Search NASA⌕ Search

SEARCH · Search NASA

Results for “READOUT SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Performance of moire deflectometry with deferred electronic heterodyne readout

The effects of diffraction and nonlinear photographic emulsion characteristics on the performance of deferred electronic heterodyne moire deflectometry are theoretically and experimentally investigated. The intensity transmission distribution of the transparency, the moire image, the heterodyne readout, and the spatial and angular resolution are analytically discussed. The deferred electronic heterodyne technique is evaluated by measuring small fringe shifts caused by a weak phase object. It is found that this technique can be applied for accurate and sensitive readout of moire fringes of unsteady phase objects. The theoretical study shows that the accuracy and sensitivity of the system are weakly affected by diffraction and nonlinear photographic emulsion characteristics. Nonlinear recording does not affect the spatial resolution of the system.

Stricker, Josef↗

Euclid Near Infrared Spectro Photometer instrument concept and first test results obtained for different breadboards models at the end of phase C

The Euclid mission objective is to understand why the expansion of the Universe is accelerating through by mapping the geometry of the dark Universe by investigating the distance-redshift relationship and tracing the evolution of cosmic structures. The Euclid project is part of ESA's Cosmic Vision program with its launch planned for 2020 (ref [1]). The NISP (Near Infrared Spectrometer and Photometer) is one of the two Euclid instruments and is operating in the near-IR spectral region (900- 2000nm) as a photometer and spectrometer. The instrument is composed of: - a cold (135K) optomechanical subsystem consisting of a Silicon carbide structure, an optical assembly (corrector and camera lens), a filter wheel mechanism, a grism wheel mechanism, a calibration unit and a thermal control system - a detection subsystem based on a mosaic of 16 HAWAII2RG cooled to 95K with their front-end readout electronic cooled to 140K, integrated on a mechanical focal plane structure made with molybdenum and aluminum. The detection subsystem is mounted on the optomechanical subsystem structure - a warm electronic subsystem (280K) composed of a data processing / detector control unit and of an instrument control unit that interfaces with the spacecraft via a 1553 bus for command and control and via Spacewire links for science data This presentation describes the architecture of the instrument at the end of the phase C (Detailed Design Review), the expected performance, the technological key challenges and preliminary test results obtained for different NISP subsystem breadboards and for the NISP Structural and Thermal model (STM).

Maciaszek, Thierry↗

GADGET: a Gaseous Detector with Germanium Tagging

The Gaseous Detector with Germanium Tagging (GADGET) is a new detection system devoted to the measurement of weak, low-energy β-delayed proton decays relevant for nuclear astrophysics studies. It is comprised of a new gaseous Proton Detector equipped with a Micromegas readout for charged particle detection, surrounded by the existing Segmented Germanium Array (SeGA) for the high-resolution detection of the prompt γ-rays. Here in this work we describe in detail for the first time the design, construction, and operation of the GADGET system, including performance of the Proton Detector. We present the results of a recent commissioning experiment performed with 25 Si beam at the National Superconducting Cyclotron Laboratory (NSCL). GADGET provided low-background, low-energy β-delayed proton detection with efficiency above 95%, and relatively good efficiency for proton-gamma coincidences (2.7% at 1.37 MeV).

β-delayed proton emission↗

Engineering, Control, and Longitudinal Readout of Floquet Qubits

We discuss how properties of time-periodic Hamiltonians can be exploited to increase the dephasing time of qubits and to design protected one- and two-qubit gates. Recently, Huang et al. [Phys. Rev. Applied 15, 034065 (2021)] have shown that Floquet states offer a manifold of working points with dynamical protection larger than the few, usual, static sweet spots. Here, we show how Floquet theory, often used on systems with a single drive tone, can be used to describe approaches to robustly control Floquet qubits in the presence of multiple commensurate drive tones. Using this formulation, we introduce a longitudinal readout protocol to measure the Floquet qubit without the need of first adiabatically mapping the Floquet states back to the static qubit states, resulting in a significant speedup in the measurement time of the Floquet qubit. The analytical approach developed here can be applied to any Hamiltonian involving a small number of distinct drive tones, typical in the study of standard parametric gates for qubits outside of the rotating-wave approximation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Embedded Optical Sensing Systems For Distribution Transformer Monitoring

