Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Iridium in sediments containing large abundances of Australasian microtektites from DSDP hole 758B in the Eastern Indian Ocean and from DSDP hole 769A in the Sulu Sea

Excess Ir found in sediments at the Cretaceous/Tertiary (K/T) boundary and in other (e.g., Pliocene) sediments from deep sea drilling cores is widely interpreted as evidence of major impact events. The Australasian tektites originated in an impact event approximately 0.77 Ma ago; microtektites have been found in deep-sea sediment cores from throughout the Indian Ocean, the Philippine Sea, and western Pacific Ocean, but Ir has not been previously reported in these horizons. The deep-sea record of tektites is of particular interest, because in contrast to most continental occurrences, the stratigraphy preserves the original depositional position. Recently several cores having exceptionally high contents of Australasian microtektites have been investigated, Glass and Wu found shocked quartz associated with the microtektites. We used neutron activation to determine concentrations of Ir and other elements in two cores bearing microtektites, one from Deep Sea Drilling Project (DSDP) hole 758B in the Eastern Indian Ocean and one from DSDP hole 769A in the Sulu Sea (near Mindanao, Philippines). The sedimentation age for the microtektite layers in core 758B lies between 0.73 - 0.78 Ma and agrees well with the mean laser-fusion Ar-40/Ar-39 age of Australasian tektites of 0.77 +/- 0.02 Ma by Izett et al. We are able to resolve a small positive Ir enhancement in 758B. Core 769A shows too much scatter to allow resolution of an Ir peak.

Schmidt, Gerhard↗

Rosat observation of the 4U 1543-47 outburst in 1992

Observation of 4U 1543-47 (HL Lupi) with the Rosat satellite on 21 Aug. 1992 with the PSPC (Position Sensitive Proportional Counter) and on 4 Sep. 1992 with the HRI (High Resolution Imager), four and five months after the soft X-ray transient outburst, respectively, is reported. Both observations revealed the source to be much brighter than expected from the decay rate at harder X-rays (deduced from BATSE (Gamma Ray Burst (GRB) instrument team for the Compton Gamma Ray Observatory) data). BATSE observations in Aug. 1992 do not show any significant increase in the hard X-ray flux, suggesting that the soft and hard X-ray fluxes are either decoupled or anticorrelated to some degree.

Greiner, J.↗

Synthetic-Aperture Coherent Imaging From A Circular Path

Imaging algorithms based on exact point-target responses. Developed for use in reconstructing image of target from data gathered by radar, sonar, or other transmitting/receiving coherent-signal sensory apparatus following circular observation path around target. Potential applications include: Wide-beam synthetic-aperture radar (SAR) from aboard spacecraft in circular orbit around target planet; SAR from aboard airplane flying circular course at constant elevation around central ground point, toward which spotlight radar beam pointed; Ultrasonic reflection tomography in medical setting, using one transducer moving in circle around patient or else multiple transducers at fixed positions on circle around patient; and Sonar imaging of sea floor to high resolution, without need for large sensory apparatus.

Jin, Michael Y.↗

Investigation of water vapor motion winds from geostationary satellites

Water vapor imagery from geostationary satellites has been available for over a decade. These data are used extensively by operational analysts and forecasters, mainly in a qualitative mode (Weldon and Holmes 1991). In addition to qualitative applications, motions deduced in animated water vapor imagery can be used to infer wind fields in cloudless regimes, thereby augmenting the information provided by cloud-drift wind vectors. Early attempts at quantifying the data by tracking features in water vapor imagery met with modest success (Stewart et al. 1985; Hayden and Stewart 1987). More recently, automated techniques have been developed and refined, and have resulted in upper-level wind observations comparable in quality to current operational cloud-tracked winds (Laurent 1993). In a recent study by Velden et al. (1993) it was demonstrated that wind sets derived from Meteosat-3 (M-3) water vapor imagery can provide important environmental wind information in data void areas surrounding tropical cyclones, and can positively impact objective track forecasts. M-3 was repositioned to 75W by the European Space Agency in 1992 in order to provide complete coverage of the Atlantic Ocean. Data from this satellite are being transmitted to the U.S. for operational use. Compared with the current GOES-7 (G-7) satellite (positioned near 112W), the M-3 water vapor channel contains a superior horizontal resolution (5 km vs. 16 km ). In this paper, we examine wind sets derived using automated procedures from both GOES-7 and Meteosat-3 full disk water vapor imagery in order to assess this data as a potentially important source of large-scale wind information. As part of a product demonstration wind sets were produced twice a day at CIMSS during a six-week period in March and April (1994). These data sets are assessed in terms of geographic coverage, statistical accuracy, and meteorological impact through preliminary results of numerical model forecast studies.

