Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiator Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Radiative effects of polar stratospheric clouds

Radiative transfer calculations are performed for polar stratospheric clouds (PSCs) using newly acquired PSC properties and polar atmospheric data. PSC radiative effects depend strongly on upwelling thermal radiation and vary from infrared heating over warm polar surfaces, such as oceans, to cooling over cold surfaces, such as the Antarctic plateau. Heating and cooling rates of nitric acid PSCs are smaller than + or - 0.1 K/day. Rates for optically thicker ice PSCs vary from 1.0 to -0.2 K/day, those for orographically forced ice PSCs even from 3.0 to -0.5 K/day. Frequently observed optically thick cirrus decks near the tropopause provide a very cold radiative surface. These clouds not only act to prevent heating and enhance cooling in ice PSCs to -0.5 K/day and orographic ice PSCs to 2 K/day, but such cirrus cloud decks also cool the entire stratosphere by up to -0.5 K/day over warm surfaces, even in the absence of PSCs.

Kinne, S.↗

1500 MHZ Passive SRF Cavity for Bunch Lengthening in the NSLS-II Storage Ring

NSLS-II is a new ultra-bright 3 GeV 3rd generation synchrotron radiation light source. The performance goals require operation with a beam current of 500mA and a bunch current of at least 0.5mA. Ion clearing gaps are required to suppress ion effects on the beam. The natural bunch length of 3mm is planned to be lengthened by means of a third harmonic cavity in order to increase the Touschek limited lifetime. After an extensive investigation of different cavity geometries, a passive, superconducting two-cell cavity has been selected for prototyping. The cavity is HOM damped with ferrite absorbers on the beam pipes. The two-cell cavity simplifies the tuner design, compared to having two independent cells. Tradeoffs between the damping of the higher order modes, thermal isolation associated with the large beam tubes, and overall cavity length are described. A copper prototype has been constructed, and measurements of fundamental and higher order modes will be compared to calculated values.

43 PARTICLE ACCELERATORS↗

On the main photoelectric characteristics of three-junction InGaP/InGaAs/Ge solar cells in a broad temperature range (–197°C ≤ T ≤ +85°C)

This study is aimed at investigating the main photoelectric characteristics of three-cascade InGaP/InGaAs/Ge photoelectric converters in a broad temperature range (–197°C ≤ T ≤ +85°C). On account of analysis of photosensitivity spectra and optical current–voltage characteristics, such temperature dependences as the open-circuit voltage (V{sub oc}), filling factor of the current–voltage characteristic (FF), and the photoelectric conversion efficiency of solar radiation are determined. Investigations are performed at illumination intensities corresponding to operation under concentrated radiation. Decreased temperatures facilitate the selection of samples with the minimal “parasitic” potential barriers. The influence of excitationtransfer processes from a cascade into a cascade is estimated by means of secondary luminescent radiation. The highest photoelectric conversion efficiency of 52% is measured at a concentration multiplicity of 100 “suns” and a temperature of–160°C.

14 SOLAR ENERGY↗

Space solar cells - High efficiency and radiation damage

The proceedings of the Third Solar Cell High Efficiency and Radiation Damage Meeting are outlined. The topics covered included high efficiency silicon solar cells, silicon solar cell radiation damage, GaAs solar cell performance, and 30 percent conversion devices. The study of radiation damage from a fundamental defect-centered basis is discussed and evaluated as a focus of future work. 18% AM0 efficiency and 0.7 V open-circuit voltages are designated as achievable goals for silicon solar cells, and the potential for 30% AM0 efficiencies from monolithic tandem cell designs without sunlight concentration is noted. In addition to its potential for 20% AM0 efficiencies, the GaAs cell offers the possibility of a radiation-insensitive power supply when operated at temperatures near 200 C.

