Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Flow Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Play Fairway Analysis: Structurally Controlled Geothermal Systems in the Eastern Great Basin Extensional Regime, Utah

A research team with membership from the University of Utah/Energy & Geoscience Institute, the University of Utah/Dept. of Geology & Geophysics, and the Utah Geological Survey, undertook a play fairway analysis (PFA) for geothermal resources in the Eastern Great Basin (EGB) extensional tectonic regime of western Utah. This is a high-priority region for geothermal exploration because active Basin and Range (B&R) extension with volcanism having a N-S strike is superimposed upon pre-existing E-W belts of plutonic rocks and large-scale structural lineaments. Cumulative heat flow along the N-S strike of the state totals approximately 5 GWt above background stable interior. Three electricity producing power plants currently exist with substantial potential for increase. Succinctly, our PFA approach aims to resolve potential sources of heat and permeability in the region, which are the two principal criteria for establishing a geothermal resource. An initial Phase 1 was carried out using only existing geoscientific data in the area. Criteria selected for focusing heat potential include direct heat flow measurements in boreholes, magnetotelluric (MT) low resistivity anomalies, fluid/gas geochemistry, and proximity to recent volcanic eruptions. Permeability is established through geological structures (fault density, critically stressed areas, seismicity, gravity), and MT low resistivity anomalies. In Phase II of this PFA project, additional geological, geophysical and geochemical data were acquired and analysis carried out primarily over promising composite common risk (CCR) areas initially identified in Phase I in order to focus prospectivity and prepare for drilling recommendations. These prospects are near the Twin Peaks rhyolite field, high heat flow areas north of the producing Cove Fort system, and geophysical structure beneath the Crater Knoll area off the northeast flank of the Mineral Mountains. Additional data included MT site fill-in, structural mapping and analysis using high-resolution imagery, gravity and on-ground mapping, Nodal 3C passive seismic collection, and passive 3He surveying. Heat source and permeability potential are again expressed in terms of their individual common risk segment (CRS) maps, with a color scheme using green for most favorable (low risk) and red for least favorable (high risk). Diverse data types are united through the technique of probability kriging, which establishes prospectivity thresholds for each data type and then computes probability of exceeding that threshold over the PFA area. Modified CRS and CCRS maps are compared to those of Phase I to highlight tighter prospectivity focus. In doing so, the prospectivity threshold for heat was increased significantly to narrow the targeting. In the final Phase III of this project where a recommended deep thermal gradient hole was sited, additional geophysical, geochemical and geological field collection and analysis was carried out to refine drill hole targeting. This includes prospect-scale MT, gravity, structure, passive seismic deployment (Cove Fort area), and detailed 3He isotope profiling. It was the recommendation of the DOE Technical Monitoring Team (TMT) that one or more holes be sited in the north-ern Cove Fort area where legacy TG gradient holes showed high cumulative heat flow. These were to be of moderate depth, 2000-3000 feet, to reach the geothermal fluid table expected to start in excess of 1000 feet depth. The drilling organization stipulated by the DOE/GTO was that of the USGS Research Drilling Program (RDP) centered in Las Vegas, NV. A detailed well plan, appended to this report, was developed principally by Dr. Ben Barker consulting to University of Utah, Dr. Steve Pye on the DOE TMT, Mr. Steven Crawford of the USGS-RDP, and the project PI Phil Wannamaker. However, temperature and possible H 2 S at the systems lead to cancellation of the drilling last-minute as this appeared outside the experience base of the USGS-RDP. We hope to have the opportunity to revisit the test drilling and expand the Play Fairway Analysis of this region at some point in the future.

15 GEOTHERMAL ENERGY↗

Catalytic process for control of NO.sub.x emissions using hydrogen

A selective catalytic reduction process with a palladium catalyst for reducing NOx in a gas, using hydrogen as a reducing agent. A zirconium sulfate (ZrO.sub.2)SO.sub.4 catalyst support material with about 0.01-2.0 wt. % Pd is applied to a catalytic bed positioned in a flow of exhaust gas at about 70-200.degree. C. The support material may be (ZrO.sub.2--SiO.sub.2)SO.sub.4. H.sub.2O and hydrogen may be injected into the exhaust gas upstream of the catalyst to a concentration of about 15-23 vol. % H.sub.2O and a molar ratio for H.sub.2/NO.sub.x in the range of 10-100. A hydrogen-containing fuel may be synthesized in an Integrated Gasification Combined Cycle power plant for combustion in a gas turbine to produce the exhaust gas flow. A portion of the fuel may be diverted for the hydrogen injection.

