Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

A method for reducing the largest relative errors in Monte Carlo iterated-fission-source calculations

In Monte Carlo iterated-fission-source calculations relative uncertainties on local tallies tend to be larger in lower-power regions and smaller in higher-power regions. Reducing the largest uncertainties to an acceptable level simply by running a larger number of neutron histories is often prohibitively expensive. The uniform fission site method has been developed to yield a more spatially-uniform distribution of relative uncertainties. This is accomplished by biasing the density of fission neutron source sites while not biasing the solution. The method is integrated into the source iteration process, and does not require any auxiliary forward or adjoint calculations. For a given amount of computational effort, the use of the method results in a reduction of the largest uncertainties relative to the standard algorithm. Two variants of the method have been implemented and tested. Both have been shown to be effective. (authors)

97 MATHEMATICS AND COMPUTING↗

Neutron Optics Optimization for the SNS EQ-SANS Diffractometer

The extended Q-range small angle neutron scattering (EQ-SANS) diffractometer at the Spallation Neutron Source has recently been completed. Initial commissioning has shown that it has achieved its high intensity, low background, and wide dynamic range design goals. One of the key components that enable these performances is its neutron optics, which are extensively optimized using analytical and Monte Carlo methods. The EQ-SANS optics consist of a curved multichannel beam bender and sections of straight neutron guides on both ends of the bender. The bender and the guide are made of float glass coated with supermirror multilayers. The function of the optics is to ensure low instrument background by avoiding the direct line of sight of the neutron moderator at downstream locations, while transporting thermal and cold neutrons to the sample with maximum efficiency. In this work, the optimization of the EQ-SANS optics is presented.

Monte Carlo Simulations.↗

Detecting fission from special nuclear material sources

A neutron detector system for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly into information that a first responder can use to discriminate materials. The system comprises counting neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source. The system includes a graphing component that displays the plot of the neutron distribution from the unknown source over a Poisson distribution and a plot of neutrons due to background or environmental sources. The system further includes a known neutron source placed in proximity to the unknown source to actively interrogate the unknown source in order to accentuate differences in neutron emission from the unknown source from Poisson distributions and/or environmental sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a liquid lithium thin film for use as a heavy ion beam stripper.

A series of experiments was performed to investigate the feasibility of a liquid lithium thin film for a charge stripper in a high-power heavy ion linac. Various preliminary experiments using simulants were first conducted to determine the film formation scheme, to investigate the film stability, and to obtain the design parameters for a liquid lithium thin film system. Based on the results from these preliminary studies, a prototypical, high pressure liquid lithium system was constructed to demonstrate liquid lithium thin film formation. This system was capable of driving liquid lithium at {approx}< 300 C and up to 13.9 MPa (2000 psig) through a nozzle opening as large as 1 mm (40 mil) in diameter. This drive pressure corresponds to a Li velocity of >200 m/s. A thin lithium film of 9 mm in width at velocity of {approx}58 m/s was produced. Its thickness was estimated to be roughly {approx}< 13 {micro}m. High vacuum was maintained in the area of the film. This type of liquid metal thin film may also be used in other high power beam applications such as for intense X-ray or neutron sources.

74 ATOMIC AND MOLECULAR PHYSICS↗

Methods and Procedures for Shielding Analyses for the SNS

In order to provide radiologically safe Spallation Neutron Source operation, shielding analyses are performed according to Oak Ridge National Laboratory internal regulations and to comply with the Code of Federal Regulations. An overview of on-going shielding work for the accelerator facility and neutrons beam lines, methods, used for the analyses, and associated procedures and regulations is presented. Methods used to perform shielding analyses are described as well.

