Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

A simplified lithium vapor box divertor

A detached divertor plasma is predicted to be necessary to mitigate the heat fluxes and ion energy, and so sputtering, at the divertor plate of a fusion power plant. It has proven difficult in current experiments, however, to prevent the detachment front, once formed, from running up to the main plasma resulting in deterioration of pedestal performance. The lithium vapor box divertor localizes a dense cloud of lithium vapor away from the main plasma, in order to induce detachment at a stable, distant location. The vapor localization is created by local evaporation and nearby condensation, a configuration inaccessible for non-condensing seed impurities. This paper provides simulations of lithium vapor flow using the SPARTA direct simulation Monte Carlo (DSMC) code, in which the lithium vapor dynamics are governed by Li–Li collisions that should dominate in regions with little plasma. Inertia is included in this code, permitting the formation of shocks. The plasma model implemented in SPARTA is based on UEDGE results for the location of ionization and recombination. We find that a simplified lithium vapor box configuration, without baffles, provides robust stabilization of the detachment front and acceptable lithium vapor flow to the main chamber. Lithium is evaporated from a capillary porous surface on the private-flux side of the divertor, distant from the main plasma, and is condensed on the other side walls of the divertor chamber. The condensed lithium flows back to the evaporator through 2 cm internal diameter pipes. The capillary pressure differential at the surface of the evaporator is capable of overcoming MHD back-force in the piping, with a great deal of margin if a sandwich flow channel insert is implemented. Very little lithium should be accumulated on the first wall of the main chamber if it is maintained at 600 °C, as expected for a power-producing fusion system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced assessment of beam-induced background at a muon collider

Renewed international interest in muon colliders motivates the continued investigation of the impacts of beam-induced background on detector performance. This continues the effort initiated by the Muon Accelerator Program and carried out until 2017. The beam-induced background from muon decays directly impacts detector performance and must be mitigated by optimizing the overall machine design, with particular attention paid to the machine detector interface region. In order to produce beam-induced background events and to study their characteristics in coordination with the collider optimization, a flexible simulation approach is needed. To achieve this goal we have chosen to utilize the combination of LineBuilder and Monte Carlo FLUKA codes. We report the results of beam-induced background studies with these tools obtained for a 1.5 TeV center of mass energy collider configuration. Good agreement with previous simulations using the MARS15 code demonstrates that our choice of tools meet the accuracy and performance requirements to perform future optimization studies on muon collider designs.

43 PARTICLE ACCELERATORS↗

ASAS J071404+7004.3 – a close, bright nova-like cataclysmic variable with gusty winds

ABSTRACT Despite being bright (V ≃ 11.8) and nearby (d = 212 pc) ASAS J071404+7004.3 has only recently been identified as a nova-like cataclysmic variable. We present time-resolved optical spectroscopy obtained at the Isaac Newton and the Hiltner and McGraw-Hill Telescopes, together with Swift X-ray and ultraviolet observations. We combined these with TESS photometry and find a period of 3.28 h and a mass transfer rate of $4\!-\!9\times 10^{-9}\, {\mathrm{M_{\odot }\, yr}^{-1}}$. Historical photometry shows at least one low state establishing the system as a VY Scl star. Our high-cadence spectroscopy also revealed rapidly changing winds emanating from the accretion disc. We have modelled these using the Monte Carlo python code and shown that all the emission lines could emanate from the wind – which would explain the lack of double-peaked lines in such systems. In passing, we discuss the effect of variability on the position of cataclysmic variables in the Gaia Hertzsprung–Russell diagram.

Inight, K. (ORCID:0000000222002416)↗

Parameter inference with non-linear galaxy clustering: accounting for theoretical uncertainties

ABSTRACT We implement euclidemulator (version 1), an emulator for the non-linear correction of the matter power spectrum, into the Markov chain Monte Carlo forecasting code montepython. We compare the performance of halofit, hmcode, and euclidemulator1, both at the level of power spectrum prediction and at the level of posterior probability distributions of the cosmological parameters, for different cosmological models and different galaxy power spectrum wavenumber cut-offs. We confirm that the choice of the power spectrum predictor has a non-negligible effect on the computed sensitivities when doing cosmological parameter forecasting, even for a conservative wavenumber cut-off of $0.2\, h\, {\rm Mpc}^{-1}$. We find that euclidemulator1 is on average up to 17 per cent more sensitive to the cosmological parameters than the other two codes, with the most significant improvements being for the Hubble parameter of up to 42 per cent and the equation of state of dark energy of up to 26 per cent, depending on the case. In addition, we point out that the choice of the power spectrum predictor contributes to the risk of computing a significantly biased mean cosmology when doing parameter estimations. For the four tested scenarios we find biases, averaged over the cosmological parameters, of between 0.5σ and 2σ (from below 1σ up to 6σ for individual parameters). This paper provides a proof of concept that this risk can be mitigated by taking a well-tailored theoretical uncertainty into account as this allows to reduce the bias by a factor of 2 to 5, depending on the case under consideration, while keeping posterior credibility contours small: the standard deviations are amplified by a factor of ≤1.4 in all cases.