Brandhorst, H. W., Jr.↗

Virtual Guidance of Percutaneous Transthoracic Needle Biopsy with C-Arm Cone-Beam CT: Diagnostic Accuracy, Risk Factors and Effective Radiation Dose

Purpose: C-arm cone-beam computed tomography-guided transthoracic lung core needle biopsy (CBCT-CNB) is a safe and accurate procedure for the evaluation of patients with pulmonary nodules. The purpose of our study was to evaluate the diagnostic performance, complication rates and effective radiation dose of CBCT-CNB with virtual guidance. Materials and Methods: We retrospectively collected data regarding 375 CBCT-CNBs performed with virtual guidance (XperGuide—Philips Healthcare, Best, The Netherlands) from January 2010 to June 2015 on 355 patients (mean age, 68.1 years ± 11.8; age range, 31–88 years). Patients were divided into groups and compared based on the diagnostic failure and lesion size (15 mm cutoff). Diagnostic performance, complication rate and effective radiation dose were investigated. Variables influencing diagnostic performance and complications were assessed using Student’s T test and Pearson’s χ{sup 2} test. Results: The sensitivity, specificity, positive and negative predictive value and accuracy for patients subjected to CNBs were 96.8%, 100%, 100%, 100% and 97.2%, respectively. Considering risk factors for pneumothorax, no significant differences were found regarding patient and lesion characteristics. Perilesional hemorrhage occurred more frequently in older patients (p = 0.046) and in smaller lesions (p = 0.001). Hemoptysis was significantly more frequent in patients with perilesional hemorrhage (p = 0.01). Mean effective radiation dose in CBCT-CNB was 7.12 ± 8.78 mSv. Conclusions: CBCT-CNB combined with virtual guidance is a reliable and accurate technique that allows exact localization of pulmonary lesions, effective preprocedural planning and real-time fluoroscopy altogether.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of Cloud 3D Solvers in Ice Cloud Shortwave Radiation Closure Over the Equatorial Western Pacific Ocean

Abstract For retrieving cloud optical properties from satellite images or computing these properties from climate model output, computationally efficient treatments of cloud horizontal inhomogeneity include the Monte Carlo Independent Column Approximation (McICA) and the Tripleclouds method. Computationally efficient treatment of cloud horizontal radiation exchanges includes the SPeedy Algorithm for Radiative TrAnsfer through CloUd Sides (SPARTACUS). As a test to derive properties from satellite images, we collocate Moderate Resolution Imaging Spectroradiometer (MODIS) cloud retrievals with near‐nadir Cloud and the Earth's Radiant Energy System (CERES) footprints in July 2008 over an equatorial western Pacific Ocean region to compare the performance of the McICA, Tripleclouds, and SPARTACUS solvers to the conventional plane‐parallel homogeneous (PPH) treatment. PPH overestimates cloud albedo, and the three solvers effectively reduce overestimation with root mean square error of shortwave upwelling irradiance decreasing between 15.72 and 18.53 W m −2 , or about 22%–25%. Although cloud top variability does not get fed into the simulations, all three solvers also reduce the effect of cloud top variability on cloud albedo. Entrapment (energy reflected downward from clouds) and horizontal radiation transfer have opposite effects on the SPARTACUS cloud albedo simulation. The net effect depends on the cloud vertical extent, the unawareness of which limits the performance of the SPARTACUS solver.

54 ENVIRONMENTAL SCIENCES↗

Introduction to an MCGIDI Mini-App and Performance Comparisons with XSBench

In high-performance Monte Carlo (MC) radiation transport codes, cross section lookups often account for the majority of computational expens. In response to this observation, a number of nuclear data mini-apps have been developed to profile and optimize the lookup process. A review of these mini-apps can be found in Ref. In contrast to a fully fledged MC code, nuclear data mini-apps do not feature particle tracking; instead, the cross section lookup process is considered in isolation, a simplification that allows for easier implementation and evaluation of various lookup schemes and techniques. GIDI+, as described on its public repository1, is ...a collection of C++ libraries for accessing evaluated and processed nuclear data stored in the Generalized Nuclear Database Structure (GNDS). In addition to reading GNDS files, GIDI+ has functions to sum and collapse multi-group data as needed by deterministic transport codes, and to sample GNDS data as needed by Monte Carlo transport codes. Certain modes of Mercury, a LLNL-developed MC radiation transport code, utilize GIDI+ for cross section lookups. Specifically, Mercury uses the MCGIDI library contained within GIDI+ to perform lookups on GPUs. A mini-app exercising MCGIDI’s cross section lookup capabilities would prove useful for optimization, which in turn could improve the performance of client codes such as Mercury. Such a mini-app could also be used to assess the performance of MCGIDI compared to other nuclear data mini-apps. In this document, we introduce a nuclear data mini-app built with the MCGIDI library. The MCGIDI mini-app (MCGIDI-MA) was developed to closely resemble the methodology present in XSBench, a nuclear data mini-app developed at Argonne National Laboratory. The remainder of this section provides an overview on XSBench. Section 2 describes MCGIDI-MA and its usage. Section 3 contains performance results of MCGIDI-MA on LLNL’s Lassen and Quartz compute platforms, as well as comparisons to XSBench performance where appropriate. In Section 4, we present a summary of our findings.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An angular biasing method using arbitrary convex polyhedra for Monte Carlo radiation transport calculations

