Search NASA⌕ Search

SEARCH · Search NASA

Results for “Packaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Development of integrated radioactive waste packaging and conditioning solutions in the UK

In order to offer a more cost effective, safer and efficient Intermediate Level Waste (ILW) management service, EnergySolutions EU Ltd. and Gesellschaft fur Nuklear-Service mbH (GNS) have been engaged in the development of integrated radioactive waste retrieval, packaging and conditioning solutions in the UK. Recognising the challenges surrounding regulatory endorsement and on-site implementation in particular, this has resulted in an alternative approach to meeting customer, safety regulator and disposability requirements. By working closely with waste producers and the organisation(s) responsible for endorsing radioactive waste management operations in the UK, our proposed solutions are now being implemented. By combining GNS' off-the-shelf, proven Ductile Cast Iron Containers (DCICs) and water removal technologies, with EnergySolutions EU Ltd.'s experience and expertise in waste retrieval, safety case development and disposability submissions, a fully integrated service offering has been developed. This has involved significant effort to overcome technical challenges such as onsite equipment deployment, active commissioning, conditioning success criteria and disposability acceptance. Our experience in developing such integrated solutions has highlighted the importance of working in collaboration with all parties to achieve a successful and viable outcome. Ultimately, the goal is to ensure reliable, safe and effective delivery of waste management solutions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Open-Source Python Package for CFD Solution Verification

Informed decision-making using computational fluid dynamics (CFD) results requires quantifying the errors and uncertainties of a simulation. Verification, validation, and uncertainty quantification (VVUQ) methods were developed to address this need and have matured. However, these VVUQ analyses are often non-trivial and require CFD analysts and practitioners to have specific skill sets. This has led to the uneven adoption of VVUQ analyses, in part, based on the availability of software tools to aid CFD analysts and practitioners. Solution verification, a procedure to evaluate the accuracy of a simulation by estimating potential errors arising from the computational model and computing the uncertainties without comparing to results from a physical system, is one of the lagging VVUQ analyses as the absence of software has forced CFD analysts and practitioners to develop their own codes or piece together incomplete software from across the internet. This work presents an opensource Python package, CFDverify, to lower the barrier of entry and fill in the technological gap in solution verification. CFDverify also provides a streamlined framework to remove some potential errors in post-processing CFD results. The hope is that CFDverify can improve the quality and quantity of CFD solution verification in scientific and research studies and attract interest in developing a communal tool. This paper describes the design, features, and an example use of CFDverify.

Weinmeister, Justin [ORNL] (ORCID:0000000160090237↗

SU-E-I-02: A Framework to Perform Batch Simulations of Computational Voxel Phantoms to Study Organ Doses in Computed Tomography Using a Commercial Monte Carlo Software Package

Purpose: ImpactMC (CT Imaging, Erlangen, Germany) is a Monte Carlo (MC) software package that offers a GPU enabled, user definable and validated method for 3D dose distribution calculations for radiography and Computed Tomography (CT). ImpactMC, in and of itself, offers limited capabilities to perform batch simulations. The aim of this work was to develop a framework for the batch simulation of absorbed organ dose distributions from CT scans of computational voxel phantoms. Methods: The ICRP 110 adult Reference Male and Reference Female computational voxel phantoms were formatted into compatible input volumes for MC simulations. A Matlab (The MathWorks Inc., Natick, MA) script was written to loop through a user defined set of simulation parameters and 1) generate input files required for the simulation, 2) start the MC simulation, 3) segment the absorbed dose for organs in the simulated dose volume and 4) transfer the organ doses to a database. A demonstration of the framework is made where the glandular breast dose to the adult Reference Female phantom, for a typical Chest CT examination, is investigated. Results: A batch of 48 contiguous simulations was performed with variations in the total collimation and spiral pitch. The demonstration of the framework showed that the glandular dose to the right and left breast will vary depending on the start angle of rotation, total collimation and spiral pitch. Conclusion: The developed framework provides a robust and efficient approach to performing a large number of user defined MC simulations with computational voxel phantoms in CT (minimal user interaction). The resulting organ doses from each simulation can be accessed through a database which greatly increases the ease of analyzing the resulting organ doses. The framework developed in this work provides a valuable resource when investigating different dose optimization strategies in CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-201-06: Utility of Quantitative 3D SPECT/CT Imaging in Patient Specific Internal Dosimetry of 153-Samarium with GATE Monte Carlo Package

