Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Data Library”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,262 records · Page 71

Deep learning and radiomics: the utility of Google TensorFlow™ Inception in classifying clear cell renal cell carcinoma and oncocytoma on multiphasic CT

Purpose: Currently, all solid enhancing renal masses without microscopic fat are considered malignant until proven otherwise and there is substantial overlap in the imaging findings of benign and malignant renal masses, particularly between clear cell RCC (ccRCC) and benign oncocytoma (ONC). Radiomics has attracted increased attention for its utility in pre-operative work-up on routine clinical images. Radiomics based approaches have converted medical images into mineable data and identified prognostic imaging signatures that machine learning algorithms can use to construct predictive models by learning the decision boundaries of the underlying data distribution. The TensorFlow™ framework from Google is a state-of-the-art open-source software library that can be used for training deep learning neural networks for performing machine learning tasks. The purpose of this study was to investigate the diagnostic value and feasibility of a deep learning-based renal lesion classifier using open-source Google TensorFlow™ Inception in differentiating ccRCC from ONC on routine four-phase MDCT in patients with pathologically confirmed renal masses. Methods: With institutional review board approval for this 1996 Health Insurance Portability and Accountability Act compliant retrospective study and a waiver of informed consent, we queried our institution’s pathology, clinical, and radiology databases for histologically proven cases of ccRCC and ONC obtained between January 2000 and January 2016 scanned with a an intravenous contrast-enhanced four-phase renal mass protocol (unenhanced (UN), corticomedullary (CM), nephrographic (NP), and excretory (EX) phases). To extract features to be used for the machine learning model, the entire renal mass was contoured in the axial plane in each of the four phases, resulting in a 3D volume of interest (VOI) representative of the entire renal mass. We investigated thirteen different approaches to convert the acquired VOI data into a set of images that adequately represented each tumor which was used to train the final layer of the neural network model. Training was performed over 4000 iterations. In each iteration, 90% of the data were designated as training data and the remaining 10% served as validation data and a leave-one-out cross-validation scheme was implemented. Accuracy, sensitivity, specificity, positive (PPV) and negative predictive (NPV) values, and CIs were calculated for the classification of the thirteen processing modes. Results: We analyzed 179 consecutive patients with 179 lesions (128 ccRCC and 51 ONC). The ccRCC cohort had a mean size of 3.8 cm (range 0.8–14.6 cm) and the ONC cohort had a mean lesion size of 3.9 cm (range 1.0–13.1 cm). The highest specificity and PPV (52.9% and 80.3%, respectively) were achieved in the EX phase when we analyzed the single mid-slice of the tumor in the axial, coronal and sagittal plane, and when we increased the number of mid-slices of the tumor to three, with an accuracy of 75.4%, which also increased the sensitivity to 88.3% and the PPV to 79.6%. Using the entire tumor volume also showed that classification performance was best in the EX phase with an accuracy of 74.4%, a sensitivity of 85.8% and a PPV of 80.1%. When the entire tumor volume, plus mid-slices from all phases and all planes presented as tiled images, were submitted to the final layer of the neural network we achieved a PPV of 82.5%. Conclusions: The best classification result was obtained in the EX phase among the thirteen classification methods tested. Our proof of concept study is the first step towards understanding the utility of machine learning in the differentiation of ccRCC from ONC on routine CT images. We hope this could lead to future investigation into the development of a multivariate machine learning model which may augment our ability to accurately predict renal lesion histology on imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Demonstration of Full Core Reactor Depletion with MPACT

MPACT is a three-dimensional (3-D) whole core transport code capable of generating sub-pin level power distributions. This feature is accomplished by obtaining the integral transport solutions to the heterogeneous reactor problem in which the actual detailed geometrical configuration of fuel components such as the pellet and cladding is modelled explicitly.. The cross section data needed for the neutron transport calculation are obtained directly from a multigroup microscopic cross section library similar to those used in lattice physics codes. Hence MPACT involves neither a priori homogenization nor group condensation for the core spatial solution. The integral transport solution is obtained by means of the method of characteristics (MOC) that employs discrete ray tracing. Since the direct application of the 3-D MOC capability in MPACT to 3-D core configuration requires considerable amounts of memory and computing time for practical reactor applications, an alternative approximate 3-D solution method was implemented in MPACT based on a 2D-1D approach which employs planar MOC solutions in the framework of the 3-D coarse mesh finite difference (CMFD) formulation. The axial coupling is resolved by one-dimensional (1-D) diffusion solutions and the planar and axial problems are coupled through the transverse leakage. The use of a lower order 1-D solution in the axial direction is justified by the fact that most heterogeneity in the core occurs in the radial direction rather than the axial. However, it is possible to use one of the higher order methods in MPACT such as the 1-D SN kernel if improved solution accuracy is desired. The CMFD formulation which originally served as an efficient nodal formulation is used in MPACT to accelerate the whole core transport calculation. The basic mesh in the CMFD formulation is a pin cell which is much coarser than the flat source regions defined for MOC calculations. The concept of dynamic homogenization of group constants for the pin cells provides the basis of the CMFD formulation in whole core transport calculation. The intra-cell flux distribution determined from the MOC calculation is used to generate the homogenized cell constants while the MOC cell surface averaged currents are used to determine the radial nodal coupling coefficients. This dynamic implementation of the equivalence theory formulation ensures the same transport solution is obtained with CMFD as the one obtained using unaccelerated MOC calculations alone. The ability of MPACT to predict the Hot, Zero Power (HZP) condition of a reactor was reported in CASL-U-2014-0045-000. The purpose of this report is to demonstrate the capability of MPACT to simulate the operation of a reactor at Hot, Full Power (HFP) conditions during normal operation throughout a full operating cycle. The time scale for a reactor burnup cycle is typically one to two years and therefore short time phenomena such as the effect of delayed neutrons can be neglected. Instead the time dependence can be treated quasi-statically using the depletion algorithm presented in CASL-U-2013-0276-001. The full power operation requires thermal hydraulic feedback to be present during the entire simulation which will utilize the work in CASL-U-2014-0051-000. However, due to the significant computational burden of the coupled physics simulation, a simplified thermal hydraulic model is used for the analysis reported here which is principally intended to demonstrate the full core neutronics depletion. In addition to the thermal hydraulic feedback, the effect of Boron 10 depletion should be modeled in cases where major boron additions are not performed for extended periods of time. Each of these capabilities will be described in the following sections.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