Astronomy & Astrophysics↗

Total cross sections for ultracold neutrons scattered from gases

Here, we have followed up on our previous measurements of upscattering of ultracold neutrons (UCNs) from a series of gases by making measurements of total cross sections on the following gases hydrogen, ethane, methane, isobutene, n-butane, ethylene, water vapor, propane, neopentane, isopropyl alcohol, and 3 He. The values of these cross sections are important for estimating the loss rate of trapped neutrons due to residual gas and are relevant to neutron lifetime measurements using UCNs. The effects of the UCN velocity and path-length distributions were accounted for in the analysis using a Monte Carlo transport code. Results are compared to our previous measurements and with the known absorption cross section for 3 He scaled to our UCN energy. We find that the total cross sections for the hydrocarbon gases are reasonably described by a function linear in the number of hydrogen atoms in the molecule.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Elemental characterization of LL-MA radioactive waste packages with the associated particle technique

The French Alternative Energies and Atomic Energy Commission (CEA) and National Radioactive Waste Management Agency (ANDRA) are conducting an R and D program to improve the characterization of long-lived and medium activity (LL-MA) radioactive waste packages with analytical methods and with non-destructive nuclear measurements. This paper concerns fast neutron interrogation with the associated particle technique (APT), which brings 3D information about the waste material composition. The characterization of volume elements filled with iron, water, aluminium, and PVC in bituminized and fibre concrete LL-MA waste packages has been investigated with MCNP [1] and MODAR data analysis software [2]. APT provides usable information about major elements presents in the volumes of interest. However, neutron scattering on hydrogen nuclei spreads the tagged neutron beam out of the targeted volume towards surrounding materials, reducing spatial selectivity. Simulation shows that small less than 1 L targets can be characterised up to the half-radius of a 225 L bituminized drum, the matrix of which is very rich in hydrogen. Deeper characterization in concrete is possible but limited by counting statistics due to photon attenuation in this dense matrix and, unless large inspection volumes are considered, by the lack of spatial selectivity of the tagged neutron beam due to neutron scattering. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Boron-10 Lined Proportional Counter Model Validation

The decreasing supply of 3He is stimulating a search for alternative neutron detectors; one potential 3He replacement is 10B-lined proportional counters. Simulations are being performed to predict the performance of systems designed with 10B-lined tubes. Boron-10-lined tubes are challenging to model accurately because the neutron capture material is not the same as the signal generating material. Thus, to simulate the efficiency, the neutron capture reaction products that escape the lining and enter the signal generating fill gas must be tracked. The tube lining thickness and composition are typically proprietary vendor information, and therefore add additional variables to the system simulation. The modeling methodologies used to predict the neutron detection efficiency of 10B-lined proportional counters were validated by comparing simulated to measured results. The measurements were made with a 252Cf source positioned at several distances from a moderated 2.54-cm diameter 10B-lined tube. Models were constructed of the experimental configurations using the Monte Carlo transport code MCNPX, which is capable of tracking the reaction products from the (n,10B) reaction. Several different lining thicknesses and compositions were simulated for comparison with the measured data. This paper presents the results of the evaluation of the experimental and simulated data, and a summary of how the different linings affect the performance of a coincidence counter configuration designed with 10B-lined proportional counters.

Lintereur, Azaree T.↗

SU-E-T-274: Radiation Therapy with Very High-Energy Electron (VHEE) Beams in the Presence of Metal Implants