08 HYDROGEN↗

Slow-Light Mid-IR Silicon Photonic Chips for NO 2 and CH 4 Gas Detection

A compact, chip-scale mid-infrared gas sensor is demonstrated, leveraging a two-dimensional photonic crystal waveguide (PCW) fabricated on a silicon-on-insulator (SOI) platform. The PCW comprises a hexagonal lattice with lattice constant a = 860 nm and hole radius r = 0.22a, incorporating a central line defect of reduced-radius holes (r s = 0.7r) to induce slow-light propagation near the photonic band edge with a group index of approximately 73, thereby enhancing light-matter interaction. The sensor operates at fundamental absorption wavelengths of 3.42 μm for nitrogen dioxide (NO 2 ) and 3.40 μm for methane (CH 4 ), utilizing the strongest molecular vibrational transitions for maximum sensitivity. Experimental validation was conducted using dynamically diluted gas mixtures generated by mass flow controllers, with signal acquisition performed by a liquid nitrogen-cooled InSb detector. For NO 2 , the sensor exhibited excellent linear response over 5–25 ppm (part per million) with coefficient of determination R 2 = 0.9934, achieving a detection limit of 210 ppb (part per billion)─representing the first reported silicon photonic-based NO 2 detection. For CH 4 , exposure to 25 ppm resulted in a 6.4% decrease in transmitted intensity, demonstrating multigas sensing capability. The CMOS-compatible fabrication process and compact 3 mm device footprint establish this SOI-PCW platform as a scalable, low-power solution for integrated mid-infrared gas sensing, with significant potential for environmental monitoring and industrial safety applications.

Crystals↗

BOP-301 and BOP-302R: Test Definitions and Analyses

Following the conclusion of the International Atomic Energy Agency (IAEA) coordinated research project (CRP) on analysis of two EBR-II tests, Argonne has continued its EBR-II analysis with additional tests from the Shutdown Heat Removal Test (SHRT) series. The tests selected for this follow-up analysis are BOP-301 and BOP-302R, two unprotected loss of heat of sink tests in which the intermediate sodium pump tripped without scramming the control rods or tripping the primary pumps. The IAEA CRP focused on the SHRT-17 and SHRT-45R tests, the most severe protected and unprotected loss of flow tests performed during the SHRT series. With the primary pumps tripping, flow rates decreased to levels where flowmeter uncertainty was very high. Accurately capturing the progressions of the two tests despite this uncertainty was one of the key modeling and simulation challenges during the CRP. BOP-301 and BOP-302R were selected because the primary sodium pumps did not trip for those tests. Primary flow rate measurements are known with greater certainty. Power and temperature discrepancies can be explored without concern that flow predictions match test measurements but not the actual flow rates from the tests. These two tests were performed during the same test window as SHRT-45R and had the same core load configuration. Therefore, core models created for analysis of SHRT-45R were easily adapted for analysis of BOP-301 and BOP-302R. Another reason for analyzing BOP-301 and BOP-302R is to analyze tests in which the core inlet temperature changed significantly, which did not occur during the loss of flow tests. The transient progression of the unprotected SHRT-45R test was driven by a decreasing core flow rate while the core inlet temperature remained relatively constant. For the BOP tests, the transient progression was driven by an increasing core inlet temperature while the core flow rate was stable. This report defines the BOP-301 and BOP-302R tests and provides a selection of measured test data. Initial predictions from SAS4A/SASSYS-1 simulations of these tests are then presented. Following these simulations, additional analysis was performed with the Dakota uncertainty quantification and optimization toolkit to determine which parameters have the greater impact on the transient results and the optimal values of the most important parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AGR-1, AGR-2 and AGR-3/4 Release-to-Birth Ratio Data Analysis

