Search NASA⌕ Search

SEARCH · Search NASA

Results for “OUTAGES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) Winter Intensive Operational Period: Aerodynamic Particle Sizer Field Campaign Report

An aerodynamic particle sizer spectrometer (APS, model 3321 by TSI Inc., Shoreview, Minnesota) was deployed at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Eastern North Atlantic (ENA) observatory during the second (winter) intensive operational period (IOP) of the Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) field campaign. Data were collected from January 9 through February 26, 2018, covering the second deployment of the ARM Aerial Facility (AAF) aircraft within ACE-ENA. The standard ENA instrument suite does not provide measurements of aerosol particle size distribution for diameters greater than one micron. Properties of coarse-mode (super-micron) aerosols are rarely measured, although super-micron particles can play an important role in the aerosol life cycle, affecting aerosol optical properties and cloud nuclei activity (e.g., Clarke et al. 2003). The APS was deployed to fill this gap in particle size measurements: it is capable of measuring size-resolved concentration of the aerosols in the 0.5-20 μm range (aerodynamic diameter). The APS was installed in the aerosol trailer to sample through the main stack. Special attention was given to selection of the instrument location (just below the main stack) to minimize particle losses in the connecting lines. Most atmospheric aerosols are hygroscopic, so the measurement of the aerosol size distributions should either be performed in a controlled humidity environment or accompanied by concurrent measurement of the temperature and humidity of the sample air. The latter strategy was used during this deployment: a high-precision humidity/temperature transmitter (model EE08 by E+E Elektonik GMBH, Engerwitzdorf, Germany) was mounted in the APS sampling line immediately upstream of the APS inlet. A dedicated laptop computer was used for data collection and communications. The APS was controlled with vendor-supplied software (Aerosol Instrument Manager, ver. 10.1, TSI); aerosol size distribution data were collected over a period of 55 seconds and converted to one-minute averages. Temperature and humidity analog signals were acquired via analog-to-digital converter (ADC) module (model WTAIN-M by Weeder Technologies, Fort Walton Beach, Florida) using vendor-supplied software (ModCom) with 1- sec resolution. In post-processing, the APS data were exported from TSI proprietary format into “comma-separated value” American Standard Code for Information Interchange (ASCII) files and matched with appropriately averaged temperature and humidity data. Two significant periods of missing data were caused by local power outages. Vendor-supplied software was not designed for unattended operation: it needs to be manually restarted including sensor configuration setup.

ACE-ENA, Azores, ultra-high-sensitivity aerosol sp↗

NREL + Verizon Wireless

Verizon Wireless and the National Renewable Energy Laboratory (NREL) are working to develop and validate a new design solution for telecommunications facilities. Network equipment is all DC, so rather than relying on conventional AC power, the design will employ photovoltaics (PV) and batteries, and it will require new DC cooling systems. The new design will ease utility interconnection by connecting PV to the DC bus and batteries, increase resiliency by allowing PV to contribute - and cooling to continue - in a power outage, lower costs with day-to-day utility cost savings, and increase efficiency through reduced part count and fewer power conversions from DC to AC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

NuScale Power Module Instrumentation

The safe and efficient operation of any nuclear power plant (NPP) depends on accurate and timely measurement of the primary system temperature, pressure, level, flow, and neutron flux. Integral pressurized water reactor (iPWR) or small modular reactors (SMRs) present unique challenges to instrumentation and control (I&C) sensors and their maintenance strategies. More specifically, the calibration and response time of these sensors may have to be verified periodically to ensure that they maintain their required degree of accuracy and speed of response. A review of technical reports and safety analysis documentation of the NuScale Power Module (NPM) by Analysis and Measurement Services Corporation (AMS), together with NuScale engineers, confirms that the I&C sensors within the NPM will need to be testable as installed to verify their static and dynamic performance at plant operating conditions. Sensor placement and installation as well as the process conditions expected in natural circulation integral SMRs like the NPM are very different from those in large scale NPPs with conventional primary system loop piping. In particular, reactor coolant system (RCS) flows are more complex and flow rates much lower, the average containment temperature is higher, nuclear radiation levels in some areas are greater, and the accessibility of sensors for hands-on maintenance is very limited. These challenges among others related to I&C sensors can be overcome by adapting existing I&C sensor test methods, developing new techniques for non-conventional I&C sensors, and incorporating online monitoring (OLM) technologies into the I&C architecture of the plant to verify the calibration and response time of sensors within the NPM prior to startup, during operation, and during subsequent refueling outages. These methods and technologies will be demonstrated and validated through a research and development (R&D) grant recently awarded to AMS by the U.S. Department of Energy (DOE) to facilitate timely deployment of the first NuScale SMR in the United States and to enable efficient I&C maintenance strategies during the life of the plant. Lastly, this paper presents the R&D plan for the DOE project with a focus on temperature measurement needs of NuScale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy Research at Idaho National Laboratory

