NC Data - Nuclear Collision Data for nucleon-nucleus collisions in the energy range 25 to 400 MeV
FORTRAN computer program for cross sections, and particle emission analysis in nucleon-nucleus collisions
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
FORTRAN computer program for cross sections, and particle emission analysis in nucleon-nucleus collisions
The SCALE code package offers several nuclear data libraries to support Monte Carlo (MC) transport, as well as MC-based derivation of $\kappa$ eff sensitivity and uncertainty (S/U) data. The CSAS sequence using the KENO MC code can utilize continuous-energy (CE) cross sections, or pre-generated multigroup (MG) cross section libraries. The use of MG libraries introduces bias into calculations in exchange for faster transport solutions. The TSUNAMI-3D sequence also utilizes KENO MC calculations. TSUNAMI-3D has two CE calculational methods: the Iterated Fission Probability (IFP) method, and the Contribution-Linked eigenvalue sensitivity/Uncertainty estimation via Tracklength importance CHaracterization (CLUTCH) method. Previous work has shown poor agreement between CLUTCH and confirmatory direct perturbation calculations in specific applications, e.g., fissionable and polyethylene reflectors
Dry storage of used nuclear fuel in the United States will continue until a disposition pathway is chosen and implemented. As such, the duration of dry storage will be much longer than originally anticipated. This paper reviews the methodology used in and the results of an analysis to determine the technical data gaps that need to be addressed to assure the continued safe and secure storage of used nuclear fuel for extended periods. Six high priority and eleven medium priority mechanisms were identified that may degrade the safety functions of the dry storage structures, systems, and components.
In this paper, we compare dwarf galaxies and galaxy clusters in order to elucidate which object class is the best target for gamma-ray DM searches with imaging atmospheric Cherenkov telescopes (IACTs). We have built a mixed dwarfs+clusters sample containing some of the most promising nearby dwarf galaxies (Draco, Ursa Minor, Wilman 1 and Segue 1) and local galaxy clusters (Perseus, Coma, Ophiuchus, Virgo, Fornax, NGC 5813 and NGC 5846), and then compute their DM annihilation flux profiles by making use of the latest modeling of their DM density profiles. We also include in our calculations the effect of DM substructure. Willman 1 appears as the best candidate in the sample. However, its mass modeling is still rather uncertain, so probably other candidates with less uncertainties and quite similar fluxes, namely Ursa Minor and Segue 1, might be better options. As for galaxy clusters, Virgo represents the one with the highest flux. However, its large spatial extension can be a serious handicap for IACT observations and posterior data analysis. Yet, other local galaxy cluster candidates with more moderate emission regions, such as Perseus, may represent good alternatives. After comparing dwarfs and clusters, we found that the former exhibit annihilation flux profiles that, at the center, are roughly one order of magnitude higher than those of clusters, although galaxy clusters can yield similar, or even higher, integrated fluxes for the whole object once substructure is taken into account. Even when any of these objects are strictly point-like according to the properties of their annihilation signals, we conclude that dwarf galaxies are best suited for observational strategies based on the search of point-like sources, while galaxy clusters represent best targets for analyses that can deal with rather extended emissions. Finally, we study the detection prospects for present and future IACTs in the framework of the constrained minimal supersymmetric standard model. We find that the level of the annihilation flux from these targets is below the sensitivities of current IACTs and the future CTA.