A series of Advanced Gas Reactor (AGR) irradiation tests is being conducted in the Advanced Test Reactor at Idaho National Laboratory in support of development and qualification of tristructural isotropic (TRISO) low enriched fuel used in the High Temperature Gas-cooled Reactor (HTGR). Each AGR test consists of multiple independently controlled and monitored capsules containing fuel compacts placed in a graphite cylinder shrouded by a steel shell. These capsules are instrumented with thermocouples embedded in the graphite enabling temperature control. AGR configuration and irradiation conditions are based on prismatic HTGR technology distinguished primarily by the use of helium coolant, a low-power-density ceramic core capable of withstanding very high temperatures, and TRISO coated particle fuel. Thus, these tests provide valuable irradiation performance data to support fuel process development, qualify fuel for normal operating conditions, and support development and validation of fuel performance and fission product transport models and codes. The release-rate-to-birth-rate ratio (R/B) for each of fission product isotopes (i.e., krypton and xenon) is calculated from release rates in the sweep gas flow measured by the germanium detectors used in the AGR Fission Product Monitoring (FPM) System installed downstream from each irradiated capsule. Birth rates are calculated based on the fission power in the experiment and fission product generation models. Thus, this R/B is a measure of the ability of fuel kernel, particle coating layers, and compact matrix to retain fission gas atoms preventing their release into the sweep gas flow, especially in the event of particle coating failures that occurred during AGR-2 and AGR-3/4 irradiations. The major factors that govern gaseous radioactive decay, diffusion, and release processes are found to be material diffusion coefficient, temperature, and isotopic decay constant. For each of all AGR capsules, ABAQUS-based three-dimensional finite-element thermal models are created to predict daily averages of fuel compact temperatures for the entire irradiation period, which are used in establishing the R/B correlation with temperature and decay constant. This correlation can be used by reactor designers to estimate fission gas release from postulated failed fuel particles in HTGR cores, which is the key safety factor for fuel performance assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Single bi-temperature thermal storage tank for application in solar thermal plant

Thermocline storage tanks for solar power systems are disclosed. A thermocline region is provided between hot and cold storage regions of a fluid within the storage tank cavity. One example storage tank includes spaced apart baffles fixed relative to the tank and arranged within the thermocline region to substantially physically separate the cavity into hot and cold storage regions. In another example, a flexible baffle separated the hot and cold storage regions and deflects as the thermocline region shifts to accommodate changing hot and cold volumes. In yet another example, a controller is configured to move a baffle within the thermocline region in response to flow rates from hot and cold pumps, which are used to pump the fluid.

14 SOLAR ENERGY↗

AGR-2 and AGR-3/4 Release-to-Birth Ratio Data Analysis

A series of Advanced Gas Reactor (AGR) irradiation tests is being conducted in the Advanced Test Reactor at Idaho National Laboratory in support of development and qualification of tristructural isotropic (TRISO) low enriched fuel used in the High Temperature Gas-cooled Reactor (HTGR). Each AGR test consists of multiple independently controlled and monitored capsules containing fuel compacts placed in a graphite cylinder shrouded by a steel shell. These capsules are instrumented with thermocouples embedded in the graphite enabling temperature control. AGR configuration and irradiation conditions are based on prismatic HTGR technology distinguished primarily by the use of helium coolant, a low-power-density ceramic core capable of withstanding very high temperatures, and TRISO coated particle fuel. Thus, these tests provide valuable irradiation performance data to support fuel process development, qualify fuel for normal operating conditions, and support development and validation of fuel performance and fission product transport models and codes. The release-rate-to-birth-rate ratio (R/B) for each of fission product isotopes (i.e., krypton and xenon) is calculated from release rates in the sweep gas flow measured by the germanium detectors used in the AGR Fission Product Monitoring (FPM) System installed downstream from each irradiated capsule. Birth rates are calculated based on the fission power in the experiment and fission product generation models. Thus, this R/B is a measure of the ability of fuel kernel, particle coating layers, and compact matrix to retain fission gas atoms preventing their release into the sweep gas flow, especially in the event of particle coating failures that occurred during AGR-2 and AGR-3/4 irradiations. The major factors that govern gaseous radioactive decay, diffusion, and release processes are found to be material diffusion coefficient, temperature, and isotopic decay constant. For each of all AGR capsules, ABAQUS-based three-dimensional finite-element thermal models are created to predict daily averages of fuel compact temperatures for the entire irradiation period, which are used in establishing the R/B correlation with temperature and decay constant. This correlation can be used by reactor designers to estimate fission gas release from postulated failed fuel particles in HTGR cores, which is the key safety factor for fuel performance assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Study of Seamless Microgrid Transition Operation Using Grid-Forming Inverters