43 PARTICLE ACCELERATORS↗

Westcott g factors extended to arbitrary neutron energy spectra

Westcott 𝑔 factors are used in Neutron Activation Analysis (NAA) and Prompt Gamma-ray Activation Analysis (PGAA) to evaluate the impact of non-1∕𝑣 behavior in the neutron-capture cross sections of certain nuclei on activation product yields. This non-1∕𝑣 behavior arises from the presence of neutron resonances in the neutron- capture cross sections that overlap with the source neutron spectrum at low (< 5 eV) energies. Historically, Westcott 𝑔 factors that have been cataloged for NAA and PGAA applications are the result of calculations that assume a Maxwellian neutron flux distribution with a given temperature. In this work, we use this approach with updated neutron-capture cross sections from the Evaluated Nuclear Data File, version VIII.1 (ENDF/B-VIII.1) to tabulate Westcott 𝑔 factor values for a broad range of Maxwellian distribution temperatures, comparing the results against currently-available 𝑔 factors from International Atomic Energy Agency tables and other sources. Here, it was discovered during this analysis that the use of guided thermal and cold-neutron beams at certain facilities necessitates an approach for evaluating Westcott 𝑔 factors based on arbitrary non-Maxwellian spectra. In this paper, we present an approach for calculating 𝑔 factors with user-specified neutron spectra, and we demonstrate these methods to obtain Westcott 𝑔-factors for guided- and cold-neutron beams at the Budapest Research Reactor and the Forschungsreaktor München II reactor. As part of this work, open-source software has been developed that can be used to perform these calculations for applications in PGAA and NAA experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In-Vessel Devices Based on Capillary-Porous Systems with Liquid Metal for a Stationary Tokamak

The experience gained in developing, creating, and testing prototypes of stationary in-vessel devices based on capillary-porous systems with liquid lithium for the T-11M, T-10, KTM, and FTU tokamaks is presented. A promising scheme is proposed for designing liquid-metal-based in-vessel components with heat removal for thermonuclear reactors of the DEMO type and thermonuclear neutron sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparative Neutron Detection Efficiency in He-3 Proportional Counters and Liquid Scintillators

We present new results on the neutron detection efficiency of detection systems based on He-3 proportional counters compared to organic liquid scintillators. The experiments were conducted using a well-characterized Cf-252 neutron source, measured bare, and shielded with slabs of polyethylene. The results show that the intrinsic neutron detection efficiency for the bare source is approximately 25% for the He-3 system, and 67% for the liquid scintillator system. When polyethylene sheets were used to shield the source in 2.54 cm increments, the neutron detection efficiency of both systems decreased exponentially to approximately 10% for the case of 25.4 cm. Experimental results were simulated using MCNPX-PoliMi and good agreement was found between measurement and simulation results for all the cases considered here.

Organic scintillator, He-3, neutron detection, det↗

Ion probe beam experiments and kinetic modeling in a dense plasma focus Z-pinch

The Z-pinch phase of a dense plasma focus (DPF) emits multiple-MeV ions in a ∼cm length. The mechanisms through which these physically simple devices generate such high energy beams in a relatively short distance are not fully understood. We are exploring the origins of these large gradients using measurements of an ion probe beam injected into a DPF during the pinch phase and the first kinetic simulations of a DPF Z-pinch. To probe the accelerating fields in our table top experiment, we inject a 4 MeV deuteron beam along the z-axis and then sample the beam energy distribution after it passes through the pinch region. Using this technique, we have directly measured for the first time the acceleration of an injected ion beam. Our particle-in-cell simulations have been benchmarked on both a kJ-scale DPF and a MJ-scale DPF. They have reproduced experimentally measured neutron yields as well as ion beams and EM oscillations which fluid simulations do not exhibit. Direct comparisons between the experiment and simulations enhance our understanding of these plasmas and provide predictive design capability for accelerator and neutron source applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dose rate verification for SNS spent structures - 25433

Residual dose rate measurements were conducted on two Spallation Neutron Source spent structures, target vessel no. 13 and proton beam window no. 5, after extraction from their service locations. These measurements were used to verify calculation methods for radionuclide inventory assessment that are typically performed for nuclear waste characterization and transportation. Neutronics analyses for predicting residual dose rates were carried out using complex and rigorous geometric models of the structures and their surroundings. Calculational results were analyzed and compared to the measured dose rates. (authors)