The Tomographic Gamma-ray Scanner (TGS) for large volume drummed waste has been successfully commercialized by Canberra over the last several years. As part of an R and D effort to continually improve this technology, we have developed a scaled down version of the standard commercial product (Can-TGS). The Can-TGS is able to accommodate cans and pails of various sizes, ranging from sub-liter to 20 liter volumes with densities of up to 4 g/cc. The Can-TGS has three diamond-shaped collimators (6.35 mm [0.25''], 12.7 mm [0.5''], and 25.4 mm [1'']) to facilitate a range of container volumes and heights. As with the standard TGS, the Can-TGS has a transmission source sub-system, where the transmission source can be easily swapped between sources of various strengths and type. The acquisition portion of the Can-TGS is powered by the Canberra Lynx{sup R} MCA which accommodates both multi-spectral scaling (MSS) and list-mode. Recently, the Can-TGS has been successfully characterized for an 18.93 L [5-gallon] container for the 25.4 mm diamond-shaped collimator. In principle, a single measurement (with good statistics) is required for each configuration in order to characterize the system. However, for this study, measurements were performed for several different matrices. For each matrix used, 6 different measurements were acquired. For each of these measurements, the drum was rotated 60 deg. with respect to the previous starting position. This procedure was followed in order to average out any radial bias that might be produced from just a single measurement. A description of the Can-TGS system is given. The details of the recent characterization measurements and the associated data analysis and results are presented. TGS results are compared with Segmented Gamma Scanner (SGS) results for the same source configuration. Additionally, the future outlook for Canberra's R and D efforts with this system is discussed. These efforts include TGS algorithm optimization, improving our understanding of the uncertainties associated with TGS results, and the overall benefits and limitations of this technology as compared to other available non-destructive assay techniques. (authors)
Purpose: Phase-based and amplitude-based sorting techniques are commonly used in four-dimensional CT (4DCT) reconstruction. However, effect of these sorting techniques on 4D dose calculation has not been explored. In this study, the authors investigated a candidate 4DCT sorting technique by comparing its 4D dose calculation accuracy with that for phase-based and amplitude-based sorting techniques.Method: An optimization model was formed using organ motion probability density function (PDF) in the 4D dose convolution. The objective function for optimization was defined as the maximum difference between the expected 4D dose in organ of interest and the 4D dose calculated using a 4DCT sorted by a candidate sampling method. Sorting samples, as optimization variables, were selected on the respiratory motion PDF assessed during the CT scanning. Breathing curves obtained from patients' 4DCT scanning, as well as 3D dose distribution from treatment planning, were used in the study. Given the objective function, a residual error analysis was performed, and k-means clustering was found to be an effective sampling scheme to improve the 4D dose calculation accuracy and independent with the patient-specific dose distribution. Results: Patient data analysis demonstrated that the k-means sampling was superior to the conventional phase-based and amplitude-based sorting and comparable to the optimal sampling results. For phase-based sorting, the residual error in 4D dose calculations may not be further reduced to an acceptable accuracy after a certain number of phases, while for amplitude-based sorting, k-means sampling, and the optimal sampling, the residual error in 4D dose calculations decreased rapidly as the number of 4DCT phases increased to 6.Conclusion: An innovative phase sorting method (k-means method) is presented in this study. The method is dependent only on tumor motion PDF. It could provide a way to refine the phase sorting in 4DCT reconstruction and is effective for 4D dose accumulation. Optimized sorting techniques could achieve acceptable residuals (less than 0.5% of the prescription dose) using 6 sorting samples, which is much better than amplitude-based or phase-based sorting. Further increase in sorting phase number exceeding 6 or more may not be necessary when using the k-means sampling or optimal sampling points.
This document presents a full-scope Digital Infrastructure implementation and associated lifecycle support recommendations that enable a plant life of 80+ years. Specific technologies and software applications are researched, developed, selected, implemented, and then integrated by utilities to enhance safety, reliability, and economic performance such that the result provides much more than the sum of its parts. Specific selection of these technologies is driven by business case analyses which are utility, station, and unit specific.