Traditional utility monitoring systems do not provide real-time visibility into the condition of transformers or accurate performance measurements. This has resulted in the use of lagging indicators, such as oil sample analysis, typically requiring expensive field visits, grid outages, and laboratory sample testing. This presentation reviews the use of optical sensing systems for managing transformers and improving grid resiliency and safety. The sensing systems allow direct internal monitoring of critical transformer components. Versatility covering different monitoring parameters of interest in embedded configurations for new transformers and a retrofittable configuration for older transformers is achieved by applying hair-thin multiplexed fiber-optic and other low-profile optical sensors in combination with a high-resolution optical readout and advanced analytics. Under an initiative funded by the DOE Office of Electricity, PARC, GE and Con Edison built, tested, and qualified commercial network transformers with embedded optical sensing systems. The parameters monitored were validated across a range of scenarios with lab instruments typically used for qualification testing. An ongoing field trial to demonstrate the robustness of the technology for remote monitoring through the industrial internet under demanding grid deployment conditions in New York City is showing promise toward scale-up of the technology. This presentation will provide an overview of the typical pain points in managing transformers and parameters for monitoring. It will also cover the requirements for highly constrained installations that need to have a larger capacity and flexible rating but that must fit into a tight space. The unique capabilities of optical sensing systems and a low-cost approach to interpreting the signals from sensors in transformers for predictive maintenance will be covered. The presentation will discuss the compatibility of the sensors in the transformer environment. It will discuss the validation testing per IEEE standards that enabled the solution to be implemented in field-deployable commercial transformers. The initial results from the field deployment and the potential for the technology to provide systematic alerts for unsafe/unexpected events will be discussed. The technology could enable utility professionals to gain information they can use to better plan for maintenance/management, and improve grid performance. This would in turn accommodate DERs and other evolving grid market dynamics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Individual control and readout of qubits in a sub-diffraction volume

Abstract Medium-scale ensembles of coupled qubits offer a platform for near-term quantum technologies as well as studies of many-body physics. A central challenge for coherent control of such systems is the ability to measure individual quantum states without disturbing nearby qubits. Here, we demonstrate the measurement of individual qubit states in a sub-diffraction cluster by selectively exciting spectrally distinguishable nitrogen vacancy centers. We perform super-resolution localization of single centers with nanometer spatial resolution, as well as individual control and readout of spin populations. These measurements indicate a readout-induced crosstalk on non-addressed qubits below 4 × 10 −2 . This approach opens the door to high-speed control and measurement of qubit registers in mesoscopic spin clusters, with applications ranging from entanglement-enhanced sensors to error-corrected qubit registers to multiplexed quantum repeater nodes.

Bersin, Eric (ORCID:0000000306435534)↗

An FPGA-based readout chip emulator for the CMS ETL detector upgrade

Here, we present an FPGA-based readout chip emulator board for the CMS Endcap Timing Layer (ETL) detector upgrade. The emulator board uses an Intel Cyclone 10 GX FPGA to emulate the digital functions of four Endcap Layer Readout Chips (ETROCs). Based on the actual ETROC design, the firmware is implemented and verified. The emulator board is being used for the ETROC digital design verification and system development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PhotonIDs: ML-Powered Photon Identification System for Dark Count Elimination

Reliable single photon detection is the foundation for practical quantum communication and networking. However, today's superconducting nanowire single photon detector(SNSPD) inherently fails to distinguish between genuine photon events and dark counts, leading to degraded fidelity in long-distance quantum communication. In this work, we introduce PhotonIDs, a machine learning-powered photon identification system that is the first end-to-end solution for real-time discrimination between photons and dark count based on full SNSPD readout signal waveform analysis. PhotonIDs ~demonstrates: 1) an FPGA-based high-speed data acquisition platform that selectively captures the full waveform of signal only while filtering out the background data in real time; 2) an efficient signal preprocessing pipeline, and a novel pseudo-position metric that is derived from the physical temporal-spatial features of each detected event; 3) a hybrid machine learning model with near 98% accuracy achieved on photon/dark count classification. Additionally, proposed PhotonIDs ~ is evaluated on the dark count elimination performance with two real-world case studies: (1) 20 km quantum link, and (2) Erbium ion-based photon emission system. Our result demonstrates that PhotonIDs ~could improve more than 31.2 times of signal-noise-ratio~(SNR) on dark count elimination. PhotonIDs ~ marks a step forward in noise-resilient quantum communication infrastructure.