This paper investigates operational techniques to achieve seamless (smooth) microgrid (MG) transitions by dispatching a grid-forming (GFM) inverter. In traditional approaches, the GFM inverter must switch between grid-following (GFL) and GFM control modes during MG transition operation. Today's inverter technology allows GFM inverters to always operate in GFM control mode, so it is worth exploring how to use them to achieve smooth MG transition operation. This paper proposes three operational techniques: a traditional scheme of switching between GFL and GFM control; a new scheme of consistent GFM control and shifting the droop intercept up before islanding operation; and a new scheme of consistent GFM control and shifting the droop intercept up before synchronization operation. A full hardware setup is established to compare the three techniques and showcase their implementations in real-world applications. The results show that the third technique outperforms the others and exhibits the best transition performance because the GFM inverter maintains the same operating points during the transition operation. Therefore, we conclude that ensuring smooth MG transition operation requires that the GFM inverter(s) maintain the same operating points (v, f, P, Q, and phase angle) during the transition operation in addition to minimizes the point of common coupling power flow.

grid-forming↗

High-Speed and High-Quality Field Welding Repair Based on Advanced Non-Destructive Evaluation and Numerical Modeling

Creep strength-enhanced ferritic (CSEF) steels such as Grade 91 (9Cr-1Mo-V) and Grade 92 (Fe-9Cr-2W-0.5Mo) steels are widely used in the fossil-fuel-fired and nuclear power plants. The weld integrity of these steels is crucial for power plants' safe and reliable operations. Due to harsh service conditions, the steel weld can become susceptible to environmental degradation. Field welding repair is used to restore the degraded weld’s performance where a controlled temper-bead welding technique is commonly used to temper the freshly formed martensite during welding. However, knowledge of weld repairability is limited and experimental trial and error optimization to achieve desired microstructure and joint properties is expensive and time-consuming. Many existing computational models, e.g., finite element models, are limited to solving heat conduction equation and ignoring convective heat transfer due to molten metal flow. These models can result in over-prediction of peak temperatures of weld pool and heat-affected zone (HAZ), which in turn can affect the accuracy of tempering prediction. Moreover, these finite element models require an input of the deposit profiles in advance and thus limits the usability of these models. Here, a molten pool-based, multi-pass multi-layer model has been developed based on computational fluid dynamics (CFD) approach with the Volume of Fluid (VOF) method. The model calculates the bead formation, thereby eliminating the need for pre-determined bead profiles required by finite element models. For computational efficiency, a coordinate system attached to the moving heat source is utilized. A subroutine is developed to convert the temperature profiles in the reference frame stationary to the heat source to that stationary to the workpiece. The converted thermal cycles are then imported into a microstructure model to compute the tempering kinetics and resultant hardness using a Johnson-Mehl-Avrami-Kolmogorov (JMAK), and modified Grange-Baughman parameter. The modeling approach is first developed and validated on single- and multi-pass deposition of stainless steel filler metal onto a SA-533 high strength steel substrate. The models are then applied to a multi-pass V-groove repair weld of Grade 91 steel plate as well as directed energy deposition of Grade 92 steel. Non-destructive characterization of microstructures was performed on Grade 91 and 92 steel welds. Two welding processes, cold metal transfer (CMT) and flux-cored arc welding (FCAW), were investigated for the Grade 91 steel weld samples. For the Grade 92 weld samples, three different heat inputs (low, medium, and high) of gas tungsten arc welding (GTAW) were utilized to replicate traditional field welding processes. The non-destructive evaluation (NDE) method used for this research was immersion ultrasonic testing (UT) using a micro-resolution ultrasonic imaging methodology specifically designed to operate in the through-transmission configuration operating at 20 MHz of frequency. The system used a focused ultrasonic beam spot size diameter between 250-300 μm, and a 6 μm laser vibrometer spot size for detection, to produce highly defined images with longitudinal and mode-converted shear waves. From the micro-resolution ultrasonic C-scan images, three microstructural regions, i.e., weld metal (WM), HAZ, and base metal (BM), were clearly identifiable. Various levels of ultrasonic amplitudes distributed over the three regions were correlated with electron beam backscattered diffraction (EBSD) images using grain size, grain boundaries, and dislocation densities. The results showed that areas with relatively higher ultrasonic amplitude levels were associated with smaller grains and higher dislocation densities, while areas with lower amplitude levels were associated with larger grains and lower dislocation densities. In addition, ultrasonic velocity data obtained across the three different weld microstructural regions of Grade 91 test samples were correlated with optical metallographic images and hardness measurements. The results showed distinctive decreases in ultrasonic velocity and hardness over the HAZ region, where weld failures often occur during service.