43 PARTICLE ACCELERATORS↗

The ESS spoke cavity cryomodules

The European Spallation Source (ESS) is a multi-disciplinary research centre under design and construction in Lund, Sweden. This new facility is funded by a collaboration of 17 European countries and is expected to be up to 30 times brighter than today’s leading facilities and neutron sources. The ESS will enable new opportunities for researchers in the fields of life sciences, energy, environmental technology, cultural heritage and fundamental physics. A 5 MW long pulse proton accelerator is used to reach this goal. The pulsed length is 2.86 ms, the repetition frequency is 14 Hz (4 % duty cycle), and the beam current is 62.5 mA. It is composed of one string of spoke cavity cryomodule and two strings of elliptical cavity cryomodules. This paper introduces the thermo-mechanical design and expected operation of the ESS spoke cavity cryomodules. These cryomodules contain two double spoke bulk Niobium cavities operating at 2 K and at a frequency of 352.21 MHz. The superconducting section of the Spoke Linac accelerates the beam from 90 MeV to 220 MeV. A Spoke Cavity Cryomodule Technology Demonstrator will be built and tested in order to validate the ESS series production.

43 PARTICLE ACCELERATORS↗

The ESS elliptical cavity cryomodules

The European Spallation Source (ESS) is a multi-disciplinary research centre under design and construction in Lund, Sweden. This new facility is funded by a collaboration of 17 European countries and is expected to be up to 30 times brighter than today’s leading facilities and neutron sources. The ESS will enable new opportunities for researchers in the fields of life sciences, energy, environmental technology, cultural heritage and fundamental physics. A 5 MW long pulse proton accelerator is used to reach this goal. The pulsed length is 2.86 ms, the repetition frequency is 14 Hz (4 % duty cycle), and the beam current is 62.5 mA. The superconducting section of the Linac accelerates the beam from 80 MeV to 2.0 GeV. It is composed of one string of spoke cavity cryomodule and two strings of elliptical cavity cryomodules. These cryomodules contain four elliptical Niobium cavities operating at 2 K and at a frequency of 704.42 MHz. This paper introduces the thermo-mechanical design, the prototyping and the expected operation of the ESS elliptical cavity cryomodules. An Elliptical Cavity Cryomodule Technology Demonstrator (ECCTD) will be built and tested in order to validate the ESS series production.

43 PARTICLE ACCELERATORS↗

Design and commissioning of a high magnetic field muon spin relaxation spectrometer at the ISIS pulsed neutron and muon source

The high magnetic field (HiFi) muon instrument at the ISIS pulsed neutron and muon source is a state-of-the-art spectrometer designed to provide applied magnetic fields up to 5 T for muon studies of condensed matter and molecular systems. The spectrometer is optimised for time-differential muon spin relaxation studies at a pulsed muon source. We describe the challenges involved in its design and construction, detailing, in particular, the magnet and detector performance. Commissioning experiments have been conducted and the results are presented to demonstrate the scientific capabilities of the new instrument.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Approach for the isotopic characterization of irradiated start-up sources for disposal at WIPP - 15674

The National Nuclear Security Administration, Global Threat Reduction Initiative (GTRI)/ Off-site Source Recovery Program (OSRP) requires an approved final disposition pathway for sealed irradiated startup sources with uncertain irradiation histories. To create this path a reliable method is required to determine yields of transmutation, fission and activation products contained within the source at the time of disposal. Because of the uncertain histories of these sources, a number of likely histories are modeled with the code ORIGEN in order to establish the bounds of the radioisotope yields. The ORIGEN simulations are confirmed with gamma spectroscopy, specifically examining the activities of several fission and transmutation isotopes. These calculations, coupled with other previously established characterization techniques for transuranic neutron sources, will be used to establish a waste profile that is in compliance with Waste Isolation Pilot Plant (WIPP) waste acceptance criteria. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Place polarized neutron reflectivity data in bins of constant wavevector transfer

Code to place polarized neutron reflectivity into bins of constant Qz with regard for Zeeman energy change to the spin-flip channel. The code is written as a Jupyter notebook. Example data are included as separate files (spin_down.txt and spin_up.txt). As a first step, run all cells in the notebook. Opportunities are identified for users to make their own choices for analysis of the data. The code is written to be a stand-alone operation on data collected from a pulse neutron source that have been previously normalized to the wavelength dependence of the incident beam spectrum, background subtracted, etc. The constant Qz binning (this code) is the last step to perform in the analysis (reduction) workflow. This step yields the the reflectivities for the four neutron spin cross-sections. A future intention is to create a version of this code that will be one module of many in the data analysis workflow.

