Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operating mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Fermionic systems for quantum information people

The operator algebra of fermionic modes is isomorphic to that of qubits, the difference between them is twofold: the embedding of subalgebras corresponding to mode subsets and multiqubit subsystems on the one hand, and the parity superselection in the fermionic case on the other. We discuss these two fundamental differences extensively, and illustrate these through the Jordan–Wigner representation in a coherent, self-contained, pedagogical way, from the point of view of quantum information theory. Our perspective leads us to develop useful new tools for the treatment of fermionic systems, such as the fermionic (quasi-)tensor product, fermionic canonical embedding, fermionic partial trace, fermionic products of maps and fermionic embeddings of maps. We formulate these by direct, easily applicable formulas, without mode permutations, for arbitrary partitionings of the modes. It is also shown that fermionic reduced states can be calculated by the fermionic partial trace, containing the proper phase factors. We also consider variants of the notions of fermionic mode correlation and entanglement, which can be endowed with the usual, local operation based motivation, if the parity superselection rule is imposed. We also elucidate some other fundamental points, related to joint map extensions, which make the parity superselection inevitable in the description of fermionic systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design, construction and commissioning of the proximity cryogenics systems serving two large-scale prototypes of the future DUNE neutrino detector

In the context of the Neutrino Platform, CERN has designed, constructed, and commissioned the proximity cryogenics systems that serve two CERN based large-scale prototypes of future neutrino detectors. Each of these prototypes features a high voltage time projection chamber placed inside a membrane cryostat being submerged in 600m3 of liquid argon at about 1.0 bar. A copper and molecular sieve based cryogenic purification system has to ensure that the argon in the cryostat has a contamination level below 100 ppt oxygen equivalent. The two proximity cryogenics systems provide the purging, cool-down, filling, normal operation and emptying modes for each cryostat. This paper reports on the design, construction and commissioning of the ProtoDUNE proximity cryogenics facilities.

43 PARTICLE ACCELERATORS↗

Identification of two mechanisms for current production in a biharmonic flashing electron ratchet

Ratchets rectify the motion of randomly moving particles, which are driven by isotropic sources of energy such as thermal and chemical energy, without applying a net, time-averaged force between source and drain. We describe the behavior of a damped electron, modeled by a quantum Lindblad master equation, within a flashing ratchet (a one-dimensional potential that oscillates between a flat surface and a periodic asymmetric surface). By investigating the complete space of all biharmonic potential shapes and a large range of oscillation frequencies, two modes of ratchet operation, differentiated by their oscillation frequencies (relative to the rate of electron relaxation), are identified. Slow-oscillating, strong friction ratchets operate by a classical, overdamped mechanism. In fast-oscillating, weak friction ratchets, current is primarily produced when the frequency of the oscillating potential is resonant with the beating of the electron wave function in the potential well. The shape of the ratchet potential determines the direction of the current (and, in some cases, straightforwardly accounts for current reversals), but the maximum achievable current at any shape is controlled by the degree of friction applied to the electron.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generation of EM radiations using intense electron beam produced in vacuum

The results of a pulse power generator driving an axial virtual cathode oscillator are being presented in this paper as a source of high power microwave (HPM) radiations. The electron beam generator is also modified to attain the intense X-ray burst. The pulse power generator used for these applications is common and is having 10 ohms as its characteristic impedance with 50nS of pulse width. The peak charging voltage of the pulse forming line is 450 kV and hence 225 kV and 22.5 kA is peak voltage and peak current delivery capabilities respectively for the pulse power generator. The peak electrical power of the generator is 5GW for a matched load. The charging power supply for the pulse forming line consists of a high voltage generator made by pulse transformer and charging the pulse forming line in the first cycle of the charging pulse. To utilize the energy of the primary capacitive storage efficiently the pulse transformer is having 0.8 coupling coefficient between its primary and the secondary. The axial vircator chamber is evacuated to attain the vacuum of 2 x 10{sup -4} torr for the HPM application. In the case of modified electron beam chamber for the generation of X-rays the vacuum of same order is used. The pulse forming line is made using equal lengths of high voltage transmission lines, each having a length of 10 meters, connected in the parallel to give a net source impedance of 10 ohm. The pulse power generator can operate in repetitive mode and hence the HPM as well as X-rays may be generated in the repetitive burst. (author)