Purpose: Patient-specific 3-dimensional (3D) internal dosimetry in targeted radionuclide therapy is essential for efficient treatment. Two major steps to achieve reliable results are: 1) generating quantitative 3D images of radionuclide distribution and attenuation coefficients and 2) using a reliable method for dose calculation based on activity and attenuation map. In this research, internal dosimetry for 153-Samarium (153-Sm) was done by SPECT-CT images coupled GATE Monte Carlo package for internal dosimetry. Methods: A 50 years old woman with bone metastases from breast cancer was prescribed 153-Sm treatment (Gamma: 103keV and beta: 0.81MeV). A SPECT/CT scan was performed with the Siemens Simbia-T scanner. SPECT and CT images were registered using default registration software. SPECT quantification was achieved by compensating for all image degrading factors including body attenuation, Compton scattering and collimator-detector response (CDR). Triple energy window method was used to estimate and eliminate the scattered photons. Iterative ordered-subsets expectation maximization (OSEM) with correction for attenuation and distance-dependent CDR was used for image reconstruction. Bilinear energy mapping is used to convert Hounsfield units in CT image to attenuation map. Organ borders were defined by the itk-SNAP toolkit segmentation on CT image. GATE was then used for internal dose calculation. The Specific Absorbed Fractions (SAFs) and S-values were reported as MIRD schema. Results: The results showed that the largest SAFs and S-values are in osseous organs as expected. S-value for lung is the highest after spine that can be important in 153-Sm therapy. Conclusion: We presented the utility of SPECT-CT images and Monte Carlo for patient-specific dosimetry as a reliable and accurate method. It has several advantages over template-based methods or simplified dose estimation methods. With advent of high speed computers, Monte Carlo can be used for treatment planning on a day to day basis.

60 APPLIED LIFE SCIENCES↗

Recycling of multilayer plastic packaging materials by solvent-targeted recovery and precipitation

Many plastic packaging materials manufactured today are composites made of distinct polymer layers (i.e., multilayer films). Billions of pounds of these multilayer films are produced annually, but manufacturing inefficiencies result in large, corresponding postindustrial waste streams. Although relatively clean (as opposed to municipal wastes) and of near-constant composition, no commercially practiced technologies exist to fully deconstruct postindustrial multilayer film wastes into pure, recyclable polymers. Here, we demonstrate a unique strategy we call solvent-targeted recovery and precipitation (STRAP) to deconstruct multilayer films into their constituent resins using a series of solvent washes that are guided by thermodynamic calculations of polymer solubility. We show that the STRAP process is able to separate three representative polymers (polyethylene, ethylene vinyl alcohol, and polyethylene terephthalate) from a commercially available multilayer film with nearly 100% material efficiency, affording recyclable resins that are cost-competitive with the corresponding virgin materials.

36 MATERIALS SCIENCE↗

BRCore: an R package implementing flexible selection of core taxa using contribution to Bray-Curtis dissimilarity and neutral model fitting

Identifying core taxa in microbial ecology highlights groups likely to participate in a broad range of potential ecological interactions. Here, we present BRCore, an R package to identify core taxa using abundance-occupancy distributions and beta-diversity contributions across ecological niches, and predict stochastic and deterministic taxa.