Linne, Karl C. [Chicago U.] (ORCID:000900091870358↗

Multisensor Arrays for Greater Reliability and Accuracy

Arrays of multiple, nominally identical sensors with sensor-output-processing electronic hardware and software are being developed in order to obtain accuracy, reliability, and lifetime greater than those of single sensors. The conceptual basis of this development lies in the statistical behavior of multiple sensors and a multisensor-array (MSA) algorithm that exploits that behavior. In addition, advances in microelectromechanical systems (MEMS) and integrated circuits are exploited. A typical sensor unit according to this concept includes multiple MEMS sensors and sensor-readout circuitry fabricated together on a single chip and packaged compactly with a microprocessor that performs several functions, including execution of the MSA algorithm. In the MSA algorithm, the readings from all the sensors in an array at a given instant of time are compared and the reliability of each sensor is quantified. This comparison of readings and quantification of reliabilities involves the calculation of the ratio between every sensor reading and every other sensor reading, plus calculation of the sum of all such ratios. Then one output reading for the given instant of time is computed as a weighted average of the readings of all the sensors. In this computation, the weight for each sensor is the aforementioned value used to quantify its reliability. In an optional variant of the MSA algorithm that can be implemented easily, a running sum of the reliability value for each sensor at previous time steps as well as at the present time step is used as the weight of the sensor in calculating the weighted average at the present time step. In this variant, the weight of a sensor that continually fails gradually decreases, so that eventually, its influence over the output reading becomes minimal: In effect, the sensor system "learns" which sensors to trust and which not to trust. The MSA algorithm incorporates a criterion for deciding whether there remain enough sensor readings that approximate each other sufficiently closely to constitute a majority for the purpose of quantifying reliability. This criterion is, simply, that if there do not exist at least three sensors having weights greater than a prescribed minimum acceptable value, then the array as a whole is deemed to have failed.

Immer, Christopher↗

Benchmarking Quantum Simulators Using Ergodic Quantum Dynamics

Here we propose and analyze a sample-efficient protocol to estimate the fidelity between an experimentally prepared state and an ideal target state, applicable to a wide class of analog quantum simulators without advanced spatiotemporal control. Our protocol relies on universal fluctuations emerging from generic Hamiltonian dynamics, which we discover in the present work. It does not require fine-tuned control over state preparation, quantum evolution, or readout capability, while achieving near optimal sample complexity: a percent-level precision is obtained with ~103 measurements, independent of system size. Furthermore, the accuracy of our fidelity estimation improves exponentially with increasing system size. We numerically demonstrate our protocol in a variety of quantum simulator platforms, including quantum gas microscopes, trapped ions, and Rydberg atom arrays. We discuss applications of our method for tasks such as multiparameter estimation of quantum states and processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A High Resolution Monolithic Crystal, DOI, MR Compatible, PET Detector

The principle objective of this proposal is to develop a positron emission tomography (PET) detector with depth-of-interaction (DOI) positioning capability that will achieve state of the art spatial resolution and sensitivity performance for small animal PET imaging. When arranged in a ring or box detector geometry, the proposed detector module will support <1 mm 3 image resolution and >15% absolute detection efficiency. The detector will also be compatible with operation in a MR scanner to support simultaneous multi-modality imaging. The detector design will utilize a thick, monolithic crystal scintillator readout by a two-dimensional array of silicon photomultiplier (SiPM) devices using a novel sensor on the entrance surface (SES) design. Our hypothesis is that our single-ended readout SES design will provide an effective DOI positioning performance equivalent to more expensive dual-ended readout techniques and at a significantly lower cost. Our monolithic crystal design will also lead to a significantly lower cost system. It is our goal to design a detector with state of the art performance but at a price point that is affordable so the technology can be disseminated to many laboratories. A second hypothesis is that using SiPM arrays, the detector will be able to operate in a MR scanner without any degradation in performance to support simultaneous PET/MR imaging. Having a co-registered MR image will assist in radiotracer localization and may also be used for partial volume corrections to improve radiotracer uptake quantitation. The far reaching goal of this research is to develop technology for medical research that will lead to improvements in human health care.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of cosmic ray impact on transmon qubits with different materials through fast decay detection at Fermilab’s SQMS laboratory

Noise sources affecting superconducting qubits, such as cosmic rays and ambient gamma radiation, have garnered attention for their potential impact. These radiations deposit energy in the qubit's substrate, generating high-energy phonons that break Cooper pairs, leading to the formation of quasi-particles. When these quasi-particles tunnel across Josephson junctions, they induce qubit de-excitation, causing relaxation errors. In this study, we employ a fast feedback mechanism for performing qubit reset to detect decay events with high time resolution. This capability along with frequency multiplexed readout allows us to explore error correlations across time and space. Transmon qubits, manufactured within the Superconducting Quantum Materials and Systems (SQMS) center [1], are investigated at the above-ground lab. We study the impact of cosmic rays on qubits with different encapsulations, geometries, and locations on the same or different chips. We present preliminary findings and discuss the implications for the performance of contemporary quantum hardware.

Roy, Tanay↗

Precise Measurements of the Density and Critical Phenomena Near Phase Transitions in Liquid Helium

The first-year progress for the project of precise measurements of the density and critical phenomena of helium near phase transitions is summarized below: (1) completion of a cryogenic sample probe for the proposed measurements, and the rehabilitation of a designated laboratory at Caltech for this project; (2) construction and testing of a superconducting niobium cavity; (3) acquisition of one phase-locked-loop system for high-resolution frequency control and read- out; (4) setting up high-resolution thermometry (HRT) for temperature readout and control; (5) developing new approaches for calibrating the coefficient between the resonant frequency shift (delta f) and the helium density (rho), as well as for measuring the effect of gravity on T(sub lambda) to a much better precision; (6) programming of the interface control of all instruments for automatic data acquisition; and (7) improving data analyses and fitting procedures.