43 PARTICLE ACCELERATORS↗

Using a Grid-Forming Inverter to Stabilize a Low-Inertia Power System - Maui Hawaiian Island

As power systems around the world integrate greater amounts of wind and solar photovoltaic power, periods of very high instantaneous power shares of inverters, the primary interfacing technology for these generation sources, are complicating system stability and control. The contemporary, primary mode of inverter operation, grid-following, which explicitly assumes the presence of a local, stable voltage waveform, yields operational inadequacy at high instantaneous power shares potentially leading to instability due to the low-inertia conditions, as well as the correlated reduced voltage forming capacity on the respective system. Parallel connected grid-forming inverters, which directly regulate the local voltage, are a solution that is expected to bolster system stability and mitigate the shortcomings of the grid-following technology. In this paper, grid-following and two types of grid-forming inverter control, the traditional linear droop and the recently introduced nonlinear exponential droop (Droop-e), are simulated on a low-inertia, H = 0.48s, high inverter-based resource scenario, 97%, with a validated electromagentic transient domain model of the Hawaiian island of Maui power system. The benefit of a single grid-forming device over its grid-following counterpart is significant, both in terms frequency deviation and voltage stability. Further, the superiority of the Droop-e and the associated secondary power sharing control over both grid-following and linear droop grid-forming technologies is displayed, with improved nadir and rate of change of frequency over the linear droop control.

droop control↗

Comparison of simulated and experimentally measured detector impulse responses to pulsed x-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-toend performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributed Load Sharing Under False Data Injection Attack in an Inverter-Based Microgrid

In microgrids, distributed load sharing plays an important role in maintaining the supply-demand balance of power. Because false data injection (FDI) is one of the crucial threats faced by future microgrids, the study of the impact of FDI on distributed load sharing is both of theoretical merit and practical value. Here, we consider the distributed load sharing problem of the microgrids operating in autonomous mode under FDI. Each bus is assumed to be equipped with an agent. Under a well-developed distributed load sharing protocol based on multiagent systems, we first construct an FDI attack model, where the attacker is capable of injecting false data into the bus agents. Finally, a utilization level is introduced for coordinating generators, and its variation is evaluated in the presence of FDI attacks with given injection strategies. The stable region of the microgrid is defined, and conditions are given to determine stability. In conclusion, theoretical results are validated on the Canadian urban distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep Reinforcement Learning From Demonstrations to Assist Service Restoration in Islanded Microgrids

Microgrids can be operated in island mode during utility grid outages to support service restoration and improve system resilience. To schedule and dispatch distributed energy resources (DERs) in an islanded microgrid, conventional model-based methods rely on accurate distribution network models and lack generalization and adaptability. Data-driven methods are promising for DER coordination but face practical challenges such as potential hazards to microgrids during online training and insufficient online training opportunities due to low outage rates. This paper presents a novel two-stage learning framework that builds on the deep deterministic policy gradient from demonstrations to identify an optimal restoration strategy. At the pre-training stage, imitation learning is applied to equip the control agent with expert experiences to guarantee acceptable initial performance. At the online training stage, action clipping, reward shaping, and expert demonstrations are leveraged to ensure safe exploration while accelerating the training process. In conclusion, the proposed method is illustrated using the IEEE 123-node system and compared with a representative model-based method and the standard deep deterministic policy gradient method to prove solution accuracy and demonstrate increased computational efficiency.