This paper presents a new method for performing angular biasing in Monte Carlo radiation transport codes using arbitrary convex polyhedra to define regions of interest toward which to project particles (DXTRAN regions). The method is derived and is implemented using axis-aligned right parallelepipeds (AARPPs) and arbitrary convex polyhedra. Attention is also paid to possible numerical complications and areas for future refinement. A series of test problems are executed with void, purely absorbing, purely scattering, and 50% absorbing/50% scattering materials. For all test problems tally results using AARPP and polyhedral DXTRAN regions agree with analog and/or spherical DXTRAN results within statistical uncertainties. In cases with significant scattering the figure of merit (FOM) using AARPP or polyhedral DXTRAN regions is lower than with spherical regions despite the ability to closely fit the tally region. This is because spherical DXTRAN processing is computationally less expensive than AARPP or polyhedral DXTRAN processing. Thus, it is recommended that the speed of spherical regions be considered versus the ability to closely fit the tally region with an AARPP or arbitrary polyhedral region. It is also recommended that short calculations be made prior to final calculations to compare the FOM for the various DXTRAN geometries because of the influence of the scattering behavior.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data analysis and software support for the Earth radiation budget experiment

Computer programming and data analysis efforts were performed in support of the Earth Radiation Budget Experiment (ERBE) at NASA/Langley. A brief description of the ERBE followed by sections describing software development and data analysis for both prelaunch and postlaunch instrument data are presented.

Edmonds, W.↗

Fabrication of Compact Superconducting Lowpass Filters for Ultrasensitive Detectors

It is extremely important for current and future far-infrared and sub-millimeter ultrasensitive detectors, which include transition edge sensors (TES) and microwave kinetic inductance detectors, to be adequately filtered from stray electromagnetic radiation in order to achieve their optimal performance. One means of filtering stray radiation is to block leakage associated with electrical connections in the detector environment. Here we discuss a fabrication methodology for realizing non-dissipative planar filters imbedded in the wall of the detector enclosure to limit wave propagation modes up to far-infrared frequencies. Our methodology consists of fabricating a boxed stripline transmission line, in which a superconducting (Nb, Mo, or Al) transmission line is encased in a silicon dioxide dielectric insulator coated with a metallic shell. We report on achieved attenuation and return loss and find that it replicates the simulated data to a high degree.

Brown, Ari↗

Metrics and Methods for Radiation Detection Algorithm Characterization for Nuclear/Radiological Source Search

This report presents a series of recommendations for data to train and evaluate radiation detection algorithms and performance metrics to evaluate these algorithms. These recommendations were formed through a community consensus approach through the Detection Radiation Algorithms Group (DRAG), a multi-institution collaboration spanning eight Department of Energy laboratories and John Hopkins Applied Physics Laboratory. This report includes recommendations on background data variability, and metrics to quantify variability, sources and shielding configurations to include in data collection campaigns and detector response variability. In addition, this report describes several anomaly detection and identification algorithms and recommends metrics to report their performance. Finally, this report ends with a discussion on machine learning algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton irradiation damage and annealing effects in ON Semiconductor J-series silicon photomultipliers