Yeh, Nai-Chang↗

Analyzing Contents of a Computer Cache

The Cache Contents Estimator (CCE) is a computer program that provides information on the contents of level-1 cache of a PowerPC computer. The CCE is configurable to enable simulation of any processor in the PowerPC family. The need for CCE arises because the contents of level-1 caches are not available to either hardware or software readout mechanisms, yet information on the contents is crucial in the development of fault-tolerant or highly available computing systems and for realistic modeling and prediction of computing- system performance. The CCE comprises two independent subprograms: (1) the Dynamic Application Address eXtractor (DAAX), which extracts the stream of address references from an application program undergoing execution and (2) the Cache Simulator (CacheSim), which models the level-1 cache of the processor to be analyzed, by mimicking what the cache controller would do, in response to the address stream from DAAX. CacheSim generates a running estimate of the contents of the data and the instruction subcaches of the level-1 cache, hit/miss ratios, the percentage of cache that contains valid or active data, and time-stamped histograms of the cache content.

Beahan, John↗

XAMPS Detectors Readout ASIC for LCLS

An ASIC for the readout of signals from X-ray Active Matrix Pixel Sensor (XAMPS) detectors to be used at the Linac Coherent Light Source (LCLS) is presented. The X-ray Pump Probe (XPP) instrument, for which the ASIC has been designed, requires a large input dynamic range on the order of 104 photons at 8 keV with a resolution of half a photon FWHM. Due to the size of the pixel and the length of the readout line, large input capacitance is expected, leading to stringent requirement on the noise optimization. Furthermore, the large number of pixels needed for a good position resolution and the fixed LCLS beam period impose limitations on the time available for the single pixel readout. Considering the periodic nature of the LCLS beam, the ASIC developed for this application is a time-variant system providing low-noise charge integration, filtering and correlated double sampling. In order to cope with the large input dynamic range a charge pump scheme implementing a zero-balance measurement method has been introduced. It provides an on chip 3-bit coarse digital conversion of the integrated charge. The residual charge is sampled using correlated double sampling into analog memory and measured with the required resolution. The first 64 channel prototype of the ASIC has been fabricated in TSMC CMOS 0.25 {micro}m technology. In this paper, the ASIC architecture and performances are presented.

43 PARTICLE ACCELERATORS↗

Integrating IR detector imaging systems

An integrating IR detector array for imaging is provided in a hybrid circuit with InSb mesa diodes in a linear array, a single J-FET preamplifier for readout, and a silicon integrated circuit multiplexer. Thin film conductors in a fan out pattern deposited on an Al2O3 substrate connect the diodes to the multiplexer, and thick film conductors also connect the reset switch and preamplifier to the multiplexer. Two phase clock pulses are applied with a logic return signal to the multiplexer through triax comprised of three thin film conductors deposited between layers. A lens focuses a scanned image onto the diode array for horizontal read out while a scanning mirror provides vertical scan.

Bailey, G. C.↗

Application of the Active Pixel Sensor Concept to Guidance and Navigation

Charge-coupled devices (CCDs) have been used extensively in the past in star trackers and fine guidance systems. A new technology, the active pixel sensor, is a possible successor to CCDs. This technology potentially features the same sensitivity and performance of the CCD with additional improvements. These improvements include random access capability, easy window-of-interest readout, non-destructive readout for signal-to-noise improvement, high radiation tolerance, simplified clocking voltages, and easy integration with other on-chip signal processing circuitry. The state-of-the-art of this emerging technology and its potential application to guidance and navigation systems is discussed.

Eisenman, Allan R.↗

Earth Observatory Satellite system definition study. Report 7: EOS system definition report

The Earth Observatory Satellite (EOS) study is summarized to show the modular design of a general purpose spacecraft, a mission peculiar segment which performs the EOS-A mission, an Operations Control Center, a Data Processing Facility, and a design for Low Cost Readout Stations. The study verified the practicality and feasibility of the modularized spacecraft with the capability of supporting many missions in the Earth Observation spectrum. The various subjects considered in the summary are: (1) orbit/launch vehicle tradeoff studies and recommendations, (2) instrument constraints and interfaces, (3) design/cost tradeoff and recommendations, (4) low cost management approach and recommendations, (5) baseline system description and specifications, and (6) space shuttle utilization and interfaces.

Source record↗