This study proposes a method to incorporate covariate information into sparse functional data analysis. The method aims at cases where each subject has a limited number of longitudinal measurements and is associated with static covariates. This research is motivated by several use cases in practice. One representative example is void swelling, a nuclear-specific material degradation mechanism. Void swelling is affected by many covariates, including alloy composition and irradiation type. How to accurately model the complicated joint effects of such covariates on the swelling process is the key to mitigating the effect of swelling and ensuring safe operation. Unlike most of the existing methods, the proposed method can handle high-dimensional covariates with the informative covariate identification procedure and sparse and irregularly spaced measurements, that is, does not require complete or dense observations. The main innovation of the proposed method is that we model the variation coming from covariates and the variation left conditioned on covariates, such that the functional principal component analysis and Gaussian process can be conducted in a unified manner. Further, we also propose a systematic approach to identify important covariates in the hypothesis testing context. The methodology is demonstrated on applications in nuclear engineering and healthcare and simulation studies.
Infrared (IR) thermography is widely used in fusion research to study power exhaust and incident heat load onto the plasma facing components. Due to the short pulse duration of today’s fusion experiments, IR systems have mostly been designed for off-line data analysis. For future long pulse devices (e.g., Wendelstein 7-X, ITER), a real time evaluation of the target temperature and heat flux is mandatory. This paper shows the development of a real time capable IR system for ASDEX Upgrade. A compact IR camera has been designed incorporating the necessary magnetic and electric shielding for the detector, cooler assembly. The camera communication is based on the Camera Link industry standard. The data acquisition hardware is based on National Instruments hardware, consisting of a PXIe chassis inside and a fibre optical connected industry computer outside the torus hall. Image processing and data evaluation are performed using real time LabVIEW.
Recent observations of neutron stars with gravitational waves and X-ray timing provide unprecedented access to the equation of state (EoS) of cold dense matter at densities difficult to realize in terrestrial experiments. At the same time, predictions for the EoS equipped with reliable uncertainty estimates from chiral effective field theory ( x EFT) allow us to bound our theoretical ignorance. In this work, we analyze astrophysical data using a nonparametric representation of the neutron-star EoS conditioned on x EFT to directly constrain the underlying physical properties of the compact objects without introducing modeling systematics. We discuss how the data alone constrain the EoS at high densities when we condition on x EFT at low densities. Here, we also demonstrate how to exploit astrophysical data to directly test the predictions of x EFT for the EoS up to twice nuclear saturation density, in order to estimate the density at which these predictions might break down. We nd that the existence of massive pulsars, gravitational waves from GW170817, and NICER observations of PSR J0030+0451 favor x EFT predictions for the EoS up to nuclear saturation density over a more agnostic analysis by as much as a factor of 7 for the quantum Monte Carlo (QMC) calculations used in this work. While x EFT predictions using QMC are fully consistent with gravitational-wave data up to twice nuclear saturation density, NICER observations suggest that the EoS stiffens relative to these predictions at or slightly above nuclear saturation density. Additionally, for these QMC calculations, we marginalize over the uncertainty in the density at which x EFT begins to break down, constraining the radius of a 1.4M $\bigodot$ neutron star to R 1.4 = $11.40^{+1.38}_{–1.04}$ ($12.54^{+0.71}_{–0.63}$) km and the pressure at twice nuclear saturation density to p(2n sat ) = $14.2^{+18.1}_{–8.4}$ ($28.7^{+15.3}_{–15.0}$) MeV=fm 3 with massive pulsar and gravitational-wave (and NICER) data.
An overview of the hardware and software developed for the Source Term Analysis of Xenon (STAX) project is presented which includes the data collection from two stack monitoring systems installed at medical isotope production facilities, infrastructure to transfer data to a central repository, and methods for sharing data from the repository with users. STAX is an experiment to collect radioxenon emission data from industrial nuclear facilities with the goal of developing a better understanding of the global radioxenon background and the effect industrial radioxenon releases have on nuclear explosion monitoring. The final goal of this work is to utilize collected data along with atmospheric transport modeling to calculate the contribution of a peak or set of peaks detected by the International Monitoring System (IMS) to provide desired discriminating information to the International Data Centre (IDC) and National Data Centers (NDCs). Types of data received from the STAX equipment are shown and collected data was used for a case study to predict radioxenon concentrations at two IMS stations closest to the Institute for RadioElements (IRE) in Belgium. The initial evaluation of results indicate that the data is very valuable to the nuclear explosion monitoring community.