Du, Yan↗

SiC MOSFET Based Modular Universal Power Electronics Regulator

A modular and scalable SiC MOSFET based universal power electronics regulator (UPER) allows coordinated integration of energy resources and loads, elimination of extra power conversion stages, and allowance of more sources or loads added with a simple plug and play feature. A comprehensive investigation has been conducted in term of the typical distributed generations and loads employed in buildings, in order to outline a detailed specification for UPER. Thus, a common DC bus voltage of 500 V and power rating of 3 kW are dedicatedly selected. The UPER hardware design and implementation are completely illustrated, including the static and dynamic characterization of the employed SiC MOSFET. The dedicated universal power cell and Plug-and-Play gate driver performs reliable continuous operation even exposed to an extreme fast switching speed (> 100 V/ns). The continuous operation of buck mode verified the UPER hardware development at 50 kHz with an overall efficiency of 98.19%. A new voltage polarity reversal phenomenon was also discovered in the verification of the isolated DAB stage with planar transformers.

Zheng, Sheng↗

In situ measurements of reactions in a glass-forming batch by X-ray and neutron diffraction

We report the batch materials used in glass production are often too coarse to allow phase evolution measurements by in situ high-temperature x-ray diffraction (HTXRD). Reducing the particle sizes to accommodate these measurements changes the reaction kinetics and can alter the reaction pathway. Unlike conventional laboratory XRD, which operates in reflection mode and analyzes the surface region of finely ground powder, neutron diffraction can be used to characterize as-received batch materials by means of an intense beam which penetrates through a bulk sample. In this study, the phase evolution in a glass-forming batch made with fine batch materials was probed in situ by both HTXRD and time-of-flight neutron diffraction to determine the similarities and differences between measurements by the two techniques. Therefore, the same composition, prepared using the coarser, as-received size distributions of the same batch materials, was studied by both techniques, demonstrating the unique capability of neutron diffraction to analyze material which is too coarse for the HTXRD, and to reveal the effect of the particle size distribution on the reaction kinetics.

36 MATERIALS SCIENCE↗

Novel strategy for low-temperature, high-rate growth of dense, hard, and stress-free refractory ceramic thin films

Growth of fully dense refractory thin films by means of physical vapor deposition (PVD) requires elevated temperatures T{sub s} to ensure sufficient adatom mobilities. Films grown with no external heating are underdense, as demonstrated by the open voids visible in cross-sectional transmission electron microscopy images and by x-ray reflectivity results; thus, the layers exhibit low nanoindentation hardness and elastic modulus values. Ion bombardment of the growing film surface is often used to enhance densification; however, the required ion energies typically extract a steep price in the form of residual rare-gas-ion-induced compressive stress. Here, the authors propose a PVD strategy for the growth of dense, hard, and stress-free refractory thin films at low temperatures; that is, with no external heating. The authors use TiN as a model ceramic materials system and employ hybrid high-power pulsed and dc magnetron co-sputtering (HIPIMS and DCMS) in Ar/N{sub 2} mixtures to grow dilute Ti{sub 1−x}Ta{sub x}N alloys on Si(001) substrates. The Ta target driven by HIPIMS serves as a pulsed source of energetic Ta{sup +}/Ta{sup 2+} metal–ions, characterized by in-situ mass and energy spectroscopy, while the Ti target operates in DCMS mode (Ta-HIPIMS/Ti-DCMS) providing a continuous flux of metal atoms to sustain a high deposition rate. Substrate bias V{sub s} is applied in synchronous with the Ta-ion portion of each HIPIMS pulse in order to provide film densification by heavy-ion irradiation (m{sub Ta} = 180.95 amu versus m{sub Ti} = 47.88 amu) while minimizing Ar{sup +} bombardment and subsequent trapping in interstitial sites. Since Ta is a film constituent, primarily residing on cation sublattice sites, film stress remains low. Dense Ti{sub 0.92}Ta{sub 0.08}N alloy films, 1.8 μm thick, grown with T{sub s} ≤ 120 °C (due to plasma heating) and synchronized bias, V{sub s} = 160 V, exhibit nanoindentation hardness H = 25.9 GPa and elastic modulus E = 497 GPa compared to 13.8 and 318 GPa for underdense Ti-HIPIMS/Ti-DCMS TiN reference layers (T{sub s} < 120 °C) grown with the same V{sub s}, and 7.8 and 248 GPa for DCMS TiN films grown with no applied bias (T{sub s} < 120 °C). Ti{sub 0.92}Ta{sub 0.08}N residual stress is low, σ = −0.7 GPa, and essentially equal to that of Ti-HIPIMS/Ti-DCMS TiN films grown with the same substrate bias.

