switched Nd:YAG laser.

36 MATERIALS SCIENCE↗

Calculation Of A Micro Discharge Energy Balance With PIC-MCC Method

In this paper, we present a 1D Particle in Cell with Monte Carlo Collisions model, developed in order to calculate the energy balance in a micro-discharge, under conditions similar to those of a Plasma Display Panel (PDP) cell. The discharge takes place in a xenon-neon (10%-;90%) mixture at 560 torr and for a gap length of 100 {mu}m. The model is used to analyze in details the energy deposition during the discharge pulse. The results show the amount of energy dissipated by ions (collisions in the gas and on the cathode), by electrons (excitation of the different electronic states, ionization), and their variations with the applied voltage. This model will be used in the future to test the approximations of the fluid models which are generally used to optimize PDP operating conditions, and to check whether or not fluid models can correctly predict the trends in the variations of the energy balance with parameters such as voltage, pressure, gas mixture.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photothermal Investigation of Micro-Uniformity Problems Caused by Different Scan Systems

To study beam scanning and beam profiling effects low energy implants of Boron (25 keV) and high energy implants of Helium (5.4 MeV) were carried out by use of different scanning systems including mechanical, electrostatic and hybrid scanning. The sensitivity of photothermal measurement by use of the excess carrier wave in the depth up to 50 {mu}m is proved for buried damage detection and compared with the effect in shallow damage profiles. The micro-mapping capability of the photothermal techniques allows the detection of dose variations in a sub-mm-scale without Moire effects from mapping steps. Conclusion for advanced dose monitoring by multi-frequency photothermal methods will be derived.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast Simulating High Order Models Application to Micro Electro-Mechanical Systems (MEMS)

The approximation of high order systems by low order models is one of the important problems in system theory. The use of a reduced order model makes it easier to implement analysis, simulations and control system designs. Numerous methods are available in the literature for order reduction of linear continuous systems in time domain as well as in frequency domain. But, this is not the case for non linear systems. The well known Trajectory Piece-Wise Linear approach (TPWL) elaborated to nonlinear model order reduction guarantees a simplification and an accurate representation of the behaviour of strongly non linear systems handling local and global approximation. The present attempt is towards evolving an improvement for the TPWL order reduction technique, which ensures a good quality of approximation combining the advantages of the Krylov subspaces method and the local linearization. We illustrate the technique on a MEMS circuit (Micro Electro-Mechanical System)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic bead counter using a micro-Hall sensor for biological applications

Micro-Hall sensors have been fabricated, and various numbers of micron-size magnetic beads have been placed within the sensor area. The Hall resistances measured at room temperature are found to be proportional to the number of the beads, and are in good agreement with the numerically simulated results presented in this study. Our sensors are designed to measure the number of beads between zero and full-scale signals for a given number range of interest. The effects of miniaturizing the beads and sensors to nanoscale are also discussed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Diffusion Experiment in Lithium Ionic Conductors with the Radiotracer of {sup 8}Li: from Micro- to Nano-diffusion

We have developed a radiotracer method for diffusion studies in lithium ionic conductors, by using, as the tracer, the short-lived {alpha}-emitting radioisotope of {sup 8}Li from TRIAC (Tokai Radioactive Ion Accelerator Complex). In the method, we measured {alpha}-particles coming out of the sample of interest and have found that the time-dependent yields of {alpha}-particle from the diffusing {sup 8}Li primarily implanted is a good measure of the Li diffusion in the sample. The method has been successfully applied to measure the lithium diffusion coefficients in a typical defect-mediated lithium ionic conductor of LiGa, well demonstrating that the method is very efficient to measure the diffusion in the micro-meter regime per second. Further development, as an extension of the present method, was proposed to measure the diffusion on the nanoscale in lithium ionic conductors.

36 MATERIALS SCIENCE↗