36 MATERIALS SCIENCE↗

Enabling Staged Pressurized Oxy-Combustion: Improving Flexibility and Performance at Reduced Cost

Introduction: The staged pressurized oxy-combustion (SPOC) process, developed by Washington University in St. Louis (WUSTL), is an oxy-combustion carbon capture technology that employs a steam power cycle to generate electricity. As with atmospheric-pressure oxy-combustion processes, carbon dioxide (CO 2 ) capture rates of 90% or higher can be achieved. The staged-combustion approach of the SPOC process, when operated at elevated gas pressure, allows for near elimination of flue gas recycle (FGR) and leads to significant improvements in efficiency and reduced costs. The primary goal of this project was to investigate the potential for SPOC for flexible operation beyond the capabilities of conventional coal-fired power plants, particularly those employing carbon capture and storage (CCS). Oxy-combustion differs from conventional coal combustion in that the combustion of coal is carried out using oxygen as opposed to air. The resultant flue gas is a mixture of primarily CO 2 and water, greatly simplifying CO 2 capture. As SPOC does the oxy-combustion process under pressure, it is higher efficiency and lower cost than atmospheric oxy-combustion. The project was led by the Electric Power Research Institute, Inc., with the assistance of WUSTL, Doosan Babcock (DBL – boiler plant original equipment manufacturer), and Air Liquide (AL – air separation experts). The specific objectives of the project were to: (1) Evaluate the SPOC concept and develop a risk-based approach to the heating surface layout ensuring that performance (gas and steam side), manufacturing, transportation, and plant erection considerations were fully accounted for in the system design. (2) Improve the technology to ensure its performance and cost potential are substantially better than today’s baseline pulverized coal power plant with post-combustion capture (PCC) or atmospheric oxy-combustion, and show progress toward performance commensurate with projected commercial operation, including 90% or more CO 2 capture. (3) Address critical technology gaps and improving overall system performance for the technology. (4) Perform combustion tests at scale under commensurate pressure to the commercial operating system validate combustor and advance the SPOC combustion modeling tools that will facilitate full-scale design. Combustion Testing: Testing was initially carried out at atmospheric pressure with methane to ensure that all systems were correctly operating. Following this, the testing then proceeded to moderate pressure operation at 4 bara, where different stoichiometric conditions were used across an extended heat input range, showing that a stable flame could be maintained. Testing then proceeded at 10 and 15 bara where it was shown that the ignition system needed to be replaced at these operating conditions. When testing recommenced, a similar stable flame shape was achieved, without any methane support, and the full 100 kWth coal oxy-combustion was demonstrated. Heat flux measurements showed 400 kW/m 2 (0.126 MMBtu/hr-ft 2 ) from the flame, within the 450 kW/m 2 (0.142 MMBtu/hr-ft 2 ) preferred limit defined by DBL for the full-scale design case. Carbon monoxide and carbon-in-ash measurements showed that complete combustion was possible with ultra-low excess oxygen at 1 vol % in the product flue gas. This allowed the full-scale models to be calculated based on this level of excess oxygen, improving the performance of the system as lower feed oxygen is produced in the air separation unit (ASU), saving auxiliary power. Full-Scale Design: The full-scale design is sized to deliver 550 MWe net electrical power output to allow direct comparison with the National Energy Technology Laboratory (NETL) baseline cases using the same Montana Powder River Basin (PRB) fuel. The cases used for direct comparison are: Case S12A (supercritical [SC] coal without CO 2 capture), Case S12B (SC coal with PCC at 90% CO 2 capture, and Case S12F (atmospheric oxy-combustion SC coal with 90% CO 2 capture). The SPOC stages were configured to be identical arrangements, allowing for a more straightforward design, construction, and control strategy. Each stage consists of two PVs, the first being the combustor PV module and the second being the convective PV module. The combustor module is the tallest vessel, with local coal feeding equipment and the burner FGR and oxygen plenums at the top and ash management at the bottom. The combustor module is effectively an open cross section with membrane tubes around the circumference – this unobstructed slender profile ensures that the relatively slower burnout mechanism needed for the low-speed turbulent mixing burner can proceed unimpeded and that molten ash will not attach to any surfaces at an angle to the predominant flue gas flow. The steam turbine used in the SPOC design is essentially the same unit utilized in the atmospheric oxy-combustion case except the degree of heat recovery possible allows the low-pressure (LP) feedwater heater train to be eliminated. This is a result of being able to capture the latent heat of evaporation of the moisture produced in the combustion (normally lost to the stack). The SPOC system outperforms the NETL atmospheric oxy-combustion baseline case by 3.3% points and the PCC case by 7.5% points. This performance increase is mainly a result of the improved heat recovery possible from the product flue gas and from the reduced auxiliary power consumption from the ASU and the CO 2 compression and purification unit over the atmospheric equivalent. The combined improvement in boiler efficiency and reduction in the steam turbine heat rate resulted in a net improvement in the overall plant efficiency by 0.61%, to 35.6% on a HHV basis. This relatively small