59 BASIC BIOLOGICAL SCIENCES↗

A package for renormalization group running in the SMEFT with sterile neutrinos

Abstract Sterile neutrinos are well-motivated beyond the Standard Model (BSM) particles. The Standard Model Effective Field Theory (SMEFT) augmented with these new fields is known as the $$\nu $$ ν SMEFT. We present the first code for solving the renormalization group equations (RGEs) of the $$\nu $$ ν SMEFT in an automated way. For this purpose, we have implemented the $$\nu $$ ν SMEFT as a new effective field theory (EFT) in the Wilson coefficient exchange format . Furthermore, we included anomalous dimensions depending on the gauge couplings and Yukawas in the python package . This novel version of allows a consistent inclusion of $$\nu $$ ν SMEFT renormalization group (RG) running effects above the electroweak (EW) scale in phenomenological studies involving sterile neutrinos. Moreover, this new release allows us to study EW, strong, and Yukawa running effects separately within the SMEFT.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ArQTiC: A Full-stack Software Package for Simulating Materials on Quantum Computers

ArQTiC is an open-source, full-stack software package built for the simulations of materials on quantum computers. It currently can simulate materials that can be modeled by any Hamiltonian derived from a generic, one-dimensional, time-dependent Heisenberg Hamiltonian. ArQTiC includes modules for generating quantum programs for real- and imaginary-time evolution, quantum circuit optimization, connection to various quantum backends via the cloud, and post-processing of quantum results. By enabling users to seamlessly design, execute, and analyze materials simulations on quantum computers, ArQTiC opens this field to a broader community of scientists from a wider range of scientific domains.

97 MATHEMATICS AND COMPUTING↗

A software package for plasma facing component analysis and design: the Heat flux Engineering Analysis Toolkit (HEAT)

The engineering limits of plasma facing components (PFCs) constrain the allowable operational space of tokamaks. Poorly managed heat fluxes that push the PFCs beyond their limits not only degrade core plasma performance via elevated impurities, but can also result in PFC failure due to thermal stresses or melting. Simple axisymmetric assumptions fail to capture the complex interaction between 3D PFC geometry and 2D or 3D plasmas. This results in fusion systems that must either operate with increased risk or reduce PFC loads, potentially through lower core plasma performance, to maintain a nominal safety factor. High precision 3D heat flux predictions are necessary to accurately ascertain the state of a PFC given the evolution of the magnetic equilibrium. A new code, the Heat flux Engineering Analysis Toolkit (HEAT), has been developed to provide high precision 3D predictions and analysis for PFCs. HEAT couples many otherwise disparate computational tools together into a single open source python package. Magnetic equilibrium, engineering CAD, finite volume solvers, scrape off layer plasma physics, visualization, high performace computing, and more, are connected in a single web-based user interface. Linux users may use HEAT without any software prerequisites via an appImage. This manuscript introduces HEAT, discusses the software architecture, presents first HEAT results, and outlines physics modules in development.

divertor physics↗

Amesos Solver Package

Amesos is the Direct Sparse Solver Package in Trilinos. The goal of Amesos is to make AX=S as easy as it sounds, at least for direct methods. Amesos provides interfaces to a number of third party sparse direct solvers, including SuperLU, SuperLU MPI, DSCPACK, UMFPACK and KLU. Amesos provides a common object oriented interface to the best sparse direct solvers in the world. A sparse direct solver solves for x in Ax = b. where A is a matrix and x and b are vectors (or multi-vectors). A sparse direct solver flrst factors A into trinagular matrices L and U such that A = LU via gaussian elimination and then solves LU x = b. Switching amongst solvers in Amesos roquires a change to a single parameter. Yet, no solver needs to be linked it, unless it is used. All conversions between the matrices provided by the user and the format required by the underlying solver is performed by Amesos. As new sparse direct solvers are created, they will be incorporated into Amesos, allowing the user to simpty link with the new solver, change a single parameter in the calling sequence, and use the new solver. Amesos allows users to specify whether the matrix has changed. Amesos can be used anywhere that any sparse direct solver is needed.

SciDAC↗

graphMC: A package for testing the independence of graphs

graphMC consists of an implementation of a set of statistical tests that ensure that a Markov chain in the space of graphs has converged to its stationary distribution. The tests are applicable when the graphs have labelled nodes. The tests are applied to the binary time-series traced out by an edge between two selected nodes. The software fits models of a first-order Markov process and an independent draws from a binary distribution to the time-series and selects one based on the BIC scores of the two models. The package consists of (1) an implementation of a Markov chain driving a graph rewiring process that preserves the joint degree distribution of the graph, (2) implementation of the statistical test mentioned above and (3) two examples that show how the Markov chain infrastructure and the statistical tests can be used.