Purpose: To evaluate the effect of metal implants on treatment plans for radiation therapy with very high-energy electron (VHEE) beams. Methods: The DOSXYZnrc/BEAMnrc Monte Carlo (MC) codes were used to simulate 50–150MeV VHEE beam dose deposition and its effects on steel and titanium (Ti) heterogeneities in a water phantom. Heterogeneities of thicknesses ranging from 0.5cm to 2cm were placed at 10cm depth. MC was also used to calculate electron and photon spectra generated by the VHEE beams' interaction with metal heterogeneities. The original VMAT patient dose calculation was planned in Eclipse. Patient dose calculations with MC-generated beamlets were planned using a Matlab GUI and research version of RayStation. VHEE MC treatment planning was performed on water-only geometry and water with segmented prostheses (steel and Ti) geometries with 100MeV and 150MeV beams. Results: 100MeV PDD 5cm behind steel/Ti heterogeneity was 51% less than in the water-only phantom. For some cases, dose enhancement lateral to the borders of the phantom increased the dose by up to 22% in steel and 18% in Ti heterogeneities. The dose immediately behind steel heterogeneity decreased by an average of 6%, although for 150MeV, the steel heterogeneity created a 23% increase in dose directly behind it. The average dose immediately behind Ti heterogeneities increased 10%. The prostate VHEE plans resulted in mean dose decrease to the bowel (20%), bladder (7%), and the urethra (5%) compared to the 15MV VMAT plan. The average dose to the body with prosthetic implants was 5% higher than to the body without implants. Conclusion: Based on MC simulations, metallic implants introduce dose perturbations to VHEE beams from lateral scatter and backscatter. However, when performing clinical planning on a prostate case, the use of multiple beams and inverse planning still produces VHEE plans that are dosimetrically superior to photon VMAT plans. BW Loo and P Maxim received research support from RaySearch laboratories; B Hardemark and E Hynning are employees of RaySearch.

60 APPLIED LIFE SCIENCES↗

Preclinical investigation for developing injectable fiducial markers using a mixture of BaSO{sub 4} and biodegradable polymer for proton therapy

Purpose: The aim of this study is to investigate the use of mixture of BaSO{sub 4} and biodegradable polymer as an injectable nonmetallic fiducial marker to reduce artifacts in x-ray images, decrease the absorbed dose distortion in proton therapy, and replace permanent metal markers. Methods: Two samples were made with 90 wt. % polymer phosphate buffer saline (PBS) and 10 wt. % BaSO{sub 4} (B1) or 20 wt. % BaSO{sub 4} (B2). Two animal models (mice and rats) were used. To test the injectability and in vivo gelation, a volume of 200 μl at a pH 5.8 were injected into the Sprague-Dawley rats. After sacrificing the rats over time, the authors checked the gel morphology. Detectability of the markers in the x-ray images was tested for two sizes (diameters of 1 and 2 mm) for B1 and B2. Four samples were injected into BALB/C mice. The polymer mixed with BaSO{sub 4} transform from SOL at 20 °C with a pH of 6.0 to GEL in the living body at 37 °C with a pH of 7.4, so the size of the fiducial marker could be controlled by adjusting the injected volume. The detectability of the BaSO{sub 4} marker was measured in x-ray images of cone beam CT (CBCT), on-board imager [anterior–posterior (AP), lateral], and fluoroscopy (AP, lateral) using a Novalis-TX (Varian Medical Systems, Palo Alto, CA) repeatedly over 4 months. The volume, HU, and artifacts for the markers were measured in the CBCT images. Artifacts were compared to those of gold marker by analyzing the HU distribution. The dose distortion in proton therapy was computed by using a Monte Carlo (MC) code. A cylindrical shaped marker (diameter: 1 or 2 mm, length: 3 mm) made of gold, stainless-steel [304], titanium, and 20 wt. % BaSO{sub 4} was positioned at the center of the spread-out Bragg peak (SOBP) in parallel or perpendicular to the beam entrance. The dose distortion was measured on the depth dose profile across the markers. Results: Transformation to GEL and the biodegradation were verified. All BaSO{sub 4} markers could be detected in the CBCT. In the OBI and fluoroscopy images, all markers visible in the AP, but only B2(2 mm) could be identified in the lateral images. Changes of BaSO{sub 4} position were not detected in vivo (mice). The volume of the markers decreased by up to 65% and the HU increased by 22%, on average. The mean HU values around the B1, B2, and gold markers were 121.30 [standard deviation (SD): 54.86], 126.31 (SD: 62.13), and 1070.7 (SD: 235.16), respectively. The MC-simulated dose distortion for the BaSO{sub 4} markers was less than that of the commercially used markers. The dose reduction due to the gold marker was largest (15.05%) followed by stainless steel (7.92%) and titanium (6.92%). Dose reduction by B2 (2 mm) was 4.75% and 0.53% in parallel and perpendicular orientations, respectively. Conclusions: BaSO{sub 4} mixed with PBS is a good contrast agent in biodegradable polymer marker because of minimal artifacts in x-ray images and minimal dose reduction in proton therapy. The flexibility of the size is considered to be an advantage of this material over solid type fiducials.