Velden, Christopher S.↗

First Astronomical Use Of Multiplexed Transition Edge Bolometers

We present performance results based on the first astronomical use of multiplexed superconducting bolometers. The Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE) is a broadband submillimeter spectrometer that achieved first light in June 2001 at the Caltech Submillimeter Observatory (CSO). FIBRE's detectors are superconducting transition edge sensor (TES) bolometers read out by a SQUID multiplexer. The Fabry-Perot uses a low resolution grating to order sort the incoming light. A linear bolometer array consisting of 16 elements detects this dispersed light, capturing five orders simultaneously from one position on the sky. With tuning of the Fabry-Perot over one free spectral range, a spectrum covering delta-lamda/lamda = 1/7 at a resolution of delta-lamda/lamda = 1/1200 can be acquired. This spectral resolution is sufficient to resolve doppler broadened line emission from external galaxies. FIBRE operates in the 350 micrometer and 450 micrometer bands. These bands cover line emission from the important PDR tracers neutral carbon [CI] and carbon monoxide (CO). We have verified that the multiplexed bolometers are photon noise limited even with the low power present in moderate resolution spectrometry.

Benford, D. J.↗

The Rotational Excitation Temperature of the 6614 DIB Carrier

Analysis of high spectral resolution observations of the lambda6614 DIB line profile show systematic variations in the positions of the peaks in the substructure of the profile. These variations can only be understood in the framework of rotational contours of large molecules, where the variations are caused by changes in the rotational excitation temperature. We show that the rotational excitation temperature for the DIB carrier is of the order 10-40 K - much lower than the gas kinetic temperature - indicating that for this particular DIB carrier angular momentum buildup is not very efficient. The rotational constant indicates that the carrier of this DIB is smaller than previously assumed:7-22 C atoms, depending on the geometry.

Cami, J.↗

LISA technology department at JPL

The Laser Interferometer Space Antenna (LISA) project requires technology developments on many fronts. A physical understanding of the LISA subsystems is a precursor to tacjling the requirements needed to ensure a successful mission. This can only be achieved by developing the concepts in the lab prior to developing the payload. This poster presents updates on laboratory activities intended to prove the feasibility of measuring proof mass back reaction forces of less than 3fN/(square root)Hz at 1 mHz; the sensing of the proof mass position with in 2 nm/(square root)above the 3 mHz; and the resolution and accuracy of the phase-meter to better than 10 pm/(square root)Hz above the 3 mHz.

optical displacement sensor↗

A Celestial Reference Frame Based on Kalman Filtering

In this study, we investigate a novel approach to the determination of celestial reference frames (CRF). Instead of a constant model for radio sources positions, we adopt a time series representation, which allows temporal variations of radio source coordinates to be taken into account. In particular, the added flexibility is beneficial for radio sources with extended structure. We compute our time series-based CRF solutions by Kalman filtering and smoothing radio source positions, which are initially obtained from single-session VLBI analysis. The temporal resolution of the estimated CRF coordinates is identical to that of the input data, i.e. usually 1-4 days. The magnitude of the coordinate variations is controlled by the amount of process noise applied in the filter, which is in turn derived from analyzing the Allan standard deviation of the corresponding radio source coordinate time series. Measures have been developed to reduce the impact of observation errors and datum effects on the noise model.

Soja, B.↗

Upper E Traffic Management

This is a slide set as part of a meeting series with members of a working group aimed at the development of a concept that addresses needs and gaps in the management of high altitude airspace operations. This concept leverages elements developed through the UAS Traffic Management project with respect to a cooperative, service-based approach that provides services and capabilities in areas (e.g., Upper E airspace) that currently receive no or limited service from Air Traffic Control. This concept is meant to provide a safe, fair, and scalable approach to management of Upper E operations that reduces the burden on ATC while providing the flexibility and access desired by current and new users of the airspace. This set of slides includes an overview of discussions and industry news covering the time since the previous group meeting, a recap of the group's history and road ahead, a discussion of industry's initial position on, 'Industry principles for ETM rules of the road: Conflict identification and resolution,' and a simulation roadmap for planned work ahead.