Safta, Cosmin↗

Generalized Interaction Data Interface and associated packages

GIDIplus contains libraries for reading and using GNDS-formatted nuclear data. It includes sub-packages GIDI, MCGIDI, PoPs, numerical Functions and status Message Reporting along with scripts for building and installing the entire library.

Beck, Bret↗

EQ3/6 A Software Package for Geochemical Modeling

EQ3/6 is a software package for modeling geochemical interactions between aqueous solution, solids, and gases, following principles of chemical thermodynamics and chemical kinetics. It is useful for interpreting aqueous solution chemical compositions and for calculating the consequences of reaction of such solutions with minerals, other solids, and gases. It is designed to run in a command line environment. EQPT is a thermodynamic data file preprocessor. EQ3NR is a speciation-solubility code. EQ6 is a reaction path code.

Wolery, T.J.↗

Bethe-Salpeter Eigenvalue Solver Package (BSEPACK) v0.1

The BSEPACK contains a set of subroutines for solving the Bethe-Salpeter Eigenvalue (BSE) problem. This type of problem arises in this study of optical excitation of nanoscale materials. The BSE problem is a structured non-Hermitian eigenvalue problem. The BSEPACK software can be used to compute all or subset of eigenpairs of a BSE Hamiltonian. It can also be used to compute the optical absorption spectrum without computing BSE eigenvalues and eigenvectors explicitly. The package makes use of the ScaLAPACK, LAPACK and BLAS.

SHAO, MEIYUE↗

GENESPACE R Package (GENESPACE) v1.0

In short, the GENESPACE pipeline conducts analysis of orthology networks, constrained within syntenic regions. Since analyses are limited to local tests conducted within syntenic blocks, GENESPACE is agnostic to ploidy, duplicated regions, inversions or other whole-genome chromosomal complexities that are common across many evolutionary lineages. This advantage allows for evolutionary tests in polyploids (e.g. switchgrass, manuscript in review), species with ancient, but retained whole-genome duplications (e.g. pecan, manuscript in prep), high levels of tandem array proliferation (e.g. eukalypts, manuscript in review) and many other factors that can confound comparative genomic analyses. The major advances of GENESPACE are three-fold: First, this is the first R package to integrate visualization and analysis of large-scale comparative genomics. R, which offers a high-level environment for graphical and statistical exploration of data, is often speed- and memory-limited and not used for computationally intensive tasks such as comparative genomics. The highly efficient C++ scripts used in GENESPACE (via data.table) permit a much faster and computationally lightweight implementation of comparative genomics than is currently available. Second, the pipeline itself is novel. To the best of our knowledge, no other program accomplishes synteny-constrained and ploidy-agnostic comparative genomics. Since nearly all plants and many animals have a history of whole-genome duplications, this is a major and necessary advance to the field. Third, GENESPACE offers high-level and intuitive multi-genome graphical outputs. The dotplots and 'riparian' plots produced herein, which are produced entirely through original R code, are publication-ready and easily customizable.

Schmutz, Jeremy↗

Standard Behaviors - Umbra Package

This package contains the standard commands that characters can perform within the Umbra simulation framework, including the managers and supporting behaviors which enable commands to be initialized and simulated. Commands can be specified for a list of characters or a team. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-3055 O

Hart, BrianE.↗

Methodology for Automated Detection of Degradation and Faults in Packaged Air Conditioners and Heat Pumps Using Only Two Sensors

The software was created in the process of developing a system known as the Smart Monitoring and Diagnostic System (SMDS) for packaged air conditioners and heat pumps used on commercial buildings (known as RTUs). The SMDS provides automated remote monitoring and detection of performance degradation and faults in these RTUs and could increase the awareness by building owners and maintenance providers of the condition of the equipment, the cost of operating it in degraded condition, and the quality of maintenance and repair service when it is performed. The SMDS provides these capabilities and would enable conditioned-based maintenance rather than the reactive and schedule-based preventive maintenance commonly used today, when maintenance of RTUs is done at all. Improved maintenance would help ensure persistent peak operating efficiencies, reducing energy consumption by an estimated 10% to 30%.

Source record↗