60 APPLIED LIFE SCIENCES↗

Measurement and simulation of the cross sections for nuclide production in {sup 56}Fe and {sup nat}Cr targets irradiated with 0.04- to 2.6-GeV protons

The cross sections for nuclide production in thin {sup 56}Fe and {sup nat}Cr targets irradiated by 0.04-2.6-GeV protons are measured by direct {gamma} spectrometry using two {gamma} spectrometers with the resolutions of 1.8 and 1.7 keV for the {sup 60}Co 1332-keV {gamma} line. As a result, 649 yields of radioactive residual product nuclei have been obtained. The {sup 27}Al(p, x){sup 22}Na reaction has been used as a monitor reaction. The experimental data are compared with the MCNPX (BERTINI, ISABEL), CEM03.02, INCL4.2, INCL4.5, PHITS, and CASCADE07 calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement and simulation of the cross sections for nuclide production in {sup 93}Nb and {sup nat}Ni targets irradiated with 0.04- to 2.6-GeV protons

The cross sections for nuclide production in thin {sup 93}Nb and {sup nat}Ni targets irradiated by 0.04- to 2.6-GeV protons have been measured by direct {gamma} spectrometry using two {gamma} spectrometers with the resolutions of 1.8 and 1.7 keV in the {sup 60}Co 1332-keV {gamma} line. As a result, 1112 yields of radioactive residual nuclei have been obtained. The {sup 27}Al(p, x){sup 22}Na reaction has been used as a monitor reaction. The experimental data have been compared with the MCNPX (BERTINI, ISABEL), CEM03.02, INCL4.2, INCL4.5, PHITS, and CASCADE07 calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement and simulation of the cross sections for nuclide production in {sup nat}W and {sup 181}Ta targets irradiated with 0.04- to 2.6-GeV protons

The cross sections for nuclide production in thin {sup nat}Wand {sup 181}Ta targets irradiated by 0.04-2.6-GeV protons have been measured by direct {gamma} spectrometry using two {gamma} spectrometers with the resolutions of 1.8 and 1.7 keV in the {sup 60}Co 1332-keV {gamma} line. As a result, 1895 yields of radioactive residual product nuclei have been obtained. The {sup 27}Al(p, x){sup 22}Na reaction has been used as a monitor reaction. The experimental data have been compared with the MCNPX (BERTINI, ISABEL), CEM03.02, INCL4.2, INCL4.5, PHITS, and CASCADE07 calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Celeritas

Celeritas is a new Monte Carlo transport code designed for high-performance simulation of high-energy physics detectors.

Johnson, Seth R.↗

Power distribution estimation method for SMR using ex-core detectors: experimental demonstration by plural control rod patterns at KUCA

The power distribution estimation method based on the ex-core detectors, or PHOEBE, was demonstrated at Kyoto University Critical Assembly, KUCA. Generally, core monitoring systems use in-core neutron detectors. Since inside the core is a harsh environment, the maintainability and reliability of the detectors are deteriorated. On the other hand, the environment outside the core is milder: core monitoring by the ex-core detectors improves the maintainability and reliability especially for small modular reactors and micro-reactors. However, neutron information from the inner region of the core is lost at the ex-core detectors. To recover the information, the authors proposed to utilize the power correlation between the fuel regions. PHOEBE concept was demonstrated at KUCA with distorted power distributions simulated by control rod patterns. The relative power distribution estimated by PHOEBE agreed with that calculated by Monte Carlo simulation code MVP. PHOEBE approximately reproduced the trend of the distorted power distributions calculated by MVP code. By contrast, the case of without power correlation between fuel regions produced significant different power distributions. Therefore, the advantage of considering the power correlation between fuel regions was also demonstrated. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Accelerated coupled Monte Carlo-Thermal hydraulic calculations using a hybrid GTF-diffusion-based prediction block: first results

Accurate predictions of spatial power and temperature distributions require the coupling of a neutron transport solver with a thermal-hydraulic (TH) feedback. Nowadays, Monte Carlo (MC) codes are widely coupled to TH solvers, typically via a Picard iteration (PI) method, due to the higher fidelity that such frameworks can produce. To speed up a PI, a prediction step can produce an improved initial guess for a source distribution and feed it to the MC code. Recent work investigated a prediction step that uses generalized transfer functions (GTFs) to predict the macroscopic cross sections' variations following a perturbation in TH properties, such as coolant density. The previous method also relied on first order perturbation (FOP) theory to predict perturbed power profiles, rather than using an expensive MC iterate. The implemented FOP method relied on generating a fission matrix from which the forward and adjoint Eigenmodes were extracted and later used to for power calculations. The generation of the fission matrix can introduce a significant computational overhead, therefore undermining the performance of the proposed hybrid technique when applied to high-dimensional problems, e.g., full core calculations. This work attempts to improve the GTF-FOP prediction step by replacing the FOP solver with a nodal diffusion solver, thus eliminating the need to calculate a fission matrix. The GTF-diffusion step was tested for various moderator density perturbations. In each case, the predicted power distribution showed good agreement with the reference case. The latter is attributed to the generally good prediction of most spatially distributed macroscopic cross sections, except the transport cross section, which will become the focus of future work. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MPACT Fast Neutron Multiplicity System Design Concepts