Upper E↗

Characteristics of Un doped and Europium-dopedSrI2 Scintillator Detectors

High energy resolution gamma-ray detectors that can be formed into relatively large sizes while operating at room temperature offer many advantages for national security applications. We are working toward that goal through the development of SrI{sub 2}(Eu) scintillator detectors, which routinely provide <;3.0% energy resolution at 662 keV with volumes >;10 cm{sup 3}. In this study, we have tested pure, undoped SrI{sub 2} to gain a better understanding of the scintillation properties and spectroscopic performance achievable without activation. An undoped crystal grown from 99.999% pure SrI{sub 2} pellets was tested for its spectroscopic performance, its light yield, and uniformity of scintillation light collection as a function of gamma-ray interaction position relative to the crystal growth direction. Undoped SrI{sub 2} was found to provide energy resolution of 5.3% at 662 keV, and the light collection nonuniformity varied by only 0.72% over the length of the crystal. Measurements of both a 3% Eu-doped and the undoped SrI{sub 2} crystal were carried out in the SLYNCI facility and indicate differences in their light yield non-proportionality. The surprisingly good scintillation properties of the pure SrI{sub 2} crystal suggests that with high-purity feedstock, further reduction of the Eu concentration can be made to grow larger crystals while not adversely impacting the spectroscopic performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Biochemical and Structural Characterization of WlbA from Bordetella pertussis and Chromobacterium violaceum: Enzymes Required for the Biosynthesis of 2,3-Diacetamido-2,3-dideoxy-d-mannuronic Acid

The unusual sugar 2,3-diacetamido-2,3-dideoxy-d-mannuronic acid, or ManNAc3NAcA, has been observed in the lipopolysaccharides of both pathogenic and nonpathogenic Gram-negative bacteria. It is added to the lipopolysaccharides of these organisms by glycosyltransferases that use as substrates UDP-ManNAc3NAcA. Five enzymes are ultimately required for the biosynthesis of UDP-ManNAc3NAcA starting from UDP-N-acetylglucosamine. The second enzyme in the pathway, encoded by the wlba gene and referred to as WlbA, catalyzes the NAD-dependent oxidation of the C-3' hydroxyl group of the UDP-linked sugar. Here we describe a combined structural and functional investigation of the WlbA enzymes from Bordetella pertussis and Chromobacterium violaceum. For this investigation, ternary structures were determined in the presence of NAD(H) and substrate to 2.13 and 1.5 {angstrom} resolution, respectively. Both of the enzymes display octameric quaternary structures with their active sites positioned far apart. The octamers can be envisioned as tetramers of dimers. Kinetic studies demonstrate that the reaction mechanisms for these enzymes are sequential and that they do not require {alpha}-ketoglutarate for activity. These results are in sharp contrast to those recently reported for the WlbA enzymes from Pseudomonas aeruginosa and Thermus thermophilus, which function via ping-pong mechanisms that involve {alpha}-ketoglutarate. Taken together, the results reported here demonstrate that there are two distinct families of WlbA enzymes, which differ with respect to amino acid sequences, quaternary structures, active site architectures, and kinetic mechanisms.

59 BASIC BIOLOGICAL SCIENCES↗

Electrolyte-induced surface transformation and transition-metal dissolution of fully delithiated LiNi 0.8 Co 0.15 Al 0.05 O 2

Here, enabling practical utilization of layered R $\bar{3}$ m positive electrodes near full delithiation requires an enhanced understanding of the complex electrode–electrolyte interactions that often induce failure. Using Li[Ni 0.8 Co 0.15 Al 0.05 ]O 2 (NCA) as a model layered compound, the chemical and structural stability in a strenuous thermal and electrochemical environment was explored. Operando microcalorimetry and electrochemical impedance spectroscopy identified a fingerprint for a structural decomposition and transition-metal dissolution reaction that occurs on the positive electrode at full delithiation. Surface-sensitive characterization techniques, including X-ray absorption spectroscopy and high-resolution transmission electron microscopy, measured a structural and morphological transformation of the surface and subsurface regions of NCA. Despite the bulk structural integrity being maintained, NCA surface degradation at a high state of charge induces excessive transition-metal dissolution and significant positive electrode impedance development, resulting in a rapid decrease in electrochemical performance. Additionally, the impact of electrolyte salt, positive electrode surface area, and surface Li 2 CO 3 content on the magnitude and character of the dissolution reaction was studied.