The performance of many diagnostic and control systems within fusion and other fields of research are often detrimentally affected by spurious noise signals. This is particularly true for those (such as radiation or particle detectors) working with very small signals. Common sources of radiated and conducted noise in experimental fusion environments include the plasma itself and instrumentation. The noise complicates data analysis, as illustrated by noise on signals measured with the heavy ion beam probe (HIBP) installed on the Madison Symmetric Torus. The noise is time-varying and often exceeds the secondary ion beam current (in contrast with previous applications). Analysis of the noise identifies the dominant source as photoelectric emission from the detectors induced by ultraviolet light from the plasma. This has led to the development of a calibrated subtraction technique, which largely removes the undesired temporal noise signals from data. The advantages of the technique for small signal measurement applications are demonstrated through improvements realized on HIBP fluctuation measurements.
Experiments for 142 Ce have been performed in 2019. The data are reduced to cross section and transmission, respectively. Report for 142 Ce experiments is in preparation. Data analysis is underway, and the evaluation should be finalized by the end of 2020. 90 Zr sample is produced, but experiments planned for 2020 are delayed due to COVID-19.
In astrophysics, the first excited 0{sup +} state of {sup 12}C at 7.654 MeV (Hoyle state) is the most important in the triple-{alpha} process for carbon nucleosynthesis. In explosive scenarios like supernovae, where temperatures of several 10{sup 9} K are achieved, the interference of the Hoyle state with the second 0{sup +} state located at 10.3 MeV in {sup 12}C becomes significant. The recent NACRE compilation of astrophysical reaction rates assumes a 2{sup +} resonance at 9.1 MeV for which no experimental evidence exists. Thus, it is critical to explore in more detail the 7-10 MeV excitation energy region, especially the minimum between the two 0{sup +} resonances for carbon nucleosynthesis. The states in {sup 12}C were populated through the {beta}-decay of {sup 12}B and {sup 12}N produced at the ATLAS (Argonne Tandem Linac Accelerator System) in-flight facility. The decay of {sup 12}C into three alphas is detected in a Frisch grid twin ionization chamber, acting as a low-threshold calorimeter. This minimizes the effects of {beta}-summing and allowed us to investigate the minimum above the Hoyle state with much higher accuracy than previously possible. A detailed data analysis will include an R-matrix fit to determine an upper limit on the 2{sup +} resonance width.
We discuss the observation and data analysis of argon K-shell line spectra from argon-doped deuterium-filled OMEGA direct-drive implosion cores based on data recorded with two streaked crystal spectrometers. The targets were 870 {mu}m in diameter, 27 {mu}m wall thickness plastic shells filled with 20 atm of deuterium gas, and a tracer amount of argon for diagnostic purposes. The argon K-shell line spectrum is primarily emitted at the collapse of the implosion and its analysis provides a spectroscopic diagnostic of the core implosion conditions. The observed spectra includes the He{alpha}, Ly{alpha}, He{beta}, He{gamma}, Ly{beta}, and Ly{gamma} line emissions and their associated He- and Li-like satellites thus covering a broad photon energy range from 3100 to 4200 eV with a spectral resolution power of approximately 500. The data analysis relies on detailed atomic and spectral models that take into account nonequilibrium collisional-radiative atomic kinetics, Stark-broadened line shapes, and radiation transport calculations.