improvement in plant efficiency between sub-bituminous and bituminous coals shows the value of useful moisture latent heat recovery offered by the SPOC system when using low rank fuels. Flexibility and Turndown: The SPOC system has inherent high turndown capabilities because of a demonstrated high range of combustion stability and the ability to bypass stages, thereby reducing steam generation rates proportionally without altering firing rates in operating stages. ASU units do not generally offer significant turndown opportunities as they are limited by the performance of the compression plant. The baseline SPOC design has a 2-train ASU configuration, needed to be able to meet the 10,500 tonnes per day duty, that can deliver efficient turndown points between 85–100% load with both trains operating, and at 45–50% load with a single train operating. Outside these operating points, the flexibility and efficiency are limited and may be uncompetitive at loads below 45% as the ASU systems are unable to turndown beyond 85% for the base case and 70% for the flexible case. The ASU cold box for the flexible case was designed to operate at loads between 40-100%, below this operating range the purity of the produced oxygen cannot be guaranteed, resulting in additional load for the CPU equipment. The additional power consumption of these cases yields an uneconomic operating condition with poor efficiency when operating at low loads such as 25% and 12%. To address this flexibility constraint, AL evaluated how the ASU configuration could be altered to deliver efficient oxygen supply over the load range. This involved integrating the compressor duties across both ASU trains into a shared duty arrangement with multiple compressors, strategically sized to deliver the duty required across all load ranges between 40–100% by enabling different combinations of the main air compressors and the booster air compressors. The oxygen purity cannot be guaranteed below 40% load for each train – the power consumption at 25% and 12% loads were estimated based on the multi-compressor configuration at maximum turndown as these load cases were not considered in the flexible ASU design. With a different cold box configuration, i.e. number of trains, the entire load range could be delivered within oxygen purity specifications. Although there is a small efficiency reduction at full load, there are significant improvements in overall plant performance during low-load operation. The exact ASU configuration needed will therefore be dependent on the expected operating profile of the unit. Economic Analysis: Cost estimates for the baseline and the flexible cases were developed using NETL baseline case data for common BOP items and an Association for the Advancement of Cost Engineering International Class 5 (conceptual/screening study) assessment of key components unique to the SPOC system. The capital, operating, and maintenance costs were assessed along with the first-year power cost, levelized cost of electricity, and CO 2 captured and avoided cost for the SPOC cases were compared against the relevant NETL baseline cases in January 2019 dollars. Both SPOC cases achieve a lower cost that the alternative NETL baseline cases (with the flexible SPOC case being slightly higher than the baseline SPOC case due to the compounded impact of higher capital costs and lower efficiency at full load). The SPOC cases deliver a lower cost of CO 2 avoided than the NETL baseline cases due to greater efficiency in generating low-carbon power. However, the cost of CO 2 captured is higher because the higher efficiency of the SPOC process generates less CO 2 , hence less needs to be captured, resulting in a high capital cost being shared over a reduced CO 2 quantity. The flexible ASU adds 1.6% overall to the plant cost in comparison to the baseline case, but the efficiency improvements at loads below 50% are significant. Subsequently, depending on the plant load-profile expectation, the flexible ASU would be beneficial if the plant spends a significant portion of its operating life below 50% load. This kind of operating profile is likely to be required for all fossil plants when more renewable electricity generators are installed on the local grid, particularly solar power that can be predicted ahead of time, allowing for appropriate pricing signals to be incorporated into the diurnal cycle. R&D Recommendations: SPOC, while a promising technology, is a relatively recent concept and, as such, operability issues of combustor design and steam-side integration for such systems at a scale relevant to commercial deployment have not been evaluated. WUSTL has conducted extensive small pilot-scale (100 kWth) research to understand and advance pressurized oxy-combustion processes, including investigation of combustion and flame characteristics, radiative heat flux, burner operability, turn down, char burnout, ash characteristics, water-wash column operation, etc. for pressurized oxy-combustion systems. Nonetheless, at this stage in the development of the SPOC process, what is needed is a large-scale pilot plant that can serve to study pressurized oxy-combustion systems and components at a scale commensurate with the maturity of the technology. A scale of 10 MWth, which includes steam-side integration and two stages would yield essential information with respect to heat transfer characteristics both in the radiative and convective sections of the pressure vessels, and the ability to operate the fuel staging process. In addition, while modeling results indicate that combustion and flame characteristics improve with scale, direct studies of the combustor at this scale will ensure that the models can be relied upon for scale up to commercial scale. Furthermore, a detailed analysis must be performed to understand the scaling aspects of key components and systems.