This report documents work performed by Idaho National Laboratory and the University of Michigan in fiscal year (FY) 2012 to examine design parameters related to the use of fast-neutron multiplicity counting for assaying plutonium for materials protection, accountancy, and control purposes. This project seeks to develop a new type of neutron-measurement-based plutonium assay instrument suited for assaying advanced fuel cycle materials. Some current-concept advanced fuels contain high concentrations of plutonium; some of these concept fuels also contain other fissionable actinides besides plutonium. Because of these attributes the neutron emission rates of these new fuels may be much higher, and more difficult to interpret, than measurements made of plutonium-only materials. Fast neutron multiplicity analysis is one approach for assaying these advanced nuclear fuels. Studies have been performed to assess the conceptual performance capabilities of a fast-neutron multiplicity counter for assaying plutonium. Comparisons have been made to evaluate the potential improvements and benefits of fast-neutron multiplicity analyses versus traditional thermal-neutron counting systems. Fast-neutron instrumentation, using for example an array of liquid scintillators such as EJ-309, have the potential to either a) significantly reduce assay measurement times versus traditional approaches, for comparable measurement precision values, b) significantly improve assay precision values, for measurement durations comparable to current-generation technology, or c) moderating improve both measurement precision and measurement durations versus current-generation technology. Using the MCNPX-PoliMi Monte Carlo simulation code, studies have been performed to assess the doubles-detection efficiency for a variety of counter layouts of cylindrical liquid scintillator detector cells over one, two, and three rows. Ignoring other considerations, the best detector design is the one with the most detecting volume. However, operational limitations guide a) the maximum acceptable size of each detector cell (due to PSD performance and maximum-acceptable per-channel data throughput rates, limited by pulse pile-up and the processing rate of the electronics components of the system) and b) the affordability of a system due to the number of total channels of data to be collected and processed. As a first estimate, it appears that a system comprised of two rows of detectors 5" Ø $\times$ 3" would yield a working prototype system with excellent performance capabilities for assaying Pu-containing items and capable of handling high signal rates likely when measuring items with Pu and other actinides. However, it is still likely that gamma-ray shielding will be needed to reduce the total signal rate in the detectors. As a first step prior to working with these larger-sized detectors, it may be practical to perform scoping studies using small detectors, such as already-on-hand 3" Ø $\times$ 3" detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stochastic Particle Real Time Analyzer (SPARTA) Validation and Verification Suite

This report presents the test cases used to verify, validate and demonstrate the features and capabilities of the first release of the 3D Direct Simulation Monte Carlo (DSMC) code SPARTA (Stochastic Real Time Particle Analyzer). The test cases included in this report exercise the most critical capabilities of the code like the accurate representation of physical phenomena (molecular advection and collisions, energy conservation, etc.) and implementation of numerical methods (grid adaptation, load balancing, etc.). Several test cases of simple flow examples are shown to demonstrate that the code can reproduce phenomena predicted by analytical solutions and theory. A number of additional test cases are presented to illustrate the ability of SPARTA to model flow around complicated shapes. In these cases, the results are compared to other well-established codes or theoretical predictions. This compilation of test cases is not exhaustive, and it is anticipated that more cases will be added in the future.

97 MATHEMATICS AND COMPUTING↗

Stochastic Particle Real Time Analyzer (SPARTA) Validation and Verification Suite

This report presents the test cases used to verify, validate and demonstrate the features and capabilities of the first release of the 3D Direct Simulation Monte Carlo (DSMC) code SPARTA (Stochastic Real Time Particle Analyzer). The test cases included in this report exercise the most critical capabilities of the code like the accurate representation of physical phenomena (molecular advection and collisions, energy conservation, etc.) and implementation of numerical methods (grid adaptation, load balancing, etc.). Several test cases of simple flow examples are shown to demonstrate that the code can reproduce phenomena predicted by analytical solutions and theory. A number of additional test cases are presented to illustrate the ability of SPARTA to model flow around complicated shapes. In these cases, the results are compared to other well-established codes or theoretical predictions. This compilation of test cases is not exhaustive, and it is anticipated that more cases will be added in the future.

97 MATHEMATICS AND COMPUTING↗