Energy-related research at Idaho National Laboratory (INL) takes many forms. In this presentation, Liam Boire will step through a specific, on-going research project at INL which seeks to understand transmission grid resilience, and the components which can be improved to increase the resilience of our electrical infrastructure. While utilities and researchers similarly strive to improve power grid reliability, the frequency of large power outages are increasing. Thus, the importance for developing efficient methodologies that enable utilities and researchers alike to identify the most effective areas for improvement within the electric grid is more critical than ever. The method developed during this project recognized that a variety of factors were important to consider when identifying areas for improvement in the electric grid. Physics-based simulators are able to calculate voltage stability, load draws and generation capacities, and enumerate the combinations of component failures which result in system-wide failures (blackout scenarios). Probabilistic Risk Assessment (PRA) is able to assign probabilities to these failure scenarios based on typical component data (or more specific data if a specific system is being analyzed), and thus prioritize the list of failure scenarios based on likelihood and the components based on importance. Finally, adaptive capacity models can simulate the candidate grid and evaluate real and reactive power generation versus demand over time, calculating the total adaptive capacity available in various regions of the grid. The less adaptive capacity a region has, the less “buffer” that region has from failure. Not only are the individual results of these analyses valuable in understanding grid resilience, but the results of these analyses can be cross-correlated for deeper insight. When a grid is analyzed with this approach, failure scenarios can be enumerated and ranked by likelihood, components can be ranked by likelihood to drive system-wide failure, regions can be evaluated for adaptive capacity, and sensitive regions can be identified by recognizing the locations of important components within sensitive regions. Following this detailed discussion, a brief overview of some of the other energy research and areas of interest for the lab will be presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing Physical Layer Security for NOMA Transmission in mmWave Drone Networks

Note that the abstract was earlier approved with INL/CON-18-45291. This paper was provided after presentation of the material in the Asilomar conference. Physical layer security (PLS) is critically important for emerging wireless communication networks to maintain the confidentiality of the information of legitimate users. In this paper, we investigate enhancing PLS in an unmanned aerial vehicle (UAV) based communication network where a UAV acting as an aerial base station (BS) provides coverage in a densely packed user area (such as a stadium or a concert area). In particular, non-orthogonal multiple access (NOMA) together with highly-directional multi-antenna transmission techniques in mmWave frequency bands are utilized for improving spectral efficiency. In order to achieve PLS against potential eavesdropper attacks, we introduce a protected zone around the user region. However, limited resource availability refrain protected zone being extended to cover the entire eavesdropper region. Hence, we propose an approach to optimize the protected zone shape (for fixed area) at each UAV-BS hovering altitude. The associated secrecy performance is evaluated considering the secrecy outage and sum secrecy rates. Numerical results reveal the importance of protected zone shape optimization at each altitude to maximize NOMA secrecy rates. Index Terms—5G, drone, HPPP, mmWave, non-orthogonal multiple access (NOMA), physical layer security (PLS), UAV.

99 GENERAL AND MISCELLANEOUS↗

Protection Coordination of an Inverter Generation Based Microgrid for an Unbalanced Distribution System

In this paper we examine the protection issues that must be dealt with, to successfully operate a microgrid when the utility experiences a grid outage. Changes in fault current levels within microgrids under grid-tied and islanded conditions present challenges to developing robust and reliable protection schemes. These schemes must provide an effective response in both grid-connected and islanded mode and the transition between these modes. In this study, a section of an actual residential community located in the western part of the United States (U.S.) was considered as part of the microgrid evaluation. A sizing analysis was conducted to select the appropriate sizes of DER; simulated using DER-CAM analysis. The two DERs considered for the study included solar PV and Battery Energy Storage System (BESS). This paper highlights the protection coordination issues when an existing unbalanced distribution system encompassing a residential subdivision is converted into a microgrid with generation sources with low fault contribution. It further explains the strategy to coordinate protection devices during grid connected and islanded microgrid operating regimes.

Bello, Mobolaji↗

An Interdisciplinary Approach to Assessing Vulnerability of US Midwest to Drought and Heat Waves

More severe summer heat waves and droughts in the US Midwest and other regions due to climate change, along with changes in population distribution, pose risks for electricity shortages. Options are available for reducing these vulnerabilities. Costs and benefits of these options can be determined using a coupling of disparate analytical tools such as those that determine population allocation and climate variables to electricity service areas; tools that establish ranges of electricity demand and supply limitations and their modification in response to technological advances; and those that link water variables with power plant outages. A coupled system of this nature was used to examine the combined effects of heat wave and drought in the Midwest. Additionally, three adaptation scenarios based on changes in supply and demand for the greater Chicago, Illinois area were explored. We find that due to projected population changes in the region, the total number of metered customers approximately doubles by 2054, and that total electricity use increases 72% due to the population increase along with increases in maximum summer temperatures and frequency of heat waves in the region. Concomitantly, low availability of water during drought conditions, and high temperature effluent discharges during heat waves and higher overall temperatures, threaten operations for 30% of current power plant capacity reducing the supply at times of peak demand. As exhibited in one of the three adaptation scenarios, these conditions lead to an electricity supply deficit by 2054 and rapidly declining capacity margins during prior decades. However, technology additions, and changes in utility peak-period rates are available to modify customer demand substantially after 2024. Additionally, many water-cooled power plants near the end of their operational lives are projected to be replaced by more water-efficient generation.