25 ENERGY STORAGE↗

High resolution structure of the large ribosomal subunit from a Mesophilic Eubacterium

We describe the high resolution structure of the large ribosomal subunit from Deinococcus radiodurans (D50S), a gram-positive mesophile suitable for binding of antibiotics and functionally relevant ligands. The over-all structure of D50S is similar to that from the archae bacterium Haloarcula marismortui (H50S); however, a detailed comparison revealed significant differences, for example, in the orientation of nucleotides in peptidyl transferase center and in the structures of many ribosomal proteins. Analysis of ribosomal features involved in dynamic aspects of protein biosynthesis that are partially or fully disordered in H50S revealed the conformations of intersubunit bridges in unbound subunits, suggesting how they may change upon subunit association and how movements of the L1-stalk may facilitate the exit of tRNA.

59 BASIC BIOLOGICAL SCIENCES↗

Ligand‐Mediated Quantum Yield Enhancement in 1‐D Silver Organothiolate Metal–Organic Chalcogenolates

X-ray free electron laser (XFEL) microcrystallography and synchrotron single-crystal crystallography are used to evaluate the role of organic substituent position on the optoelectronic properties of metal–organic chalcogenolates (MOChas). MOChas are crystalline 1D and 2D semiconducting hybrid materials that have varying optoelectronic properties depending on composition, topology, and structure. While MOChas have attracted much interest, small crystal sizes impede routine crystal structure determination. A series of constitutional isomers where the aryl thiol is functionalized by either methoxy or methyl ester are solved by small molecule serial femtosecond X-ray crystallography (smSFX) and single crystal rotational crystallography. While all the methoxy examples have a low quantum yield (0-1%), the methyl ester in the ortho position yields a high quantum yield of 22%. Here, the proximity of the oxygen atoms to the silver inorganic core correlates to a considerable enhancement of quantum yield. Four crystal structures are solved at a resolution range of 0.8–1.0 Å revealing a collapse of the 2D topology for functional groups in the 2- and 3- positions, resulting in needle-like crystals. Further analysis using density functional theory (DFT) and many-body perturbation theory (MBPT) enables the exploration of complex excitonic phenomena within easily prepared material systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quadrant anode image sensor

A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, about 10 microns, allows individual MCP channels to be distinguished.

Lampton, M.↗

A grating-based single-shot x-ray phase contrast and diffraction method for in vivo imaging

Purpose: The purpose of this study is to develop a single-shot version of the grating-based phase contrast x-ray imaging method and demonstrate its capability of in vivo animal imaging. Here, the authors describe the principle and experimental results. They show the source of artifacts in the phase contrast signal and optimal designs that minimize them. They also discuss its current limitations and ways to overcome them. Methods: A single lead grid was inserted midway between an x-ray tube and an x-ray camera in the planar radiography setting. The grid acted as a transmission grating and cast periodic dark fringes on the camera. The camera had sufficient spatial resolution to resolve the fringes. Refraction and diffraction in the imaged object manifested as position shifts and amplitude attenuation of the fringes, respectively. In order to quantify these changes precisely without imposing a fixed geometric relationship between the camera pixel array and the fringes, a spatial harmonic method in the Fourier domain was developed. The level of the differential phase (refraction) contrast as a function of hardware specifications and device geometry was derived and used to guide the optimal placement of the grid and object. Both ex vivo and in vivo images of rodent extremities were collected to demonstrate the capability of the method. The exposure time using a 50 W tube was 28 s. Results: Differential phase contrast images of glass beads acquired at various grid and object positions confirmed theoretical predictions of how phase contrast and extraneous artifacts vary with the device geometry. In anesthetized rats, a single exposure yielded artifact-free images of absorption, differential phase contrast, and diffraction. Differential phase contrast was strongest at bone-soft tissue interfaces, while diffraction was strongest in bone. Conclusions: The spatial harmonic method allowed us to obtain absorption, differential phase contrast, and diffraction images, all from a single raw image and is feasible in live animals. Because the sensitivity of the method scales with the density of the gratings, custom microfabricated gratings should be superior to off-the-shelf lead grids.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