36 MATERIALS SCIENCE↗

SU-F-BRE-11: Neutron Measurements Around the Varian TrueBeam Linac

Purpose: With the emergence of flattening filter free (FFF) photon beams, several authors have noted many advantages to their use. One such advantage is the decrease in neutron production by photonuclear reactions in the linac head. In the present work we investigate the reduction in neutrons from a Varian TrueBeam linac using the Nested Neutron Spectrometer (NNS, Detec). The neutron spectrum, total fluence and source strength were measured and compared for 10 MV with and without flattening filter and the effect of moderation by the room and maze was studied for the 15 MV beam. Methods: The NNS, similar to traditional Bonner sphere detectors but operated in current mode, was used to measure the neutron fluence and spectrum. The NNS was validated for use in high dose rate environments using Monte Carlo simulations and calibrated at NIST and NRC Canada. Measurements were performed at several positions within the treatment room and maze with the linac jaws closed to maximize neutron production. Results: The measurements showed a total fluence reduction between 35-40% in the room and maze when the flattening filter was removed. The neutron source strength Qn was calculated from in-room fluence measurements and was found to be 0.042 × 10{sup 2} n/Gy, 0.026 × 10{sup 2} n/Gy and 0.59 × 101{sup 2} n/Gy for the 10 MV, the 10 MV FFF and 15 MV beams, respectively. We measured ambient equivalent doses of 11 mSv/hr, 7 mSv/hr and 218 mSv/hr for the 10 MV, 10 MV FFF and 15 MV by the head. Conclusion: Our measurements revealed a decrease in total fluence, neutron source strength and equivalent dose of approximately 35-40% across the treatment room for the FFF compared to FF modes. This demonstrates, as expected, that the flattening filter is a major component of the neutron production for the TrueBeam. The authors greatly acknowledge support form the Canadian Nuclear Commission and the Natural Sciences and Engineering Research Council of Canada through the CREATE program. Co-authors Dubeau and Witharana are employees of Detec (Gatineau, Quebec), manufacturer of the Nested Neutron Spectrometer.

07 ISOTOPE AND RADIATION SOURCES↗

TH-C-19A-02: Characterization of An Actively Controlled Graphite Probe Calorimeter

Purpose: To construct and experimentally evaluate the performance of a miniature probe-format graphite calorimeter (GPC) with built-in active control. The GPC is the first ever calorimeter designed specifically for routine clinical use. Methods: The original GPC design, developed as part of our previous work, was modified to accommodate a micro-thin, resistive heating element and sensing thermistors embedded in the outermost graphite layer. A software-based process control loop was written to maintain a predefined set point temperature throughout the detector by precisely modulating the current flowing through the resistive element. Continuous feedback is provided to the controller by the additional thermistors. A functioning prototype was constructed in-house and operated in adiabatic mode in a 6 MV photon beam. Ten sets of measurements of varying duration (10 to 60 seconds) and repetition rate (200 to 600 MU/min) were analyzed. Reproducibility, linearity and dose rate dependence were assessed. Results: A total of 47 individual measurements were performed using the active GPC. The reproducibility, defined here as the sample standard deviation weighted across all 10 measurement sets, was found to be 0.37%. Similarly, the standard error (type A uncertainty) was 0.17%. Linearity was quantified by plotting signal as a function of monitor units delivered at 600 MU/min. The adjusted R-square of the resulting linear fit was 0.9996. Dose rate dependence, evaluated as the change in normalized response (signal/MU) as a function of repetition rate, was found to be statistically insignificant. Conclusions: The incorporation of active control has resulted in a marked improvement in the GPC's reproducibility and it allows the user to now perform measurements within minutes of setup. With this refinement, it is estimated that the overall standard uncertainty in the absolute determination of dose to water is 1%, making the GPC comparable to a calibrated ionization chamber. This research has received financial support from Sun Nuclear Corporation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sci—Fri PM: Dosimetry—02: A Nested Neutron Spectrometer to Measure Neutron Spectra in Radiotherapy