20 FOSSIL-FUELED POWER PLANTS↗

Mathematical modeling of a moving bed reactor for post-combustion CO 2 capture

A mathematical model for a moving bed reactor with embedded heat exchanger has been developed for application to solid sorbent-based capture of carbon dioxide from flue gas emitted by coal-fired power plants. The reactor model is one-dimensional, non-isothermal, and pressure-driven. The two-phase (gas and solids) model includes rigorous kinetics and heat and mass transfer between the two phases. Flow characteristics of the gas and solids in the moving bed are obtained by analogy with correlations for fixed and fluidized bed systems. From the steady-state perspective, this work presents the impact of key design variables that can be used for optimization. From the dynamic perspective, the article shows transient profiles of key outputs that should be taken into account while designing an effective control system. Additionally, the article also presents performance of a model predictive controller for the moving bed regenerator under process constraints.

42 ENGINEERING↗

A simple novel device for air sampling by electrokinetic capture

A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrode assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.

47 OTHER INSTRUMENTATION↗

Method and apparatus for smart battery charging including a plurality of controllers each monitoring input variables

A method for managing the charging and discharging of batteries wherein at least one battery is connected to a battery charger, the battery charger is connected to a power supply. A plurality of controllers in communication with one and another are provided, each of the controllers monitoring a subset of input variables. A set of charging constraints may then generated for each controller as a function of the subset of input variables. A set of objectives for each controller may also be generated. A preferred charge rate for each controller is generated as a function of either the set of objectives, the charging constraints, or both, using an algorithm that accounts for each of the preferred charge rates for each of the controllers and/or that does not violate any of the charging constraints. A current flow between the battery and the battery charger is then provided at the actual charge rate.

25 ENERGY STORAGE↗

A Hierarchical OPF Algorithm with Improved Gradient Evaluation in Three-Phase Networks

Linear approximation commonly used in solving alternating-current optimal power flow (AC-OPF) simplifies the system models but incurs accumulated voltage errors in large power networks. Such errors will make the primal-dual type gradient algorithms converge to solutions with voltage violation. In this paper, we improve a recent hierarchical OPF algorithm that rested on primal-dual gradients evaluated with a linearized distribution power flow model. Specifically, we propose a more accurate gradient evaluation method based on an unbalanced three-phase nonlinear distribution power flow model to mitigate the errors arising from linearization. The resultant gradients feature a blocked structure that enables our development of an improved hierarchical primal-dual algorithm to solve the OPF problem. Numerical results on the IEEE 123-bus test feeder and a 4,518-node test feeder show that the proposed method can enhance voltage safety at comparable computational efficiency with the linearized algorithm.

approximation algorithms↗

River Dynamics Control Transit Time Distributions and Biogeochemical Reactions in a Dam-Regulated River Corridor