Dumas, Melissa↗

Fairchilde Puppet Environment

The software creates a minimal directory organization structure and data isolation methods so that groups and projects are differentiated and isolated by levels in the hierarchy naming schemes. It also allows various versions of Puppet server and client to be used by different groups and projects so that groups can maintain their own upgrade and patching schedules without introducing breaking changes and unnecessary service outages to other groups using the framework.

Campfield, Michael P↗

Energy Exchange Pre-Conference Workshop: Distributed Energy Technologies for Resilience and Cost Savings

Distributed energy resources (DERs) include renewable energy (RE) technologies, storage, and combined heat and power (CHP). DERs can provide revenue streams and savings while grid connected. Savings may allow for the incorporation of additional microgrid components. When integrated into a microgrid, DERs can increase survival time during a grid outage when fuel supplies are limited.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

REopt: Enabling Renewable Energy, Storage, and Combined Heat and Power

Deployment of distributed energy resources including combined heat and power (CHP), photovoltaics (PV), and battery storage is growing as building and campus owners seek to reduce energy costs and increase resilience to grid outages. While deployment of a single technology is widespread, integrated systems of multiple technologies are also becoming more common to provide maximum economic and resilience benefits. To accelerate deployment, decision makers require tools to evaluate the technical and economic feasibility of these integrated systems. This paper presents a framework for optimizing the size and dispatch strategy of CHP with PV and battery storage to minimize life-cycle cost of energy. The modeling methodology is presented, with a particular focus on the linearization of cost and performance metrics required for implementation in a mixed integer linear program. A case study is used to examine the technical and economic viability of integrated CHP, PV, and battery systems, compared to CHP-only or PV+battery storage systems. In the case study we show how the integrated systems can provide increased economic and resilience benefits compared to single technologies on their own. The case study presented shows the combined CHP, PV, and battery system resulted in a 7% lower life cycle cost than CHP only, and a 22% lower life cycle cost than PV+battery storage. The life cycle emissions for CHP, PV, and battery storage resulted in a 24% reduction than CHP only and a 17% increase than PV+battery storage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Isotope Ratio Method Analysis of the WWR-SM Reactor

In this paper, we use the Isotope Ratio Method (IRM) to estimate the total energy production of the Uzbekistan Institute of Nuclear Physics WWR-SM research reactor. The isotope ratio method is a technique for verifying the operational history of a nuclear reactor by measuring trace element isotope ratios in non-fuel reactor components. The isotope ratios in these components can then be directly related to cumulative energy production with standard reactor modeling methods. This method has been successfully demonstrated on several shutdown reactors in the past. The WWR-SM is a 10MW pool reactor that has been operating since 1959. In 2013, a Pacific Northwest National Laboratory (PNNL) team successfully removed a surface sample from the aluminum core shroud during a refueling outage. The sample was subjected to Secondary Ionization Mass Spectrometry (SIMS) analysis at PNNL in 2014. Our results show good agreement with the actual operating history of the reactor.

Nuclear archeology, isotope ratio method, nonproli↗

Valuing Resilience in Electricity Systems

Recent natural disasters resulting in long-duration power outages have highlighted the United States increasing dependence on electricity, as well as the increasing vulnerability of the electric system. As utilities and system operators develop plans to upgrade current electricity systems and build new ones, they need ways to quantify, value, and monetize the resilience provided by different system designs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Embedded Optical Sensing Systems For Distribution Transformer Monitoring