During high-energy radiotherapy treatments, neutrons are produced in the head of the linac through photonuclear interactions. This has been a concern for many years as photoneutrons contribute to the accepted, yet unwanted, out-of-field doses that pose an iatrogenic risk to patients and an occupational risk to personnel. Presently, in-room neutron measurements are difficult and time-consuming and have traditionally been carried out using Bonner spheres with activation foils and TLDs. In this work, a new detector, the Nested Neutron Spectrometer (NNS) is tested for use in radiotherapy bunkers. The NNS is designed for easy handling and is more practical than the traditional Bonner spheres. The NNS, operated in current mode, was used to measure the dose equivalent, average energy and energy spectrum at several positions in a radiotherapy bunker. The average energy and spectra were compared to Monte Carlo simulations while the dose equivalent was compared to bubble detector measurements. The average energies, as measured by the NNS and Monte Carlo simulations, differed by approximately 30% across the bunker. Measurements of the dose equivalent using the NNS and the bubble detectors agreed within 50% in the maze and less than 10% close to the linac head. Apart from some discrepancies at thermal energies, we also found reasonable agreement between NNS-measured and Monte Carlo-simulated spectra at a number of locations within our radiotherapy bunker. Our results demonstrate that the NNS is a suitable detector to be used in high dose-rate radiotherapy environments.

07 ISOTOPE AND RADIATION SOURCES↗

Registration of clinical volumes to beams-eye-view images for real-time tracking

Purpose: The authors combine the registration of 2D beam’s eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). Methods: During treatment of lung SBRT cases, BEV images were continuously acquired with an electronic portal imaging device (EPID) operating in cine mode. For absolute registration of physician-defined volumes, an intensity based 2D/3D registration to the planning CT was performed using the end-of-exhale (EoE) phase of the four dimensional computed tomography (4DCT). The volume was converted from Hounsfield units into electron density by a calibration curve and digitally reconstructed radiographs (DRRs) were generated for each beam geometry. Using normalized cross correlation between the DRR and an EoE BEV image, the best in-plane rigid transformation was found. The transformation was applied to physician-defined contours in the planning CT, mapping them into the EPID image domain. A robust multiregion method of relative markerless lung tumor tracking quantified deviations from the EoE position. Results: The success of 2D/3D registration was demonstrated at the EoE breathing phase. By registering at this phase and then employing a separate technique for relative tracking, the authors are able to successfully track target volumes in the BEV images throughout the entire treatment delivery. Conclusions: Through the combination of EPID/4DCT registration and relative tracking, a necessary step toward the clinical implementation of BEV tracking has been completed. The knowledge of tumor volumes relative to the treatment field is important for future applications like real-time motion management, adaptive radiotherapy, and delivered dose calculations.

60 APPLIED LIFE SCIENCES↗

SU-E-P-15: Technique Factor Modulation and Reference Plane Air Kerma Rates in Response to Simulated Patient Thickness Variations for a Sample of Current Generation Fluoroscopes