In 2017, the United States Department of Energy (DOE) collaborated with Spanish and Korean organizations to perform a multimodal transportation test to measure shock and vibration loads imparted to used nuclear fuel (UNF) assemblies. This test used real fuel assembly components containing surrogate fuel mass to approximate the response characteristics of real, irradiated used nuclear fuel. Pacific Northwest National Laboratory was part of the test team and used the data collected during this test to validate numerical models needed to predict the response of real used nuclear fuel in other transportation configurations. This paper summarizes the modeling work and identifies lessons learned related to the modeling and analysis methodology. The modeling includes railcar dynamics using the NUCARS software code and explicit dynamic finite element modeling of used nuclear fuel cladding in LS-DYNA. The NUCARS models were validated against railcar dynamics data collected during captive track testing at the Federal Railroad Administration's Transportation Technology Center in Pueblo, CO. The LS-DYNA models of the fuel cladding were validated against strain gage data collected throughout the test campaign. One of the key results of this work was an assessment of fuel cladding fatigue, and the methods used to calculate fatigue are detailed in this paper. The validated models and analysis methodologies described in this paper will be applied to evaluate future UNF transportation systems.
Since 1999, the Government of Canada has been conducting a regular exercise of gathering and compiling Canada's radioactive waste inventory and projection data from waste owners and making it available to the public in the form of a triennial Inventory Summary Report. The goal of this data collection exercise has been to support federal policy development, support the Canadian Nuclear Safety Commission's regulatory activities, provide consolidated radioactive waste information for the nuclear industry, promote transparency, and meet Canada's international commitments and growing demands internationally for radioactive waste data. The detailed national inventory report provides an overview of the production, accumulation and future projections of radioactive waste in Canada. Since the coming into force of the Joint Convention on the Safety of Spent Fuel Management and on the Safety of Radioactive Waste Management in June 2001, the data collection and reporting cycle has been aligned to provide the waste inventory data required for Canada's triennial National Report for the Joint Convention. This paper presents Canada's radioactive waste inventory and projection data as of the end of December 2016, and summarizes key findings from the analysis of the data. For this reporting cycle, the waste data collected was expanded to include more detailed information on the decommissioning schedules and associated waste volume projections for nuclear power plants, and research and prototype reactors, as well as plans for transitioning waste inventories from storage to long-term management and disposal facilities, based on current schedules for establishing these facilities in Canada. With this additional information, the Government of Canada and Canadian stakeholders are better able to understand the waste disposal capacity and schedules required to accommodate all nuclear fuel waste and radioactive waste that will be produced by Canada's existing fleet of nuclear power plants and research reactors. The collection and analysis of projected waste volumes to be emplaced in long-term management facilities is in line with and will support the proposed methodology of presenting waste inventories in terms of management strategy and disposal routes by the Organization for Economic Cooperation and Development Nuclear Energy Agency Expert Group on Waste Inventorying and Reporting Methodology. The paper describes some of the uses that are made of the waste inventory information, as well as Canada's approach to national inventory data collection and its experience and lessons learned. Canada continues to modernize the format of the Inventory Summary Report with the goal of disseminating the technical information into an attractive and public-friendly report. (authors)
Matrix-assisted laser desorption/ionization coupled with Orbitrap mass spectrometry (MALDI-Orbitrap-MS) is used for the clinical study of patients with renal cell carcinoma (RCC), as the most common type of kidney cancer. Significant changes in sulfoglycosphingolipid abundances between tumor and autologous normal kidney tissues are observed. First, sulfoglycosphingolipid species in studied RCC samples are identified using high mass accuracy full scan and tandem mass spectra. Subsequently, optimization, method validation, and statistical evaluation of MALDI-MS data for 158 tissues of 80 patients are discussed. More than 120 sulfoglycosphingolipids containing one to five hexosyl units are identified in human RCC samples based on the systematic study of their fragmentation behavior. Many of them are recorded here for the first time. Multivariate data analysis (MDA) methods, i.e., unsupervised principal component analysis (PCA) and supervised orthogonal partial least square discriminant analysis (OPLS-DA), are used for the visualization of differences between normal and tumor samples to reveal the most up- and downregulated lipids in tumor tissues. Obtained results are closely correlated with MALDI mass spectrometry imaging (MSI) and histologic staining. Important steps of the present MALDI-Orbitrap-MS approach are also discussed, such as the selection of best matrix, correct normalization, validation for semiquantitative study, and problems with possible isobaric interferences on closed masses in full scan mass spectra. .