Fitzsimmons, Michael [Oak Ridge National Lab. (ORN↗

Towards a reference numerical scheme using MCNPX for PWR control rod tip fluence estimations

Recent occurrences of cracks and fissures on the cladding tubes of PWR control rod (CR) fingers employed in the Swiss reactors prompted the need to develop more reliable analytical methods for CR tip fluence estimations. To partly address this need, a deterministic methodology based on SIMULATE-3/CASMO-4 was in recent years developed at PSI. Although this methodology has already been applied for independent support to licensing issues related to CR lifetime, two main questions are currently being the center of attention for further enhancements. First, the methodology relies on several assumptions that have so far not been verified. Secondly, an assessment of the achieved accuracy has not been addressed. In an attempt to answer both these open questions, it was considered appropriate to develop an alternative computational scheme based on the stochastic MCNPX code with the objective to provide reference numerical solutions. This paper presents the first steps undertaken in that direction. To start, a methodology for a volumetric neutron source transfer to full core MCNPX models with detailed CR as well as axial reflector representations is established. On this basis, the assumptions of the deterministic methodology are studied for selected CR configurations for two Beginning-of-Life cores by comparing the spatial neutron flux distributions obtained with the two approaches for the entire spectrum. Finally, for the high-energy range (E> 1 MeV) and for a few CRs, the new MCNPX scheme is applied to estimate the accumulated fluence over one real operated cycle and the results are compared with the deterministic approach. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The s-process enrichment of the globular clusters M4 and M22

We investigate the enrichment in elements produced by the slow neutron-capture process (s-process) in the globular clusters M4 (NGC 6121) and M22 (NGC 6656). Stars in M4 have homogeneous abundances of Fe and neutron-capture elements, but the entire cluster is enhanced in s-process elements (Sr, Y, Ba, Pb) relative to other clusters with a similar metallicity. In M22, two stellar groups exhibit different abundances of Fe and s-process elements. By subtracting the mean abundances of s-poor from s-rich stars, we derive s-process residuals or empirical s-process distributions for M4 and M22. We find that the s-process distribution in M22 is more weighted toward the heavy s-peak (Ba, La, Ce) and Pb than M4, which has been enriched mostly with light s-peak elements (Sr, Y, Zr). We construct simple chemical evolution models using yields from massive star models that include rotation, which dramatically increases s-process production at low metallicity. We show that our massive star models with rotation rates of up to 50% of the critical (break-up) velocity and changes to the preferred {sup 17}O(α, γ){sup 21}Ne rate produce insufficient heavy s-elements and Pb to match the empirical distributions. For models that incorporate asymptotic giant branch yields, we find that intermediate-mass yields (with a {sup 22}Ne neutron source) alone do not reproduce the light-to-heavy s-element ratios for M4 and M22, and that a small contribution from models with a {sup 13}C pocket is required. With our assumption that {sup 13}C pockets form for initial masses below a transition range between 3.0 and 3.5 M {sub ☉}, we match the light-to-heavy s-element ratio in the s-process residual of M22 and predict a minimum enrichment timescale of between 240 and 360 Myr. Our predicted value is consistent with the 300 Myr upper limit age difference between the two groups derived from isochrone fitting.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First in-situ lattice strains measurements under load at VULCAN

The engineering materials diffractometer, VULCAN, at the Spallation Neutron Source began commissioning on June 26, 2009. This instrument is designed for materials science and engineering studies. In situ lattice strain measurements of a model metallic material under monotonic tensile load have been performed on VULCAN. The tensile load was applied under two different strain rates, and neutron diffraction measurements were carried out in both high-intensity and high-resolution modes. These experiments demonstrated VULCAN's in situ study capability of deformation behaviors even during the early phases of commissioning.

43 PARTICLE ACCELERATORS↗