Purpose: To evaluate and compare approaches to technique factor modulation and air kerma rates in response to simulated patient thickness variations for four state-of-the-art and one previous-generation interventional fluoroscopes. Methods: A polymethyl methacrylate (PMMA) phantom was used as a tissue surrogate for the purposes of determining fluoroscopic reference plane air kerma rates, kVp, mA, and spectral filtration over a wide range of simulated tissue thicknesses. Data were acquired for each fluoroscopic and acquisition dose curve within a default abdomen or body imaging protocol. Results: The data obtained indicated vendor- and model-specific variations in the approach to technique factor modulation and reference plane air kerma rates across a range of tissue thicknesses. Some vendors have made hardware advances increasing the radiation output capabilities of their fluoroscopes; this was evident in the acquisition air kerma rates. However, in the imaging protocol evaluated, all of the state-of-the-art systems had relatively low air kerma rates in the fluoroscopic low-dose imaging mode as compared to the previous-generation unit. Each of the newest-generation systems also employ copper filtration in the selected protocol in the acquisition mode of imaging; this is a substantial benefit, reducing the skin entrance dose to the patient in the highest dose-rate mode of fluoroscope operation. Conclusion: Understanding how fluoroscopic technique factors are modulated provides insight into the vendor-specific image acquisition approach and provides opportunities to optimize the imaging protocols for clinical practice. The enhanced radiation output capabilities of some of the fluoroscopes may, under specific conditions, may be beneficial; however, these higher output capabilities also have the potential to lead to unnecessarily high dose rates. Therefore, all parties involved in imaging, including the clinical team, medical physicists, and imaging vendors, must work together to ensure that adequate but not excessive radiation doses are used.

60 APPLIED LIFE SCIENCES↗

SU-F-T-511: Feasibility Study of Using Flattening-Filter-Free Photon Beams to Deliver Conventional Flat Beam

Purpose: Various dosimetric benefits such as increased dose rate, and reduced leakage and out of field dose has led to the growth of FFF technology in the clinic. In this study, we concentrate on investigating the feasibility of using flattening-filter-free (FFF) beams to deliver conventional flat beams (CFB), since completely getting rid of the flattening-filter module from the gantry head can not only simplify the gantry design but also decrease the workload on machine maintain and quality assurance. Methods: The sliding window based IMRT technique was utilized to generate the CFB from the FFF beam for various beam configurations on the Elekta Versa HD. The flat beam reproducibility and MU efficiency were compared for each beam configuration among FFF planning, delivery and CFB planning. Results: Compared to the CFB plan, the 3%3mm passing rates of the FFF beams from both measurement and plan are 100% and 95%(or better) for 15×15 cm{sup 2} or smaller field size and for any field size greater than 15×15 cm{sup 2}at 10 cm depth, respectively. The largest discrepancy is about 5% and typically appears at the field shoulder area. The MU increase average was 80% for FFF compared to CFB, however has a minimal impact on treatment delivery time. Conclusion: The ability to deliver conventional flat treatments is not absent when operating in FFF mode. With proper TPS manipulation and beam modulation, FFF mode can achieve reasonable flat profiles and comparable dose coverage as CFB does for various conventional treatment techniques, such as four field box, or long spine treatment techniques. The ability to deliver most clinical treatments from the same treatment unit, will allow for less quality assurance as well as maintenance, and completely eliminate the need for the flattening filter on modern linacs.

60 APPLIED LIFE SCIENCES↗

Poster - 30: Use of a Hazard-Risk Analysis for development of a new eye immobilization tool for treatment of choroidal melanoma

Purpose: Our treatment for choroidal melanoma utilizes the GTC frame. The patient looks at a small LED to stabilize target position. The LED is attached to a metal arm attached to the GTC frame. A camera on the arm allows therapists to monitor patient compliance. To move to mask-based immobilization we need a new LED/camera attachment mechanism. We used a Hazard-Risk Analysis (HRA) to guide the design of the new tool. Method: A pre-clinical model was built with input from therapy and machine shop personnel. It consisted of an aluminum frame placed in aluminum guide posts attached to the couch top. Further development was guided by the Department of Defense Standard Practice - System Safety hazard risk analysis technique. Results: An Orfit mask was selected because it allowed access to indexes on the couch top which assist with setup reproducibility. The first HRA table was created considering mechanical failure modes of the device. Discussions with operators and manufacturers identified other failure modes and solutions. HRA directed the design towards a safe clinical device. Conclusion: A new immobilization tool has been designed using hazard-risk analysis which resulted in an easier-to-use and safer tool compared to the initial design. The remaining risks are all low probability events and not dissimilar from those currently faced with the GTC setup. Given the gains in ease of use for therapists and patients as well as the lower costs for the hospital, we will implement this new tool.

60 APPLIED LIFE SCIENCES↗