Silicon photomultipliers (SiPMs) have become popular light conversion devices in recent years due to their low bias voltage and sensitivity to wavelengths emitted from common scintillating materials. These properties make them particularly attractive for resource-constrained missions such as space-based detector applications. However, the space radiation environment is known to be particularly harsh on semiconductor devices, where high particle fluences can degrade performance over time. The radiation hardness of a particular SiPM, manufactured by ON Semiconductor (formally SensL), has yet to be studied with high energy protons, which are native to the space radiation environment. As such, to study these effects we have irradiated groups of two SiPMs to four different fluences of 800 MeV protons delivered by the accelerator at the Los Alamos Neutron Science Center. Fluences of 1.68 × 10 9 , 1.73 × 10 10 , 6.91 × 10 10 , and 1.73 × 10 11 protons cm –2 , and their corresponding estimated doses of 0.15, 1.55, 6.19, and 15.5 kRad, were chosen based on estimates of the potential exposure a SiPM might receive during an interplanetary space mission lasting 10 years. We report the effects these doses have on dark current and the self-annealing time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation effects induced by the energetic protons in 8x8x32 mm3 CdZnTe detectors

We report CdZnTe (CZT) detectors have been used in the past and are being actively considered for future gamma-ray space telescopes. One of the challenges of operating CZT detectors in low Earth orbit is radiation damage caused by energetic protons. Previous studies concluded that fluences of 10 8 -10 9 p/cm 2 are sufficient to cause shifting of peak positions and degradations of energy resolution. Degradation of detectors after proton irradiation has been extensively investigated to determine their radiation resistance limits and performance recovering procedures for their applications in space and nuclear nonproliferation. Here we present the study of radiation effects induced by 100 MeV protons in 3-cm long CdZnTe detectors that we recently proposed for the gamma-ray telescope GECCO. The goal this study is to evaluate the feasibility of using such long CZT detectors in future space missions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetry experiments at the MEDUSA Facility (Little Mountain).

A series of experiments on the MEDUSA linear accelerator radiation test facility were performed to evaluate the difference in dose measured using different methods. Significant differences in dosimeter-measured radiation dose were observed for the different dosimeter types for the same radiation environments, and the results are compared and discussed in this report.

43 PARTICLE ACCELERATORS↗

Performance of an electrically raised, synchronous satellite when subjected to radiation degradation effects

The use of solar electric propulsion to raise a high-power communication satellite from a low altitude, inclined circular orbit of the geosynchronous orbit is evaluated. Since the satellite ascends through the high intensity radiation belts, the power available from the solar array and therefore to the ion thrusters degrades. The performance of the solar electric stage in combination with the thrust augmented Thor/Delta launch vehicle is evaluated for two thrust steering programs. The transfer times and solar array requirements are presented for total geosynchronous payloads from 450 to 1100 kg.

Cake, J. E.↗

FIRST SCIENCE OBSERVATIONS WITH SOFIA/FORCAST: THE FORCAST MID-INFRARED CAMERA

The Stratospheric Observatory For Infrared Astronomy (SOFIA) completed its first light flight in May of 2010 using the facility mid-infrared instrument FORCAST. Since then, FORCAST has successfully completed 13 science flights on SOFIA. In this Letter, we describe the design, operation, and performance of FORCAST as it relates to the initial three Short Science flights. FORCAST was able to achieve near-diffraction-limited images for {lambda} > 30 {mu}m allowing unique science results from the start with SOFIA. We also describe ongoing and future modifications that will improve overall capabilities and performance of FORCAST.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of a Drifting Acoustic Instrumentation SYstem (DAISY) for characterizing radiated noise from marine energy converters

Marine energy converters can generate electricity from energetic ocean waves and water currents. Because sound is extensively used by marine animals, the radiated noise from these systems is of regulatory interest. However, the energetic nature of these locations poses challenges for performing accurate passive acoustic measurements, particularly with stationary platforms. The Drifting Acoustic Instrumentation SYstem (DAISY) is a modular hydrophone recording system purpose-built for marine energy environments. Using a flow shield in currents and mass–spring–damper suspension system in waves, we demonstrate that DAISYs can effectively minimize the masking effect of flow noise at frequencies down to 10 Hz. In addition, we show that groups of DAISYs can utilize time-delay-of-arrival post-processing to attribute radiated noise to a specific source. Consequently, DAISYs can rapidly measure radiated noise at all frequencies of interest for prototype marine energy converters. Furthermore, the resulting information from future operational deployments should support regulatory decision-making and allow technology developers to make design adjustments that minimize the potential for acoustic impacts as their systems are scaled up for utility-scale power generation.

16 TIDAL AND WAVE POWER↗