Residence Time Distributions (RTDs) exert an important control on biogeochemical translation in the hydrological systems. Previous tracer studies have revealed that RTDs often followed time-invariant exponential, lognormal, or heavy-tailed RTDs that have power-law behavior for long tails in headwater or low-order streams. However, there is a recognition that RTDs can be more complicated and time-variable in response to dynamic hydrological forcing. Here, we use particle tracking to estimate RTDs along the Hanford Reach of the Columbia River and to quantify the influences of river stage fluctuations. Particle tracking is conducted using the velocity field from high-resolution 3D groundwater flow simulations. The effects of hydrological forcing on the residence time distribution were evaluated by varying river flow boundary conditions and releasing particles in different time windows. Our results revealed that dynamic stage fluctuations created rapidly changing losing-gaining conditions in the river and led to highly transient RTDs, which contributes to multiple modes of RTDs. Dam-induced high-frequency (sub-daily) flow variation contributes to the short-time (sub-daily) component of the RTDs. Deviation of the reactant consumption under the single-mode assumption compared to the multimodal RTDs is relatively small (~5%) and appears when the Damköhler number was close to one.More specifically, high-frequency (daily) dam-induced stage variations have higher impacts on biogeochemical reactions with faster reaction rate, and can potentially increase the reactant consumption by 26.68%. Based on these findings, we suggest that current river basin models could be improved by including bank storage and more complex RTDs influenced by both short and long term river stage fluctuations.

54 ENVIRONMENTAL SCIENCES↗

Solar reduction of carbon dioxide on copper-tin electrocatalysts with energy conversion efficiency near 20%

Abstract Copper catalysts modified with tin have been demonstrated to be selective for the electroreduction of carbon dioxide to carbon monoxide. However, such catalysts require the precise control of tin loading amount. Here, we develop a copper/tin-oxide catalyst with dominant tin oxide surface being formed via a spontaneous exchange reaction between sputtered tin and copper oxide. Even though the surface of this catalyst is tin-rich, it achieves an excellent performance towards carbon monoxide production in a flow cell. This contrasts with copper/tin-oxide prepared via atomic layer deposition since it yields selectivity towards carbon monoxide only on a copper-rich surface. Mechanism studies reveal that the tin sites on the tin-rich copper/tin-oxide surface achieve a suitable binding with adsorbed carbon monoxide under the presence of copper. Powered by a triple-junction solar cell, the copper/tin-oxide based electrolyzer sets a new benchmark solar-to-chemical energy conversion efficiency of 19.9 percent with a Faradaic efficiency of 98.9 percent towards carbon monoxide under simulated standard air mass 1.5 global illumination.

14 SOLAR ENERGY↗

Application of the NREL Test-to-Failure Protocol for PV Modules

Initial results of application of the NREL Test-to-Failure Protocol are presented and discussed. Six commercially available multicrystalline Si-cell flat-plate modules were subjected to the protocol with controls. The samples were divided among three test sequences, (1) 1000 hours of 85C/85% relative humidity with positive or negative 600 V bias to the active layers with respect to the grounded frame, (2) -40/85C thermal cycling with electrical load at the rated module power, and (3) an alternating sequence between tests (1) and (2). Application of the protocol manifested in the acceleration of degradation mechanisms seen in the field including backsheet delamination, corrosion, bubble formation within the laminate, discoloration of the antireflective coating, and localized heating with degradation of the backsheet as a result of moisture ingress, corrosion, and concentrated current flow. Significant differences in performance after one round of the protocol are seen in damp heat depending on the polarity of the bias applied to the active layer (the short-circuited power leads of the module). The protocol is found to successfully accelerate module degradation mechanisms that have been observed in the field and will help to differentiate the performance and reliability of various module technologies.

14 SOLAR ENERGY↗

Linking structural and transport properties in three-dimensional fracture networks

Here, we investigate large scale particle motion and solute breakthrough in sparse three-dimensional discrete fracture networks (DFN) characterized by power-law distributed fracture lengths. The three networks we consider have the same fracture intensity values but exhibit different percolation densities, geometric properties and topological structures. We considered two different average transport models to predict solute breakthrough, a streamtube model and a Bernoulli CTRW model, both of which provide insights into the flow fields within the networks. The streamtube model provides acceptable predictions at short distances in two of the networks, but fails in all cases to predict breakthrough times at the outlet plane, which indicates that particle motion in such fracture networks cannot be characterized by a constant velocity between the inlet and control plane at which the breakthrough curve is detected. Rather the structure of the network requires that frequent velocity transitions be made as particles move through the system. Despite the relatively broad distribution of fracture radii and relatively small number of independent velocity transitions, the CTRW approach conditioned on the initial velocity distribution provides reasonable predictions for the breakthrough curves at different distances from the inlet. The application of these averaged transport models provides a richer understanding of the link from the fracture network structure to ow and transport properties.

58 GEOSCIENCES↗