Traditional utility monitoring systems do not provide real-time visibility into the condition of transformers or accurate performance measurements. This has resulted in the use of lagging indicators, such as oil sample analysis, typically requiring expensive field visits, grid outages, and laboratory sample testing. This presentation reviews the use of optical sensing systems for managing transformers and improving grid resiliency and safety. The sensing systems allow direct internal monitoring of critical transformer components. Versatility covering different monitoring parameters of interest in embedded configurations for new transformers and a retrofittable configuration for older transformers is achieved by applying hair-thin multiplexed fiber-optic and other low-profile optical sensors in combination with a high-resolution optical readout and advanced analytics. Under an initiative funded by the DOE Office of Electricity, PARC, GE and Con Edison built, tested, and qualified commercial network transformers with embedded optical sensing systems. The parameters monitored were validated across a range of scenarios with lab instruments typically used for qualification testing. An ongoing field trial to demonstrate the robustness of the technology for remote monitoring through the industrial internet under demanding grid deployment conditions in New York City is showing promise toward scale-up of the technology. This presentation will provide an overview of the typical pain points in managing transformers and parameters for monitoring. It will also cover the requirements for highly constrained installations that need to have a larger capacity and flexible rating but that must fit into a tight space. The unique capabilities of optical sensing systems and a low-cost approach to interpreting the signals from sensors in transformers for predictive maintenance will be covered. The presentation will discuss the compatibility of the sensors in the transformer environment. It will discuss the validation testing per IEEE standards that enabled the solution to be implemented in field-deployable commercial transformers. The initial results from the field deployment and the potential for the technology to provide systematic alerts for unsafe/unexpected events will be discussed. The technology could enable utility professionals to gain information they can use to better plan for maintenance/management, and improve grid performance. This would in turn accommodate DERs and other evolving grid market dynamics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Navy Ratchets Up Resilience Through Agency/Utility Collaboration

The Naval Construction Battalion Center (NCBC) in Gulfport, Mississippi, and Mississippi Power Company (MPC) have integrated a 15-acre solar photovoltaic (PV) array, battery storage, and backup generation with an innovative microgrid. The Navy and utility teams are helping ensure mission readiness at NCBC while increasing renewable energy generation on the grid in MPC's service area. The NCBC/MPC resilience effort will allow the base to more effectively deploy disaster recovery activities in the event of a grid outage.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Navy Ratchets Up Resilience Through Agency/Utility Collaboration

Fact sheet describes how the Naval Construction Battalion Center (NCBC) in Gulfport, Mississippi, and Mississippi Power Company (MPC) have integrated a 15-acre solar photovoltaic (PV) array, battery storage, and backup generation with an innovative microgrid to ensure mission readiness at NCBC while increasing renewable energy generation on the grid in MPC's service area. The NCBC/MPC resilience effort will allow the base to more effectively deploy disaster recovery activities in the event of a grid outage.

battery storage↗

Probabilistic Assessment of High-Renewables Power Systems: Current Work and Future Directions

In a future with higher penetrations of variable and energy-limited resources, the dominant sources of resource adequacy risk begin to shift from (assumed) independent thermal unit outages to spatially- and temporally-correlated weather-driven phenomena. Traditional resource adequacy assessment and planning methods can be ill-suited to such scenarios. This presentation will highlight aspects of NREL's work in adapting and developing new probabilistic methods and tools in anticipation of the needs of the power system planning exercises of tomorrow.

17 WIND ENERGY↗

Dynamic Distribution System Restoration Strategy for Resilience Enhancement: Preprint

In electric power distribution systems, distributed energy re-sources (DERs) can act as controllable power sources and support utility operators to minimize power outages after ex-treme weather events (e.g., hurricane, earthquake, wildfire) and thus help enhance the grid's resilience. Meanwhile, the influ-ences of extreme events and the capabilities of DERs are dy-namic and difficult to predict. Hence, the desired distribution system restoration strategy should be able to evolve according to real-time fault/disturbance information and the availabil-ity of DERs. In this paper, we propose a new dynamic distribu-tion system restoration strategy to enhance system resilience against potential hazards. An efficient reconfiguration algo-rithm is developed to eliminate the use of integer variables to relieve the computational burden. Model predictive control is implemented to adjust the system topology and DER opera-tion setpoints based on the updated fault information and DER forecasts. The effectiveness of the proposed restoration model in enhancing distribution system resilience is validated through an IEEE 123-bus test system. Simulation results also validate that the proposed restoration model can mitigate the occurrence of unexpected events and the fluctuations of DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Restoration Strategy for Distribution System Resilience Enhancement

In electric power distribution systems, distributed energy resources (DERs) can act as controllable power sources and support utility operators to minimize power outages after extreme weather events (e.g., hurricane, earthquake, wildfire) and thus help enhance the grid's resilience. Meanwhile, the influences of extreme events and the capabilities of DERs are dynamic and difficult to predict. Hence, the desired distribution system restoration strategy should be able to evolve according to real-time fault/disturbance information and the availability of DERs. In this paper, we propose a new dynamic restoration strategy for distribution systems to enhance system resilience against potential hazards. An efficient reconfiguration algorithm is developed to eliminate the use of integer variables to relieve the computational burden. Model predictive control is implemented to adjust the system topology and DER operation set points based on the updated fault information and DER forecasts. The effectiveness of the proposed restoration model in enhancing distribution system resilience is validated through an IEEE 123-bus test system. Simulation results also validate that the proposed restoration model can mitigate the occurrence of unexpected events and the fluctuations of DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